HomeMy WebLinkAboutRevision; Energy Code.r,
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDINGTO,%TRUCTION
Florida Department of Business and Professional Regulation -Residential od
Project Name: ALMORE RESIDENCE
Builder Name: TC CUSTOM HOM S
- id
Street: 20025 SOUTHERN STAR DRIVE
Permit Office: ST LUCIE COUNT ST. Lucie County, Permitting
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (5160.0 sqft.)
Insulation Area
2. Single family or multiple family Singlefamily
a. Concrete Block- Ext Insul, Exterior
R=4.1 4920.00 ft2
b. Frame- Wood, Adjacent
R=11.0 240.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 10
d. N/A
R= ft2
-
,Is
10. Ceiling Types (5897.0 sgft.)
Insulation Area
S. this a worst case? No
a. Under Attic (Vented)
R=30.0 5897.00 ft2
6. Conditioned floor area above grade (ft2) 5941
J. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(652.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 200
a. U-Factor: Dbl, U=0.32 384.00 ft2
b. Sup: Attic, Ret: Attic, AH: UNIT 2
6 140
SHGC: SHGC=0.19
c. Sup: Attic, Ret: Attic, AH: UNIT 3
6 140
b. U-Factor: Dial, U=0.32 250.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.22
a. Central Unit
46.5 SEER:16.00
b. Central Unit
29.0 SEER:16.00
c. U-Factor: Dial, U=0.28 18.00 ft2
c. Central Unit
29.0 SEER:16.00
SHGC: SHGC=0.21
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
b. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth: 1.500 ft.
c. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average SHGC: 0.202
14. Hot water systems
a. Electric
Cap: 150 gallons
8. Floor Types (5941.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 5941.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/FloorArea:''0.110 Total Proposed Modified Loads: 168.86
PASS
Total Baseline
Loads: 181.03
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance w h the Florida Energy
specifications covered by this
OFT1;E'SpgpA
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED -BY-
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 55�
y�
e
I hereby certify that this building, as design , is in mpliance
Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT
BUILDING OFFICE
DATE:
DATE:
r
4
- Compliance requires certification by the air handler unit manufacturer that the al h4nlsi
IS
Jut
[leyI I
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
ALL PROJECTS require an envelope leakage test report with envelope leakage no greater than 7 ACH50 (R402.4.1.2).
A'IIe Copy ECEIVE
..1
4/6/2018 12:26 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant So ar '� APR 3 0 ,,2018
BY:
FORM A405-2014
PROJECT
Title:
ALMORE RESIDENCE
Bedrooms: 10
Address Type:
Street Address
Building Type:
User
Conditioned Area: 5941
Lot #
Owner Name:
Total Stories: 1
Block/SubDMsion:
# of Units:
1
Worst Case: No
PlalBook:
Builder Name:
TC CUSTOM HOMES
Rotate Angle: 0
Street:
20025 SOUTHERN STA
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
County.
St. Lucie
Jurisdiction:
Whole House Fan:
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Ews6ng:
New (From Plans)
Comment:
CLIMATE
_ /
Design Temp
Inl Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2794 27940
2
Block2
1517 15170
3
Block3
1630 16300
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
UNIT 1
2794 27940 Yes 0
4
1 Yes
Yes
Yes
2
UNIT2
1517 15170 Yes 0
3
1 Yes
Yes
Yes
3
UNIT 3
1630 16300 Yes 0
3
1 Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
UNIT 1 147 It 0
2794 ft2
_---
1 0
0
2 Slab -On -Grade Edge Insulation
UNIT 2 11311 0
1517 ft2
___
1 0
0
3 Slab -On -Grade Edge Insulation
UNIT 3 123 It 0
1630 ft2
___
1 0
0
ROOF
/
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 6435 ft2 0 it- Medium
0.2
No 0.9
No 0
22.6
'Type
LvATTIC
#
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 5941 ft2
N N
4/6/2018 12:26 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software - Page 2 of 5
FORM R405-2014
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented)
UNIT 1
30
Blown
2760 ft'
0.11
Wood
_
2
Under Attic (Vented)
UNIT2
30
Blown
1517 ft'
0.11
Wood
3
Under Attic (Vented)
UNIT 3
30
Blown
1630 ft2
0.11
Wood
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing Solar
Below
Space
1
NW
Exterior
Concrete Block- Ext Insul
UNIT 1
4.09999
31
10
310.0 ft'
0
0 0.2
0
_ 2
NE
Exterior
Concrete Block- Ext Insul
UNIT 1
4.09999
46
10
460.0 ft'
0
0 0.2
0
_ 3
SE
Exterior
Concrete Block- Ext Insul
UNIT 1
4.09999
39
10
390.0 ft'
0
0 0.2
0
4
SW
e
Exterior
Concrete Block -Ext Insul
UNIT
4.09999
51
10
510.0 ft2
0
0 0.2
0
_ 5
NW
Exterior
Concrete Block - Ext Insul
UNIT2
4.09999
54
10
540.0 ft2
0
0 0.2
0
_ 6
NE
Exterior
Concrete Block -Ext Insul
UNIT2
4.09999
26
10
260.0 ft2
0
0 0.2
0
_ 7
SE
Exterior
Concrete Block- Ext Insul
UNIT2
4.09999
45
10
450.0 ft'
0
0 0.2
0
_ 8
SW
Exterior
Concrete Block- Ext Insul
UNIT2
4.09999
26
10
260.0 W
0
0 0.2
0
_ 9
NW
Exterior
Concrete Block -Ext Insul
UNIT
4.09999
65
10
650.0 ft2
0
0 0.2
0
10
NE
Exterior
Concrete Block -Ext Insul
UNIT
4.09999
33
10
330.0 ft2
0
0 0.2
0
_ 11
SE
Exterior
Concrete Block- Ext Insul
UNIT 3
4.09999
43
10
430.0 112
0
0 0.2
0
_ 12
SW
Exterior
Concrete Block- Ext Insul
UNIT 3
4.09999
33
10
330.0 ft2
0
0 0.2
0
13
NE
Garage
Frame - Wood
UNIT
11
1
10
10.0 ft2
0
0 0.2
0
14
SE
Garage
Frame - Wood
UNIT
11
23
10
230.0 ft2
0
0 0.2
0
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
_
1
- NE
Insulated UNIT 2
None
.27
3
6 8
20 ft2
2
SW
Insulated UNIT 3
None
.27
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Orin ID
Frame Panes
NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
_
1
NE 2
Vinyl Low-E Double
Yes
0.32
0.22
60.0 ft'
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
2
SE 3
Vinyl Low-E Double
Yes
0.32
0.22
30.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
3
SE 3
Vinyl Low-E Double
Yes
0.32
0.19
24.0 ft'
1 ft 6 in
1 ft4 in
Drapes/blinds
Exterior 5
4
BE. 3
Vinyl Low-E Double
Yes
0.32
0.19
48.0 ft2
1 ft 6 in
1 ft 4 in
Drapes blinds
Exterior 5
5
SW 4
Vinyl Low-E Double
Yes
0.32
0.22
40.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
_
6
SW 4
Vinyl Low-E Double
Yes
0.28
0.21
6.0 ft'
1 ft6ln
1 ft4 in
Drapes/blinds
Exterior 5
_
• 7
NW 5
Vinyl Low-E Double
Yes
0.32
0.19
60.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
_
.8
NW 5
Vinyl Low-E Double
Yes
0.32
0.19
48.0 ft'
1 ft 6 In
1 ft 4 in
Drapes/blinds
Exterior 5
_
9
,10
NE 6
Vinyl Low-E Double
Yes
0.32
0.22
20.0 ft2
1 ft 6 In
1 ft 4 in
Drapes/blinds
Exterior 5
SE 7
Vinyl Low-E Double
Yes
0.32
0:22
30.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
_
11
SE , 7
Vinyl Low-E Double
Yes
0.32
0.19
20.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
_
12
SW 8
Vinyl Low-E Double
Yes
0.28
0.21
6.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5 .
13
NW 9
Vinyl Low-E Double
Yes
0.32
0.19
60.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
4/6/2018,12:26 PM , EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
WINDOWS
Orientation shown is the entered. P
Wall
V '#
Omt
ID
Frame
Panes
NFRC
U-Factor
SHGC
,14
NW
9
Vinyl
Low-E Double
Yes
0.32
0.19 4
_ •15
NE
10
Vinyl
Low-E Double
Yes
0.32
0.19 2
_ 16
NE
10
Vinyl
Low-E Double
Yes
0.28
0.21
17
SE
11
Vinyl
Low-E Double
Yes
0.32
0.22 3
18
SW
12
Vinyl
Low-E Double
Yes
0.32
0.19 2
19
SE
3
Vinyl
Low-E Double
Yes
0.32
0.19 1
20
NE
6
Vinyl
Low-E Double
Yes
0.32
0.19 2
21
SE
7
Vinyl
Low-E Double
Yes
0.32
0.22 2
# Floor Area
1 483 ft2
# Scope Method
1 Wholehouse Proposed ACH(50)
0
loft 11
ACH ACH 50
.3247 7
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat
None
COPA
34 kBtu/hr
1
sys#1
•, 2
Electric Strip Heat
None
COPA
27 kBtu/hr
2
sys#2
3
Electric Strip Heat
None
COP:l
27 kBtu/hr
3
sys#3
COOLING SYSTEM
7 #
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR Block
Ducts
1
Central Unit
None
SEER: 16
46.5 kBtu/hr 1395 cfm
0.8 1
sys#1
2
Central Unit
None
SEER: 16
29 kBtu/hr
870 cfm
0.8 2
sys#2
3
Central Unit
None
SEER: 16
29 kBtu/hr
870 cfm
0.8 3
sys#3
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric None
Garage
0.98 150 gal
130 gal
120 deg
None
4/6/2016 �12:26 PM
EnergyGauge@ USA- FlaRes2014 Section R405.4.1 Compliant Software
Page 4 of 5
2FO'Rfvi R405-2014
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System
Model # Collector Model
# Area
Volume
FEF
None
None
ft2
DUCTS
_ /
—Supply—
—Return
Air
CFM 25 CFM25
HVAC#
V #
Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT OUT
ON
RLF
Heal Cool
1
Attic
6
200 fl2
Attic
20 ft2
Default Leakage
Garage
(Default) c(Default) c
1 1
2
Attic
6
140 ft2
Attic
14 ft2
Default Leakage
UNIT 2
(Default) c(Default) c
2 2
3
Attic
6
140 ft2
Attic
14 ft2
Default Leakage
UNIT 3
(Default) c(Default) c
3 3
TEMPERATURES
Programable[ T]hermostatrx]�JN
Fans:
Cr
Heating ( Jan
Feb
[[ ]]
[�
Mar
Aprfreiling
ay
n[X]
Jun ]Jul
[X�
]Aug
[�]
l 1 Sep
NovX
[[Xj] Dec
Venting I 1 Jan
O Feb
! 1
(Rl
Mar
Apr [
May
Jun 1 Jul
E
E 1 Aug
l 1 Sep Oct
Nov
[ ] Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8 9
10
11
12
Cooling(WD)
AM
78
78
78
78
78 78
78
78 78
78
78
78
PM
78
78
78
78
78 78
78
78 78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78 78
78
78 78
78
78
78
PM
78
78
78
78
78 78
78
78 78
78
78
78
Heating(WD)
AM
68
68
68
68
68 68
68
68 68
68
68
68
PM
68
68
68
68
68 68
68
68 68
68
68
68
Heating(WEH)
AM
68
68
68
68
68 68
68
68 68
68
68
68
PM
68
68
68
68
68 68
68
68 68
68
68
68
4/6/2018 12:26 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6
'-.,, &Ia
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: ALMORE RESIDENCE Builder Name: TC CUSTOM HOMES
Street: 20025 SOUTHERN STAR DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
Rim -joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
4/6/2018 12:27 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
-w F?OtVI R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the EnergyPerformance Index, the more efficient the home.
20025 SOUTHERN STAR DRIVE, FORT PIERCE, FL,
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned Floor area (W)
7. Windows"
Description
a. U-Factor:
Dbl, U=0.32
SHGC:
SHGC=0.19
b. U-Factor:
Dbl, U=0.32
SHGC:
SHGC=0.22
c. U-Factor:
Dbl, U=0.28
SHGC:
SHGC=0.21
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
New (From Plans)
Single-family
1
10
No
5941
Area
384.00 ft-
250.00 W
18.00 fF
ft'
1.500 ft.
0.202
Insulation
Area
R=0.0
5941.00 ft'
R=
ft'
R=
ft'
9. Wall Types
a. Concrete Block- Ext Insul, Exterior
b. Frame - Wood, Adjacent
c. N/A
d. N/A
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
c. NIA
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
b. Sup: Attic, Ret: Attic, AH: UNIT 2
c. Sup: Attic, Ret: Attic, AH: UNIT 3
12. Cooling systems
a. Central Unit
b. Central Unit
c. Central Unit
13. Healing systems
a. Electric Strip Heat
b. Electric Strip Heat
c. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features whi ili be installed (or exceeded)
in this home before final inspection. Otherwise, a new Display Card will be completed
based on installed Code compli features.
Builder Signature: Date: (?
Address of New Home:
City/FL Zip:
Insulation
R=4.1
R=11.0
R=
R=
Insulation
R=30.0
R=
R=
Area
4920.00 ft-
240.00 ft'
ft'
ft'
Area
5897.00 ft'
ft'
ft'
R ft'
6 200
6 14C
6 140
kBtu/hr Efficiency
46.5 SEER:16.00
29.0 SEER:16.00
29.0 SEER:16.00
kBtu/hr Efficiency
34.0 COP:1.00
27.0 COP:1.00
27.0 COP:1.00
Cap: 150 gallons
EF: 0.98
None
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
"'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/6/2P1812:27 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1