ELECTRICALPLANINSTALL STANDBY GENERATORFORQUALIFER: MARK CROSS
LICENSE # EC13001174
MC
A-2
CONTRACTOR:
CODE INFORMATION
CONSTRUCTION TYPE:
TYPE
OCCUPANCY:
SINGLE FAMILY RESIDENCE
JURISDICTION:
ST. LUCIE COUNTY
APPLICABLE BUILDING CODES:
•FLORIDA BUILDING CODE, SIXTH EDITION (2017)
•FLORIDA ENERGY CODE, SIXTH EDITION (2017)
•FLORIDA MECHANICAL CODE, SIXTH EDITION (2017)
•FLORIDA PLUMBING CODE, SIXTH EDITION (2017)
•EXISTING BLDG. FLORIDA BUILDING CODE, SIXTH EDITION (2017)
•FLORIDA ACCESSIBILITY CODE, SIXTH EDITION (2017)
•FLORIDA FIRE PREVENTION CODE, SIXTH EDITION
•2014 NATIONAL ELECTRIC CODE
•NFPA 101 LIFE SAFETY CODE, 2015 EDITION
•2013 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS
NOTES:
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FURNISH AND
INSTALL ALL NECESSARY COMPONENTS FOR THE PROPER
OPERATION OF ALL SPECIFIED SYSTEMS, REGARDLESS OF
WHITHER THOSE COMPONENTS ARE SHOWN ON THE DRAWINGS
OR NOT. CONTRACTOR SHALL ALSO VERIFY THAT SPECIFIED
COMPONENTS ARE COMPATIBLE WITH OTHERS WITHIN THE SAME
SYSTEM ANO WITH THE SYSTEM ITSELF.
LEGAL DESCRIPTION:
PORTOFINO SHORES-PHASE TWO- (PB 43-33) LOT 193
PARCEL ID #: 1312-502-0094-000-7
PROJECT NO.: G200108
DATE: 6-17-2020
MARCOPE, LLC
5818 LYDA LANE
ORLANDO, FL. 32839
CGC1514240 EC13001174
GENERAL ELECIRICAL NOTES:
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL
ELECTRICAL CODE AND OTHER APPLICABLE CODES AND
STANDARDS.
2. THE CONTRACTOR SHALL SATISFACTORLIY REPAIR/REPLACE
EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF
HIS WORK.
3. APPROVAL SHALL BE OBTAINED FROM THE ENGINEER PRIOR
TO CUTTING OR DRILLING ANY STRUCTURAL SUPPORT MEMBER .
4. MINIMUM WIRE SIZE SHALL BE #12 THWN UNLESS OTHERWISE
NOTED ON PLANS .
5. ALL CONDUCTORS SMALLER THAN #8 SHALL BE COPPER
UNLESS OTHERWISE NOTED ON PLANS .
6. ALL EXPOSED CONDUCTORS SHALL BE RUN IN CONDUIT.
7. ALL MATERIALS SHALL BE U.L. APPROVED.
8. CONTRACTOR SHALL SEAL ALL FIRE RATED PENETRATIONS
WITH A FIRE SEALANT EQUAL TO THE RATINGS OF THE
PENETRATION.
9. RISERS ARE DIAGRAMATIC ONLY. THEY DO NOT SHOW EVERY
BEND REQUIRED FOR THE INSTALLATION
10. THESE DRAWINGS ARE A GUIDE FOR THE INSTALLATION OF
ELECTRICAL SERVICE. THE ELECTRICAL CONTRACTOR IS
RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM.
11. ALL CABLES SHALL BE RUN WITHOUT SPLICES. EXCEPT AS
OTHERWISE INDICATED.
12. ALL PULL AND JUNCTION BOXES SHALL BE ACCESSIBLE AT ALL
TIMES.
13. EXACT POINT AND METHODS OF CONNECTIONS TO
EQUIPMENT'S SHALL BE DETERMINED IN FIELD.
14. ALL WORK SHALL BE DONE IN A NEAT ANO WORKMANLIKE
MANNER.
ALL ELECTRICAL / PLUMBING / MECHANICAL
EQUIPMENT SHALL BE ABOVE REQUIRED ELEVATI ON
AS PER CHAPTER 11C-5(F)(4)
GAS SHALL BE INSTALLED AT LEAST 1 0 FT FROM
ANY EXTERNAL SOURCE OF IGNITION (e.g.
ELECTRICAL EQUIPMENTS, A/C COMPRESSORS, ETC.)
GENERATOR EXHAUST TERMINATION POINT SHALL
FBC-R-M1602.2
GENERATOR PACKAGE UNIT
OUTLINE SPECIFICATIONS
THIS GENERATOR PACKAGE SHALL CONSIST OF
A 120/240V, 22 KW, SINGLE PHASE, SOUND
ATTENUATED, FULLY PACKAGED, GUARDIAN
AIR-COOLED GAS ENGINE GENERATOR SET
INCLUDE:
BATTERY CHARGING ALTERNATOR
MICROPROCESSOR CONTROL
FACTORY LOADBANK TESTED
100A MAINLINE CIRCUIT BREAKER
SOUND ATTENUATED, WEATHERPROOF ENCLOSURE, 59db
@ 23 FEET COMPOSITE MOUNTING PAD
UL 2200 LISTED
NATURAL GAS OR LP GAS FUEL
ELECTRONIC GOVERNOR
ENCLOSED CRITICAL GRADE MUFFLER
OUTLINE SPECIFICATIONS
AUTOMATIC TRANSFER SWITCH 150A, TWO (2) POLES,
120/240 VOLTS, SINGLE PHASE, 22 KAIC. IN A NEMA 3R
ENCLOSURE W/ 150A M.C.B, SERVICE ENTRANCE
EQUIPMENT RATED
A PERMANENT SIGN SHALL BE PLACED AT THE
ELECTRICAL SERVICE ENTRANCE EQUIPMENT THAT
INDICATES THE LOCATION OF ON-SITE OPTIONAL
STANDBY POWER SOURCE.
A PERMANENT SIGN SHALL BE PLACED AT THE TRANSFER
SWITCH LOCATION INDICATING THE SEQUENCE OF
OPERATION TO START THE GENERATOR AND TRANSFER
THE ELECTRICAL LOADS.
BOND GENERATOR FRAME TO BE GROUNDED PER NEC
250GI FUEL PIPE SHALL BE BONDED AS PER NEC
250.104(B) I I TRANSFER SWITCH IS NON-SEPARATELY
DERIVED SYSTEM.ENERATOR FRAME AND GAS PIPE ONLY
ALL ELECTRICAL / PLUMBING / MECHANICAL EQUIPMENT
SHALL BE ABOVE REQUIRED ELEVATION AS PER CHAPTER
11C-5(F)(4)
( 3) 3/8 DIA. X 3" EXP. ANCHORS
DAVID THOMPSON5411 LAKE PLACE DRIVEFORT PIERCE, FL. 34951NORTH
EXISTING METER
150 AMP 120/240 VOLT
SINGLE PHASE
EXISTING PANEL
150 AMP 120/240 VOLT
SINGLE PHASE
NEW SERVICE RATED
TRANSFER SWITCH
150 AMP 120/240 VOLT
SINGLE PHASE
1'-6"
8'-2"
34'-0"
NEW 22 KW AIR COOLED
GENERATOR 100 AMP 120/240
VOLT 2 POLE SINGLE PHASE
BREAKER MOUNTED ON A 4"
APPROVED PRECAST PAD
12'-0"
12'-0"
500 Gallon underground
propane tank