BLOWER DOOR TEST FORM
House Infiltration Test c( rtif ea :Bon.
Prescriptive and Pe6^ FMance Method
BaerMI--E #:
u4 New construction — Co n plete
1Q01
-0Lf35
€ Existing —After Additior-:
House Infiltration Test Results
CFM (50) = �) 0 9 SLC Climate Zone 2
Volume = I :r -7 -1 !t Q Test Date: yam_
ACN (5fl) = CFM (50) it GO J Volume = Mechm7Jca1 l/entilation required less than 3 ACm
Passing results must be & ACH (50) or less
( Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the pary conducting the test and
provided to the code official. Testing shall be performed at any time of ter creation of all penetrations of the building
thermal envelope.
F13C, Residential
Where the air infiltration rate of a dwelling unit is less than —3air changes per hour when tested with a blower door at a
Pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name: Pro -Duct Services
Address: 1915 P.io Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordancMith SeAion R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Marin Klein
License/Certification##: 5061633