Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division -- --- - — -- 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Wade Jurney Homes -1612 Project Address: 022LWP009 - 7002 Penny Lane Ft. Pierce, FL 34951 Permit#: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category:_I X II _III IV Exposure Category:B X C _D 4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3.6 ft 5. Mean Roof Height 11 ft Roof Pitch: 4 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1:+19.3,-30.6 Zone 2:+19.3,-53.3 Zone 3:+19.3,-78.9 Zone 4:+33.5,-36.3 Zone 5: +33.5,-44.8 Garage: +31.7/-38.6 7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50 PSF 8. Were Shear Walls Considered For Structure? Y Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Y Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the f�li /bole structural portions of the building codes currently adopted and enforced by St. Lucie County. _I ELVq\\gert�f' y cyyal elements depicted on these plans provide adequate resistance to the design I '� James G. Friling * ; !�° 77 * = Print Name Cent # & Co. Cert Auth. a PE #77824 COA #27228 ��3 SATE OF •[;ram " f Mulhe+ Kul structural En >ignatd�// o�i�i 1 ,� m Company Name &Address Bering - 300 Brookside Ave, Ambler, PA 19002 Revised 12/07/2018 E Cop'y MAR 19 2019 F��'