HomeMy WebLinkAboutSeal-a-Ridge product approval.pdfMIAMF� MIAMI-DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Stmet, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) w .miamidade.eov/economy GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Seal -A -Ridge® Ridge Cap Shingles and GAF Timberte3O Premium Ridge Cap Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 17-0824.04and consists of pages 1 through 9. The submitted documentation was reviewed by Freddy Semino a NOA No.: 18-1129.05 MIAMIDADE COUNTY Expiration Date: 10/17/22 Approval Date: 02/21/19 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Cateeorv: Asphalt Shingles Materials 3-Tab Perforated Deck Type: Wood SCOPE This approves GAF Seal -A -Ridge® Ridge Cap Shingle and GAF Timbertex® Premium Ridge Cap Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Seal -A -Ridge® Ridge Cap 12" x 36" TAS 110 Pre fabricated hip and ridge asphalt shingle Shingle with two perforations at 12" o.c. along the 36" Manufacturing Location #1 & 3 length of shingle. GAF Timbertee Premium 12" x 36" TAS 110 Ridge Cap Shingle Manufacturing Location #2 PRODUCTS MANUFACTURED BY OTHERS Product Product Size Description Polyurethane Sealant Adhesive Various MANUFACTURING LOCATION 1. Mobile, AL. 2. Mt. Vernon, IN. 3. Savannah, GA. Prefabricated hip and ridge fiberglass reinforced asphalt shingle with perforations at 12" o.c. along the 36" length of the shingle. Manufacturer Miami Dade Approved ASTM C 920 Polyurethane Sealant NOA No.: 18-1129.05 Expiration Date: 10/17/22 Approval Date: 02/21/19 Page 2 of 9 EVIDENCE SUBMITTED Test Aeencv Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. ASTM D3462 11CA45079 03/21/12 ASTM D3462 12CA30878 02/01/13 TAS 107 IICA45079 03/21/12 TAS 107 12CA38083 02/26/13 Fire Classification TFWZ.R21 09/16/16 ASTM D3161 4788698165 11/09/18 ASTM D3161 4788669132 12/13/18 PRI Construction Materials TAS 100 GAF-380-02-01 11/06/12 Technologies LLC TAS 100 GAF-381-02-01 11/15/12 TAS 100 GAF-895-02-01 11/20/18 TAS 100 GAF-896-02-01 11/20/18 ASTM D3462 GAF-897-02-01 11/08/18 ASTM D3462 GAF-899-02-01 11/16/18 ASTM D3462 GAF-898-02-01 11/08/18 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. GAF Seal -A -Ridge® and GAF Timbertex® Premium Ridge Cap Shingles shall be limited for use as hip and ridge cap shingles only. 3. Shall not be installed on roof mean heights in excess of 33 ft. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. INSTALLATION 1. GAF Seal -A -Ridge® Ridge Cap Shingle and GAF Timbertex® Premium Ridge Cap Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Nailing for GAF Seal -A -Ridge® Ridge Cap Shingle shall be in compliance with Detail 'A' attached. Exposure and course layout for GAF Seal -A -Ridge® Ridge Cap Shingle Ridge Cap Shingles shall be in compliance with Detail 'A'. 5. Nailing for GAF Timbertex® Premium Ridge Cap Shingles shall be in compliance with Detail `B' attached. Exposure and course layout for GAF Timbertex® Ridge Cap Shingles shall be in compliance with Detail `B'. 6. A Miami Dade Approved ASTM C 920 Polyurethane Roof Sealant must be used in the application of GAF Seal -A -Ridge® Ridge Cap Shingles as specified in Detail A. 7. A Miami Dade Approved ASTM C920 Polyurethane Sealant Roof must be used in the application of GAF Timbertex® Premium Ridge Cap Shingles as specified in Detail B. NOA No.: 18-1129.05 Expiration Date: 10/17/22 Approval Date: 02/21/19 Page 3 of 9 LABELING Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below: APPROVED BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 18-1129.05 Expiration Date: 10/17/22 Approval Date: 02/21/19 Page 4 of 9 DETAIL A GAF Seal -A -Ridge® Ridge Cap Shingles Application Instructions: (1) Step One — Separate each piece of GAF Seal -A -Ridge® Ridge Cap Shingles into three individual ridge cap shingle pieces at perforations (see Figure 1). Figure 1 'h(12 mm) � 2' Y � � 11� (306 mmy I I 8 1 6 5/8' Exposure 1 � � (169 mm approx.) 1 h 6 12' (305 n Perbrated 36' 14 (914 mm) (2) Step Two — Begin laying full ridge cap shingle with a 6-2/3" exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind (see Figure 2). Figure 2 astener NOA No.: 19-1129.05 Expiration Date: 10/17/22 Approval Date: 02/21/19 Page 5 of 9 (3) Step Three — Apply ridge cap using 2 nails per piece 7" to 7-5/8" back from the exposed end and 1" to 2" up from the edge (see Figure 2 for location of nails). Use only corrosion resistant zinc coated steel or aluminum, 10-12 gauge, barbed, deformed or rings shank roofing nails with heads 3/8" (9.5mm) to 7/16" (12mm) in diameter. Nails should be long enough to penetrate at least 3/4" (19mm) into wood decks or just through plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised nails will interfere with the wind resistance of the shingles. Special Application Section: For Cold Weather Application • In cold weather, warm GAF Seal -A -Ridge® Ridge Cap Shingles before bending. • When self-sealing is delayed due to cold weather, apply quarter -sized dabs of an approved asphalt plastic cement (must conform to ASTM D4586 Type I or Type 11) between ridge cap pieces and press firmly to insure good contact between pieces. For Aigh-Wind Zones • In high wind areas or for maximum wind resistance, apply a Ye" wide bead of a Miami Dade Approved ASTM C 920 Polyurethane Sealant to each ridge cap shingle parallel to the ridge V — 1" from the shingle edge. (see Figure 3). Figure 3 For maximum wind speed coverage under ltd. warranty, apply additional sealant as shown. See Special Application Section for specific details. Para el alcance msximo de velocidad de viento bajo IimBado garantia. splice sellador adiclonal como rnosbado. Vea Secci6n Especial de Apkcacidn para dertalles especificos, Pour Is couverture mapmum de vitesse de vent sous limits. Is garantie, appliquer de 1'enduit d'stancheits supplementaire comme indiqus. Volr Is section specials d'application pour les details spscifiques. NOA No.: 18-1129.05 MIAMMADE COUNT Expiration Date: 10/17/22 Approval Date: 02/21/19 Page 6 of 9 DETAIL B GAF Timbertex® Premium Ridge Cap Shingles Application Instructions: (1) Step One — Separate each piece of GAF Timbertex® Premium Ridge Cap Shingles into three individual ridge cap shingle pieces at perforations (see Figure 1). Figure 1 (305mm) I (305mm�1~mm~I Self -Seal Adhesive 4 002nL I I on Back Adhesivo Auto- Sellante an Is 8-f203mm) I Perforations I Parte Posterior I I Perforaciones I I I f Adhesif Auto - Perforations Soellam A _ _ L'Endos t t Self -Seal Adhesive on Back Bottom Backer Adhesivo Auto-Sellante on la Parts Posterior Apoyo Inferior Adhesif Auto-Scellant A LEndos Appui Infedwr (2) Step Two — Prepare the starter course. For this step, take a 12" x 12" (305mm x 305mm) ridge cap piece and cut along the line between exposure and headlap (see Figure 2). Exposure Starter r' — Self -Seal Adhesive on Back Figure 2 • g 3 mm— • Nall 9" (229 mm) from bottom & 1 "(25 mm) from edge 3cker NOA No.:18-1129.05 Expiration Date:10/17/22 Approval Date: 02/21/19 Page 7 of 9 (3) Step Three —Place the 4" x 12" (102mm x 305mm) starter cap across the ridge starting at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. Note: For cold weather application or for high wind zones see special application section below. (4) Step Four — Begin laying full ridge cap shingle pieces 12" x 12" (305mm x 305mm) as shown (see Figure 2). Apply with an 8" exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. (5) Step Five — Apply ridge cap using 2 nails per piece 9" back from the exposed end and 1" up from the edge (see Figure 3 for location of nails). Use only zinc coated steel or aluminum, 10-12 gauge, barbed, deformed or smooth shank roofing nails with heads 3/8" (9.5mm) to 7/16" (12mm) in diameter. Nails should be long enough to penetrate at least 3/4" (19mm) into wood decks or just through plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised nails will interfere with the wind resistance of the shingles. Figure 3 12" (305mm) Top Laminated Piece 4• PiemSuperior LaminadL 102mm Piece Lamrroe SupErieure I�1'(25nri 1-(25mm)yl � + � iI• 11• Neil i Fold Line Nail Claw Linea de Pliegue Claw Clou Ligne N Pliage Clou 8' 203mm NOA No.: 18-1129.05 Expiration Date:10/17/22 Approval Date: 02/21/19 Page 8 of 9 Special Application Section: For Cold Weather Application • In cold weather, warm GAF Timbertex® Premium Ridge Cap Shingles before bending. • When self-sealing is delayed due to cold weather, apply quarter -sized dabs of an approved asphalt plastic cement (must conform to ASTM D4586 Type I or Type In between ridge cap pieces and press firmly to insure good contact between pieces. For High -Wind Zones • In high wind areas or for maximum wind resistance, apply a ''/I' wide bead of a Miami Dade Approved ASTM C 920 Polyurethane Sealant to each ridge cap shingle'/1'-I" from the shingle edge, parallel to the ridge (see Figure 4). Note. Excessive application of tab adhesive can cause blistering of ridge cap shingle. Figure 4 12" (305mm) —r! m air-r ,+� yr._,. Top Lemineeed Piece � y PiemSuperior Laminadr. Piece Laminee Superieure I 1l>?rnI�1'(25mm) j 1-(25mm1'~I 8' 203mm Nail l Fold Line Nml Claw l Linea de Pliegue Claw Clou Linne De Pliage Clou END OF THIS ACCEPTANCE NOA No.:18-1129.05 Expiration Date: 10/17/22 Approval Date: 02/21/19 Page 9 of 9 r1 rLCP:C4 CAMPtMM D< 1�+— Business 8 Professional Regulation dllk-s•4 acts Rome lag In User Reglstratlon d�Pr ®Product Approval USER: Public User P Apomval Menu > Pr ua or Applu;atlon Search > Agpllraf on LSt > APPIMJtdbn 101M111 Rot Topla Submit Surcharge Stats a Fags Publications COmact 05 8CI5 Ste Map UL1 SearN FL * FL16048-R6 Application Type Revision Code Version 2017 Application Status Approved Comments QA entity has been called Into question. 05/11/2020 Archived Product Manufacturer Tri-Built Materials Group, LLC Address/Phone/Email PO Box 70 Rutherford, NJ 07070 (800) 516-1485 davld.mizotrlbulRmg.com Authorized Signature David Ruiz david.miz@tribuiltmg.com Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North East Rutherford, NJ 07073 (201)842-2449 david.m izotribullbnaterialsgmup.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nleminen Evaluation Report Florida Ucense PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/18/2020 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL16048 R6 COI 2017 01 COI Nieminen.pdf Standard ASTM D1970 ASTM G155 FM 4474 FRSA/TRI April 2012 (04-12) UL 1897 YAK 2015 2005 2011 2012 2012 https:/Aw.floridabuilding.org/pr/pr_app_dtl.aspx?pammwGEVXGwtDgtFPmdYiNDWrwipmtAnR8jv9FiYHTk4FLCxcgVtRhfvMw%3d%3d 1/2 6/23/2020 Florida Building Code Online Sections from the Code Product Approval Method Method I Option D Date Submitted 09/25/2017 Date Validated 10/01/2017 Date Pending FBC Approval 10/03/2017 Date Approved 12/12/2017 Summery of Products FL • Model, Number or Name Description 16048.1 TRI-BUILT Roof Underlayments Self -adhering, modified bitumen roof underlayments Limits of Uae Installation Instructions Approved for use in HVH3:: No FL16048 R6 II 2017 09 FINAL ER TRI- Approved for use outside HVH2: Yes BUILT UNDERLAYMENTS FL36048-R6.odf Impact Resistant: N/A Verified By: Robert Nlemmen PE-59166 Design Pressure: +N/A/-150 Created by Independent Third Party: Yes Other: 1.) The design pressure noted herein pertains to use of Evaluation Reports foam -on tile systems overtop the self -adhering undedayment FL16048 u6 AE 7017 na FINAL, ER TRI- for one particular application. See ER Section 5.6.4 for details. BUILT UNDERLAYMENTS FL16048-Rfi 11df 2.) Refer to ER Section 5 for other Unnits of Use. Created by Independent Third Party: Yes Back o Conrad Us :: 2501 Blair Stone Road, Tallahassee FL 323" Phone: 950-07-I824 The State of Flonda is an AAjR0 employer. copyright 2007-2013 State of Florida.:: Frowsy statement :: Accesslb'rty Statement :: Refund Statement Under Florlda law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. It you have any questions, please Cnrad 650.4117. 1395. 'Pursuara to section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under chapter 4SS, F.S. must provide tie Department with an small address if May have one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, phease provide Me Department win an small address which can be made available M Me public. To determine if you are a licensee under chapter 455, ES., please dick banL. Product Approval Aocapra: ® ® ® EE Credit Card Safe httpsJ/www.floddabuilding.orglpr/pr_app_dU.aspx7pamm=wGEVXOwIDgtFPmdYiNDWnvipmtAnR8jv9FiYHTk4FLCxcgVtRhfvMw%3d%3d 2/2