Loading...
HomeMy WebLinkAbout7- Tile Adhesive for Perimiter OnlyTRINITY ERD EVALUATION REPORT ICP Adhesives and Sealants, Inc. 12505 NW 44th Street Coral Springs, FL 33065 (888)774-1419 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT 13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report 02768.03.06-118 FL6332-R8 Date of Issuance: 08/08/2008 Revision 8: 10/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: ICP Adhesives Polyset® AH -160 LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/12/2017 This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinitvl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING COMPONENT EVALUATION; 1. \I TRINITY ERD SCOPE: Product Category: Roofing Sub -Category: Roof Tile Adhesives Compliance Statement: ICP Adhesives Polyset® AH -160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the 6th Edition (2017) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Sections 1504.2.1.1 3. REFERENCES: Entity ERD (TST 6049) ERD (TST 6049) ICC-ES(EVL2396) Miami -Dade (CER 1592) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) UL LLC (QUA 9625) 4. PRODUCT DESCRIPTION: Property Overturning resistance Examination Static Uplift —SSTD 11 Static Uplift—SSTD 11 2012 IBC Compliance HVHZ compliance Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift — SSTD 11 Static Uplift—SSTD 11 Static Uplift—SSTD 11 Static Uplift — SSTD 11 Static Uplift — SSTD 11 Static Uplift—SSTD 11 Static Uplift — SSTD 11 Quality Assurance Standard SSTD 11 Reference P39740.02.12 P39740.11.13 -R1 ESR -1709 17-0322.03 ECM -001-02-01 PFI -006-02-01 PFI -006-02-02 PFI -007-02-01 PFI -008-02-04 PFI -009-02-03 TG R I-001-02-03 TG RI -001-02-03 PFPI-010-02-01 PFPI-011-02-01 PFPI-012-02-01 PFPI-013-02-01 PFPI-014-02-01 ECM -003-02-01 ECM -004-02-01 ECM -005-02-01 ECM -006-02-01 ECM -007-02-01 ECM -008-02-01 Service Confirmation Year 1997 Date 02/20/2012 01/02/2015 12/01/2016 04/27/2017 09/21/2001 05/09/2005 05/09/2005 10/11/2005 02/21/2006 02/21/2006 10/30/2006 10/30/2006 12/07/2006 12/07/2006 12/07/2006 12/07/2006 12/07/2006 06/13/2008 06/13/2008 06/13/2008 06/13/2008 06/13/2008 06/13/2008 Exp. 06/05/2018 4.1 ICP Adhesives Polyset® AH -160 is a two -component expanding polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available in refillable tanks or disposable cylinders (ICP Adhesives ProPack° 30 & 100). 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8 Certificate of Authorization #9503 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset° AH -160; (888) 774-1419 Revision 8: 10/12/2017 Page 2 of 9 rT�INITi ERD 5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this product and FBC 1505.2. 5.4 ICP Adhesives Polyset' AH -160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives Polyset® AH -160. 5.6 Field tiles, meeting the limitations of FBC 1609.5.3, using ICP Adhesives Polyset® AH -160 are limited to projects having an Aerodynamic Uplift Moment (MJ, determined in accordance with FBC 1609.5.3 or Tables 2A and 2B of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 1: FIELD TILES IN ICP ADHESIVES POLYSETO AH -160 ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA 2 TO 1 MARGIN OF SAFETY ALREADYAPPLIED FOR INDEPENDENT (SINGLE OR CONTINUOUS PADDY) PLACEMENT 4 -To 1 MARGIN OFSAFETYALREADY APPLIED FOR INTERDEPENDENT (TWO PADDY) PLACEMENT Tile (FBC 1609.5.3) Allowable Adhesive Paddy Placement overturning Type Profile Moment (ft-lbf) Independent; Single Paddy, Medium (2x7 -inch, -30 gram) 60 Clay Flat Independent; Single Paddy, Large (2x10 -inch, -45 gram) 112 Concrete Interdependent; Two Paddy (4x4 -inch on underlayment, 2x4 -inch at tile overlap) 54 ' Independent; Single Paddy, Medium (20 -inch, -30 gram) 39 Clay or-_ Low/ Independent; Single Paddy, Large (2x10 -inch, -54 gram) 67 Concrete Medium) Interdependent; Two Paddy (4x4 -inch on underlayment, 2x4 -inch at tile overlap) 58 Clay High Independent; Single Paddy, Large (2x10 -inch, -45 gram) 134 Independent; Single Paddy, Medium (2x7 -inch, "30 gram) 65 Concrete Clay High Independent; Single Paddy, Large (2x10 -inch, -63 gram) 109 Interdependent; Two Paddy (4x4 -inch on underlayment, 2x4 -inch at tile overlap) 40 Clay Barrel 2x10 -inch x -35 gram for pans; 2 @ 1x10 -inch x -17 gram for cap 147 Concrete Barrel 2x10 -inch x -35 gram for pans; 2 @ 1x10 -inch x -17 gram for cap 107 Clay Cap atop 2x Independent: Continuous Paddy (-34 gram/ft) 135 stringer Concrete Cap atop 2x Independent: Continuous Paddy (^' 34 gram/ft) 116 stringer ClayCap atop 2x Interdependent: 105 stringer Head: One (1) #10 x 2'/2" screw; Overlap: 1 x 6 inch (^'10.5 gram) Concrete Cap atop 2x Interdependent: 76 stringer Head: One (1) #10 x 2'/2" screw; Overlap: 1 x 6 inch (^'10.5 gram) 5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April 2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP Adhesives Polyset® AH -160. 5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset® AH -160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent two -paddy method, an additional 2 -to -1 margin above that specified in SSTD it or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning moment'. Exterior Research and Design, LLC. Evaluation Report 02768.03.06-R8 Certificate o/Authorization #9503 6T" EDITION (2017) FBG NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset° AH -160; (888) 774-1419 Revision 8: 10/12/2017 Page 3 of 9 VT RINITY I ERD 5.7 Hip and ridge tiles using ICP Adhesives Polyset® AH -160 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 2: HIP & RIDGE TILES IN ICP ADHESIVES POLYSETO AH -160 ALLOWABLE UPLIFT RESISTANCE PERFORMANCE DATA 1 TO 1 MARGIN OFSAFETYALREADYAPPLIED FOR INDEPENDENT (CONTINUOUS PADDY) PLACEMENT 4 TO 1 MARGIN OF SAFETYALREADY APPLIED FOR INTERDEPENDENT PLACEMENT Allowable Tile Substrate Attachment Method Design Pressure Ipsf) Clay 2x PT ridge board Independent: Continuous Paddy ("34 gram/ft) 116 Concrete 2x PT ridge board Independent: Continuous Paddy (" 34 gram/ft) 107 Clay 2x PT ridge board Interdependent: Head: One (1) #10 x 2'/" screw; 90 Overlap: 1 x 6 inch ("10.5 gram) Interdependent: Head: One (1) #10 x 2'/2" screw; Concrete 2x PT ridge board Overlap: 1 x 6 inch ("10.5 gram) 56 Clay or Hip & Ridge Channel Metal (FL5374) Independent: Continuous Paddy ("34 gram/ft) 169 ncrete galvanized only Clay or Trim Lock TM (FL5374): aluminum, Independent: Continuous Paddy ("34 gram/ft) 173 Concrete galvanized, Galvalume® or stainless steel Clay or Trim Lock'"" Plus (FLS374): aluminum, Independent: Continuous Paddy (" 34 gram/ft) 178 Concrete galvanized, Galvalume° or stainless steel Clay Top Notch (FL8095) Independent: Continuous Paddy (" 32 gram/ft) 125 Concrete Top Notch (FL8095) Independent: Continuous Paddy ( 32 gram/ft) 146 6. INSTALLATION: 6.1 ICP Adhesives Polyset® AH -160 and the tile roof assembly shall be installed in accordance with FRSA/TRI April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the limitations outlined in Section 5. 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Tomball, TX 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3623; LeAnna.Gradecki@ul.com Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8 Certificate o/Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-118 ICP Adhesives Polyset® AH -160; (888) 774-1419 Revision 8: 10/12/2017 Page 4 of 9 TRINITY ERD 10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND SEALANTS, INC. PUBLISHED LITERATURE): 10.1 Independent, Medium Paddv: N.,il though plastic cement (when rec;iri re d} Underlayment o,i`� G '. G 1 1\ 7 in. 2 in. N'1� Battens optional ° Eave Course 0 a 101n. �i Paddy (Beneath Tile) 1 Flat/Low Profile Tile Nall through plastic cement (when required) s Underlayment \,/ Battensoptional Eave In. rr Paddy (Beneath Tlle) n. Eave Closure Fascia Medium Profile Tile Nall through plastic cement-, paddy (Beneath Tile) (when required) Undedayment 7In. 2 In. Battens optiona l 'j `tc r Eave Course-._ `` Fascla Weephole loin. Z in. Eave closure Drip edge High Profile Tile Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-118 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset® AH -160; (888) 774-1419 Revision 8: 10/12/2017 Page S of 9 10.2 Independent, Large Paddy: Nail through plastic cement (when required) Underlayment ° O I\ 10 ink Battens optional O FF!?'14 4'` Mti 2i Paddy 18eneeth Tile) Flat/Low Profile Tile ��l TRINITY ERD Nall through plastic cement (when required) Paddy (Beneath Tile) 4 Underlayment loin ri`.�� 2 in.wide1 Battens optional c �` �1. 1�. mac, 2in. Eave Closure Eave Course .'— Fascia Medium Profile Tile Nall through plasticce (when requl red) Paddy (BeneathTlle) Underlayment . 2 in.wide Battensty optional "rt" Eave Course - _ Fascia a Weephole 10 in. 2in. Eave closure ►' Drip edge High Profile Tile Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-118 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVH2 EVALUATION FL6332-118 ICP Adhesives Polyset° AH -160; (888) 774-1419 Revision 8: 10/12/2017 Page 6 of 9 10.3 Interdependent, Two Paddy: Nail through plastic cement When requiredl Battens optional ° n Singlepeddy on top of the x4in. on underlayment 2 x 4 in. 0 loin S v Flat/Low Profile Tile Exterior Research and Design, I.I.C. Certificate ofAuthorization #9503 (between tiles) Pedcly (undertile) Eave Closure �'l I RINITY ERD Nall through plastic cement Single paddy under tile (when required) Paddy (between tiles) Battens Paddy (under tile) optional a` Singl• paddy on top of the .; `r 4x411n. 2x41n. Single paddy on underlayment 10 in 4 tin. Eave Closure Eave Course Fascia Medium Profile Tile Nail through plastICce Single paddy under tile (when required) Paddy (between tiles) Battens ° aptioizal ct, y Paddy (under tile) r Singlepaddy �onunderlaymen[ r` y x4 in.� Singla 2x 4 in paddyan ~`^ topoftlle— Eave Course -- ''# Fascia Weephole loin tin. Eaveclosure Drip edge High Profile Tile Evaluation Report 02768.03.06-R8 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset® AH -160; (888) 774-1419 Revision 8: 10/12/2017 Page 7 of 9 10.4 10.5 Two Piece Barrel (Cap & Pan) Tile: 1) plica enough adhesive to achieve 65 to 70 sq, In. Steap plich applications In contact with the pan tile, when required) 21 Tum Coven opalde down. Place adheaWc 1121n.101 "-h in from gilt-lifeedge o} sever tile. Install cover tile. Ereaure 2e to 215 sq, 10, contpot oma cn each aide of .aver 1He. 1Ir1nderlayment 3' r,^.'f ,•'`fr Sheathing Eaveclssura t' (motor shown) weephole FastIs Beard Remove top portion of the save course cover tile. Abut to second course of pan tiles. Ensure save end of pan and cover tiles are flush at save line. Two Piece Barrel - High Profile Tile Hip and Ridge (independent placement): A bead of ICP PolysedbAH-166 may be applied above the field To attach hipindge tiles, a bead of 1CP Polyeel»AH-160 may file surface ou both sides of the Wpltldge board or golviolzed be applied down the center of the hq»ridge board or galvvdzed metal frame to provide weatherblockurg. frame. �l I RINITY ERD hr gnlled * he fill lrn�lr of rhe kle ra. AAq• ! awhea r;chrliar 7 Wil- mr the — and .f ids Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8 Certificate ofAuthorization 119503 6TH EDITION (2017) FEIC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset® AH -160; (888) 774-1419 Revision 8: 10/12/2017 Page 8 of 9 10.6 �I TRINITY IERD Hip and Ridge (interdependent placement): - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset® AH -160; (888) 774-1419 Revision 8: 10/12/2017 Page 9 of 9