Loading...
HomeMy WebLinkAboutProduct Approval STORM License a chobee 9801 vd, 4047 Okeechobee Blvd,Ste 106, SMART West Palm Beach, 33409 Phone(561)229-00404 8 w}vw.StormSmartSE.com of Southeast Florida Property Information Building Information Owner: James Pierson Wind Zone: 160 MPH. Address: 1216 NW Winters Creek Rd Exposure Category: D Palm City,FL 34990 Minimum Building Dimension: 3 ft. Mean Roof Height: 25 ft. Risk Category: I1 Design Pressure Calculations OpeningLocation Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 272.25 154 16 34.7 -38.4 2 Int 189.25 145 12.5 35.9 -39.7 3 End 146.25 145 12.5 36.6 -43.9 4 End 40.25 141 12 40.0 -50.6 Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1