Property Information Building Information
Owner: James Pierson Wind Zone: 160 MPH.
Address: 1216 NW Winters Creek Rd Exposure Category: D
Palm City,FL 34990 Minimum Building Dimension: 3 ft.
Mean Roof Height: 25 ft.
Risk Category: I1
Design Pressure Calculations
OpeningLocation Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 272.25 154 16 34.7 -38.4
2 Int 189.25 145 12.5 35.9 -39.7
3 End 146.25 145 12.5 36.6 -43.9
4 End 40.25 141 12 40.0 -50.6
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.