HomeMy WebLinkAboutDakota Brady revisionsCool and Cobb Engineering Company __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ 203 W. Main St. Avon Park, FL 33825 Office: (863) 657-2323 Fax: (863) 657-2324 Date: 6/30/20 Job: Dakota Brady Location: 5508 Spruce Dr Ft Pierce, Fl 34982 PILING DESIGN ANALYSIS The load requirements for the pilings designed to assist in supporting the identified areas of the subject residence were determined. The selected piling locations and the specific piling are identified on the Pier Identification and Location Plan attached. The calculated total loads on the piles in the specific location, including both dead and live loads are documented in the attached table which is designated as Attachment “A”. This pile design is approved and certified as meeting all the requirements of the Florida Building Code 2017 6th Edition, and good engineering practice. This is not to be the primary support structure, but a supplement support to assist in support of the weight of the structure, which will reduce the total pressure on the existing soils. After completion of installation, Cool and Cobb Engineering Company shall be supplied with a log of the location of each pile installed so they can evaluate the installation and prepare the “As Built” drawings. General Notes: 1.A log of each pile to be kept by Contractor noting depth and final pressure installed for each pile. 6/30/20 Carl Cool, P.E. State of Florida Professional Engineer No. 16921 1 2 Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825 6/30/2020 Carl E. Cool, P.E. PE# 16921 PT SYP 4" x 6" Date: Job: Location: PILE NO. 1 6,400 lbs 2 6,400 lbs 6,400 lbs Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825Carl E. Cool, P.E. PE# 16921 Cool and Cobb Engineering Company Maximum Total Load on Pile: 6/30/2020 6/30/2020 Dakota Brady 5717 Sea Trout Pl Apollo Beach, Fl. 33572 Attachment "A" Total Load on Pile (Live Load + Dead Load) TOTAL CALCULATE LOAD Cool and Cobb Engineering Co.203 W. Main St.Avon Park, FL 33825Carl E. Cool, P.E.PE# 169216/30/2020 Crawl Space Jack, Typ. 4" X 6" PT SYP Beam, Typ. 16" x 16" x 4" Concrete Footing, Typ.(3) #5 Rebar Both Ways (6 Total) Set On Chairs @ 12" O.C.(Max) , Typ. (4) 3" N0. 10 Deck Screws , Typ Toenail 4" x 6" Beam to Floor Joists Using Galv. Deck Screws, Typ. Existing Grade Cool & Cobb Engineering Company 203 West Main St. Avon Park, FL 33825 Carl Cool, P.E. FLA LICENSE NO 16921 (863) 657-2323 Office (863) 657-2324 Fax carl@coolandcobb.com Seal: 6/30/2020 CRAWLSPACE JACK TO BEAM DETAIL Scale: NTS *NOTES: -MIN. 3,000 P.S.I. CONCRETE @ 28 DAYS -All Steel To Be Grade 60