HomeMy WebLinkAboutProduct Approval; Standby GeneratorGENERAC®
RECEIVED
16/20/22 kW AIN 15 2620 GUARDIAN SERIES
Permitting Department Residential Standby Generators
MINI_ st' `""e County. Air -Cooled Gas Engine
INCLUDES:
• True Power- Electrical Technology Standby Power Rating
• Two Line LCD Multilingual Digital FILE COPY Models G007Model G00703-1 (Aluminum - Bisque) - 16 kW 60 Hz
Model G007035-1 (Aluminum -Bisque) -16 kW 60 Hz
Evolution- Controller (English/Spanish/ Models G007039-1, G007038-1 (Aluminum - Bisque) - 20 kW 60 Hz
French/Portuguese)
Models G007043-2, G007042-2 (Aluminum -Bisque) - 22 kW 60 Hz
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
ST.LUCIE COUNTY
200 Amp Service Rated Smart Switch.
PLAN REVIEW
See Page 5 for Details.
• Electronic Governor
Bl.DG:
• Standard yY-Fl"' Remote Monitoring
DAB
• System Status & Maintenance Interval LED Indicator
• Sound Attenuated Enclosure
DATEZQ /L 0
• Flexible Fuel Line Connector PLUMB:
• Direct -To -Dirt Composite Mounting Pad DATE:
• Natural Gas or LP Gas Operation MECH:
DATE:
• 5 Year Limited Warranty
• Listed and Labeled by the Southwest Research Institute allowing
installation as close as 18' (457 mm) to a structure.'
*Must be located away from doors, windows, and fresh air
intakes and in accordance with local codes.
hnps://assels.swn.org//ibraryry/DirectoryO/LrstedProductsl
Construcbonlndustry/W3 DoC_204_73204-01-0i Rev9.pdf
FEATURES
O INNOVATIVE ENGINE DESIGN& RIGOROUS TESTING area[ the headofGeneric's O
success in providing the most reliable generators possible. Generac's G-Force engine
lineup offers added peace of mind and reliability for when you need it the most The
G-Force series engines are purpose built and designed to handle the rigors of
Wended run times in high temperatures and extreme operating conditions.
O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O
form produce less than 5%Total Harmonic Distortion for utility graliry power. This allows
confident operation of sensitive electronic equipment and microchip based appliances,
such as variable speed HVAC systems.
O TESTCNITERIA:
J PHOTOTYPETESTED J NEMA MGI-22 EVALUATION
J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY
GENERAC'
CLI US QUI&ME&T - r%
Note: CUL certification only applies to unbundled units and wits padded with
limited circuit switches. Units packaged with the Smart Switch are UL coddled in
the USA only.
SOUDSTATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
This state-of-the-art power maximizing regulation system is standard on
all Genemc models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque4natching the surge loads to the engine. Digital
voltage regulation at ±1 %.
SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service [mow -how for the entire unit, from the
engine to the smallest electronic component.
O GENERAC TRANSFER SWITCHES: Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
O MOBILE LINK- REMOTE MONITORING: FREE with every Guardian Series Home
s arafty,MOBILE
LINKgenerator. Allows you to monitor theMONITORIN status:FILE Withyour
horn Guardian
anywhere in the "' GENERAC ,s•w
world using a smadphone, tablet, or PC. Easily access inforodon such as the current PROMISE m `RM '� _
operating status and mainlemnce alerts. Connect your accourd to your authorized service
dealer fortist, friendlyand proactive service. With Mobile Unk you are taken care of before
the next power outage.
16/20/22 kW
GENERAC
available accessories
Model # Product Description
The Wi-R enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank Mon.
6007005-0 Wi-R LP Fuel Level Monitor Baring the LP tank's fuel level is an important step in making sure your generator is ready to run during an
unexpected power failure. Status alerts are available through afree application to notify when your LP tank
is in need of a refill.
G005819-0
26R Wet Cell Battery
Every standby generator requires a battery to start the system. Genersc offers the recommended 26R wet
cell battery for use with all air-cooled standby product (excluding PewerPact®).
6007101-0
Battery Pad Warmer
The pad warmer rests underthebattery. Recommended for use ifto temperature regularly fags below
0 OF 08 °C). (Not necessary for use with AGM -style batteries).
G007102-0
Oil Warmer
00 warmer slips directly over the oil filer. Recommended for use IT the temperature regularly falls below 0 'F
(-18 "C).
G007103-1
Breather Warmer
The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers
only in climates where heavy icing occurs.
G005621-0
Aelaliary Transfer Switch
The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load
Contact Kit
you may not need. Nat compatible with 50 amp pre -wired switches.
Fascia Base Wrap ICit
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a
G007027-0 - Bisque
(Standardsleek,
on 22 kW)
contoured appearance as well as offering protection from rodents and insects by covering the lifting
holes located in the base.
Ifthe generator enclosure is scratched or damaged, it is important to touch up the pant to protect from
G005703-0 - Bisque
Paint Kt
future corrosion. The paintIdtIncludesthenecessarypaGdtoproperlymaintainortouchupagenerator
enclosure.
{
G006485-0
Scheduled Maintenance Kit
Generse's scheduled maintenance kits provide all the hardware necessary to perform complete routine
maintenance on a Generac automatic standby generator.
Smart Management Module
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to Increase its
G006873-0
(50Amps)
power management capabilities. it provides additional power managementflelo'bility not found in any other
power management system
dimensions & UPCs
Dimasaims slwwn areaprradrrek. Refer installation manual for axed i inwnsimm DO NOT USE THESE DI AMIGNS FOR INSTALLATION PURPOSES.
l SEDEV1EW
r'nsee
FAOMr V70v
Model
UPC
G007035-1
696471074161
G007036-1
696471074154
G007037-1
696471074178
G007038-1
696471074185
G007039-1
696471074192
G007042-2
696471074208
G007043-2
696471074215
GENE RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
@201aGmre PowerSystmm.ticMdghbresPn&AAspnfficgausaresublecttodwwwftutrt0u.PadNo.1800800IO"(8101118)
GENERAC
16/20/22 kW switch options
Limited Circuits Switch Features
• 16 space, 24 circuit, breakers not included.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of load,100% equipment rated, both inductive and
resistive.
• 2-pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil design.
• Rated for both copper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMAAIL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with V standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effective
install.
Dimensions
Height
width
Depth
H1
112
Wl
W2
in
26.75
30.1
10.5
13.5
6.91
mm
679.4
764.3
266.7
343.0
175A
wee Ranges
conductor Lug
Neueal Lug
Ground Lug
1/0-#14
210-#14
2/0-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (OPM).
• Intelligently manages up to four air conditioner loads with no additional
hardware.
• Up to four more large (240 VAC) loads can be managed when used in
conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for last, clean connections.
• Rated for all classes of load,100% equipment rated, both inductive and resis-
tive.
• 2-pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMAJUL 311 aluminum outdoor enclosure allows for indoor or outdoor mount-
ing flexibility.
Dimensions
200 Amps 120240, to
Open Transition Service Rated
Height
Width
Depth
H7
H2
wi
W2
in
26.75
1 30.1
10.5
13.5
6.91
min
679.4
764.3
266.7
343.0
1744
Model
G007036.1(16MN)
111o.of Poles
12 r
Cooenl Rating (Amps)
100
v�olhage Isfing(VAC)
120/240.10
U01ityVollage Monitor (Fined)`
-P kvp
-0mpoot
80%
65%
flenonto UOlity`
appmx: 155e' c
Exercisesbi-weeHy for 5 minutes'
Standard
ULUsted
standard
Talal CircuilsAvailable
24
Tandem Weaker Capabilities
8 tandems
Circuit Breaker Protected
Available RMS Symmetrical
Fault Current @ 250 Volls
10,000
*Function of Evolution Controller
Exercise can be set to weekly or monthly
Model
0007037-1 (16 WJ)/GU07039.1 (20 Nil
G007043.2 (22 kYA
No. of Pales
2 _ .a
current Rating (Amps)
200
VoOage Rating (VAC)
120/240.10
thilityVellage Monitor (Fined)`
-Pick-up
-Dropout
80%
65%
)Mim to ubilly`
approx 13 sec
Exercises bl-rreeldy for 5 minM*
Standard
ULlfsted
Standard�"�----'i
Enclosure Type
NEMA/UL 3R
Circuit Breaker Protected
22,000
Lug Range
250 MGM -#6
`Function of Evolution CommOer
Exercise can be set to weekly or monody
16/20/22 kW
GENERACa
specifications
Generator
MGM G007035.1, G007G3B-1, G007038.1, 0007039.1 G007042-2, G007043.2
LezledpC Fiequ —__ 60 Hi ^T _-60 Hi— `--""—__601
Pow Factor 1.0 1.0 1.0
LBaOery Bequiremeld (notincluded) , � � 12 VoIts,Gro1p 26H 540 CCA Minimum or Group 35AGM 650 CCA Minlmllm
UnilWeight O6/kg) 4091186 448/203 4661211
ID'unensill�a (LHjiNmm _ 48— 25%29 /1218x638z732--^^�
a...Y.T._._.___ �_._._.____.__..�_. .__. - - ---
Sound ouW in dB(A) at 23 8 (7 m) with genemlm opemling a1 ZiW load" 67 67 67
Ig @m
3,6UU
Gas.
fle71u (ma/hr)
12 Load
218 (6.17)
_
Full Load.
309 (8.75)
'ropane
ftO/hr (gaUlu) 1W1
12 Load
74 (2.03) [7.701
204 (5.78)
301,(B.52)
87 (2.37) [8.991
228 (6.46)
327 (9.26)
92 (2.53) [9.571
•-SmudImstsaetakmImmVefiwdcditgmmW. Sound ImbtkenImmoffvsidesof the goner6amr/6eNyadWWmgon estuIhtiwpanurcemgatingdekmim s-S6aW.A Wcablelaraff"emugemyp wrWheduatlm
oldsd"pmraoMg9 lbomloadcpNTgismlaalelorihisrAq -MmonnNWgipsatlanadmesWledroaMrmnedMsch WsahrelMWMDooule
camem,am6iwdtenowme.aWhde.egimwwffdmtlitlogde Maamunpveertlenexe4W3.5peraNlaeaNl.OWlee1(361&mmms)abmmlerel:andagowdldaaeaeaWIpacatkI t6°C(10°F)Warel6"C(60'9.
16/20/22 kW
Installation System
• 10 (305 mm) flexible fuel line connector
• Direct -to -did composite mounting pad
• Integral sediment trap
Remote Monitoring
• Ability to view generator status
• Ability to view generator Exercise/Run and Total Hours
• Ability to view generator maintenance information
• Monthly report with previous month's activity.
• Ability to view generator battery Information
• Weather information
GENERAC'
features and benefits
Absorbs any generator vibration when connected to rigid pipe.
Complex lattice design prevents settling or sinking of the generator system.
Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
Monitor your generator via your smarlphone, tablet, or computer at any time via the Mabkle Link application for
complete peace of mind
Review the generators complete protection profile for exercise hours and total hours
Provides maintenance information for your specific model generator when scheduled maintenance is due
Detailed monthly reports provide historical generator information
Built in battery diagnostics displaying anent state of the battery
Provides detailed local ambient weather conditions for generator location
•
- GENERAC°
16/20/22 kW
features and benefits
Engine
•
Generac G-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
rings helps the engine ran cooler, reducing oil consumption resulting in longer engine life.
•
"Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
•
Electronic ignition/sparkadvance
These features combine to assure smooth, quick starting every time.
•
Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance andtongerengine
life. Now featuring up to a 2 year/200 hour oil change interval.
•
Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
•
High temperature shutdown
Prevents damage due to overheating.
Generator
•
Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature
generator.
•
Skewed stator
Produces a smooth output vravefonnfor compatibility with electronic equipment.
•
Displaced phase excitation
Maximizes motor starting capability.
•
Automatic voltage regulation
Regulates the output voltage to±l%prevents damaging voltage spikes.
•
UL2200listed
For your safety.
Transfer Switch (If applicable)
•
Fully automatic
Transfers your vital electrical loads to the energized source of power.
•
NEMA 3R
Can be installed inside or outside for maximum flexibility.
•
Remote mounting
Mounts near your existing distribution panel for simple, low-cost installation.
Evolution— Controls
•
Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, ata-glance status indication in any condition.
•
Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
•
Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
•
Utility voltage sensing
Constantly monitors utility voltage, setpoints 65%dropout, 80%pick-up, of standard voltage.
•
Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
•
Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of
five (5) seconds by a qualified dealer.
•
Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
•
Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
•
Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator
for 5 minutes every other week Also offers a selectable setting for weekly or monthly operation providing
flexibility and potential ly lower fuel costs to the owner.
•
Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
•
Main line circuit breaker
Protects generator from overload.
•
Electronic governor
Maintains constant 60 Hz frequency.
Unit
•
SAE weather protective enclosure
Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front foreasy access to all routine
maintenance items. Electrostatically applied tortured epoxy paint for added durability.
•
Enclosed critical grade mul0er
Quiet critical grade muffler is mounted inside the unit to prevent injuries.
•
Small, compact. attractive
Makes for an easy, eye appealing installation, as close as 1 B" (457 mm) away from a building.