Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGYEFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: WYNNE THE ROYALE IMPACT BuilderName: WYNNE Street: WYNNE DEV. Permit Office: ST.LUCIECOUNTY City, State, Zip: FT. PIERCE, FL, PermitNumber: � Owner: \\� , t,(µ �� Jurisdiction: Designt-ocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1688.7 sqft.) Insulation Area 2. Single familyor multiple family Single-family a. Concrete Block- InlInsul, Exterior R=4.1 1448.70 ft2 b. Frame -Wood, Adjacent R=11.0 240.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1750.0 sqft.) Insulation Area a. UnderAftic(Vented) R=30.0 1720.00 ft2 6. Conditioned floorarea above grade (ft2) 1720 b. Knee Wall (Vented) R=19.0 30.00 112 Conditioned floorarea belowgrade(ft2) 0 c. N/A R= ft2 11. Ducts R 112 7. Windows(155.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 155 a. U-Factor: SgI, U=1.04 115A2ft2 SHGC: SHGC=029 b. U-Factor: SgI, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency - SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15:00 c. U-Factor. NIA ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50, SHGC: Area Weighted Average Overhang Depth: 3.316 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems 8. FloorTypes (1720.0 sqft.) Insulation Area a. Electric Cap:50gallonsEF: a. Slab -On -Grade Edgelnsulation R=0.0 1720.00 ft2 b. Conservation features 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 56.10 PASS Total Baseline Loads: 56.25 I hereby certify that the plans and specifications covered by Review of the plans andgt7g�Ti;a� this calculation are in compliance with the Florida Energy specifications coveredby this - Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 4-20-202kao this building will be inspected for compliance with Section 553.908 N k I hereby certify that this building, as designed, is in co pliance Florida Statutes. with the Florida Energy CodD.3 OWNEZE�NT: BUILDING OFFICIAL: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factorysealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). REVIEWED FOR ..ODE r 9COMPLIANCE C6th 4/20/20202:55 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBEdiLn`(2017, m'bYaQS eeTY Pagel of Fl f COP r FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE ROYALE IMPA Bedrooms: 3 Address Type: SlreetAddress Building Type: User ConditionedArea: 1720 Lot# OwnerName: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: BuilderName: WYNNE RotateAngle: 90 Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DallyTemp V DesignLocation TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 EnbreHouse 1720 13760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Healed 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimelerR-Value Area JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 52ft 0 343W ---_ 0 1 0 2 Slab -On -Grade Edge Insulation WIC 1ft 0 63 ft' ____ 0 1 0 3 Slab -On -Grade Edge Insulation M. BATH 8ft 0 56 ft' ____ 0 1 0 4 Slab-On-GradeEdge Insulation KITCHEN 1ft 0 172 ft' ___- 0 1 0 5SIab-On-Grade Edgelnsulation BATH 5ft. 0 45ft' ____ 0 1 0 6 Slab-On-GradeEdge Insulation BEDROOM2 42.6ft 0 204W ____ 0 1 0 7 Slab -On -Grade Edge Insulation ENTRY 6.3ft 0 98 ft' _--_ 0 1 0 4120/20202:55 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2of5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 8 Slab-On-GradeEdgelnsulation LAUNDRY 6ft 0 42 ft' ---- 0 1 0 -9SIab-On-GradeEdgelnsulalton GREAT/DINING 48ft 0 528ft' ---- 0 1 0 1 OSlab-On-GradeEdge Insulation BEDROOM 13ft 0 169ft2 ---- 0 1 0 ROOF _ / Roof Gable Roof Red Solar SA Emitt Emilt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 GableorShed Metal 1813ft2 286 112 Light N 0.6 No 0.7 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio(I in) Area RBS IRCC 1 Fullattic Vented 150 1720 ft2 N N CEILING # CellingType Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAtBc(Vented) BEDROOM 30 Blown 343 ft' 0.1 Wood 2 UnderAttic(Vented) WIC 30 Blown 63 ft2. 0.1 Wood 3 UnderAttic(Vented) M.BATH 30 Blown 56 ft' 0.1 Wood 4 UnderAttic(Vented) KITCHEN 30 Blown 172 ft- 0.1 Wood 5 UnderAttic(Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 llnderAttic(Vented) BEDROOM 30 Blown 204ft2 0.1 Wood 7 UnderAttic(Vented) ENTRY 30 Blown 98 ft' 0.1 Wood _ 8 UnderAtic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 UnderAttic(Vented) GREATIDINING 30 Blown 528 R2 0.1 Wood 10 UnderAttic(Vented) BEDROOM 30 Blown 169 ft2 0.1 Wood 11 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o _ 1 N=>E Exterior Concrete Block- Int lnsul BEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 2 S=>W Exterior Concrete Block- Int lnsul BEDROOM 4.1 .29 0 8 0 232.0 ft' 0 0 0.4 0 3 W=>N Exterior Concrete Block- Int lnsul BEDROOM 4.1 14 0 8 0 112.0 1`12 0 0 0.4 0 4 S=>W Exterior Concrete Block-Int lnsul M.BATH 4.1 8 -0 8 0 64.0 ft' 0 0 0.4 0 5 N=>E Exterior Concrete Block-Int lnsul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 6 N=>E Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 14 0 8 0 112.0ft2 0 0 0.4 0 _ 7 NE=>SE Exterior Concrete Block- Int lnsuBEDROOM.2 4.1 2 10 8 0 22.7 112 0 0 0.4 0 8 E=>S Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 9 SE=>SW Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 2 10 8 0 22.7 ft' 0 0 0.4 0 10 S=>W Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 14 0 8 0 112.0ft2 0 0 0.4 0 11 NE=>SE- Exterior Concrete Block -Int lnsul ENTRY 4.1 1 5 8 0 11.3 ft' - 0 0 0.4 0 4/20/20202:55 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3of5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 12 E=>S Exterior Concrete Block-Intinsul ENTRY 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 13 S=>W Exterior Concrete Block- Int lnsul LAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 14 N=>E Exterior Concrete Block -Int lnsuGREAT/DINT4.1 28 0 8 0 224.0 ft- 0 0 0.4 0 15 W=>N Exterior Concrete Block -Int lnsul3REAT/DINT 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 16 N=>E Exterior Concrete Block- Int lnsuBEDR00M 3 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 17 N=>E Garage Frame -Wood BEDROOM 11 30 8 240.0 ft2 0.23 0.4 0 DOORS # Omt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 E=>S Insulated ENTRY None .32 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC imp Area Depth Separation IntShade Screening 1 W=>N 3 Metal Low-ESingle Yes -1.04 0.29' N 32.4 ft' 1 It 0 in 1 It 5 in Drapes/blinds Exteriors 2 S=>W 4 Metal Law-ESingle Yes 1.04 0.29 N 6.9 ft' 1 It in 1 ft6 in None None 3 E=>S 8 Metal Low,ESingle Yes 1.04 0.29 N 23.2 ft2- 1 ft 0 In 1 It 5 In None None 4 N=>E 14 Metal Low-ESingle Yes 1.04 0.29 N 36.8 ft2 1 ft 0 in 1 It 5 in None None 5 W=>N 15 Metal Low-ESingle Yes 1.11 0.27 N 40.0 ft2 10It0in 1ft5in None None 6 N=>E 16 Metal Low-ESingle Yes 1.04 0.29 N 16.2It' 1 ft 0 in 1 ft 5 in None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 300 ft2 300 ft2 30 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000356 1605.3 88.13 165.74 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Black Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8kBtu/hr 1 sys#1 COOLING SYSTEM # SystemType Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnit/ Split Single SEER:.15 34.8.kBtulhr cfm 0.85 1 sys#1 4/20120202:55 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FOG 6th EdiGon(2017) Compliant Software Page 4of5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9gal 120deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # � CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS / —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area LeakageType Handler TOT OUT ON RLF Heat Cool 1 Attic 6 155 ft' Attic 55 ft' DefaultLeakage Attic (Default) c(Default) c 1 1 TEMPERATURES ProgramabliaXT,]hermostat:X]Y Ceiling Fans: - Heatinov g Jan Feb ([�xj�J Mar [ ] [ ] AApr �J [X� l 1 Jun (] Jul D0' [ ] Aug 00 [ ] Sep (] (r)(') Doe Venting I 1 Jan (1 Feb l J l l (Xl Mar lnJ fXl May L 1 Jun (]Jul (1 Aug I 1 Sep L J Oct [X] lxl Nov Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 - 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(IND) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Healing(WEH) AM .66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness FumitureFrection Space Default(8lbs/sq.fL 0 ft' Oft 0.3 BEDROOM Default(8lbs/sq.ft. ft' it 0.3 WIC Default(8lbs/sq.ft. ft' ft 0.3 M. BATH Default(81bs/sq.ft. ft- It 0.3 KITCHEN Defaull(8lbs/sq.ft. ft' it 0.3 BATH Default(Blbs/sq.ft. ft' it 0.3 BEDROOM Default(8lbs/sq.ft. ft' ft 0.3 ENTRY Default(Blbs/sq.ft. ft' it 0.3 LAUNDRY Default(8lbs/sq.ft. ft' it 0.3 GREAT/DINING , Default 81bs/s .ft. ft' it 0.3 BEDROOM 3 4/20/2020 2:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edilion (2017) Compliant Software Page 5 of 5 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: U Owner: Jurisdiction: to Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed In the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dro ed /soffit Y dropped ceilin 9 the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windom, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (Including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation Installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be out to fit, or narrow Narrow cavities cavities shall be filled by Insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures Installed in the building thermal envelope Recessed light fixtures Installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nininn an wilrinn Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication extedorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be J sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids bAl&een�reppgpkl�r coverolates and walli; or calil' s a. In addition, Inspection of log walls shall bean accordance with the provisions of ICC-400. 4/20/2020 2:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1720 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 c) Area 7c. 155.4 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and Insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRecO/o g) Other 10B7. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. 19.0 d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed b sed on installed code compliant features. Builder Signature: Date: \�\ Address of New Home: WYNNE DEV.°A\ Ar.Q,S4Wal-e-1\ City/FL Zip: FT. PIERCE. FL _?�-41 1 ia� S'r 4/20/2020 2:55:34 PM EnergyGauge® USA 6.0:04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1