HomeMy WebLinkAboutRigid Vent product approval.pdfMIAMI-DADE COUNTY NIAMM PRODUCT CONTROL SECTION min 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-25" NOTICE OF ACCEPTANCE (NOA) wwa.miamidade.eov/economy GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Cobra" Rigid Vent 3TM Exhaust Vent for Roof Ridge (with 3" ring shank nails), Cobras Rigid Vent 3TM 9" Exhaust Vent for Roof Ridge (with 3" ring shank nails), Cobra" Snow Country AdvancedTM Exhaust Vent for Roof Ridge (with filter and 3"ring shank nails), Cobras Snow Country AdvancedTM 9" Exhaust Vent for Roof Ridge (with filter and 3" ring shank nails), Cobras Snow CountryTM Exhaust Vent for Roof Ridge (with filter, no nails), and Cobras Snow CountryTM AH Exhaust Vent for Roof Ridge (with filter, no nails) LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.16-0217.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Hamlev Pacheco, P.E. 1 NOA No.:194521.04 Expiration Date: 10/18/21 Approval Date: 09/12/19 Page 1 of 7 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Ventilation Material: Plastic TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specifications Descriotion Cobra® Rigid Vent 3Tm Exhaust Vent for Roof Ridge (with 3" ring shank nails) Plastic low profile shingle Cobra® Snow Country AdvancedTm Exhaust Vent Height-- 7/8" over attic ridge vent for for Roof Ridge (with filter and 3" ring shank nails) Width= 13-13/16" TAS 110 installation in shingle roof Cobra® Snow CountryT"' Exhaust Vent for Roof Len h= 48" � Ridge (with filter, no nails) systems. With or without Cobra® Snow CountryTM AH Exhaust Vent for filter. Roof Ridge (with filter, no nails) (3" ring shank corrosion Cobra® Rigid Vent 3TM 9" Exhaust Vent for Roof Ridge (with 3" ring shank nails) Height-- 7/8" TAS 110 resistant nails supplied if Cobra® Snow Country AdvancedTm 9" Exhaust Width= 11-5/16" indicated in product name) Vent for Roof Ridge (with filter and 3" ring shank Length= 48" nails) MANUFACTURING LOCATION: 1. Cumming, GA 2. New Columbia, PA EVIDENCE SUBMITTED: Test Aaencv Test Name/Report Test Identifier Date Architectural Testing, Inc. ASTM D 1929 ASTM D635 ASTM D 2843 D2702.01-106-18-R1 01/19/15 ASTM D635 PRI Asphalt Technologies, Inc. ASTM G 638 HBP-002-02-01 06/06/01 ASTM G 85/ PA 114 HBP-003-02-01 08/03/01 TAS 100 HBP-01-02-01 11/02/00 Architectural Testing, Inc. TAS 100 60172.01-122-18 10/07/05 ASTM D 1929/ D 635 59665.02-106-31 09/16/05 PRI Construction Materials Technologies, Inc. TAS 100 GAF-310-02-01 01/29/16 TAS 100 376T0008 07/24/19 Intertek ASTM D638 / E168 H5341.01-106-18 Rl 01/22/18 NOA No.: 18-0521.04 Expiration Date: 10/18/21 Approval Date: 09/12/19 Page 2 of 7 APPROVED APPLICATIONS: Slot: Determine whether the rafters arc truss or ridgepole construction. Chalk a cut line of each side of ridge. Cut a 1 %" (truss) or 3 '/:'(ridge pole) slot along the apex of the roof by cutting 7/8" on each side of the ridge. The slot shall terminate 1 foot shorter at each end than the total length of ridge vent used. 1 3/4" Truss Construction —✓ i --3114" 14 Ridge Pole Construction Installation: Place, center and conform the end of a piece of ridge vent at each end of slots. Mark the location of the end of the baffle. Strike a chalk line on both sides of the ridge to produce baffle alignment. Place vent sections centered over the slot using a chalk line. Place 12ga. 3" corrosion resistant ring shank nails from every end at pre -marked locations on the vent and then at 9" o.c. on both sides of the vent. Ridge Shingle: Using nail lines provided on top of vent. Nail cap shingles in place through vent using 12ga. corrosion resistant ring shank nails of sufficient length to provide W penetration into wood substrate. 3" ring shank nails are recommended. Net Free Area: Refer to manufacturer's published literature Minimum Slope: 3:12 NOA No.: 18-0521.04 Expiration Date: 10/18/21 Approval Date: 09/12/19 Page 3 of 7 LIMITATIONS: 1. Refer to applicable building codes for required ventilation. 2. This acceptance is for installations over asphalt shingle roof systems only. 3. All ridge vents in this Notice of Acceptance shall not be installed on roof mean heights greater than 33 feet. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 5. All approved products listed herein shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. NOA No.: 18-0521.04 Expiration Date: 10/18/21 Approval Date: 09/12/19 Page 4 of 7 DETAIL DRAWINGS NOA No.: 18-0521.04 Expiration Date: 10/19/21 Approval Date: 09/12/19 Page 5 of u.a• —i 21, ..565 UEZ131L I NOA No.: 18-0521.04 MNMWIAM COULIhm Expiration Date: 10/19/21 Approval Date: 09/12/19 Page 6 of 7 Cobra® Rigid Vent YR° , Cobra® Snow Countryrm Advanced, Cobra® Snow CountryTm AH, Cobra® Snow Countryrm Filter Depicted is for Snow Country, Snow Country Advanced, and Snow Country AH Versions END OF THIS ACCEPTANCE NOA No.: 18-0521.04 Expiration Date: 10/18/21 Approval Date: 09/12/19 Page 7 of 7