Loading...
HomeMy WebLinkAboutMoore Revision Product Approval_0001STRAP AND TIEDOWN SCHEDULE UPLIFT FORCES SUPPLIED BY THEIR MANUFACTURER OF THE PRE-ENGINEERED TRUSSES, ENGINEER MUST BE NOTIFIED IF FINAL TRUSS ENGINEERING UPLIFTS VARY FROM THIS SHEET. 2X) DENOTES NUMBER OF FASTENERS REQUIRED AT A SPECIFIC BEARING LOCATION. TRUSS INFORMATION FROM MANUFACTURER TRUSS CONNECTION TRUSS BEARING UPLIFT TRUSSTO IDENTIFICATION JOINT REQUIRED MASONRY TRUSS TO BOND BEAM WOOD FRAMING A01G 2 21 12 491/1975/840 META16, 2xHETA16 N/A A02 2 17 11 215/913/489 META16 N/A A03 2 18 10 199/886/497 META16 N/A A04 2 16 9 162/87l/501 META16 N/A A05 2 17 8 149/828/513 META16 NIA A06 10 2 17 413/138/ 446 META16 N/A A07 2 18 it 159/816/421 META16 N/q AO8G 2, 171 26, 14 185/664/757/110 META16 N/A A09 2, 19, 141 11 177/753/708/149 META16 N/A A10 2, 20, 14, 12 183/750/679/140 META16 N/A All 2, 20, 14, 12 200/728/678/110 META16 N/A Al2 2, 21, 141 12 169/783/589/126 META16 N/A A13 2, 2L 141 12 180/772/572/144 META16 N/A A14 2, 20, 13, 12 170/785/575/139 META16 N/A A15 2 21 1 14 1 147/807/625 META16 N/A A16 1 2, 14, 19, 12 1 I3P/7nn/R1aippp A17 2, 13, 19, 11 .. - 128/741/844/333 rim i No META16 N/A N/A A18 A19 2, 14, 211 11 2, 25, 17, 14 191/768/847/336 417/992/650/205 META16 META16 N/A N/A A20G 17 9 2789/2194 VGT N/A B01G 2 1 A74/874 META16 N/A B02 B03 B04 1305 B06 B07 Bob B09 B10 Bil B12 B13 B14 B15G MV2 MV4 MV6 MV8 MV10 MV12 MV14 ZCJl 2 2 2 11 12 11 11 10 11 it 10 8 8 10 1 1 1 1 1 1 6 3 4 4 4 4 2 8 7 11 2 2 2 2 2 2 2 2 2 2 2 2 3 5 5 5 5 7 4 508/508 508/508 446/446 350/449 339/441 343/432 345/430 347/428 345/430 343/432 342/434 404/495 402/496 891/841 13/32 44/49 9/53/167 11/55/158 14/66/214 18/80/262 218/210 3/181/18 META16 META16 META16 META16 META16 META16 META16 META16 META16 META16 META16 META16 META16 META16 N/A MIA N/A N/A N/A N/A NIA META16 - N/A N/q N/A N/A HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 VTCR VTCR VTCR *VTCR VTCR VTCR VTCR LS30TOP &BOTT. ZCJ3 3 2 43/147 META16 — LS30 TOP &BOTT. ZCJ5 3 2 91/157 META16 — LS30 TOP & BOTT. ZEJ2 3 2 32/147 META16 — LS30 TOP &SOTT. ZEJ3 3 2 53/148 META16 - LS30 TOP ZEJ6 3 2 137/173 META16 - LS30 TOP ZEJ7 3 2 140/174 META16 - LS30 TOP ZHJ2 3 2 40/214 META16 - LS30 TOP &LTHJA% ZHJ3 3 2 80/218 META16 - LS30 TOP &LTHJA26 ZHJ6 4 2 6 103/292/63 META16 - s30rDP &LTHJA2s ZHJ7 All CrlAl nlCr^rno�c 4 cnriru-....,.-.�.... 2 6 101/295/66 ..---.' --__-- _ META16 - LS30 TOP &LTHJA26 CONNECTORS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS CONNECTORS. ALL * VTCR CONNECTIONS SHALL BE AT EVERY BEARING POINT VERIFY CANT, OR STANDARD 12 HURRICANE STRAP PER TABLE 5 TRUSS - SEE ELEVATIONS F = FILLED WITH GROUT RF = RECESSED & FILLED W/GROUT QUANITY OF #5 REBAR AT I BOTTOM OF LINTEL CAVITY 8F16-1B/1T L QUANITY OF #5 REBAR AT TOP OF LINTEL NOMINAL HT, NOMINAL WIDTH #5 REBAR AT TOP MIN. (1) REQUIRED 1 1/2" COVER 2 crlu LINTELS SHALL HAVE A MINIMUM 4" BEARING 2•..'GROUT ON EACH END a OF LINTEL CAVITY 8" �—IN LINTEL (VARIES) NOMINAL LINTEL INFORMATION NOTE: ALL LINTEL TO 8F16-1B/1T UNLESS NOTED OTHERWISE 1. GARAGE HEADER TO BE 8F-16-1B/1T CEILING � \SINGLE 2X4 TOP BDARD PLATE NAILED TO TRUSSES 1-16d NAIL PER TRUSS DRYWALL— ❑N EACH SIDE OF WALLS 2X4 STUD WALL NON @ 16' ❑,C. BEARING FRAMED WALL SINGLE 2X4 PT BOTTOM PLATE W/ 8d CASE HARDENED CONCRETE NAILS @ 18' ❑,C, \ SLAB 2X4 NON -BEARING SCALE: 1/4" = V-0" MAX. WINDOW OPENING IN MASONRY WALL -� � DOOR OPENING � � IN MASONRY a WALL MASONRY WINDOW/DOOR BUCK ATTACHMENT SCALE: N.T.S. *NOTE: DOORS &WINDOWS SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS TO WITHSTAND THE MINIMUM DESIGN PRESSURES REQUIRED (AS NOTED IN THESE PLANS), A MAXIMUM OF A 1-1/2" FILLER MAY BE USED BETWEEN THE PRE-ENGINEERED STRAP AND THE TRUSS WITH TRUSSES COMMON NAILS IF THE DISTANCE BETWEEN THE STRAP & TRUSS IS GREATER THAN 1/2" OR LESS THAN 1-1/2". THIS ELIMINATES THE SLACK IN THE STRAP TO TRUSS CONNECTION. ROOF SHEATHING TRUSS ANCHOR USE A SIMPSON MTSM20 STRAP WHEN THE EMBEDDED STRAP IS MISSED OR FURTHER THAN 1 1/2" FROM THE TRUSS. USE (4) 1/4" X 2 1/4" (SIMPSON) TITEN OR TAPCON SCREWS (MASONRY WALL) & (8) 10d X 1 1/2" NAILS (TRUSS) FOR UP TO 1045 LBS OF UPLIFT. FOR HIGHER UPLIFT CONNECTIONS CONSULT THE ENGINEER. MISSED STRAP CONNECTION SCALE: N.T.S. TOP CORD OF TRUSS / SIMPSON 'VTCR' j FASTENERS @ EACH TRUSS INTERSECTION IF ROOF SHEATHING IS NOT INSTALLED UNDER VALLEY FRAMING, THE TOP CORDS OF THE TRUSSES SHALL BE BRACED W/ 2"%4" PURLINS FASTEN 2x4'S TO THE BOTTOM SIDE OF THE TOP CORDS W/ 2-16d NAILS @ EACH TRUSS. (ONLY REQUIRED UNDER VALLEY FRAMING) VALLEY TRUSS FASTENING DETAIL ducK MASONRY OPENINGS WINDOWS - 2"P.T. WINDOW BUCKS SHALL BE ATTACHED TO THE MASONRY WALL WITH A. X 3 3/4" TAPCONS AT 12" O.C. ON THE SIDES AND ON THE TOP OF THE OPENING. 1X BUCKS MAY BE USED ONLY W/ 3/16" DIA. TAPCONS @ 12" O.C. PENETRATING 1 1/2" MIN. INTO THE MASONRY WALL BUCK ATTACHMENT OPTION (WINDOWS) 3/16" TAPCONS INTO PRE -MANUFACTURED HOLE PENETRATING INTO THE MASONRY WALL 1 1/2" MIN. DOORS - 2X DOOR BUCKS SHALL BE ATTACHED WITH 3/16" TAPCON ANCHORS @ 16" O.C. PENETRATING 1 1/2" MIN. INTO THE MASONRY WALL 1X BUCKS MAY BE USED ONLY W/ 3/16" DIA. TAPCONS @ 16" O.C. PENETRATING 1 1/2" MIN. INTO THE MASONRY WALL BUCK ATTACHMENT OPTION (DOORS) THROUGH THE DOORJAMB INTO THE MASONRY WALL W/ 3/16" DIA. TAPCONS PENETRATING 1 1/2" MIN. INTO THE MASONRY WALL 1. DUPONT TYVEK FLUID (BRUSH FORMULATION) SHALL BE APPLIED TO THE MASONRY OPENING & THE BACK OF EACH BUCK PRIOR TO INSTALLATION. DO NOT APPLY FLUID TO EXTERIOR AREA TO HAVE STUCCO. FILL ALL CORNERS W/ FLASHING OR DUPONT SEALANT FOR TYVEK FLUID APPLIED SYSTEM. 2. WINDOW BUCKS ARE TO BE 2X4 OR 2X61 42 S.Y. PINE, PRESSURE TREATED TO 2.SCCA, BUCKS ARE TO BE FULLY BONDED TO MASONRY WITH SIKA 1A CONSTRUCTION ADHESIVE. FOR DOUBLE BUCK INSTALLATION, BUCKS ARE TO BE FULLY BONDED TO EACH OTHER. 3. FASTENERS ARE TO BE 1/4" 0 TAPCONS WITH MINIMUM PENETRATION OF 1 3/4" INTO MASONRY. USE STAGGERED SPACING OF TAPCONS EQUAL TO, OR LESS THAN REQUIRED FASTENERS SPECIFIED BY MANUFACTURER FOR FRAME TO BUCK INSTALLATION. 4. BUCKS TO BE FASTENED HORIZONTALLY AND VERTICALLY TO CONCRETE BEAMS AND COLUMNS OR GROUTED MASONRY, CONTRACTOR TO COORDINATE OPENING DIMENSIONS. WHERE %41 P.T. SHIM IS USED, WINDOW FRAME SHALL BE SECURED TO CONRCETE OR MASONRY WITH I/4" O TAPCONS OF SUFFICIENT LENGTH TO ALLOW FOR 1 %" EMBEDMENT AT SPACING SPECIFIED BY N.O.A. DOOR BUCK INSTALLATION SAME AS WINDOW WITHOUT SILL � 24 GA. EDGE-LOC 1.0 R-20 SPRAY TRUSS BEARING FOAM INSULATION BUILDING SEE ELEVATIONS FOR BEAM HGT. � OPENING ID DESIGN BOARD PRESSURE PSF SHIM AS NEEDED BOARD FOR LEVEL CLG, DOUBLE 2X4 TOP PLATE NAILED TO 3/4" FASCIA OVER 2"x4" ,I 5/8" GYPSUM BOARD ON TRUSSES 2 2x12 #2 TRUSSES 1-16d WINDOWS +36,2/ -39.4 SYP HEADER W/ AL. DRIP EDGE LINTEL BLOCK TIE BEAM NAIL PER TRUSS 1'-4° I W/ 1-#5 CONTI, EACH COURSE OVER DOOR CONTINOUOS VENTED SOFFIT VERIFY ELEV. WINDOWS +37.9/-41.1 1/2" DRYWALL � �1/2" DRYWALL 1/2" GYPSUM BOARD MIN. CEMENT FINISH PER SPECS. MULLIONS +37.9/-41.1 FI-FOIL INSULATION R-4.1 zxa STUD ix2 P.T. FURRING PER SPECS. WALL @ 16" 8" C.M.U. WALL PER SPECS. O.C. W/ SLIDING GLASS +33.9/ 37.1 SLAB REINFORCEMENT PER SPECS. SPH4 @ 4' DOORS VERTICAL REBAR IN CONC. o.c. TOP & FILLED CELLS PER SPECS. BOTTOM (SEE FOUND. & FLOOR PLAN) SWING DOOR +34.8/-29.9 /— CONCRETE SLAB PER SPECS, Rli I// INSULATION FINI HED FLOOR 0 -0 A.F.F. SINGLE 2X4 PT GARAGE DOOR +32. -39.4 • ....:=.:--:�:,,.-• — - B PLATE W/ 8d CASE •;y HARDENED 1/2' J—BOLT DR SOFFIT +37.9/-50.7 NAILS @ 18" / O.C. ANCHOR BOLTS @ 24' ❑.C. W/ VAPOR BARRIER PER SPECS, 3' WASHERS \ — -/- ROOF -89.2 \ CONCRETE VERIFY FOOTING SIZE COMPACTED FILL PER SPECS. SLAB ON FOUNDATION PLAN . ROOFING 89 2 2X4 GARAGE WALL SECTION UNDERLAYMENT SINGLE STORY TYPICAL WALL SECTION NEW SCALE: 1/4" = 1'-0" SCALE: N.T.S. TDDD N. SMITH, PE, INC. PRODUCT APPROVAL MODIFICATION 1717 INDIAN RIVER BLVD. STE 302 PER ST, LUCIE COUNTY COMMENT LETTER VERO BEACH, FL. 32960 DESCRIPTION Ph. (772) 559-3699 1/Z" ]-BOLTS OR: HI LTI KBII 12-512 KWIKBOLTS, U.S. ANCHOR W1254, RAWL-STUD 7424 W/2" DIA. X 1/S" WASHERS 2"X6" P.T. ON ROUGH OPENING (�1/2" BOLTS REQUIRED REFE TO GARAGE OR M�/ NUFACTURER FOR BOLT a, i. OVERHEAD GARAGE DOOR BUCK CONNECTION ON MASONRY DETAIL FASTEN 2% P.T. TO UNDERSIDE OF LINTEL AS PER SCHEDULE; — NAIL 2X FRAMING TO THIS TAPCONNED ZX W/ lOd @ l0" O.C. • BEYOND OPENING, FASTEN 2X TO BLOCK AS PER SCHEDULE. J/I FASTEN 2%P.T. MEM BER TO MASONRY AS FOLLOWS: FILLED CELLS &LINTEL: 1/4" X 4" TAPCONS @ 18" O.C. HOLLOW CELLS: 1/4" X 4" TAPCONS @ 12" O.C. NAIL OTHER REQUIRED FRAMING TO TAPCONNED 2X3S W/ lOd NAILS @ 12" O.C. STAGGERED. WRAP FRAMING W/ 1/2" CDX PLYWOOD NAIL W/ Bd NAILS @ 12" O.C. ON ALL EDGES FRAMING DETAIL FOR POCKET SLIDING GLASS DOORS PRODUCT APPROVAL SUBMITTAL AFFIDAVIT PRODUCT DESIGN MANUFACTURER MODEL # PRODUCT PRESSURE APPROVAL +67.5/ -67.5 CUSTOM WINDOW AW8450 VINYL SYSTEMS, INC. AWNING WINDOW FL# 7060.1 +45.0/-45.0 CUSTOM WINDOW DH-6500 IMPACT VINYL SYSTEM INC. DOUBLE HUNG FL# 17792.1 +50.O/-50,0 CUSTOM WINDOW SYSTEMS INC. PW-6550 FL#17794.2 +65.0/ -65.0 CUSTOM WINDOW SGD 8800 FL#20838.1 SYSTEMS INC. I +65.0/-70.0 PLASTPRO E FIBERGLASS DOOR FL# 17184.5 +48/ -52 DAB DOORS MODEL# 824/811 FL# 15371.1 +41.7/ -68.8 KAYCAN LTD ALUMINUM SOFFIT 116 INTEGRITY METALS LLC +NA/ 150 TRI-BUILT MATERIAL GROUP, LLC SV CRIMP TRI-BUILT S/A HT TU UNDERLAYMENT FL #24564.2 FL# 29444.4 FL # 16048.1 F �HO.R�ACZ RES�D]ENC]E JL JL P . JLl JL 'LJI, N 0 JL JLJ 4J 20 CONLEY PL FORT PIERCE, FL. 34951 WALL SUPPORT EDETAILTO I �I WHERE HIP MEETS RIDGE BETWEEN TRUSSES, INSTALL 2 X 12 BOARD TO ACCEPT HIP CATS (2 X 12 MAY NEED TO BE CUT TO SLOPE .NAIL WITH 3-16d NAILS PER END RIDG MATCr I I HIP CATS SHALL BE I I CONTIN UODUS TO RIDGE I (2) 16d NAILS PER END W/ HIP TRUSS (HT) I I I I HIP GIRDER T TRUSS (HGT) I I I — I I I a _ \` No I I i � % I I I I I I I n EFT S PLAN, USS TO HIP TRUSSES — NAIL HIP JACK TRUSSES W/ TOP CHORD 2- #10 COMMON BOTTOM CHORD 2-#10 COMMON •� SUB -FASCIA BOARD ROOF SHEATHING TO BE J CARRIED OVER 2 SPANS MINIMUM @ ALL LOCATIONS NAIL END OF JACK TRUSSES W/ � HIP JACK TRUSS (HJT) TOP CHORD 3- 16d COMMON BOTTOM CHORD 3-16d COMMON 16d NAIL HAS A MAXIMUM JACK TRUSS CONNECTION @ 1LATERAL RESISTANCE OF HIP AND GIRDER TRUSSES WOOD STUCCO SPECIFICATIONS 1. SPECIFICATIONS FOR APPLICATION OF PORTLAND CEMENT BASED STUCCO, ADDITIVES, METAL LATH AND STUCCO TERMINATION AND JOINT ACCESSORIES SHALL CONFORM TO REQUIREMENTS IN FLORIDA BUILDING CODE, LATEST EDITION, SECTION 2512, EXTERIOR PLASTER AND MEET ALL REQUIREMENTS OF ASTM C1063, LATEST EDITION. 2. USE PORTLANO CEMENT BASED STUCCO SPECIFICATIONS FOR BASE COATS AND FINISH COAT APPLICATION AND FOR CURING, AND USE MANUFACTURER SPECIFICATIONS FOR LATH, BONDING AGENT, AND STUCCO WATERPROOFING PRODUCTS APPLICATION, 3. EXTERIOR WALLS OF F RAME CONSTRUCTION THAT ARE TO RECEIVE STUCCO SHALL BE PROVIDED WITH A WARM RESISTIVE BARRIER COMPLYING WITH ASTM D226 TYPE 11 PREFERABLY CARLISLE CCW705 PEEL AND STICK ATTACHED TO THE SHEATHING WITH THE REQUIRED FLASHING AS DESCRIBED IN NOTE 6 OF THE EXTERIOR WOOD WALL CONSTRUCTION SPECIFICATIONS. 4. A 80ND BREAK SHALL BE PROVIDED BETWEEN THE WATER RESISTIVE BARRIER AND THE STUCCO CONSISTING OF TWO (2) LAYERS OF AN APPROVED WATER RESISTANT BARRIER. THE FIRST LAYER IS PROVIDED AGAINST THE SHEATHING AS DISCUSSED IN NOTE (3.) ABOVE AND THE SECOND LAYER IS ACHIEVED WITH TYVEK STUCCO WRAP, 5. PAPER BACKED "TILATH" DIAMOND MESH SELF -FURRED LATH (TYPE 2.5 LBS. AS MANUFACTURED BY THE ALABAMA METAL INDUSTRIES CORPORATION) MEETING FEDERAL SPECIFICATION U-B-790A FOR THE PAPER MAY ALSO BE INSTALLED IN LIEU OF SEPARATE WATER RESISTANT BARRIER AND LATH. "TILATH" APPLIED WITH 16 GAUGE STAINLESS STEEL STAPLES, WITH MINIMUM 3/4" PENETRATION INTO FRAMING, 6" O.C. VERTICALLY AND 16" O.C. HORIZONTALLY. LEAVE A 'SPACE AT PANEL EDGE AND END JOINTS TO ALLOW FOR EXPANSION. 6. CONTROL ]DINT PLACEMENT IS ALWAYS REQUIRED AT THE JUNCTURE OF DISSIMILAR TYPES OF WALLS, 7. PORTLAND CEMENT BASED STUCCO SHALL BE APPLIED IN A 3 COAT METHOD FOLLOWING ASTM C926 TO A NOMINAL 3/4" THICKNESS. BASE COAT STUCCO, SHALL BE APPLIED TO COVER LATH AND CROSS RAKED TO PROVIDE AN ADEQUATE KEY FOR THE BROWN COAT. SCRATCH COAT SHALL SET AT LEAST TWO (2) DAYS BEFORE THE APPLICATION OF BROWN COAT OR AS SPECIFIED BY MANUFACTURER. BROWN COAT SHALL CURE AT LEAST THREE (3) DAYS BEFORE APPLICATION OF FINISH COAT OR AS SPECIFIED BY MANUFACTURER, FINISH COAT STUCCO SHALL BE APPLIED TO A NOMINAL 1/8" MINIMUM AND FLOATED OR TEXTURED AS DESIRED. STUCCO PRIMER SHALL BE APPLIED BETWEEN ALL COATS 8. .PROVIDE CORNER BEAD REINFORCEMENT. 9. A MINIMUM .019 INCH, 26 GAGE, CORROSION RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2" SHALL BE PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C926. THE WEEP SCREED SHALL BE PLACED A MINIMUM OF 4" ABOVE THE EARTH OF 2" ABOVE PAVED AREAS AND BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. THE WATER RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE OF THE WEEP SCREED, STUCCO JOINTS: 1. PROVIDE TWO PIECE EXPANSION JOINTS IN THE STUCCO SYSTEM WHERE BUILDING MOVEMENT IS ANTICIPATED: AT ]DINTS IN THE SUBSTRATE CONSTRUCTION, WHERE THE SYSTEM IS TO BE INSTALLED OVER DISSIMILAR CONSTRUCTION OR SUBSTRATES, AT CHANGES IN BUILDING HEIGHT, AT FLOOR LINES, AT COLUMNS AND CANTILEVER AREAS, 2. PROVIDE ONE PIECE EXPANSION JOINTS EVERY 144 SF CUT AND WIRE TIE LATH TO THE EXPANSION JOINT ACCESSORY SO LATH IS DISCONTINUOUS BENEATH THE ACCESSORY. DO NOT EXCEED LENGTH TO WIDTH OF 2-1/2" TO 1 IN EXPANSION JOINT LAYOUT AND DO NOT EXCEED MORE THAN 18 FEET IN ANY DIRECTION WITHOUT AN EXPANSION JOINT. WHERE CASING BEAD IS USED BACK TO BACK AS THE EXPANSION JOINT, BACK THE JOINT WITH BARRIER MEMBRANE. 3. PROVIDE ONE PIECE EXPANSION JOINTS AT THROUGH WALL PENETRATIONS, FOR EXAMPLE, ABOVE AND BELOW DOORS AND WINDOWS. 4. PROVIDE MINIMUM 3/8" WIDE JOINTS WHERE THE SYSTEM ABUTS WINDOWS, DOORS AND OTHER THROUGH WALL PENETRATIONS. 5. PROVIDE APPROPRIATE ACCESSORIES AT STUCO TERMINATIONS AND JOINTS. 6. PROVIDE APPROPRIATE SEALANT AT STUCCO TERMINATI DNS, TYPE I METHOD OF ATTACHMENT IMPACT #10 WOOD SCREW EMBEDDED 1 1/2" INTO BUCK @ EACH FACTORY HOLE IMPACT #10 WOOD SCREW EMBEDDED 1 1/2" INTO BUCK @ EACH FACTORY HOLE (4) # 12 (G5) SCREWS EMBEDDED 1 3/8" INTO WOOD BUCK IMPACT & EACH PREDRILLED MANUFACTURED HOLE, TOP & BOTTOM OF MULLION #10 SS WOOD SCREWS EMBEDDED 1 3/8" INTO BUCK @ IMPACT EACH FACTORY HOLE (TOP & BOTTOM: 6" FROM CORNERS & 12" O.C. MAX, SIDES 6" FROM CORNERS & 18" O.C. MAX. 1/4" X 2 1/2" PFH ELCO SCREWS MIN. EMBEDDED 1 1/4" IMPACT INTO BUCKS @ 6" FROM CORNERS & 14" O.C. ON SIDES W/ 1/4" X 2 1/4" PFH SCREW 6" INTO CONCRETE SLAB IMPACT ATTACH W/ 5/16" X 1 5/8" LAG SCREWS/ HEX WASHER HEAD TYPE A @ EACH MANUFACTURERS TRACK BRACE ATTACH F-CHANNEL TO WALL W/ MIN. 0,097" DIA HARDENED NA T-NAIL OR STUB NAIL INTO WALL (MAX. SPACING 24" O.C.) & W/ (3) 48 GA X 1 1/4' WIDE CROWN X 1" MIN LENGHT STAPLES SUB FASCIA NA ATTACH #10-15 WOODTITE FASTENER SPACED @ 12" O.C. HAND ROLLER AND/OR WEIGHTED ROLLER TO ENSURE NA THERE ARE NO VOIDS, AND ENSURE THERE ARE NO VOIDS/BRIDGING AT SIDE AND END -LAPS REVISIONS TO THIS PAGE (7-1-2020) CONSISTED OF MODIFICATIONS AND ALTERNATE PRODUCTS TO THE PRODUCT APPROVA) L� 2\� NOT VALID WITHOUT THE SIGNATURE AND THE DRAWN LD 'cTaltle to all documents which bear the ORIGINAL INK SEAL OF A FLORIDA LICENSED pyrlght of Todd N. Snith, P,E. Is vested solely In Todd N. Snith, P.E. these ENGINEER DESIGNED LD documents are provided to {he o ner \Y�Illll ll/r/ ' alely In connection with {his protect, \\X��^,Dad •� yy// CHECKED TNS Any other use or reuse of these y documents or nny reproduction, display, `% ,/ snle, or other disposition of these documents w y anyone s pof Tod � �. �• DATE MAR. 2C prohidited Ithout ne Is { f Todd N. Snith, P.E. pursuant to the Federal �� SCALE SHOWN Copyrleh{ r : O _ @ 2019, TDDD N. SMITH, P.E. _ Z SHEET 5 TDDD N. I:TF, Pti$?y4'082Em� Joe # 20021 N•.......ye \�. n JON\