HomeMy WebLinkAboutEnergy CodeFORM 11COA-08
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs Residential Performance Method A
Project Name: Kamen residence
Builder Name:
Street 5606 Birch Dr
Permit Office: St Lucie County
City, State, Zip: Fort Pierce , Fl ,
Permit Number.
Owner. Gary Kaman
Design Location: FL, ST LUCIE_CO_INTL
Jurisdiction: 611000
A. New construction or ebsting
6fistmg (Projects
9. Wall Types (1400.0 sg1L)
Insulation Area
2. Single family or multiple family
Single-family
a. Frame -Wood. E)derlor
R=11.0 1400.00 R'
b. WA
R= iR
3. Number of units, if multiple family
1
c. WA
R= fF
4. Number of Bedrooms
1
d. WA
R= fP
5. Is this a worst case?
No
10. Ceiling Types (1106.0 sgfL)
Insulation Area
6. Conditioned floor area (it)
1106
a. Cathedral/Single Assembly (Unverded) R--n.0 1106.00 ft2
b. WA
R= fF
47. Windows(126.8 sgfL) Description
Area
c. WA
R= tP
a. U-Factor: Dbl, U=0.65
({428 iN
SHGC: SHGC=0.65
11. Ducts
b. U-Factor: Dbl, U=0.55
21.97 fl'
a. Sup: Interior Ret Interior AH: Interior Sup. R= 6, 40 fl'
SHGC: SHGC=0.60
12. Cooling systems
c. U-Factor. Sgl, U=0.65
20.50 f!=
a. Central Unit
Cap: 22.0 k5tift
SHGC: SHGC--0.55
SEER: 14
d. U-Factor. WA
iP
13. Heating systems
SHGC:
a. Electric Strip Heat
_
Cap:16.0 kBlWhr
e. U-Factor. N/A
fN
COP:1
SHGC:
14 water systems
8. Floor Types (1106.0 sgfL)
Insulation Area
a. Electric
a. El
Cap: 30 gallons
a. Raised Floor
R=19.0 1106.00 iF
EF: 0.95 '
b. WA
R= fIZ
b. Conservation features
c. N/A
R= ft'
None
-
15. Credits
CF. Pstat
Glass/Floor Area: 0.115
Total As -Built Modred Loads: 28.03
PASS
Total Baseline Loads: 32.98
I hereby certify that the plans and specifications covered by
Review of the plans and
LKE STq�F
this calculation are in complia
a FI 'da Ens
specifications covered by this
Of
a , 0�
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED B
Before construction is completed
9� _�" ' to
DATE:
this building will be inspected for
11e, y0
100,
compliance with Section 553:908
, �
I hereby certify that this buildin , as des i ned, is in compliance
Florida Statutes.
g�=
with the Florida Energy Co
CpDO
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
0%opy
6/11/2012a-1913M FILE tr;
PROJECT
Title:
Keman residence
Bedrooms: 1
Adress Type:
Street Address
Building Type:
FLAsBult
Conditioned Area: 1106
Lot#
Owner.
Gary Keman
Total Stories: 1
Block/SubDivision:
#of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street..
5606 Birch Dr
Permit Office:
St Lucie County
Cross Ventilation: No
County.
St Lucie
�Jurisdlctlon:
611000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
it Family Type:
Single-family
FI,
New/Existing:
Existing (Projected)
Comment
CLIMATE
/
IECC Design Temp Ind Design Temp Heating Design Daily Temp
V Design Location
TMY Site Zone 97.5 %
2.5 % Winter Summer Degree Days Moisture
Range
FL, ST LUCIE_CO_INTL FL ST LUCIE CO_INTL 2 39
90 75 70 722
58
Medium
FLOORS
#
Floor Type
R-Value
Area
Tile Wood
Carpet
1
Raised Floor
1106 ft2 19
0 0
1
ROOF
Roof Gable
Roof Solar Deck
#
Type Materials Area Area
Color Absor. Tested Insul.
Pitch
1
Gable or Shed Composition shingles 1166 82 184 f12 Medium 0.9 N 0
18.4 deg
ATTIC
/
V
#
Type
Ventilation Vent Ratio (/ in)
Area RBS IRCC
1
No attic
Unverded 0
1105 ft' N N
CEILING
#
Ceiling Type
R-Value
Area Framing Frac
Truss Type
i
CathedraVSingle Assembly (Unvented) 22
111106112 0.1
Wood
WALLS
Cavity Sheathing
Framing
Solar
#
Omt Adjacent To
Wag Type
R-Value Area R-Value
Fraction Absor.
_ 1
N Exterior
Frame- Wood
11 460 fN 0
025
0.8
2
E Exterior
Frame - Wood
11 240 fF 0
0.25
0.8
_ 3
S Exterior
Frame - Wood
11 460 fl? 0
025
0.8
4
W Exterior
Frame - Wood
11 240 ft2 0
025
0.8
6/11/2012 9:19 PM
DOORS
#
Omt
Door Type
Storms U-Value
Area
1
S
Insulated
None
0.29
21 ft
WINDOWS
Orientation shown is the entered, asBwR orientation.
/
Overhang
V #
Omt Frame
Panes
NFRC
U-Factor SHGC Storms
Area Depth Separation
Int Shade
Screening
_ 1
N Metal
Single (Clear)
Yes
0.65 0.55 N
20.5 R' 2 It 0 in 1 ft 0 in
HERS 2006
None
2
N Metal
Double (Clear)
Yes
0.65 0.55 N
6.625 W 2 It 0 in 1 it 0 In
HERS 2006
None
3
E Metal
Double (Clear)
Yes
0.65 0.55 N
14.58333 2 It 0 in 1 ft 0 in
HERS 2006
None
4
N Metal
Double (Clear)
Yes
0.65 0.55 N
12.5 R' 2 It 0 in 1 ft 0 in
HERS 2006
None
_ 5
E Metal
Double (Clear)
Yes
0.65 0.55 N
16.8 fV 2 ft 0 In 1 ft 0 in
HERS 2006
None
6
S Metal
Double (Clear)
Yes
0.65 0.55 N
7.49 tF 2 It 0 in 1 R 0 in
HERS 2006
None
_ 7
S Metal
Double (Gear)
Yes
0.65 0.55 N
10.33 W 2 it 0 in 1 ft 0 in
HERS 2006
None
8
W Metal
Double (Clear)
Yes
0.65 0.65 N
8.5 IF 2 It 0 In 1 it 0 in
HERS 2006
None
9
W Metal
Double (Clear)
Yes
0.65 0.55 N
7.451388 2 It 0 in 1 It 0 in
HERS 2006
None
10
E Metal
Double (Clear)
Yes
0.55 0.6 N
7.986111 0 It 0 in 0 It 0 in
HERS 2006
None
11
S Metal
Double (Clear)
Yes
0.55 0.6 N
7.986111 0 It 0 in 0 It 0 in
HERS 2006
None
12
S Metal
Double (Clear)
Yes
0.55 0.6 N
6 IF 0 It 0 in 0 ft 0 in
HERS 2006
None
INFILTRATION & VENTING
- Forced Ventilation -
Run Time
Fan
V Method
SLA
CFM 50
ACH 50 ELA EgLA
Supply CFM Exhaust CFM
Fraction
Watts
Default
0.00036
1044
7.08 57.3 107.8
0 ctm 0 cfm
0
0
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow SHR
Ducts
1
Central Unit
None
SEER: 14
22 kBtumr 660 elm 0.7
sys#1
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Ducts
1
Electric Strip Heat None
COP: 1
16 kBbdhr sys#1
HOT WATER SYSTEM
#
System Type
EF Cap
Use SetPrd
Conservation
1
Electric
0.95 30 gal 40 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None
None
ft'
6/11/2012 9:19 PM
DUCTS
—Supply—
—Retum—
Air
Percent
# Location R-Value Area
Location
Area
Leakage Type
Handler
CFM 25
Leakage
QN
RLF
1
Interior 6
40 ft'
Interior
10 ft'
Default Leakage
Interior
(Default)
(Default) %
TEMPERATURES
�Programable Thermostat Y
Ceiling Fans:
Cooling (())(()) Jan
Healing (X) Jan
(())(()) Feb
(X] Feb
Mar
(X] Mar
r
Apr
May
May
[[XX]] Jun
[X] Jun
[[))(()) Jul
(X) Jul
[[XX]] AugXX]]
(X1 Au9
Se
IX) SeP
[[XX�� Oct
[X) Oct
��XX�� Nov
(X] Nov
Dec
Dec
Vein ll�xll Jan
g
[[�X11 Feb
LL�X1l Mar
[[[���111
r [[[���111
may
LLJ�t1I Jun
11�X11 Jul
LL�R]) Au
[[�X1I Se
[[�R11 Oct
LL�X1I Nov
[[[�XXlll Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
80
80
78
78
78
78
78
78
78
78
78
80
78
PM
Goofing (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
. Healing(WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
68
68
68
68
66
68
66
PM
68
68
68
68
68
Heating (WEH)
AM
66
66
66
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
PM
68
68
68
6/112012 9:19 PM
FORM 1100A-08
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: 5606 Birch Dr PERMIT*
Fort Pierce, FI,
rnrrr ToeTlnM RFni ICTinw COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
N1106.AB.1.1
Maximum:.3 dm/s .ft. window area; .5 dm/s .ft. door area.
Exterior & Adjacent Walls
N1106.AB.1.2
Caulk, gasket, weatherstrip or seal between: windows/doors &
frames, surrounding wall; foundation & wall sole or sill plate; joints
between exterior wall panels at comers; utility penetrations;
between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is
installed that extends from, and is sealed to, the foundation to the
top plate.
Floors
N110B.AB.1.2
Penetrations/openings > 118" sealed unless backed by truss or
joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier
is installed that is sealed to the perimeter, penetrations and seams.
Ceilings
N1106.AB.1.2
Between walls & ceilings; penetrations of ceiling plane to top floor,
around shafts, chases, soffits, chimneys, cabinets sealed to
continuous air barrier, gaps in gyp board & top plate; attic access.
EXCEPTION: Frame ceilings where a continuous infiltration barrier
is installed that is sealed at the perimeter, at penetrations and
seams.
Recessed Lighting Fixtures
N1106.AB.1.2
Type IC rated with no penetrations, sealed; or Type IC or non -IC
rated, installed inside a sealed box with 1/2" clearance & 3" from
insulation; or Type IC with < 2.0 dm from conditioned space,
tested.
Multi-storyHouses
N1106.AB.1.2
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
N1106.AB.1.3
Exhaust fans vented to outdoors, dampers; combustion space
healers comply with NFPA, have combustion air.
nTHFR PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
N1112.AB.3
Comply with efficiency requirements in Table N1112.ABC.3
Switch or clearly marked circuit breaker (electric) or cutoff (gas)
must be provided. External or built-in heat trap required.
Swimming Pools & Spas
N1112.AB.2.3
Spas & heated pools must have covers (except solar heated).
Non-commercial pools must have a pump timer. Gas spa & pool
heaters must have a minimum thermal efficiency of 78%.
Heat pump pool heaters shall have a minimum COP of 4.0.
Shower heads
N1112.AB.2.4
Water flow must be restricted to no more than 2.5 gallons per
minute at 80 PSIG.
Air Distribution Systems
N1110.AB
All duds, fittings, mechanical equipment and plenum chambers
shall be mechanically attached, sealed, insulated and installed in
accordance with the criteria of Section N1110.AB.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
N7107.AB.2
Separate readily accessible manual or automatic thermostat for
each system.
Insulation
N1104.ABA
Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both
N1102.6.1.1
sides. Common ceiling & floors R-11.
mnlnmiQ•100ww
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 85
The lower the EnergyPerformance Index, the more efficient the home.
5606 Birch Dr, Fort Pierce, FI,
1. New construction or existing Existing (Projecte 9. Wa0 Types Insulation Area
2. Single family or multiple family Single-family a. Frame -Wood, Exterior R=11.0 1400.00 iN
b. WA R= ft'
3. Number of units, if multiple family 1 c. WA R= fF
4. Number of Bedrooms 1 d. N/A R= 11'
5. Is this a worst case?
6. Conditioned floor area
(ft-)
7. Windows"
Description
a. U-Factor:
Dbl, U=0.65
SHGC:
SHGC=0.55
b. U-Factor.
Dbl, U=0.55
SHGC:
SHGC=0.60
c. U-Factor.
Sgl, U=0.65
SHGC:
SHGC=0.55
d. U-Factor.
N/A
SHGC:
e. U-Fedor:
WA
SHGC:
8. Floor Types
a. Raised Floor
b. NIA
c. WA
No
10. Calling Types Insulation Area
a. Cathedral/Single Assembly (Umrented) R=2P.0 1106.00 IF
1106
b. WA R=
fP
Area
c. NIA R-
ft
84.28 ft'
11. Ducts
a. Sup: Interior ReL Interior AH: Interior Sup.
R= 6, 40 ft'
21.97 tP
12. Cool'mg systems
20.5D fP
a. Central Unit
Cap: 22.0 kBW/hr
SEER:14
fF
13. Heating systems
a. Electric Strip Heat
Cap:16.0 kBbft
fe
COP: 1
14. Hot water systems
Insulation
Area
a. Electric
Cap: 30 gallons
R=19.0
1106.00 ft'
EF: 0.95
R=
ft'
b. Conservation features
R=
ff'
None
15. Credits
CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspe ion. Otherwise, a new EPL Display Card will be completed
based on installed Code co liant f tures.
Builder Signature: Date:
Address of New Home: A4040� City/FL Zipv�F�3%��f 2
'Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA -
FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home
may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at
(321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified
Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the
Department of Community Affairs at (850) 487-1824.
"Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G
Gf the Florida Building Code, Residential, if not DEFAULT.
EnergyGauge® USA - RaRes2008