Loading...
HomeMy WebLinkAboutProduct Approval; Standby GeneratorGENERAC® RECEIVED 16/20/22 kW AIN 15 2620 GUARDIAN SERIES Permitting Department Residential Standby Generators MINI_ st' `""e County. Air -Cooled Gas Engine INCLUDES: • True Power- Electrical Technology Standby Power Rating • Two Line LCD Multilingual Digital FILE COPY Models G007Model G00703-1 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-1 (Aluminum -Bisque) -16 kW 60 Hz Evolution- Controller (English/Spanish/ Models G007039-1, G007038-1 (Aluminum - Bisque) - 20 kW 60 Hz French/Portuguese) Models G007043-2, G007042-2 (Aluminum -Bisque) - 22 kW 60 Hz • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or ST.LUCIE COUNTY 200 Amp Service Rated Smart Switch. PLAN REVIEW See Page 5 for Details. • Electronic Governor Bl.DG: • Standard yY-Fl"' Remote Monitoring DAB • System Status & Maintenance Interval LED Indicator • Sound Attenuated Enclosure DATEZQ /L 0 • Flexible Fuel Line Connector PLUMB: • Direct -To -Dirt Composite Mounting Pad DATE: • Natural Gas or LP Gas Operation MECH: DATE: • 5 Year Limited Warranty • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18' (457 mm) to a structure.' *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. hnps://assels.swn.org//ibraryry/DirectoryO/LrstedProductsl Construcbonlndustry/W3 DoC_204_73204-01-0i Rev9.pdf FEATURES O INNOVATIVE ENGINE DESIGN& RIGOROUS TESTING area[ the headofGeneric's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most The G-Force series engines are purpose built and designed to handle the rigors of Wended run times in high temperatures and extreme operating conditions. O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5%Total Harmonic Distortion for utility graliry power. This allows confident operation of sensitive electronic equipment and microchip based appliances, such as variable speed HVAC systems. O TESTCNITERIA: J PHOTOTYPETESTED J NEMA MGI-22 EVALUATION J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY GENERAC' CLI US QUI&ME&T - r% Note: CUL certification only applies to unbundled units and wits padded with limited circuit switches. Units packaged with the Smart Switch are UL coddled in the USA only. SOUDSTATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Genemc models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque4natching the surge loads to the engine. Digital voltage regulation at ±1 %. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service [mow -how for the entire unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. O MOBILE LINK- REMOTE MONITORING: FREE with every Guardian Series Home s arafty,MOBILE LINKgenerator. Allows you to monitor theMONITORIN status:FILE Withyour horn Guardian anywhere in the "' GENERAC ,s•w world using a smadphone, tablet, or PC. Easily access inforodon such as the current PROMISE m `RM '� _ operating status and mainlemnce alerts. Connect your accourd to your authorized service dealer fortist, friendlyand proactive service. With Mobile Unk you are taken care of before the next power outage. 16/20/22 kW GENERAC available accessories Model # Product Description The Wi-R enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank Mon. 6007005-0 Wi-R LP Fuel Level Monitor Baring the LP tank's fuel level is an important step in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through afree application to notify when your LP tank is in need of a refill. G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Genersc offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PewerPact®). 6007101-0 Battery Pad Warmer The pad warmer rests underthebattery. Recommended for use ifto temperature regularly fags below 0 OF 08 °C). (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer 00 warmer slips directly over the oil filer. Recommended for use IT the temperature regularly falls below 0 'F (-18 "C). G007103-1 Breather Warmer The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Aelaliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Contact Kit you may not need. Nat compatible with 50 amp pre -wired switches. Fascia Base Wrap ICit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 - Bisque (Standardsleek, on 22 kW) contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. Ifthe generator enclosure is scratched or damaged, it is important to touch up the pant to protect from G005703-0 - Bisque Paint Kt future corrosion. The paintIdtIncludesthenecessarypaGdtoproperlymaintainortouchupagenerator enclosure. { G006485-0 Scheduled Maintenance Kit Generse's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to Increase its G006873-0 (50Amps) power management capabilities. it provides additional power managementflelo'bility not found in any other power management system dimensions & UPCs Dimasaims slwwn areaprradrrek. Refer installation manual for axed i inwnsimm DO NOT USE THESE DI AMIGNS FOR INSTALLATION PURPOSES. l SEDEV1EW r'nsee FAOMr V70v Model UPC G007035-1 696471074161 G007036-1 696471074154 G007037-1 696471074178 G007038-1 696471074185 G007039-1 696471074192 G007042-2 696471074208 G007043-2 696471074215 GENE RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com @201aGmre PowerSystmm.ticMdghbresPn&AAspnfficgausaresublecttodwwwftutrt0u.PadNo.1800800IO"(8101118) GENERAC 16/20/22 kW switch options Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMAAIL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with V standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effective install. Dimensions Height width Depth H1 1­12 Wl W2 in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175A wee Ranges conductor Lug Neueal Lug Ground Lug 1/0-#14 210-#14 2/0-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (OPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for last, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resis- tive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMAJUL 311 aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120240, to Open Transition Service Rated Height Width Depth H7 H2 wi W2 in 26.75 1 30.1 10.5 13.5 6.91 min 679.4 764.3 266.7 343.0 1744 Model G007036.1(16MN) 111o.of Poles 12 r Cooenl Rating (Amps) 100 v�olhage Isfing(VAC) 120/240.10 U01ityVollage Monitor (Fined)` -P kvp -0mpoot 80% 65% flenonto UOlity` appmx: 155e' c Exercisesbi-weeHy for 5 minutes' Standard ULUsted standard Talal CircuilsAvailable 24 Tandem Weaker Capabilities 8 tandems Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volls 10,000 *Function of Evolution Controller Exercise can be set to weekly or monthly Model 0007037-1 (16 WJ)/GU07039.1 (20 Nil G007043.2 (22 kYA No. of Pales 2 _ .a current Rating (Amps) 200 VoOage Rating (VAC) 120/240.10 thilityVellage Monitor (Fined)` -Pick-up -Dropout 80% 65% )Mim to ubilly` approx 13 sec Exercises bl-rreeldy for 5 minM* Standard ULlfsted Standard�"�----'i Enclosure Type NEMA/UL 3R Circuit Breaker Protected 22,000 Lug Range 250 MGM -#6 `Function of Evolution CommOer Exercise can be set to weekly or monody 16/20/22 kW GENERACa specifications Generator MGM G007035.1, G007G3B-1, G007038.1, 0007039.1 G007042-2, G007043.2 LezledpC Fiequ —__ 60 Hi ^T _-60 Hi— `--""—__601 Pow Factor 1.0 1.0 1.0 LBaOery Bequiremeld (notincluded) , � � 12 VoIts,Gro1p 26H 540 CCA Minimum or Group 35AGM 650 CCA Minlmllm UnilWeight O6/kg) 4091186 448/203 4661211 ID'unensill�a (LHjiNmm _ 48— 25%29 /1218x638z732--^^� a...Y.T._._.___ �_._._.____.__..�_. .__. - - --- Sound ouW in dB(A) at 23 8 (7 m) with genemlm opemling a1 ZiW load" 67 67 67 Ig @m 3,6UU Gas. fle71u (ma/hr) 12 Load 218 (6.17) _ Full Load. 309 (8.75) 'ropane ftO/hr (gaUlu) 1W1 12 Load 74 (2.03) [7.701 204 (5.78) 301,(B.52) 87 (2.37) [8.991 228 (6.46) 327 (9.26) 92 (2.53) [9.571 •-SmudImstsaetakmImmVefiwdcditgmmW. Sound ImbtkenImmoffvsidesof the goner6amr/6eNyadWWmgon estuIhtiwpanurcemgatingdekmim s-S6aW.A Wcablelaraff"emugemyp wrWheduatlm oldsd"pmraoMg9 lbomloadcpNTgismlaalelorihisrAq -MmonnNWgipsatlanadmesWledroaMrmnedMsch WsahrelMWMDooule camem,am6iwdtenowme.aWhde.egimwwffdmtlitlogde Maamunpveertlenexe4W3.5peraNlaeaNl.OWlee1(361&mmms)abmmlerel:andagowdldaaeaeaWIpacatkI t6°C(10°F)Warel6"C(60'9. 16/20/22 kW Installation System • 10 (305 mm) flexible fuel line connector • Direct -to -did composite mounting pad • Integral sediment trap Remote Monitoring • Ability to view generator status • Ability to view generator Exercise/Run and Total Hours • Ability to view generator maintenance information • Monthly report with previous month's activity. • Ability to view generator battery Information • Weather information GENERAC' features and benefits Absorbs any generator vibration when connected to rigid pipe. Complex lattice design prevents settling or sinking of the generator system. Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. Monitor your generator via your smarlphone, tablet, or computer at any time via the Mabkle Link application for complete peace of mind Review the generators complete protection profile for exercise hours and total hours Provides maintenance information for your specific model generator when scheduled maintenance is due Detailed monthly reports provide historical generator information Built in battery diagnostics displaying anent state of the battery Provides detailed local ambient weather conditions for generator location • - GENERAC° 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine ran cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/sparkadvance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance andtongerengine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output vravefonnfor compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to±l%prevents damaging voltage spikes. • UL2200listed For your safety. Transfer Switch (If applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution— Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, ata-glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65%dropout, 80%pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of five (5) seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week Also offers a selectable setting for weekly or monthly operation providing flexibility and potential ly lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front foreasy access to all routine maintenance items. Electrostatically applied tortured epoxy paint for added durability. • Enclosed critical grade mul0er Quiet critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact. attractive Makes for an easy, eye appealing installation, as close as 1 B" (457 mm) away from a building.