HomeMy WebLinkAboutConstruction PlansTOP HEADER RUBBER COUPLING t 4'x8', 10' OR 12' \ UPPER HOLD DOWN CLAMP SOLAR PANELS \ (SEE DETAIL A) (2 PER PANEL MIN.) \\\ NOT > 48" CTC, NOT < 16" CTC PANEL (TYP.) L BOTTOM HEADER L (SEE DETAIL B) PANELS SCALE= N.T.S. ITRAC-rf', ELMS: DATE": ELEC: DATE:. PLUMB: DATE: o5-14 MECH: PATE12) NO.14 x 2" IN ATTACHMENT HARDWARE SHEETMETAL7SCRE77PER ANCHOR LOCATION NOTE: CONTRACTOR TO USE OEM ATTACHMENT PARTS ONLY DISTANCE DECREASES FOR COLLECTOR COUPLING ARRAYS ENCROACHING IN PRESSURE HOSE CONNECTOR ZONE 2 AND/OR 3 COLLECTOR HEADER 2.00" I.D. (2) NO. 14 x 2" MIN SS HEX ASHER HEAD OR SHEET METAL SCREW PER MOUNT N "A" LOCATION INTO PLYWOOD COLLECTOR TUBES - SHEATHING OR ONE SCREW °.� WITH FULL EMBEDMENT IN RAFTER OR TRUSS - r— EXISTING ROOFING U) W; 1" DIA SS FENDER WASHER MINIMUM 1/2" O.S.B. OR 1/2"CDX PER SCREW PLYWDETAIL A SHEATOHING BYOD AOTHERS) THING (DESIGN OF SCALE= N.T.S. OEM PVC ANCHOR 1/2" PLASTIC COATED 316 BUTTON OR 16 GA. 7/8" X STAINLESS STELL STRAPPING 1/2" SS ANGLE (1 1/8" STRAP SPACIN .048" THICK, 670 LB BREAK NO.14 x 3" MIN SS HEX LONG) SLOTTED LEG FOR (SEE DETAIL C w STRENGTH WASHER HEAD OR SHEET STRAP INSTALLATION METAL SCREW PER (TYP.) 50" CTC MAX. ANCHOR LOCATION - ROOFING (EXISTING) NA MINIMUM 1/2" O.S.B. OR 11T CDX CONTINUOUS PLYWOOD SHEATHING (DESIGN OF SS STRAP TRUSSES OR RAFTER / \I SHEATHING BY OTHERS) ANCHORING SCREWS SHALL HAVE / DETAIL B EMBEDMENT IN TRUSS OR RAFTER 1/2" PLASTIC COATED 316 SCALE- N.T.S. MAX. 50" CTC MAX. ALONG STRAP STAINLESS STELL STRAPPING U) WASH14 O ER HEAD SHEET O.048" THICK, 670 LB BREAK x 3" MIN HEX (D STRENGTH WASH METAL SCREW PER ANGLE OR ] PVC BUTTON ANCHOR LOCATION ROOFING (EXISTING) TRUSSES OR RAFTER) n n\ DETAIL C 1. THE STRUCTURAL SYSTEMS DEPICTED HEREIN THESE DRAWINGS WERE DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017) AND ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES". 2. WIND SPEED IS 170 MPH ULTIMATE VELOCITY (132 MPH NOMINAL WIND SPEED) RISK CATEGORY 11 STRUCTURES. 3. WIND EXPOSURE CATEGORY = C & D (SEE NOTE 97) 4. ROOF ANGLE: 0" TO 45" 5. HEIGHT OF STRUCTURE <60 FT. 6. MEAN ROOF HEIGHT (MRH): UP TO 30' 7. SS STRAP SPACING FOR WIND EXPOSURE C IS 36" OC FOR ZONE 1, 24" OC FOR ZONE 2 , 16" OC FOR ZONE 3 FOR MPH UP TO 15'. SS STRAP SPACING FOR WIND EXPOSURE D IS 30" OC FOR ZONE 1, 20" OC FOR ZONE 2, 12" OC FOR ZONE 3 FOR MPH UP TO 15'. FOR EACH 5 FT. INCREASE IN MPH UP TO 30'- DECREASE STRAP SPACING BY V. 8. NO USE IN PRESSURE ZONE 3 IN HVHZ SCALE= N.T.S. MIN. <-.. , ; r •r ` FRONT �IOEB CHn-v1DE c ++Rf:AR rf�ia. MINIMUM 112" O.S.B. OR 1/2" CDX PLYWOOD SHEATHING (DESIGN OF SHEATHING BY OTHERS) ANCHORING SCREWS SHALL HAVE EMBEDMENT IN TRUSS OR RAFTER MAX. 50" CTC MAX. ALONG STRAP VAUD WITHOUT THE ORIGIM' !Jljl;i�11 42082 T E e 'Q3 2020 TODD N. Wil •FDEd B2 i77 /ONALE��� ''�/111111111�`\ rCINI r1 V s U z W m u D_ mad 2 LL a< 6 gm ~ QUN G7 rn=� Z W N a.. Om 0 0 IL O OLu K a a= OLL za O 9 z 9 I INSTALL A 3/8" S.S. MACHINE SCREW THROUGH TUBE INTO TOP OF S-5 CLAMP 1 1' SQ. X 1/8" ALUM. TUBE (6061-T6) "S-5" ALUM. CLAMP 2" �Ar of 1 1/2" (6061-T6) INSTALL A MIN. OF (2) 3/8" BULLET NOSE STAINLESS STEEL SET SCREWS TO STANDING SEAM STANDING SEAM METAL ROOF CONNECTION ASSEMBLY NOTE: FOR 71EDOWN ANCHORAGE OF SOLAR PANELS TO METAL ROOF, STRAPPING ASSEMBLIES DETAILED ON PAGE S-1 SHALL BE ANCHORED TO ASSEMBLY DETAILED ABOVE FOR CONNECTION TO STANDING SEAM METAL ROOFS. SCREWS SHALL BE #14 X 1" MIN. SS HEX WASHER HEAD OR SS SELF TAPPING SHEET MEAL SCREWS. ASSEMBLY ANCHORAGE INSTALL 1" SQ. X 1/8" SQUARE ALUM. TUBING TRACKS FOR SOLAR PANEL ANCHORAGE OVER "S-5" ALUMINUM CLAMP (6061-T6 ALLOY) AS MANUFACTURED BY "DYNAMIC FASTENER-) OVER STANDING SEAM OF ROOF PANELS. CLAMP SPACING TO MATCH STRAP SPACING (48" CTC FROM PANEL EDGE TO PANEL EDGE, AND AS SPECIFIED ON PAGE S-1 FOR MAX. SPACING o AoertEl TA DIM nr O"MCIt LEGEND D3 VACUUM RELIEF 2® THERMOMETER 3® SENSOR 04 BALL VALVE OS CHECK VALVE, . 06 3—WAY VALVE 7® WATER SENSOR OS FILTER 09 PUMP- SAUXILLARY HEATER NOTES: 1. CONTRACTOR IS ENCOURAGED TO INSTALL SYSTEM IN PRESSURE ZONE 1. IF PART OF SYSTEM MUST ENCROACH INTO PRESSURE ZONE 2 OR 3, ANCHORING SHALL BE ADJUSTED AS PER SPECIFICATIONS HEREIN. CONTRACTOR SHALL ATTACH COLLECTOR ARRAY WITH OEM HARDWARE AND STRAPPING. CONTRACTOR MUST BE CAREFUL TO "CENTER" ANCHORS SO SCREWS ARE INSTALLED INTO THE CENTER OF THE TRUSS TOP CHORD OR RAFTER BELOW. AN APPROVED ALTERNATIVE WOULD BE CONTRACTOR INSTALLED NOMINAL 2"X4" SOUTHERN PINE #2 BLOCKING BETWEEN TRUSSES OR RAFTERS AT SCREW LOCATION, CENTERED ON SCREW. BLOCKING SHALL BE CONNECTED TO TRUSS OR RAFTER WITH SIMPSON A34 OR A23 ON EACH FACE OF BLOCKING (2 CONNECTORS PER CONNECTION TO TRUSS OR RAFTER). 2. CONTRACTOR SHALL ADHERE TO REQUIREMENT OF FBC CHAPTER 15 (ROOFING) AND BEST PRACTICES OF NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE THE SOLAR INSTALLATION DOES NOT CAUSE ROOF LEAKS AT INITIAL INSTALLATION OR AS THE SYSTEM "AGES". 3. AS LONG AS CONNECTOR SPACING- AND NUMBERS ARE NOT REDCUED THE CONTRACTOR MAY USE A SUBSTRATE OR ALUMINUM MOUNTING FRAME, "SANDWICHED" BETWEEN THE COLLECTOR AND ROOF ON FLUSH MOUNT INSTALLATIONS ONLY. 4. OEM STRONGLY RECOMMENDS AGAINST CLAMPS ON THE BOTTOM HEADER. 5. SOLAR UNITS INSTALLED PER THIS PLAN SHALL NOT FORM PART OF THE BUILDING ENVELOPE (I.E. WINDOW, DOOR). SOLAR UNITS SHALL BE MOUNTED ABOVE ROOF SURFACE LIKE A A/C CONDENSER. THEREFORE NOT REQUIRING A PRESSURE RATING (I.E. WINDOWS, DOORS). SOLAR UNITS SHALL BE MOUNTED VERY CLOSE TO THE ROOF SURFACE, TO PROVIDE PRESSURE EQUALIZATION BETWEEN THE ROOF SURFACE AND THE BACK OF THE SOLAR UNITS. THIS RESULTS IN NO SIGNIFICANT CHANGES IN THE LOADS ON THE ROOF FRAMING FOR A PARALLEL MOUNT AND MODEST CHANGES IF TILT UP. HOWEVER THE INTERNAL AND EXTERNAL COMPONENTS OF WIND PRESSURE DECOUPLE, E.G. THE ROOF RESISTS THE°' INTERNAL WIND PRESSURES AND THE SOLAR UNITS RESIST THE EXTERNAL WIND PRESSURES. THE EXTERNAL WIND FORCES ARE THEN TRANSFERRED TO THE ROOF FRAMING THROUGH THE SOLAR ATTACHMENT h* HARDWARE. 0: 5. SOLAR POOL HEATING COLLECTORS ARE REQUIRED TO BE TESTED, CERTIFIED AND LISTED BY THE FLORIDA SOLAR ENERGY CENTER. CONTRACTOR SHALL PROVIDE DOCUMENTATION TO OWNER OF THEIR LISTING AND RATINGS. 1" DIA SS FENDER WASHER — PROVIDE 1/4" STAINLESS STEEL TAPCON SCREWS OF ADEQUATE LENGTH TO SECURE BRACKET TO CEMENT TILE DRILL HOLE THRU CONC. TILE ONLY (NOT INTO ROOF MEMBRANE) AND INSTALL TAPCON SO AS NOT TO BREAK TILES. I UT AUTOMATIC CONTROL NOTE: I- ® • OPTIONAL COMPONENTS APPLY ADHESIVE TO THE INTERFACE OF THE SOLAR WORLD MOUNTING D+ BRACKET AND PVC BUTTON ANCHORS BEING ATTACHED TO THE ISCHARGE FROM POOL NTAKE FROM POOL CONCRETE FLAT TILE OR BARREL TILE. CONTRACTOR SHALL ALSO APPLY ANCHORING EPDXY TO TAP CON SHAFT PRIOR TO INSTALLING TAP CON. GENERAL NOTE. ■ COMPONENTS ARE OPTIONAL b w - TAP CON TO BE INSTALLED PRIOR TO EPDXY SETTING. A 3"x1"x1/B" ,�+[,!j y ) ALUMINUM_(ALLOY:;6061-T6) ANGLE MAY BE USED TO MOUNT PANELS TO w ( .g TILE AS'A CONTRACTORS OPTION. APPROVED ANCHORING EPDXIES ARE TYP. PLUMBING SCHEMATIC CHEMLINK "MA", SUREEOND "S13-190" OR APPROVED EQUAL. scu -taus. '- INTERMEDIATE`BUTTON:ANCHORS TO BE PROVIDED FOR SS STRAPPING NOTES: -- AS DETAILED ON PACES-1. SPACING OF BUTTON ANCHORS ARE 48" OC 1. PLUMBING SHALL BE INSTALLED AS PER DETAIL AND ALL REQUIREMENTS OF THE; ALONG THE -SS STRAPING. SPACING OF STRAPING IS 2T' OC (EXP. C) & 24" 6th ED. FLORIDA PLUMBING CODE (2017). SPECIAL CARE SHALL BE TAKEN REGARDI�G OC (EXP_ D)-FOR PRESSURE ZONE 1 AND 16" OC (EXP. C) & 12" OC (EXP. D) PIPE SUPPORT, PER FPC TABLE 308.5. THE ABS VALUE OF 4 FT, SHALL BE TAKEN, FOR PRESSURE ZONE #2. PANELS ON TILE SHALL NOT BE INSTALLED IN AS THE MAXIMUM FOR HORIZONTAL AND 10 FT. FOR VERTICAL SOLAR PIPING. PER '- --PRESSURE ZONE 3. ADJUST STRAPPING SPACING FOR MEAN ROOF 6th ED. FLORIDA MECHANICAL CODE, CONTRACTOR SHALL INSTALL MANUAL DRAIN --:HEIGHT OF STRUCTURE FROM 15 FT. TO 30 FT. AS SPECIFIED ON PG. S-1. DOWN VALVES AND INSTRUCT OWNER IN DRAINING AND RE -STARTING THIS SOLAR BUTTON TOOWNERANCHORS TO BE INSTALLED IN CENTER AND/OR CROWN OF TILE. On IF SOLAR POOLTSTHE OWNER'SSOLERESON NG SYSTEM. VHEATER FREEZES, INER SHALL BE ORED THAT ZOSBIIIY TECTION S.T. STRAP BRACKET FREEZE DAMAGE RESULTS FROM AN ERROR IN OPERATION. COLLECTORS SHOULD ALWAYS BE DRAINED BY OWNER OR OWNER'S REPRESENTATIVE IN ADVANCE OF NEAR FREEZING WEATHER. Flat Roof Gable Roof (A 5 7") Hip Roof (7"< B 5 27°) Gable Roof W< 45 451I Interior Zones End Zones - Comer Zones Pwb-] IM,N.imo1 11rtd.laniMdll. iue5 MN.}asf PRESSURE ZONE NOTES NTS PRESSURE ZONE NOTES 10 PERCENT OF THE LEAST HORIZONTAL DIMENSION OR .4h, WHICHEVER IS LESS, BUT NOT LESS THAN EITHER 4% OF LEAST HORIZONTAL DIMENSION OR 3 FT. MEAN ROOF HEIGHT, IN FEET, EXCEPT THAT EAVE HEIGHT SHALL BE USED FOR ROOF ANGLES < THAN 10 DEGREES. ANGLE OF PLANE OF ROOF FROM HORIZONTAL, IN DEGREES. TILE ROOF SCALE= N.T.S. COLLECTOR HEADER 2.00" I.D. 5/32" WALL THICKNESS COLLECTOR TUBES 0.220 I.D. WITH 0.030 WALL �1� /— CONC. BARRELIFLAT TILE \ MINIMUM 1/2" O.S.B. OR PLYWOOD SHEATHING TODD N. N w 1 W h U Z LU 0_ maLU n op2 ,§0 03 QUR 00 Z Wwa rn O H G J LY W Lu f0 Z IL d 0� 00 IL 0 S U 2 Cc