Loading...
HomeMy WebLinkAbout5284 Southwind Trl. Final ApprovalSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Grace Cole APPLICATION # : IAP 1410390 PERMIT #:56-SF-1943581 AGENT: Mike Spears (All County Septic) PROPERTY ADDRESS: 5284 Southwind Trl Fort Pierce, FL 34951 LOT: BLOCK: DOCUMENT #:F11447358 DATE PAID :06/29/2020 FEE PAID:2 5.0 0 RECEIPT #:56-PID-4468927 SUBDIVISION: ID# : 1407-433-0015-000-0 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION [01] TANK SIZE [1] 1090.00 [2] [ 02 ] TANK MATERIAL Polypropylene [03] OUTLET DEVICE [04] MULTI -CHAMBERED [ Y LNJ [05] OUTLET FILTER Polylok PL-68 [ 06 ] LEGEND 1. 70-143-11 DC4 2. [07] WATERTIGHT [08] LEVEL [09] DEPTH TO LID DRAINFIELD INSTALLATION [10] AREA [11 509.4 [2] SQFT [11] DISTRIBUTION BOX HEADER X [ 12 ] NUMBER OF DRAINLINES 1. 8.00 2. [13] DRAINLINE SEPARATION [14] DRAINLINE SLOPE [15] DEPTH OF COVER SETBACKS [ ] [27] SURFACE WATER FT [ ] [28] DITCHES 100 FT [ ] [29] PRIVATE WELLS 100 FT [ ] [30] PUBLIC WELLS FT [ ] [31] IRRIGATION WELLS FT [ ] [32] POTABLE WATER 57 FT [ ] [33] BUILDING FOUNDATIONS 7 FT [ ] [34] PROPERTY LINES 30 FT [ ] [35] OTHER FT FILLED / MOUND SYSTEM [ ] [361 DRAINFIELD COVER [ ] [371 SHOULDERS [ ] [361 SLOPES [ ] [391 STABILIZATION 07/07/2020 [16] ELEVATION [ ABOVE / BELOW ]BM 30.00 [ ] [17] SYSTEM LOCATION [ ] [18] DOSING PUMPS [ ] [19] AGGREGATE SIZE [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [21] AGGREGATE DEPTH [ ] [ ] ADDITIONAL INFORMATION [40] UNOBSTRUCTED AREA [41] STORMWATER RUNOFF [42] ALARMS [43] MAINTENANCE AGREEMENT [44] BUILDING AREA [451 LOCATION CONFORMS WITH SITE PLAN [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [47] CONTRACTOR Mike Spears (All County Sep [ ] [221 FILL AMOUNT [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [23] FILL TEXTURE [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / DISAPPROVED ]: FINAL SYSTEM [ APPROVED / DISAPPROVED ]: (Explanation of Violations on following page) `� St. Lucie CHD onmental Specialist II Brian J Ingram (ENVIRONMENTAL HEALTH) mow._ St. Lucie CHD ronmental Specialist I Hunter A Collier (Florida Department of Hea DATE: 04/23/2020 DATE: 07/07/2020 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1410390 EID1943581 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION # : AP1410390 PERMIT #:56-SF-1943581 DOCUMENT #:F11447358 DATE PAID : 06/29/2020 FEE PAID:2 5.0 0 RECEIPT #:56-PID-4468927 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd. New ST, filter, and 5x6+3x5 long BED DF. No violations, system ok to cover. Contractor notified by phone. Needs final inspection for mound system and final site grading. Well inspected at construction inspection. Final system approved. Emailed to contractor and building department. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 Ell Database v 1.0.1 AP1410390 EID'1943581