Loading...
HomeMy WebLinkAboutProduct Approval "'" r4� 'r�- ei ' a.1p� e "Md , vrrm JXt; a `e BCIS Home I Log In i User Registration i Hot7opics Submit Surcharge Stats&Facts j Publications i Contact Us i BCIS Site Map Links j 'Search i b k y r"(o. s Product Approval USER:Public User Product Approval Menu>Product or Application Search>implication L(st>Application Detail ! `—�'""I—' PEI}IER FL# FL10124-R26 ` JUL2020INHERE x: , Application Type Revision Code Version 2017 1. Lucie-County, Permitting Application Status Approved - Comments Archived Product Manufacturer GAF 'OPY Address/Phone/Email 1 Campus DrivJO54 Parssppany,N] (800) 7,66-3411 mstieh@gaf.com Authorized Signature Robert Nieminen Ireith@nemoetc.com Technical Representative William Broussard - Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (800)766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ` Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/16/2022 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10124_R26_COI_2020_01 COI NIEMINEN.odf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 r Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/12/2020 Date Validated 02/13/2020 Date Pending FBC Approval 02/16/2020 Date Approved 04/07/2020 Summary of Products FL# Model,Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10124 R26 II 2020_02 FINAL ER GAF ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10124-R26.p-df Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Reports FL10124_R26_A_E_2020_02_FINAL_ER GAF ASPHALT SHINGLES FL10124-R26.pdf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe..._....__..._..._. __...__ _.. ._.. WEMO etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION GAF Evaluation Report 01506.01.08-1128 1 Campus Drive FL10124-R26 Parsippany,NJ 07054 Date of Issuance:01/03/2008 (800)766-3411 Revision 28:02/03/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: •.,�1,,,,.: :: � The facsimile seal appearing was authorized by Robert Robert J.M.Nieminen,P.E. T�•:,= � �:'. ••—• z.•• Nieminen,P.E.on 02/03/2020.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 '`:•'t��� y' electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEM01etc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO1 etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEM01 etc.nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019,NEMO ETC,LLC OMEMO etc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF,have demonstrated compliance with the following Sections of the 611 Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2.. STANDARDS,,; Section Pro a Sit andarad Year 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995 REFERENCES,` , Entity Examination Reference Date PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI(TST 5878) ASTM D1970(QuickStart) GAF-340-02-01 03/13/2012 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 PRI(TST 5878) Wind Driven Rain GAF-895-02-01 11/20/2018 PRI(TST 5878) Wind Driven Rain GAF-896-02-01 11/20/2018 PRI(TST 5878) ASTM D3462 GAF-897-02-01 11/08/2018 PRI(TST 5878) ASTM D3462 GAF-898-02-01 11/08/2018 PRI(TST 5878) ASTM D3462 GAF-899-02-01 11/15/2018 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 01NK06632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001 UL(TST 1740) ASTM D3161 OINK37122 12/18/2001 UL(TST 1740) ASTM D3462 01NK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 OSNK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 NEMO ETC,LLC Evaluation Report 01506.01.08-1128 Certificate of Authorization#32455 CH EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1126 GAF Asphalt Roof Shingles Revision 28:02/03/2020 Page 2 of 7 ONEMOjetc. Entity Examination Reference Date UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008 UL,LLC.(TST 9628) ASTM D3161 4788698165 03/24/2008 UL(TST 1740) ASTM D3161,D3462 07CA5S908 04/01/2008 UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010 UL(TST 1740) ASTM D3462 10CA07264 05/27/2010 UL(TST 1740) ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL LLC. TST 9628 ASTM D3161 D7158 D3462 12CA58151 02 15 2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013. UL,LLC.(TST 9628) ASTM D3161,D71S8,D3462 4786875675 07/17/2015 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4788717529 09/09/2016 UL,LLC.(TST 9628) ASTM D3161 4788669132 12/13/2018 UL,LLC.(TST 9628) ASTM D3161 4788891098 02/14/2019 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4788932264 08/16/2019 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4789115488 08/16/2019 UL,LLC.(TST 9628) ASTM D3161 4788959558 10/17/2019 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786508528 11/01/2019 UL,LLC.(TST 9628) ASTM D3161 4789132672 11/27/2019 UL,LLC.(QUA 9625) Quality Control Service Confirmation 10/18/2018 4 PRODUCT::DESCRIPTION 4.1 ACCESSORY STARTER STRIPS: 4.1.1 Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBlockerT" Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 QuickStart° Peel &Stick Starter Roll is a is a mineral-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6-inch or less. Meets ASTM D1970. 4.1.3 StarterMatchlm Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon®and Grand Sequoia®series asphalt shingles. StarterMatch"m are installed as the second starter for Grand Canyon®and Grand Sequoia®series installations. Meets ASTM D3462. NEMO ETC,LLC Evaluation Report 01S06.01.08-R28 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R26 GAF Asphalt Roof Shingles Revision 28:02/03/2020 Page 3 of 7 ONEMO etc. 42 ASPHALTSHINGLES: 4.2.1 Marquis WeatherMax®,Royal Sovereign®and Sentinel®are a fiberglass reinforced 3-tab asphalt roof shingles. 4.2.2 Camelot®, Camelot® II, Fortitude TM, Glenwood TM Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield°, Grand Sequoia® AS, Sienna®, Timberline® American Harvest®, Timberline® AH, Timberline°ArmorShield® II,Timberline®AS II,Timberline® Natural Shadow®,Timberline® NS,Timberline® HD, Timberline® HDZTM, Timberline® Cool Series, Timberline® CS, Timberline® Ultra HD, Timberline® UHD and Woodland®are fiberglass reinforced,laminated asphalt roof shingles. 4.2.3 SlatelineT"'is a fiberglass reinforced 5-tab asphalt roof shingle. 4.3 HIP&.RIDGE SHINGLES: 4.3.1 Seal-A-Ridge®Protective Ridge Cap Shingles(fka,Seal-A-Ridge®Ridge Cap Shingles),Seal-A-Ridge°ArmorShield®, Seal-A-Ridge®AS and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 5' LIIVI,ITATI,ONS , 5.1 This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBlocker'm Premium Eave/Rake Starter Strip Shingles are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicatingthe shingles are acceptable for use in all wind zones up to Vasd=150 mph(V„It=194 mph). 5.4.2 The GAF asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for use in all wind zones Up to Vasd=150 mph(V,,it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. . 5.4.3 The GAF hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to Vasa=150 mph(VuIt=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. NEMO ETC,LLC Evaluation Report 01S06.01.08-R28 Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R26 GAF Asphalt Roof Shingles Revision 28:02/03/2020 Page 4 of 7 ONEMOletc. 6 _: INSTALLATION 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 GAF asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and GAF published installation instructions. 6.2 STARTER SHINGLES OR STARTER STRIP: 6.2.1 Installation of Pro-Start" Eave/Rake Starter Strip Shingles,WeatherBlockerl Premium Eave/Rake Starter Strip Shingles and QuickStart®Peel&Stick Starter Roll shall comply with the GAF current published instructions. 6.3 ASPHALTSHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions,using minimum four(4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Camelot®,Camelot"11,Grand Canyon®,Grand Sequoia®,Grand Sequoia®IR,Grand Sequoia®ArmorShield®, and Woodland®require minimum five(5)nails per shingle. ➢ Slatelinelm requires minimum six(6)nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.2.1 Fastening for Fortitude",Timberline®AH,Timberline®CS and Timberline®HDZi";slopes 2:12 up to 21:12 39-3/8'(1 m) 11-518'-14.518'(295mm-372mm{ 113,8 14-5ff(296mm-372inm) (13mm-64nw) [�,72-1fY(13nm-64mm) 13-1/4' r.;:• TARGET NAIL ZONE ZONA OBJETIVO DE CLAVADO 6 7/8° 5-13/16'-7-5/6'(148mm-194mm) (174 lml!I{ 7 STANDARD NAILING PATTERN: Nail shingles approximately 6 7/8"(174 mm)from bottom of shingle,in nailing area,as shown.Nails must not be exposed.Not for use on Mansard roofs(21:12 slope and above). 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required. Contact the GAF for details. MEMO ETC,LLC Evaluation Report 01SO6.01.08-R28 Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R26 GAF Asphalt Roof Shingles Revision 28:02/03/2020 Page 5 of 7 ^ ^ `- ONEMOjetc. 6.3�1 Fastening for FortitudeTm,Timberline"AH,TimberUne"B and TimberlinewHDZ'";slopes greater than Z1:12 ENHANCED NAILING PATTERN:* El I These shingles MUST be nailed a nominal 6'(152 mm)from bottom of shingle,above the cut-outs,as shown.Nails must not be exposed. 6.4 Hip&RIDGE SHINGLES: 6.4.1 Installation of Seal-A-Ridgel Protective Ridge Cap Shingles (fka, Seal-A-RidgeO Ridge Cap Shingles) shall comply with the GAF current published instructions with a minimum two(2) nails, minimum 3/8-inch head diameter Nall located 6-7/8-inch back from the exposed end Clavo Clouer and 0.5-inch from the edge. 6.42 Installation of Seal-A-RidgeO ArmorShield" and Seal-A-RidgeO AS shall comply with the GAF current published instructions with a minimum two(2) nails,minimum 3/8-inch head diameter, per shingle located 6 to 6.5-inch back from the exposed end and 1to 2-inch from the edge and nominal 0.35'inch diameter beads of Henkel "LncitaPL33O Roof&Flashing Sea|ant". MINOR M, Mail NEW ETC,uc Evaluation Report o15o6.o1.o8-xm Certificate of A"m"riz"o""m245, 0 EDITION(aoo)mcwnm'xxozEVALUATION Fu0124-R26 GAF Asphalt Roof Shingles xem,mnuo:ou/o3/zom Page omr ONEMOjetc. 6.4.3 Installation of Timbertex®Premium Ridge Cap 11.51 Sealant Shingles shall comply with GAF current 1 (292mm) 1 �Seilante (25 mm) (_ 2�5, } Enduit d6ianch6itg published instructions with a minimum two(2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn "NP1 Gun F Grade Polyurethane Sealant" or Henkel "PL i► ;-' • Roofing and Flashing Sealant". Nail Cleve 12' Clouer (305 mm) 9' (229 mm) 12' (305 mm) 6.4.3 Fasteners shall be in accordance with GAF published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 7; 10ELING 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8.`, BUILDING PERMIT.-REQUIREM As reENTS ,. , wired b th.. .. q y e Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. '9.' IVIANUFACTURINGPLANT5t Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20- 3 QA requirements. 10 QUALITY ASSURANCE ENTITY UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com END OF EVALUATION REPORT- NEW ETC,LLC Evaluation Report 01506.01.08-R28 Certificate of Authorization#32455 6TH EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1126 GAF Asphalt Roof Shingles Revision 28:02/03/2020 Page 7 of 7 i - �_,....- 4L.^'� ~l•}•S � ii'ii3fth-�. BCIS Home i Log In i User Registration i Hot Topics Submit Surcharge I Stats&Facts i Publications i Contact Us BCIS Site Map i Links i Search i Florida lw �7�4'11 Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL2346-R7 Application Type Revision ,J��j_ � 7 702Q Code Version 2017 Application Status Approved', 1-('Cie County, Permitting Comments Archived amp Product Manufacturer Warrior Roofing a ngC 0 Address/Phone/Email 3050 Warrior Roa' Tuscaloosa,AL 35404 (205) 553-1734 Ext115 Steven@WarriorRoofing.net Authorized Signature Steven Crew Steven@WarriorRoofing.net Technical Representative Steven Crew Address/Phone/Email 3050 Warrior Road Tuscaloosa,AL 35404 (205)553-1734 Ext1024 Steven@WarriorRoofing.net Quality Assurance Representative Steven Crew Address/Phone/Email 3050 Warrior Road Tuscaloosa,AL 35404 (205) 553-1734 Ext1024 Steven@WarriorRoofing.net Category Roofing Subcategory Underlayments Compliance Method Test Report Testing Lab PRI Construction Materials Technologies, LLC Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 10/05/2021 Validated By Jesus Gonzalez, P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL2346 R7 COI PRI CMT Cert of Independence.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D226 2009 ASTM D4869 2016 Equivalence of Product Standards Certified By Approved Testing Lab FL2346 R7 EEguiv FBC 2017 Standards Eouivalencv.Ddf Product Approval Method Method 1 Option B Date Submitted 01/17/2018 Date Validated 01/17/2018 Date Pending FBC Approval 01/17/2018 Date Approved 04/10/2018 Summary of Products FL# Model,Number or Name Description 2346.1 #15 and #30 roofing felt ASTM D 226 Tested Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2346 R711 InstallationInstructions.pdf Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies, LLC Impact Resistant: N/A Test Reports Design Pressure: N/A FL2346 R7 TR 15A Test Report.Pdf Other: Primary roof covering should be installed immediately FL2346 R7 TR 30A Test Report.Ddf after felt. Roofing felt is not intended to be an unprotected weathering surface. 2346.2 15w and 30w roofing felt ASTM D 4869 Tested Limits of Use Installation Instructions Approved for use in HVHZ: No F1_2346_R7IInstallationInstructions.pdf Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies, LLC Impact Resistant: N/A Test Reports Design Pressure: N/A FL2346 R7 TR 15w Test Report.pd� Other: Primary roof covering should be installed immediately FL2346 R7 TR 30w Test Report.pdf after felt. Roofing felt is not intended to be an unprotected weathering surface. Back N t Contact Us::2601 Blair Stone Road.Tallahassee FL 32329 Phone:$50-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ! , -71 ®Rr. M Credit Card; Safe.. _ i WARRIOR® ROOFING MANUFACTURING P.0.BOX 40185•TUSCALOOSA,AL35404•PHONE(205)553.173i 4 FAX(205)553.1755 193 LEROY ANDERSON ROAD•MONROE.CA30655•PHONE(770)207-0695•FAX(770)20U775 ® 323 DEVELOPMENT AVENUE•CHAMBERSBURG,PA 17201•PHONE(717)709-0323•FAX(717)709-0027 Roofing Felt Installation Recommendations CV Be aware that roofing felt should not be walked upon prior to fastening into position. Proper safety equipment is recommended for all installations. Also,the roof decking should be clear of debris and moisture prior to installation of the roofing felt. Roofing felt should be installed from the bottom of the roof in horizontal layers to increase the water shedding ability of the felt. The initial layer of felt should be installed to cover the bottom edge of the decking,from edge to edge. Overhang is not required. Anchor the top comer of the felt after it has been properly positioned and roll the felt out across the roof. Pay careful attention to roll the felt out smoothly,avoiding wrinkles as you move across the roof. The top edge of the felt should be fastened no less than every eight inches. The middle and bottom edge should also be fastened no less than every eight inches. Fasteners should be applied no less than every eight inches along the eaves. The next-course of felt should also be aligned with the roof edge and should overlap the previous course two inches(sometimes referred to as head lap)..In the event you get to the end of a roll prior to getting to the opposite edge of the roof,begin a new roll with a four inch overlap over the end of the prior roll(sometimes referred to as end lap). The same fastening pattern used on the middle and bottom of the initial course should be used for each subsequent course. For the top of each subsequent course,fasten intermittently to hold the top edge in place until the next course is applied. The fasteners in the bottom of the next course will hold the top of the previous course securely. Continue up the roof in this manner. Be sure to firmly fasten the top of the final course if it terminates at the top edge of the-roof. Otherwise,overlap the felt over the ridge and secure then begin at the bottom of the other side of the ridge and repeat the process. In valleys,lay a vertical section of roofing felt the length of the valley prior to the installation of the horizontal runs of roofing felt. If you use more than one section of roofing felt in a valley,be certain to start at the bottom and overlap each:pubsequent length a minimum of two inches as you move up the valley tex.. shedding. 21 M ,,, Y1 tr In the event some wrinkles are created while fastening down a course of felt,slice the wrinkles and fasten them flat to the deck. Then seal the cuts with waterproofing cement. Installation of the primary roof covering(ex.Shingles)is recommended immediately after felt installation. NOTE: LOCAL BUILDING CODES MAY REQUIRE A DIFFERENT FASTENING PATTERN AND/OR SPECIFIC FASTENER TYPES THAN RECOMMENDED BY THESE INSTRUCTIONS. PLEASE CONTACT YOUR LOCAL BUILDING CODE ADMINISTRATOR FOR THE EXISTENCE OF REGIONALLY SPECIFIC FASTENING REQUIREMENTS. - ",�.5 . .�hi. •.Y` x E �'r�M�.tt�ti�.,r=�',ytZ Q�r,1ca::: --� t"43. � ° T��l�..:�`''+n�'0 `r.7t'9�rah,'E.• . ��}�p .�s�r��= may,ia:tr�,•.e°n: ,�a," MEMO etc. Certificate of Authorization#/32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION .O. GAF Evaluation Report 01506.01.08-R28 1 Campus Drive FL10124-R26 Parsippany,NJ 07054 Date of Issuance:01 03 2008 PP Y, / / (800)766-3411 Revision 28:02/03/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 t CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). NEMO1 etc.requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: '•,'^�. The facsimile seal appearing was authorized by Robert Robert J.M.Nieminen P.E. ,u�. c••� Nieminen,P.E.on 02/03/2020.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 ''. !t�.'.�;.„.'�•" electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO Ietc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for.that purpose. ©2019,NEMO ETC,LLC ONEMOletc. .00 1. SCOPE Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF,have demonstrated compliance with the following sections of the 61h Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Ube set forth herein. 2. STANDARDS: . Section Property Standard Year 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D71S8 2011 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entity Examination Reference Date PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI(TST 5878) ASTM D3462 GAF-OS9-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI(TST 5878) ASTM D1970(QuickStart) dAF-340-02-01 03/13/2012 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 PRI(TST 5878) Wind Driven Rain GAF-895-02-01 11/20/2018 PRI(TST 5878) Wind Driven Rain GAF-896-02-01 11/20/2018 PRI(TST 5878) "ASTM D3462 GAF-897-02-01 11/08/2018 PRI(TST 5878) ASTM D3462 GAF-898-02-01 11/08/2018 PRI(TST 5878) ASTM D3462 GAF-899-02-01 11/15/2018 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 01NK06632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001 UL(TST 1740) ASTM D3161 01NK37122 12/19/2001 UL(TST 1740) ASTM D3462 OINK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/12/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 OSNK27924 02/10/2006 UL(TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 NEMO ETC,LLC Evaluation Report 01506.01.08-1128 Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R26 GAF Asphalt Roof Shingles Revision 28:02/03/2020 Page 2 of 7 IYNEMOjetc. Entity Examination Reference Date UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM 03161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 OBCA06100 03/13/2008 UL,LLC.(TST 9628) ASTM D3161 4788698165 03/24/2008 UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161,D3462 09CAlOS92 03%26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010 UL(TST 1740) ASTM D3462 IOCA07264 05/27/2010 UL(TST 17401 ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IOCA53934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 4788717529 09/09/2016 UL,LLC.(TST 9628) ASTM D3161 4788669132 12/13/2018 UL,LLC.(TST 9628) ASTM D3161 4788891098 02/14/2019 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4788932264 08/16/2019 UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 4789115488 08/16/2019 UL,LLC.(TST 9628) ASTM D3161 4788959558 10/17/2019 UL,LLC.(TST 9628) ASTM D3161,D7158,P3462 4786508528 11/01/2019 UL,I.I.C.(TST9628) ASTM D3161 4789132672 11/27/2019 UL,LLC.(QUA 9625) Quality Control Service Confirmation 10/18/2018 4. PRCIDU6 MSCRIPT 6N.::; 4.1 ACCESSORY STARTER STRIPS: 4.1.1 Pro-Start®Eave/Rake Starter Strip Shingles and WeatherBlocker"Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 QuickStart® Peel &Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced,self-adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6-inch or less. Meets ASTM D1970. 4.1.3 StarterMatchT""Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon®and Grand Sequoia®series asphalt shingles. StarterMatchT""are installed as the second starter for Grand Canyon®and Grand Sequoia®series installations. Meets ASTM D3462. NEMO ETC,LLC Evaluation Report 01506.01.08-R28 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R26 GAF Asphalt Roof Shingles Revision 28:02/03/2020 Page 3 of 7 Ulm NEMO I etc. 4.2 ASPHALT SHINGLES: -• 4.2.1 Marquis WeatherMax",Royal Sovereign"and Sentinel"are a fiberglass reinforced 3-tab asphalt roof shingles. 4.2.2 Camelot", Camelot® II, Fortitude'"", Glenwood1m, Grand Canyon", Grand Sequoia", Grand Sequoia® IR, Grand Sequoia" ArmorShield", Grand Sequoia® AS, Sienna", Timberline® American Harvest®;'Timberline" AH, Timberline"ArmorShield" II,Timberline" AS II,Timberline" Natural Shadow",Timberline" NS,Timberline" HD, Timberline" HDZ'", Timberline" Cool Series, Timberline" CS, Timberline" Ultra HD, Timberline" UHD and Woodland"are fiberglass reinforced,laminated asphalt roof shingles. 4.2.3 Slateline'"is a fiberglass reinforced 5-tab asphalt roof shingle. 4.3 HIP&RIDGE SHINGLES: 4.3.1 Seal-A-Ridge"Protective Ridge Cap Shingles(fka,Seal-A-Ridge"Ridge Cap Shingles),Seal-A-Ridge"ArmorShield", Seal-A-Ridge"AS and Timbertex"Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 Pro-Start"Eave/Rake Starter Strip Shingles and WeatherBlocker'"" Premium Eave/Rake Starter Strip Shingles are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(V„It=194 mph). 5.4.2 The GAF asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(Valt=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3,and a mean roof height of 60 feet or less. Calculatigns by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.3 The GAF hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to Vasa=150 - mph(Vast=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. NEW ETC,LLC Evaluation Report 01506.01.08-1128 Certificate of Authorization#32455 G'"EDITION(2017)FBC NON-HVHZ EVALUATION FL30124-R26 GAF Asphalt Roof Shingles Revision 28:02/03/2020 Page 4 of 7 MNEMO4 etc. 6. INSTALLATiOM 6.1 GENERAL' _. _... 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC Sections 15.07.2.3,1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 GAF asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and GM published installation instructions. 6.2 STARTER SHINGLES OR STARTER STRIP: 6.2.1 Installation of Pro-Start® Eave/Rake Starter Strip Shingles,WeatherBlockerT" Premium Eave/Rake Starter Strip Shingles and QuickStart®Peel&Stick Starter Roll shall comply with the GAF current published instructions. 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions,using minimum four(4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: Camelot®,Camelot"11,Grand Canyon®,Grand Sequoia®,Grand Sequoia®IR,Grand Sequoia®ArmorShield®, and Woodland®require minimum five(5)nails per shingle. > Slateline-requires minimum six(6)nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.2.1 Fastening for Fortitude'"',Timberline®AH,Timberline®CS and Timberline®HDZ7";slopes 2:12 up to 21:12 39.3!8`(1m) 11.5.'C•fe•�.3'i295nvr.-3'2remi 11-5.8'•Id5g1'G�jSnm;-37hnm1 12'-2-h2';13mn•Q40;9j 1.2'-2-1`T I13mm-54= 'gym TARGET NAIL ZONE ZONA OSJETIVO DE CLAVADO 6 7/8' S-13.116--7-5. (I40mm-194mmi +1,m,,. s STANDARD NAILING PATTERN: Nail Shingles approximately 6 718"(174 mm)from bottom of shingle,in nailing area,as shovel.Nails must not be exposed.Not for use on Mansard roofs(21:12 slope and above). 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required. Contact the GAF for details. NEMO ETC,LLC Evaluation Report 01506.01.08-R28 Certificate of Authorkatlon#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R26 GAF Asphalt Roof Shingles Revision 28:02/03/2020 Page 5 of 7