HomeMy WebLinkAbout15-141.004.50 SP revised 2020.7.01 (slc permit 2002-0057)obi! i
^d � I
o 'CO)
)
n
0
SET 5/8" IR
O
0
W
coo
V_
n
N
EXISTING BUILDING
raj PROPOSED O tl• CO
O
PAD EL=19.38
BENCHMARK
SANITARY MANHOLE
RIM EL
I
RIM =16.76'
N. A. V. D. 1988
/C
/ SANITARY
RVICE
�
co / o S7g 36'06 BE
�^ FLOOD ZONE
11 o X
0
59.6
PROPOSED
6.63 4 6T COVERED
ENTRY
SET 5/8" IR/C
LB 4286 (TYP)
/
n
0
SET 5/8" IR
PROPOSED
LB 4286 (Tl
Lo
Z
,_WATER
LEGEND & ABBREVIATIONS
BB DENOTES BEARING BASE
CBS DENOTES CONCRETE BLOCK STRUCTURE
CD DENOTES CHORD DISTANCE
B DENOTES CHORD BEARING
DENOTES CENTER LINE
D.E. DENOTES DRAINAGE EASEMENT
F.F.E. DENOTES FINISH FLOOR ELEVATION
FND DENOTES FOUND
IR/C DENOTES IRON ROD AND CAP
L.B. DENOTES LICENSED BUSINESS
L DENOTES ARC LENGTH
N/D DENOTES NAIL AND DISK
O.S.T. DENOTES OPEN SPACE TRACT
P.S.M. DENOTES PROFESSIONAL SURVEYOR & MAPPER
P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR
R DENOTES RADIUS
R/W DENOTES RIGHT of WAY
U.E. DENOTES UTILITY EASEMENT
W.M.T. DENOTES WATER MANAGEMENT TRACT
A DENOTES INCLUDED ANGLE
DENOTES DRAINAGE FLOW
l DENOTES PROPOSED ELEVATION
GRAPHIC SCALE
20 0 10 20
51 � 1K FM
VACANT > i=h = zo &
F
1IJ�-
rn \—PROPOSED
o AC PAD
S87'40'51 "W X,�, 1,37A'
49
VACANT
AREA SUMMARY IN SQUARE FEET
SOD: 6,147 f
DRIVEWAY/WALKWAY:608 t
130.00' SET 5/8" IR/C
50
M
PROPOSED
o N
MODEL 4EBB/C
m �'I
FLOOD ZONE
F.F.E.=19.10
AE
GARAGE F.F.E.=18.50
EXISTING BUILDING
raj PROPOSED O tl• CO
O
PAD EL=19.38
rn \—PROPOSED
o AC PAD
S87'40'51 "W X,�, 1,37A'
49
VACANT
AREA SUMMARY IN SQUARE FEET
SOD: 6,147 f
DRIVEWAY/WALKWAY:608 t
130.00' SET 5/8" IR/C
LEGAL DESCRIPTION
LB 4286 (TYP)
10. No easements are shown hereon other than those depicted on the plat. No search of
Being all of Lot 50, according to the plat of CREEKSIDE PLAT NO. 4, as
m �'I
FLOOD ZONE
recorded in Plat Book 85, Page 5, Public Records of St. Lucie County, Florida.
AE
Containing 0.208 acres, more or less.
11. Elevations shown hereon are based on the North American Vertical Datum (N.A.V.D.) 1988.
raj PROPOSED O tl• CO
O
00 'V
CV LANAI ;) O
PROPERTY ADDRESS
3238 TRINITY CIRCLE, FORT PIERCE,
8. /^/'�ko
FLORIDA
0 00 // // C\4� 'a
not certified to and must be verified prior to design or construction.
36 03 v
Digitally by
0
GENERAL NOTES
8.00'R=25.00 '
1. The last date of field work was 06-14-19
A=30*43'22"2.
Additions or deletions to survey maps or reports by other than the signing party or
FND 4"x4" CM
L=13.41'
parties is prohibited without written consent of the signing party or parties.
PRM LB 4286
3. Reproductions of this map are not valid without the original signature and raised seal of
FND 4"x4" CM
a Florida Licensed Surveyor and Mapper.
PRM LB 4286
5p 24
4. Lands shown hereon were not abstracted by this office for rights—of—way, easements of
STATE Q
�ss
record, ownership, abandonment's, deed restrictions, or Murphy Act Deeds. This information
should be obtained through appropriate title verification.
R=190.00'
5. All above ground fixed improvements, if any, have been located and shown hereon.
�� A=230'38"
6. Underground foundations and improvements were not located as part of this survey.
SET 5/8" IR/C
LB 4286 (TYP) L=8.33
7. Flood Note: By graphic plotting only, this property is in Zone X and AE 16.9, according to
the Flood Insurance Rate Map, Community Panel No. 12111CO170 J, effective date February
"'•,,,,
16, 2012. The exact designation can only be determined by an elevation certificate. No
C';�,� 771.... C�_a_.�__ T
additional search of the public records has been preformed. There may be additional map
Amendments affecting this property.
8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel
and the use of existing field elevation data.
9. The bearings shown hereon are based on Plat information and are referenced to the
Northerly property line of Lot 50 which bears South 79'36'06" East and all bearings are
relative thereto.
THOMAS P. KIERNAN
Professional Surveyor & Mapper
Florida Certificate No. 6199
DATE
10. No easements are shown hereon other than those depicted on the plat. No search of
the public records has been performed to find additional easements that may exist.
11. Elevations shown hereon are based on the North American Vertical Datum (N.A.V.D.) 1988.
12. The building setbacks shown hereon, although based on the best available information, are
not certified to and must be verified prior to design or construction.
,.'•""'.
Digitally by
13. All improvements relating to this plat are either proposed or under construction.
,,••��PSP,K/FQ-.;
o. seN�•.,ti
signed
REVISION: ADDED EXISTING BUILDING PAD
ELEVATION GLM 7-01-2020
LS6799�6P ••, 9'fi �:
Thomas P Kiernan
REVISION: MOVED AC PAD GLM 2-19-2020
:.. .,
STATE Q
�ss
Date: 2020.07.01
F<°R°P•
"'•
Boundary Topographic
& File:15-141.004.050
CULPEPPER &
°a' O... '
���Survey ��,
14:24:38 —04'00'
Date: 11-18-2019
T
"'•,,,,
C';�,� 771.... C�_a_.�__ T
—� cn PP- tiro ■ Orin 1111rhCw11w1/! 1111IL1/►
THOMAS P. KIERNAN
Professional Surveyor & Mapper
Florida Certificate No. 6199
DATE