Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
wrightsoft• Load Short Form Entire House WebREPS,LLC Job: Palm Drive Residence Data: January 28, 2020 By. Josh Putman Plan: Palm Drive Residence 1892 Conmerm Aenue,Uero Beach, FL 32960 Phone:800A10-3280 Fac888-971-2999 Email: sales@mbmprhm=mftb:v .mbmpsMolemle.mm Limmse: CAC054709 Htg Clg Infiltration Outside db CF) 42 90 Method Simplified Inside db (OF) 70 75 Construction quality Semi -tight Design TO (OF) 28 15 Fireplaces Daily range M Inside humidity (%) 30 50 Moisture difference (grllb) 1 61 HEATING EQUIPMENT Make Goodman Trade HeatStdp Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.0 kW 27297 Btuh 27 OF 920 ct m 0.054 cfmBtuh 0.60 in H2O COOLING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Cond GSX160301F Coil ASPT30C14A AHRI ref 200825240 Efficiency 13.0 EER, Sensible cooling Latent cooling Total cooling Actual airflow Airflowfactor Static pressure Load sensible heat ratio 16 SEER 20424 Btuh 7176 Btuh 27600 Btuh 920 cfin 0.049 cfmBtuh 0.60 in H2O 0.75 ROOM NAME Area (fly Htg load (Btuh) Clg load (Btuh) HtgAVF (cfm) CIgAVF (cfim) Bed 2 197 3664 2700 197 133 c1st2 21 0 0 0 0 Bath 2 117 1289 1399 69 69 Bed 3 191 3015 2643 162 130 clst3 18 0 0 0 0 Kit Din LR 497 4832 8670 260 427 pnty 21 0 0 0 0 Bed 175 2292 2100 123 103 dst 1 18 0 0 0 0 on on90 1157 1no 57 Calculations approved byACCA to meet all requirements of Manual J 8 Ed. ^� Wrigh RighFSulleG Universal 201919.0.09 RSU16998 ...Wabitattr HumanityPSL%0130 Palm Drisemp Calc=WB FmnlDocrfams: N G®r, 202"n.2817A595 Page 1 Entire House 1335 17124 18670 920 920 Other equip loads 0 1707 Equip. @ 1.00 RSM 20377 Latentcooling 6921 o1n o7n V If1LJ �vv� �• �« �. �v.. Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -l41- wrightsoR' went-suite®unl�araalzotsts.a.osasutssss /lCiCp1...Webitalfor Humanity PSM030 Palm Diver p Cale-WIS Fmnt Doorfares:t 2020-Jao-2817A5.95 Page 2 Pro act Summary Job: Palm Dri1,e Residence -�- Wrightsoft° i ry Data: Janwry28,2020 Entire House BF. Josh PtNren WebREPS, LLC Plan: Palm Dd%e Residence 1892 Commerce Aenue, Vero Beach, FL 32960 Phone: 80MIO-3280 Fas888-971-2999 Email: sales@mbmpshracmmNPb:ww bmpsMolesale.mm License: CAC054709 Project• • For. Joseph Gianna, Habitat for Humanity Ft Pierce, FL Notes: Palm Drive Residence Florida Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Insidedb 70 OF Insidedb 75 OF Design TO 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 13853 Btuh Structure 13274 Btuh Ducts 3272 Btuh Ducts 5396 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 17124 Btuh Use manufacturer's data y Ratelswingg multiplier Equipmentsensibleload 1.00 20377 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 5389 Stuh 1 1530 Btu Central vent (0 cfm) Btuh Heatingg Coolingg (none) Area (fF) 1335 1335 Equipment latent load 6921 Btuh Volume (f?) 10678 10678 Airchanges/hour 0.31 0.16 Equipment Total Load (Sen+Lat) 27298 Btuh EquivAVF(clm) 55 28 Req. total capacity at 0.74 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Mfg. Trade Heat Strip Trade GOODMAN Model Cond GSX160301F AHRI ref Coil ASPT30C14A AHRI ref 200825240 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating input 8.0 kW Sensible cooling 20424 Btuh Heating output 27297 Btuh Latent000ling 7176 Btuh Temperature rise 27 OF Total cooling 27600 Btuh Actual air flow 920 clim Actual air flow 920 cfm Airflowfactor 0.054 dim/Btuh Airflowfactor 0.049 cfm/Btuh Static pressure 0.60 in H2O Staticpressure 0.60 in H2O Space thermostat \ Load sensible heat ratio 0.75 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -rW wrlghtsoft- 2020-Jan-2817U505 ,�j�,� •-. ...— Right-SWLVIL!ni,ersa1201919.0.09 RSU16998 Page 1 ._Wabitatfor Humanity PSULol30 Palm Driw"p Calc=FU8 FronlDoorfaces:14 Bed 2 Sheet 1 712x8Bath 2 Rdst Bed 3 7" 1 162cfrn 8" A, 12 x 12 197 cim 8" 8x8 107 cfm 8 x 8 107ch 412 6" — 6" 12 /5" 12 x 12 8 x 4 162 cfm r 69 cfm 7" Kit Din LR �12" Bx8 / 107 cfrn L 20 x 20 496cfin 14" 9„ 8x8 107 clip 6" 12 x 12 18 x 18 18x12 - Bed 1 Garage 8„ 6" 10 x 6 clst 123 cfm pnty 1ox6 109 cfm Bath 1 Job #: Palm Drive Residence Scale: 1 : 69 Performed by Josh Putman for. WebREP$, LLC Pagel Joseph Glenna 1892 Commerce Puenue RVM e9 UdVsMd2n9 Vero Beach, R-32960 VMRSU16398 R. Peke, FL Phone: 800�103280 Fax: 888-971-2999 �an231705a5 www.wbrepsWvlesae.com saes@vebrepshvae.com areiyPSL'int30Patrri�ri�enp e * wrightsoft° Duct System Summary Entire House WebREPS,LLC Job: Palm Drive Residence Data: January28,2020 W. Josh Putman Plan: Palm Dr%e Residence 1892 Commerce Aenue,Vero Beach, FL 32960 Phone: 800.81&328D Fax888-971-2999 Email: ssles@nebmpshva mm NPb:w . mbmpsMolesale.mm License: CAMM709 Project• • For. Joseph Gianna, Habitat for Humanity Ft Pierce, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowestftiction rate Actual airflow Total effeclive length (TEL) Heating 0.60 in H2O 0.24 in H2O 0,36 in H2O 0.198/0.162 in H2O 0.074 in/10011 920 ctrn 487 ft Cooling 0.60 in H2O 0.24 in H2O 0.36 in H2O 0.198/0.162 in H2O 0.074 in/100R 920 cfm Name Design (Btuh) Htg (cfm) Clg (dm) Design FIR Diam (in) H x W (in) Dud Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath I h 2032 109 57 0.081 6.0 OX 0 VIFx 18.2 225.0 st2 Beth2 h 1289 69 69 0.078 5.0 Ox0 VIFx 24.6 230.0 st4 Bed 1 h 2292 123 103 0.082 6.0 OX 0 VIFX 17.1 225.0 st2 Bede h 3664 197 133 0.075 8.0 Ox0 VIFx 32.7 230.0 st4 Bed h 3015 162 130 0.074 7.0 OXO VIFX 32.8 235.0 s14 Kit DinLR c 2168 65 107 0.088 6.0 OxO VIFx 20.5 205.0 st3 Kit onLR.A c 2168 65 107 0.087 6.0 OXO VIFX 18.0 210.0 st3 'Kit Din LR-B c 2168 65 107 0.084 6.0 Ox0 VIFx 25.7 210.0 st3 Kit Din LR-C C 2168 65 107 0.089 6.0 OXO VIFX 13.2 21010 st3 Trunk Htg Clg Design Veloc Diam H x W Dud Name Type (tiro) (cfm) FIR (fpm) (in) (in) Material Trunk st1 PeakAVF 920 920 0.074 613 15.0 12 x 18 RectFbg s12 PeakAVF 232 161 0.081 666 8.0 0 x 0 VinlFlx st1 s14 PeakAVF 428 332 0.074 545 12.0 0 x 0 Vinift st3 st3 PeakAVF 688 759 0.074 710 14.0 0 x 0 VinlFlx st1 wrightsoft' 202aJen-28170506 Ri9hl-Suite®Univerca1201919.0.09 RSU16998 Pagel ...Wabitatfor Humanly MUM Palm Drh,enip Calc=1418 FrontDoortacas: N ■ Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam HxW Stud/Joist Dud Name Size (in) (crm) (cfm) (it) FR (fpm) (tn) (in) Opening (in) Mat Trunk rb3 Ox0 232 161 112.3 0.144 526 9.0 Ox 0 VIFx rt1 rb4 Ox 0 329 496 94.7 0.171 632 12.0 Ox 0 VIFx rt1 rb1 Ox 0 197 133 205.7 0.079 564 8.0 Ox 0 VIFx rt2 rb2 Ox0 162 130 219.6 0.074 606 7.0 Ox 0 VIFx rt2 Return Trunk Detail Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (crm) (cim) FR (fpm) (in) (in) Material Trunk rt1 PeakAVF 920 920 0.074 409 15.0 18 x 18 RectFbg rt2 PeakAVF 359 263 0.074 457 12.0 0 x 0 VinlFlx rt1 wrightsoW 2026Jan-281795:06 ...�'— Right-Suite®Unkerml201919.0.09RSU16998 Paget �.�...Wabitatbr HumanityPSLU130 Palm Driva.mp Calc=W8 Front Doortaws:N