HomeMy WebLinkAboutOwens Corning UnderlamentBusine"4s"'s""&'�'ProfessionaI r i
FigSCSS Home I Log In I User Registration Not Topics I submit surcharge Stats & Facts Pubkications ' Contact Us UOS Site Map Links Search
bp
� �1
d r { -ji: },Product Approval
y USER: Public User
Product Raps,[ M� Product or Application S_arch �pii�atiar List Application Detail
FL #k
FL11502-R10
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning Roofing and Asphalt, LLC
Address/Phone/Email one Owens Corning Parkway
Toledo, OH 43645
(740) 321-6345
Greg. Kee ler@owenscorn in9 -corn
Authorized Signature Keeler Greg
Greg.Keeler@owenscorning.com
Technical Representative Greg Keeler
Address/Phone/Emall 2790 Columbus Road
Granville, OH 43023
(740)321-6345
greg. keeler@owenscorni ng. com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Undcrlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professionat Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31RO20
Validated By John W. Knezevich, PE
Vaildation Checklist - Hardcopy Received
Certificate of Independence FL11602 R10 COI 2019 O1 COI NIENIINtN.pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D226 (physicals) 2009
ASTM D4798 2011
FRSA/TRI April 2012 2012
TAS 117(B) 1995
UL1897 2012
1
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option ❑
Date Submitted
10/17/2019
Date Validated
10/17/2019
❑ate Pending FBC Approval
10/20/2019
Date Approved
12/10/2-019
FL # Model. Number or Name
1160211 Titanium Roof Underlayments
Llmlts of Use
Approved for use in HVHZ: No
Approved for use outside H V HZ: Yes
Impact Resistant: N/A
Design pressure: +N/A/-45
Other: 1.) The design pressure noted herein pertains to use of
a specific underlayment system beneath foam -on tile sytsems.
Refer to ER Section 5.6.3 for details. 2.) Refer to ER Sections 5
and 6 for other Limits of Use.
Description
Synthetic sheet -type roof underlayments
installation Instructlons
FL11602 R10 II 2019 10 FINAL ER FL116Q2- 10._pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL11602 R10 AE 2019 10 FINAL R FL11602-R-pdf
Created by Independent Third Party: Yes
Contact Lls :: 2601 Blair Song PosdrT Iaha=e FL 3Z394 Phone: 850-487-18Z_4
The State of Florida is an AA/EEQ employer. QQpyrIght 2007-2013 State of Florida.:: Friya Stag :: Acres Ili y� Statement =: Refund Statement
Lander Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact B50.487.1395. 'Pursuant to Section 455.275{1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, r,S. must provide the Department with an email address if they have one. The emails
provided may be used for ofricial communication with the licensee. however email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can he made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here_
Product Approval Accepts:
W]
Crecoli: Gard
Safe
NEMO ( etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
REPORTEVALUATION
Owens Corning Roofing and Asphalt, LLC Evaluation Report 111980.11.08-R11
One Owens Corning Parkway FL11602-R10
Toledo, OH 43659
(740) 321-6345
Date of Issuance: 11/03/2008
Revision 11: 10/17/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6' Edition 12017) Florida Building Code sections noted
herein.
DESCRIPTION: Titaniumm Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility locations). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through S.
Prepared by:
Robert J.M. !Nieminen P.E.
'�`' � "� T"
�s�sp-= a;,;��
The fats"smite seal appearing was aErthorixed by Robert
x
Florida Registration No. 59166, Florida OCA ANE1983
`�-
�1�,;; .i;=•„
Nieminen, P.E. on 10117/2019. This does notserve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or ccntroIIed by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
Q2018 NEMOETC, LLC
ONEMOletc.
ROOFING COMPONENT EVAWATION:
®n
Product Category:
Roofing
Sub -Category:
U nderlayment
Compliance Statement: Titanium'''' Roof Underlayments, as produced by [Owens Corning Roofing and Asphalt, LLC,
have demonstrated compliance with the intent of the following sections of the 6" Edition (2017)
Florida Building
Code through testing in accordance
with applicable sections the following
Standards. Compliance
is subject to the
installation Requirements and Limitations / Conditions of Use set forth herein.
STANDARDS,
Section
Propert
Standard
Year
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, R905.1.1 Exception
Unrolling, Breaking Strength, Phability
A5TM D226
2009
1507.1.1, R905.1.1 Exception
Tear Strength
ASTM D1970
2015
1507.1.1, T1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
TAS 110
Accelerated Weathering
ASTM D4798
2011
TAS 110
Pull -through resistance
TAS 117(B)
1995
3- REFERENCES;
Date
Enti
Examination
Reference
ERD (TST6049)
Physical Properties
115010.04.09
04/29/2009
ERD (TST6049)
Physical Properties
115010.05.10
05/14/2010
ERD (TST6049)
Physical Properties
135520.06.11
06/15/2011
ERD (TST6049)
ASTM D226
138010,08.11
08/11/2011
ERD (TST6049)
Wind Uplift
135520.08.11-1
08/12/2011
ITS (TST1509)
ASTM D226
311801000Q-003
04/26IN07
tTS(TST1509)
ASTM D226
3130639COQ-002A
08/21/2007
ITS (TST1509)
Physical Properties
3126617COQ-005
10/31/2007
ITS (TST1509)
ASTM D226
101823107COG-011
01/23/2015
ERD (TST6049)
Physical Properties (NH)
4j-0C-19-SSUDL-01.A
06/14/2019
Owens Corning
Product equivalency
Declaration
06/18/2018
PRi(TST5878)
ASTM D1970
OCF-341-02-01
09/20/2017
PRI (TST5878)
ASTM D1970; Tear strength
OCF-331-02-02
10/03/2017
PRI (TST5878)
ASTiVi D1970; Tear strength
OCF-332-02-07
10/03/2017
PRI (TST5878)
ASTM D 1970; Tea r stre ngt h
OCF-334-02-02
10/03/2017
PRI (TST5878)
FRSA/TRI April 2D12 (04-12), partial
OCF-343-02-01
11/09/2017
PRt(TST5878)
ASTM D4798
OCF-341-02-01
11/27/2017
PRI (TST5878)
TAS 117(B); Pull -through
OCF-422-02-02
04/03/2018
PRI (TST5878)
FRSA/TRI April 2012 (04-12), partial
OCF-425-02-01
08/13/2018
PRI (TST5878)
ASTM D226 / ASTM D4799
OCF-331-02-03_ R1
05/07/2019
PRI (TST5878)
ASTM D226 / ASTM D4798
OCF-332-02-01 R1
D5/07/2019
PRI (TST5878)
ASTM D226 / ASTM D4798
OCF-334-02-01 R1
05/07/2019
PRi(TST5878)
UL1897
137ST002
07/10/2019
PRI (TST5878)
Tensile adhesion
OCF-507-02-01
08/13/2019
ITS (QUA1673)
QuaIity Control
ITS Listings
Current
ITS (QUA1673)
Quality Control
Service Confirmation
09/30/2017
NEMO ETC LLC Evaluation Report 111984.11.08-Rll
Cerdf sate of Aurhanzarion #32455 Vrt EDITION (2017) FBC NON-HVH? EVALUATION FL? 1602-R10
Titanium Roof Undedayments Revision 11: 10/17/2019
Page 2 of 8
Product Specification Plantis
4.1 Titanium"" PSU-30 ASTM D197D Dubai, UAE &
and FRSA/TRI Brentwood, NH
April 2012
4.2 TitaniumTM UDL-25 FBC 1507.1.1 Qingdao, China
& R905.1.1
(Exception)
4.3 Titanium'" UDL-30 FBC 1507.1.1 Mission, BC,
& R905.1.1 Canada &
(Exception) Qingdao, China
*NEMOietc.
Descri tion
unreinforced polymer modified bitumen material adhered
to the underside of a polymer -coated, synthetic woven
sheet. The underside is backed with a release film. Unit
weight 24 lbs/square
synthetic sheet -type underlayment comprised of a woven
core coated on one side with a polymer coating. Unit
weight 2.5 Ibs./square
synthetic sheet -type underlayment comprised of a woven
core coated on both sides with a polymer coating. Unit
weight 4.0 ibs./square
4.4 Titanium"" UDL-50 FBC 1507.1.1 Mission, BC, synthetic sheet -type underlayment comprised of a woven
& R905.1.1 Canada & core coated on both sides with a polymer coating. Unit
[Exception] Qingdao, China weight 4.7 lbs./square
5.1
5.2
5.3
5.4
5.5
This is a building code evaluation. Neither NEMQ ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance uniess retained specifically for that purpose.
This Evaluation Report is not for use in FBC HVH7 jurisdictions.
Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
Titanium'" Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request maybe made to the Authority Having Jurisdiction
for approval based on this evaluation combined with supporting data for the prepared roof covering.
Allowable Roof Covers:
TABLE
1: ROOF COVER OPTIONS
Asphalt
Wood Shakes
Underfayment
Shingles
Nail -On -rile
Foam -On Tile
Metal
&Shingles
Slate
Titanium PSU 30
Yes
Yes
Yes
(See 5.5.1)
Yes
Yes
Yes
Titanium UDL-25
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Titanium UDL-30
Yes
{Base sheet in 2-ply
(Base Sheet in 2-ply
system)
system}
Titanium UDL 5p
Yes
No
No
Yes
Yes
Yes
Evaluation Report 111980.11.08-R11
NE[1RD ETC, LLC
Certificate afAuftriration #324S5 6" EDITION (2017) FBC NON-HVHI EVALLIATI0N FL11&02-R10
Titanium Roof underlayments Revision It-10/17/2019
Page 3 of 8
A & I
WNEMOjetc.
6.3.3 Slopes of 4:12 or greater:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. When batten systems are to be
installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the
battens.
6.3.4 Slopes of 2:12 to less than 4:12:
End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 25-inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
Begin by fastening a 25-inch wide strip along the eaves. Place a full -width sheet over the starter, completely
overlapping the starter course. Continue upslope, maintaining minimum 25-inch side (horizontal) laps, resulting in
a double -layer application.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4-inch o.c.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.4 Titanium='° PSU-30:
6.4.1 Non -Tile Installations:
Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements.
Titanium'' PSU-30 shall be back -nailed in accordance with Owens Corning published installation requirements.
6.4.2 Nail -On Tile Applications:
Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in
FRSAITRI April 2012 (04-12), and Owens Corning published requirements. Titanium"' PSU-30 shall be back -nailed
max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in
accordance with Owens Corning published installation requirements.
Refer to Section 5.8 for the staging limitations.
6.4.3 Foam -On Tile Applications:
Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in
FRSACTRI April 2012 (04-12), and Owens Corning published requirements. Titanium'" PSU-30 shall be back -nailed
max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga_, 1-5/8-inch diameter tin caps in
accordance with Owens Corning published installation requirements.
Refer to Table 1A for allowable tile adhesives.
Refer to Sections 5.6.1 for wind uplift limitations.
Refer to Section 5.8 for the staging limitations.
6.5 Titanium 2-Ply System:
6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UAL-30 (top -surface primed or sheet inverted)
mechanically attached to the wood roof deck followed by Titanium PSU-30, self -adhered.
6.5.2 Non -Tile Applications:
Install Titanium UOL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium
PSU-30 in accordance with Section 6.4.
MEMO ETC, L! C Evaluation Report 111980.11.08-Rll
Certffcote of Authorization #324S5 V" EDMON (2017) FSC NOW-HVFi7 EVALUATION FL11602-RIG
Titanium Roof U nderl ayments Revision 11:10/17/2019
Page 7 of 9
OMEMO i etc.
6.5.3 Nail -On Tile Applications:
For nail -on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with
FRSA/TRl April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM
D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4.
Refer to Section 5.8 for tile staging limitations.
6.5.4 Foam -On Tile Applications:
For foam -on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with
Section 5.6.1 herein. Then apply Titanium PSU-30 in accordance with Section 6.4
Refer to Table 1A for allowable the adhesives.
Refer to Section 5.6.1 for wind uplift limitations.
Refer to Section 5.8 for tile staging limitations.
7. BuILOIN.GPERMIT REQUIREMENTS::
As required bythe Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for plants covered under Rule 6IG20-3 QA requirements. Refer
to Section 4 herein for product & production locations having met codified physical properties specifications.
s
Intertek Testing Services NA Inc. — QUA1673; (604) 520-3321
- END OF EVALUATION REPORT -
NEMO ETC, U-C Evaluation Report 111980.11.08-R11
CertlficateafAuthoriratfon #132455 6r" EDITION (2017) FBC NON-14VHZ EVALUATION FL11502-R10
Titanium Roof Underlayments Revision 11: 10/17/2019