Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982- (772) 462-1SS3 MAY ® 5 2020 )Certification for Design Load Compliance SIProjea Project Address: L)ba (fC:) 1J -3q "GGC)--3 Permit #: '/ Occupancy Type: 3 Construction Type: r b INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commerclal with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida �C: / 1 i/1 Code Sixth Edition with 20 l7 Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed _Partially Enclosed Open 3. Risk Category:_I II III_IV Exposure Category:_B C D 4. Design Wind Veloci mphrl ASD LRFD'/ End Zone Width: ZJ ft 5. Mean Roof Height �� ft Roof Pitch: `f :12 Parapet:y ft e 6. Component j Cladding Desjg Pressures Used- �F, based on 10s33 @35'MRH, clearly labeLon all plan openings ): Zone 1 - ' (' Zone 2" NN Zone 3:� 7 �i �'! Zone 4: •-3 /., 3 Zone 5: - i/U�jSFj Garage: -�j z77� 7. Design Loads: Floor.Al' PSF � Roof/DeadPSF Roof/Live:�Bglcony, PSF Dock: 7 PSF Deck: PSF Stairs• ��/ PSF Fenc, • INS PSF Railings i PSF S. Were Shear Walls Considered For Structured/ Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided?2LYesNot Applicable Explain Why Not: 10. Design Soil Bearing.Pressure: �O PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: g1711z� 140A 1n& y[/!/ Print Name , , Cert # & Co. C���f1 1. Signature, Date, and Sea[ Company Name & Address Revised 12/07/2018