HomeMy WebLinkAboutReview Comments'9.74' G UOorot5 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 20025 Southern Star Dr City / State / Zip: Fort Pierce, FI 34945 Parcel#: 2215-700-0009-000/8 Zoning: REVIEW COMMENTS DWI ED Page 1 NOV 15 2017 Owner(s): Bertrand Laidier Jr / Charlotte Almore / Michael E Bell li Jurisdiction: SAINT LUCIE COUNTY Lot#: 7 APPLICATION INFORMATION Permit Number: 1709-0086 Stones: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Michael J Miranda Business Name: Group One Construction & Dev Inc Business Addr: 10302 S Federal Hwy Ste 164 City / State / Zip: Port St Lucie, FI 34952 Review Tvoe ADDRESSING ASSIGNMENT Comment: DOCUMENTS MISSING 9/2012017 Comment: 9/22/2017 Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) 10/2/2017 Comment: Comment: 10/212017 Comment: 10/2/2017 Block: Automatic Sprinkler System? No Fax Number: 772-334-0804 Status Reviewed By Date Started COMPLETE Lydia Galbraith 912212017 PENDING Lashahna Ingram VEG PERMIT IN DRAWER UNDER'A" ALMORE. NO FEE SUB AGREEMENTS FOR MECHANICAL AND ROOF. COMPLETE Lynn Swartzel 911812017 COMPLETE Lashahna Ingram 916/2017 INCOMPLETE William Durden 11/8/2017 Email: Mikemiranda3074@AoI.Co m Date Completed Date Released 912512017 9/2512017 911812017 9/18/2017 91612017 91612017 • PLEASE CLARIFY THE DESCRIPTION OF MULTIPLE HOUSES SPECIFIED IN THE ENERGY CALC'S. STRUCTURE IS A SINGLE-FAMILY RESIDENCE. • LINE SEVEN ON THE ENERGY CALC'S ARE INCORRECT, MULTIPLE TYPES OF WINDOWS ON PLANS PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2014 FLORIDA BUILDING CODE ENERGY CONSERVATION 5TH EDITION. SUBMITTED WALL DETAIL SHOWS R-13 WALL INSULATION, ENERGY CALC'S DO NOT SHOW THE INSULATION OF THE SEPARATION WALL. PLEASE CORRECT. 6. SHOW INTERIOR WALL DETAIL FOR THE SEPARATION OF THE GARAGE TO HOUSE INCLUDING INSULATION AND R VALUE. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. Planning& Development Services REVIEW COMMENTS Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462.6443 r. m .nl• PA(:F 3 OF 5 wwnr)WR CHOC AND THE I I-FAr1TOR ARF THE RAMF FOR At I FFNFRTRATION AND THE NFRC IS MARKED YES. PLEASE SUBMIT THE ENERGY PERFORMANCE SHEETS FROM THE MANUFACTURE. PAGE 3 OF 5 WILL NEED TO BE CORRECTED. 10/212017 • PLEASE SUBMIT THE ENERGY PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC FOR EACH GLAZED OPENING SHOWING COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION. 101212017 Comment: ENERGY CALC'S ONLY CALL OUT ONE WATER HEATER, PLANS SHOW 3. PLEASE CLARIFY. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. Comment: THE PRODUCT APPROVALS THAT WERE SUBMITTED IS FOR THE METAL ROOF, PLEASE SUBMIT THE ROOF UNDERLAYMENT. 10/2/2017 • PLEASE SUBMIT THE ROOF UNDERLAYMENT PRODUCT APPROVALS IN DUPLICATE. MEETING THE REQUIREMENTS OF CHAPTER 9 SECTION R905.10.5 SUBSECTION R105.10.5.2 OF THE 2014 FLORIDA BUIDING CODE. 10/212017 Comment: • THE ENERGY CALULATIONS MUST HAVE THE PREPARERS ORIGINAL SIGNATURE PLEASE FURNISH NEW ENERGY CALULATIONS WITH ORIGINAL SIGNATURE PER 107.1 OF THE 2010 FLORIDA BUILDING CODE PLANS EXAMINER ELECTRIC INCOMPLETE Joe Cielo 10/412017 101412017 Comment: PLS ADD THE QUANTITY OF APPLIANCES ITEMIZED WITHIN THE ELECTRICAL LOAD CALCULATIONS: EX: [ 2 ] DISHWASHERS [ 31 MECHANICAL SYSTEMS ETC 10/4/2017 Comment: CHECK LOADS FOR APPLIANCES • NOT CONSISTENT WITH THE NEC' APPLIANCES ARE MISSING FROM THE LIST PER THE PLANS PLANS EXAMINER MECHANICAL INCOMPLETE Joe Cicio 10/312017 Comment: HOUSE 1, 2 AND MAIN HOUSE SQUARE FOOTAGES ON SUMMARY SHEETS MUST MATCH THE 10/3/2017 WORKSHEETS 10/3/2017 Comment: SHOW THE OPENING SIZE AND CFM'S FOR FAMILY ROOM DROP IN HOUSE #1 Comment: SHOW THE LOCATIONS OF ALL MECHANICAL EQUIPMENT ON PLANS' SHOW THE REQUIRED TIE DOWN DETAILS FOR THE EXTERIOR EQUIPMENT PER FBCM 301.15 TO MEET THE DESIGN WIND SPEED AND EXPOSURE'•• UNIT #1 AND UNIT #2 WILL NOT FIT IN THE ATTIC LOCATIONS AS SHOWN ON THE MECH 10/3/2017 PLANS' PLEASE CO-ORDINATE THESE LOCATIONS WITH THE TRUSS MANUFACTURERS ENGINEER AND THE ENGINEER OF RECORD • SHOW ALL DETAILS ON PLANS PER FBCR M 1305.1.3 W/ PAN DETAILS AND DRAINS Comment: PLEASE MAKE REFERENCE TO ALL MECHANICAL SYSTEMS ON ALL DOCUMENTS AS SYSTEM 1, SYSTEM 2 10/3/2017 AND SYSTEM 3 • THIS IS A SINGLE FAMILY DWELLING' PLEASE LABEL THESE SYSTEMS ON THE MECHANICALPLANS Comment: MANUALS AND ENERGY CALCS SPEC R-4 OPEN CORE FOR EXTERIOR WALLS' PLANS SPEC R-9 CORE 10/3/2017 FILLED • PLS CORRECT ONE OR THE OTHER Comment: IF ANY MECHANICAL UNITS ARE IN THE ATTIC TRUSS COMPANY TO SHOW ON LAYOUTS WITH APPROVAL 10/3/2017 OF LOADING' ENERGY CALC IS SPECIFYING ALL [ 3 ] UNITS IN ATTIC 10/312017 Comment: ENGINEER TO STATE THE CORRECT ADDRESS ON ALL PLANS, ENERGY CALCS AND MANUALS 10/4/2017 Comment: ENERGY CALCS ARE SIGNED INCORRECTLY AND MUST ALL BE ORIGINAL SIGNATURES PLANS EXAMINER PLUMBING INCOMPLETE Joe Ciclo 10/412017 10/4/2017 Comment: SHOW THE WATER HEATER SIZES ON PLANS AND ADD ADDITIONAL HEATERS TO ENERGY CALCS 10/412017 Comment: SHOW THE REQUIRED PAN AND DRAIN SIZES ON PLANS FBCR P 2801.5 Comment: ENGINEER TO NOTE THE TESTING STANDARDS FOR THE DRAINAGE AND VENT PIPING ON PLANS • SEE 10/412017 FBCR P 3002.1 PLANS EXAMINER REVIEW COMPLETE William Durden 101212017 11/812017 111812017 Comment: ZONING REVIEW INCOMPLETE Lydia Galbraith 9/2212017 Comment: PLEASE PROVIDE 2 UPDATED SIGNED AND SEALED SURVEYS WITH PROPOSED CONSTRUCTION, 9/22/2017 SETBACK, PROPOSED FFE, ELEVATION OF CENTER LINE ROAD, SEPTIC AND WELL. 9/22/2017 Comment: PLEASE PROVIDE 2 FLOOR PLANS AND 2 SURVEYS STAMPED FOR APPROVAL BY HEALTH DER -Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462.6443 REVIEW COMMENTS 9/22/2017 Comment: PLEASE PROVIDE HEALTH DEP PERMIT FOR SEPTIC AND WELL Comment: SUBMITTED WARRANTY DEED IS NOT THE LATEST DEED. PROPERTY IS OWNED BY 3 PERSONS THAT 9/22/2017 ARE JOINT TENANTS. Comment: BUILDING PLANS GIVE THE IMPRESSION THE BUILDING TO BE A MULTI FAMILY BLD WITH 3 UNITS. AG 5 ZONING DISTRICT DOESN'T ALLOW MULTI FAMILY. TO BE ABLE TO PROCEED AS SFR THE PLANS SHOULD 9/2212017 NOT REFER TO MAIN, HOUSE 1 AND HOUSE 2. THE SAME FOR THE MANUAL J'S THEY SHOULD NOT REFER TO MULTIPLE HOUSES. ALL INDICATION TO MULTIPLE UNITS SHOULD BE REMOVED FROM THE PLANS. Comment: PLEASE BE AWARE THAT WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW DUE TO MISSING INFORMATION. THE PLANS WILL PROCEED THROUGH THE REVIEW PROCESS, HOWEVER, THE PERMIT 912212017 WILL NOT BE ISSUED UNTIL ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. PLEASE BE AWARE THAT ADDITIONAL COMMENTS FROM DIFFERENT DEPARTMENTS MIGHT BE APPLICABLE.