HomeMy WebLinkAboutSeal-a-Ridge product approval.pdfMIAMF� MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Stmet, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) w .miamidade.eov/economy
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Seal -A -Ridge® Ridge Cap Shingles and GAF Timberte3O Premium Ridge Cap Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 17-0824.04and consists of pages 1 through 9.
The submitted documentation was reviewed by Freddy Semino a
NOA No.: 18-1129.05
MIAMIDADE COUNTY Expiration Date: 10/17/22
Approval Date: 02/21/19
Page 1 of 9
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub-Cateeorv:
Asphalt Shingles
Materials
3-Tab Perforated
Deck Type:
Wood
SCOPE
This approves GAF Seal -A -Ridge® Ridge Cap Shingle and GAF Timbertex® Premium Ridge Cap Shingles as
manufactured by GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Seal -A -Ridge® Ridge Cap 12" x 36" TAS 110 Pre fabricated hip and ridge asphalt shingle
Shingle with two perforations at 12" o.c. along the 36"
Manufacturing Location #1 & 3 length of shingle.
GAF Timbertee Premium 12" x 36" TAS 110
Ridge Cap Shingle
Manufacturing Location #2
PRODUCTS MANUFACTURED BY OTHERS
Product Product Size
Description
Polyurethane Sealant Adhesive Various
MANUFACTURING LOCATION
1. Mobile, AL.
2. Mt. Vernon, IN.
3. Savannah, GA.
Prefabricated hip and ridge fiberglass
reinforced asphalt shingle with perforations at
12" o.c. along the 36" length of the shingle.
Manufacturer
Miami Dade Approved ASTM C 920
Polyurethane Sealant
NOA No.: 18-1129.05
Expiration Date: 10/17/22
Approval Date: 02/21/19
Page 2 of 9
EVIDENCE SUBMITTED
Test Aeencv
Test Identifier
Test Name/Report
Date
Underwriters Laboratories, Inc.
ASTM D3462
11CA45079
03/21/12
ASTM D3462
12CA30878
02/01/13
TAS 107
IICA45079
03/21/12
TAS 107
12CA38083
02/26/13
Fire Classification
TFWZ.R21
09/16/16
ASTM D3161
4788698165
11/09/18
ASTM D3161
4788669132
12/13/18
PRI Construction Materials
TAS 100
GAF-380-02-01
11/06/12
Technologies LLC
TAS 100
GAF-381-02-01
11/15/12
TAS 100
GAF-895-02-01
11/20/18
TAS 100
GAF-896-02-01
11/20/18
ASTM D3462
GAF-897-02-01
11/08/18
ASTM D3462
GAF-899-02-01
11/16/18
ASTM D3462
GAF-898-02-01
11/08/18
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. GAF Seal -A -Ridge® and GAF Timbertex® Premium Ridge Cap Shingles shall be limited for use as hip and
ridge cap shingles only.
3. Shall not be installed on roof mean heights in excess of 33 ft.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. GAF Seal -A -Ridge® Ridge Cap Shingle and GAF Timbertex® Premium Ridge Cap Shingles shall be installed
in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Nailing for GAF Seal -A -Ridge® Ridge Cap Shingle shall be in compliance with Detail 'A' attached. Exposure
and course layout for GAF Seal -A -Ridge® Ridge Cap Shingle Ridge Cap Shingles shall be in compliance with
Detail 'A'.
5. Nailing for GAF Timbertex® Premium Ridge Cap Shingles shall be in compliance with Detail `B' attached.
Exposure and course layout for GAF Timbertex® Ridge Cap Shingles shall be in compliance with Detail `B'.
6. A Miami Dade Approved ASTM C 920 Polyurethane Roof Sealant must be used in the application of GAF
Seal -A -Ridge® Ridge Cap Shingles as specified in Detail A.
7. A Miami Dade Approved ASTM C920 Polyurethane Sealant Roof must be used in the application of GAF
Timbertex® Premium Ridge Cap Shingles as specified in Detail B.
NOA No.: 18-1129.05
Expiration Date: 10/17/22
Approval Date: 02/21/19
Page 3 of 9
LABELING
Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of manufacturing
facility, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade
County Product Control Seal as seen below:
APPROVED
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 18-1129.05
Expiration Date: 10/17/22
Approval Date: 02/21/19
Page 4 of 9
DETAIL A
GAF Seal -A -Ridge® Ridge Cap Shingles Application Instructions:
(1) Step One — Separate each piece of GAF Seal -A -Ridge® Ridge Cap Shingles into three individual
ridge cap shingle pieces at perforations (see Figure 1).
Figure 1
'h(12 mm)
� 2' Y � � 11�
(306 mmy I I
8 1 6 5/8' Exposure
1 � �
(169 mm approx.)
1 h 6
12'
(305 n
Perbrated
36'
14 (914 mm)
(2) Step Two — Begin laying full ridge cap shingle with a 6-2/3" exposure beginning at the bottom of the
hip or from the end of the ridge opposite the direction of the prevailing wind (see Figure 2).
Figure 2
astener
NOA No.: 19-1129.05
Expiration Date: 10/17/22
Approval Date: 02/21/19
Page 5 of 9
(3) Step Three — Apply ridge cap using 2 nails per piece 7" to 7-5/8" back from the exposed end and 1"
to 2" up from the edge (see Figure 2 for location of nails). Use only corrosion resistant zinc coated steel
or aluminum, 10-12 gauge, barbed, deformed or rings shank roofing nails with heads 3/8" (9.5mm) to
7/16" (12mm) in diameter. Nails should be long enough to penetrate at least 3/4" (19mm) into wood
decks or just through plywood decks. Nails must be driven flush with the surface of the shingle. Over
driving will damage the shingle. Raised nails will interfere with the wind resistance of the shingles.
Special Application Section:
For Cold Weather Application
• In cold weather, warm GAF Seal -A -Ridge® Ridge Cap Shingles before bending.
• When self-sealing is delayed due to cold weather, apply quarter -sized dabs of an approved asphalt
plastic cement (must conform to ASTM D4586 Type I or Type 11) between ridge cap pieces and
press firmly to insure good contact between pieces.
For Aigh-Wind Zones
• In high wind areas or for maximum wind resistance, apply a Ye" wide bead of a Miami Dade
Approved ASTM C 920 Polyurethane Sealant to each ridge cap shingle parallel to the ridge V —
1" from the shingle edge. (see Figure 3).
Figure 3
For maximum wind speed coverage under ltd. warranty, apply
additional sealant as shown. See Special Application Section
for specific details.
Para el alcance msximo de velocidad de viento bajo IimBado
garantia. splice sellador adiclonal como rnosbado. Vea Secci6n
Especial de Apkcacidn para dertalles especificos,
Pour Is couverture mapmum de vitesse de vent sous limits. Is garantie,
appliquer de 1'enduit d'stancheits supplementaire comme indiqus.
Volr Is section specials d'application pour les details spscifiques.
NOA No.: 18-1129.05
MIAMMADE COUNT Expiration Date: 10/17/22
Approval Date: 02/21/19
Page 6 of 9
DETAIL B
GAF Timbertex® Premium Ridge Cap Shingles Application Instructions:
(1) Step One — Separate each piece of GAF Timbertex® Premium Ridge Cap Shingles into three
individual ridge cap shingle pieces at perforations (see Figure 1).
Figure 1
(305mm) I (305mm�1~mm~I
Self -Seal
Adhesive
4 002nL
I I
on Back
Adhesivo Auto-
Sellante an Is
8-f203mm)
I Perforations I
Parte Posterior
I
I Perforaciones I
I I
f Adhesif Auto -
Perforations
Soellam A
_
_
L'Endos
t t
Self -Seal Adhesive on Back
Bottom Backer
Adhesivo Auto-Sellante on la Parts Posterior
Apoyo Inferior
Adhesif Auto-Scellant A LEndos
Appui Infedwr
(2) Step Two — Prepare the starter course. For this step, take a 12" x 12" (305mm x 305mm) ridge cap
piece and cut along the line between exposure and headlap (see Figure 2).
Exposure
Starter r' —
Self -Seal Adhesive on Back
Figure 2
•
g
3 mm— • Nall 9" (229 mm) from bottom
& 1 "(25 mm) from edge
3cker
NOA No.:18-1129.05
Expiration Date:10/17/22
Approval Date: 02/21/19
Page 7 of 9
(3) Step Three —Place the 4" x 12" (102mm x 305mm) starter cap across the ridge starting at the bottom
of the hip or from the end of the ridge opposite the direction of the prevailing wind.
Note: For cold weather application or for high wind zones see special application section below.
(4) Step Four — Begin laying full ridge cap shingle pieces 12" x 12" (305mm x 305mm) as shown (see
Figure 2). Apply with an 8" exposure beginning at the bottom of the hip or from the end of the ridge
opposite the direction of the prevailing wind.
(5) Step Five — Apply ridge cap using 2 nails per piece 9" back from the exposed end and 1" up from the
edge (see Figure 3 for location of nails). Use only zinc coated steel or aluminum, 10-12 gauge, barbed,
deformed or smooth shank roofing nails with heads 3/8" (9.5mm) to 7/16" (12mm) in diameter. Nails
should be long enough to penetrate at least 3/4" (19mm) into wood decks or just through plywood decks.
Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised
nails will interfere with the wind resistance of the shingles.
Figure 3
12" (305mm)
Top Laminated Piece
4•
PiemSuperior LaminadL
102mm
Piece Lamrroe SupErieure
I�1'(25nri 1-(25mm)yl
�
+
�
iI•
11•
Neil
i Fold Line
Nail
Claw
Linea de Pliegue
Claw
Clou
Ligne N Pliage
Clou
8'
203mm
NOA No.: 18-1129.05
Expiration Date:10/17/22
Approval Date: 02/21/19
Page 8 of 9
Special Application Section:
For Cold Weather Application
• In cold weather, warm GAF Timbertex® Premium Ridge Cap Shingles before bending.
• When self-sealing is delayed due to cold weather, apply quarter -sized dabs of an approved asphalt
plastic cement (must conform to ASTM D4586 Type I or Type In between ridge cap pieces and
press firmly to insure good contact between pieces.
For High -Wind Zones
• In high wind areas or for maximum wind resistance, apply a ''/I' wide bead of a Miami Dade
Approved ASTM C 920 Polyurethane Sealant to each ridge cap shingle'/1'-I" from the shingle
edge, parallel to the ridge (see Figure 4).
Note. Excessive application of tab adhesive can cause blistering of ridge cap shingle.
Figure 4
12" (305mm) —r!
m air-r
,+� yr._,. Top Lemineeed Piece �
y PiemSuperior Laminadr.
Piece Laminee Superieure I
1l>?rnI�1'(25mm) j 1-(25mm1'~I
8'
203mm
Nail l Fold Line Nml
Claw l Linea de Pliegue Claw
Clou Linne De Pliage Clou
END OF THIS ACCEPTANCE
NOA No.:18-1129.05
Expiration Date: 10/17/22
Approval Date: 02/21/19
Page 9 of 9
r1
rLCP:C4 CAMPtMM D< 1�+—
Business 8 Professional Regulation dllk-s•4
acts Rome lag In User Reglstratlon
d�Pr
®Product Approval
USER: Public User
P Apomval Menu > Pr ua or Applu;atlon Search > Agpllraf on LSt > APPIMJtdbn 101M111
Rot Topla Submit Surcharge Stats a Fags Publications COmact 05 8CI5 Ste Map UL1 SearN
FL *
FL16048-R6
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
QA entity has been called Into question. 05/11/2020
Archived
Product Manufacturer
Tri-Built Materials Group, LLC
Address/Phone/Email
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
davld.mizotrlbulRmg.com
Authorized Signature David Ruiz
david.miz@tribuiltmg.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, NJ 07073
(201)842-2449
david.m izotribullbnaterialsgmup.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nleminen
Evaluation Report
Florida Ucense
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
07/18/2020
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL16048 R6 COI 2017 01 COI Nieminen.pdf
Standard
ASTM D1970
ASTM G155
FM 4474
FRSA/TRI April 2012 (04-12)
UL 1897
YAK
2015
2005
2011
2012
2012
https:/Aw.floridabuilding.org/pr/pr_app_dtl.aspx?pammwGEVXGwtDgtFPmdYiNDWrwipmtAnR8jv9FiYHTk4FLCxcgVtRhfvMw%3d%3d 1/2
6/23/2020
Florida Building Code Online
Sections from the Code
Product Approval Method Method I Option D
Date Submitted
09/25/2017
Date Validated
10/01/2017
Date Pending FBC Approval
10/03/2017
Date Approved
12/12/2017
Summery of Products
FL •
Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Uae
Installation Instructions
Approved for use in HVH3:: No
FL16048 R6 II 2017 09 FINAL ER TRI-
Approved for use outside HVH2: Yes
BUILT UNDERLAYMENTS FL36048-R6.odf
Impact Resistant: N/A
Verified By: Robert Nlemmen PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use of
Evaluation Reports
foam -on tile systems overtop the self -adhering undedayment
FL16048 u6 AE 7017 na FINAL, ER TRI-
for one particular application. See ER Section 5.6.4 for details.
BUILT UNDERLAYMENTS FL16048-Rfi 11df
2.) Refer to ER Section 5 for other Unnits of Use.
Created by Independent Third Party: Yes
Back o
Conrad Us :: 2501 Blair Stone Road, Tallahassee FL 323" Phone: 950-07-I824
The State of Flonda is an AAjR0 employer. copyright 2007-2013 State of Florida.:: Frowsy statement :: Accesslb'rty Statement :: Refund Statement
Under Florlda law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. It you have any questions, please Cnrad 650.4117. 1395. 'Pursuara to section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under chapter 4SS, F.S. must provide tie Department with an small address if May have one. The smalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, phease
provide Me Department win an small address which can be made available M Me public. To determine if you are a licensee under chapter 455, ES., please dick banL.
Product Approval Aocapra: