HomeMy WebLinkAboutengineeringT.E. S C H LITT E N G I N E E R I N G March 6, 2019 Mr. Gary Stepalavich, MCP/CFM Building Code Administrator 2300 Virginia Avenue Ft. Pierce, FL 34982 Subject: Site Inspection — Exterior Wall Yates Funeral Home 7951 US 1 Port St. Lucie, Florida Engineer's Project Number: 191012 Dear Mr. Stepalavich, MCP/CFM: As requested, we completed our inspection of the subject site on February 13, 2019. The purpose of our inspection was to inspect and document the conditions of the structure after a vehicular accident that affected part of the bearing wall on the south side. Our inspection consisted of a visual survey of the damaged concrete masonry wall from the interior and exterior. Our visual inspection is not expected to reveal elaborate defects, which are not evident by deterioration exposed to view or evident to the trained eye as the structure now stands. It must be understood that the Engineer can only provide certification of the conditions of the structures within the limits of the structural inspection performed. The following is a description of our findings based on our inspection of the property: • The impact affected the south wall of the structure and covers an area of approximately 5' by 3'. • Approximately five courses of block were damaged at the bottom of the wall. • The wall does not appear to have lost its verticality. We did not find evidence of damage to the vertical filled cells. • No structural deficiencies were detected at the wall -roof connection or the bond beam. The contractor shall repair the wall by adding one (1) vertical filled cell, drilled and epoxied to both the top bond beam and the slab, splice as needed with a 30 lap. The remainder of the wall will be typical unreinforced masonry. All methods and materials shall meet Florida Building Code. Based on our inspection, to the best of our knowledge and belief, the engineer certifies that except the local area affected, the structure is structurally sound. 1555 Indian River Blvd. Suite B-145 T: 772.360.4998 Vero Beach, FL 32960 StructuralFL@gmail.com Mr. Stepalavich March 6, 2019 Page 2 I have attached two pictures below for reference. Should you have any questions regarding the above subject, please call. Very truly yours, Terence Schlitt, P.E. FL P.E. # 81238 CA #32295 TS/al cc: Mr. Thomas Conway, Owner Inspection Photos �\\N11111II/////// ��IS F.?G E- --Cyr / 81238 Marchi . 0019 ��0, `, STATE OF 4V RC O 10? — \ xS/ONAL 1555 Indian River Blvd. Suite B-145 T: 772.360.4998 Vero Beach, FL32960 StructuralFL@gmail.com