HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNETHEMANOR IMPACT
'
Builder Name: WYNNE BUILDING CORP.
Street: THE MANOR 71 5 ` '
V ��,��
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CORP. �P \C-0,
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing. New (From Plans)
9. Wall Types(1654.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1374.20 ft'
b. Frame - Wood, Adjacent
R=11.0 280.00 ft'
3. Number of units, if multiple family 1
c. NIA
R= ft'
. 4. Number of Bedrooms 2
d. N/A
R= ft'
5. Is this a worst case? Yes
10. Ceiling Types. (1754.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1724.00 ft'
6. Conditioned floor area above grade (ft� 1724
b. Knee Wall (Vented)
R=19.0 30.00 ft'
Conditioned floor area below grade (ft5 0
c. NIA
R= ft'
11. Ducts
R ft'
7. Windows(153.4 sqft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 150
a. U-Factor: Sgl, U=1:04 113.35 ft'
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1.11 40.00 112
2. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=027
a. Central Unit
34.8 SEER:15.00
c. 'U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor. N/A ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.010 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1723.5 sqft.) Insulation Area
a: Electric
Cap:.50 gallons
a. Slab -On -Grade Edge Insulation R-0.0 1723:50 ftb.
Conservation features
EF:0.950
It. N/A R= ft'
None
c. NIA 'R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.089 Total Proposed Modified Loads: 53.45
PASS
Total Baseline Loads: 54.12
1 hereby certify that the plans and specifications covered by
Review of the plans and
O� 5
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
indicates
p
#. .D
calculation compliance
with the Florida Energy Code.
f. rr;,n, p
PREPARED BY:
Before construction is completed
r�
DATE: 1-9-20
this building will be inspected for
compliance with Section 553.908
=�-
r
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
,
with the Florida Energy Code.�+'p�""
OWNER/ NT
BUILDING OFFICIAL:
DATE: 0t
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402A.1.2).
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
1/8/2020 4:31- PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Colso. @ottware Page 1 of 6
FORM R405-2017 INPUT SUMMAKY.GHEGKLIST KEPUKI
PROJECT
Title: WYNNETHEMANOR
IMPA Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1724
Lot#
Owner Name: WYNNE BUILDING CORP. Total Stories: 1
Block/Subd'Msion:
# of Units: 1
Worst.Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING CORP. Rotate Angle: 270
l
Street:
THE MANOR 71
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State;
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/EKIsting: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site 97.5 W
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1724 14774.8
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 GREAT ROOM
546 5350.8 No
0
1
Yes
Yes
Yes
2 MASTER BEDROO
354 2832 No
2
1
1
Yes
Yes
Yes
3 WIC
77 616 No
0
1
No
Yes
Yes
4 CLST.
35 280 No
0
1
No
Yes
Yes
5 M BATH
54 432 No
0
1
Yes
Yes
Yes
6 KITCHEN
180 1440 Yes
0
1
Yes
Yes
Yes
7 JUNIOR M. BED
198 1584 No
0
1
1
Yes
Yes
Yes
8 BATH
50 400 No
0
1
No
Yes
Yes
9 POWDER
35. 280 No
0
1
Yes
Yes
Yes
10 NOOK
42 336 No
0
1
Yes
Yes
Yes
11 LAUNDRY
49 392 No
0
1
Yes
Yes
Yes
12 ENTRY
104 832 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
GREAT ROOM 47 ft 0
546 ft2
0 1
0
2Siab-On-Grade Edge Insulatio
MASTER BEDRO 46 ft 0
354 ft2
-_
0 1
0
3 Slab-On-Grade,Edge Insulatio
WIC 1 ft 0
77 ft2
____
0 1
0
48Iab-On-Grade Edge Insulatio
CLST. 1 ft 0
35 ft2
._
0 1
0
5 Slab -On -Grade Edge Insulatio
M BATH 9 ft 0
54 ft2
_
0 1
0
1/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT.
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
6SIab-On-Grade Edge Insulalio
KITCHEN lift
0
180 ft2
0 1 0
7.8Iab-On-Grade Edge lnsulatio
JUNIOR. M. BED 14 ft
0
198 112
_
0 1 0
8SIab-On-Grade Edge Insulalio
BATH 1 ft
0
50 1112
0 1 0
9 Slab -On -Grade Edge lnsulatio
POWDER 5ft
0
35 ft2
0 1 0
`10SIab-On-Grade.Edge lnsulatio
NOOK 6 It
0
.42 ft2
0 1. 0
11Slab-On-Grade Edge lnsulatio
LAUNDRY 17 ft
0
49 ft2
____
0 1 0
12SIab-On-Grade Edge Insulalio
ENTRY 5.9 ft.
0
103.5 ft?
0 1 0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emift
Emitt Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 - Hip Metal 1817 ft2'
0 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type
Ventilation Vent Ratio (1 in)
Area
FIBS
IRCC
1 Full attic
Vented
300
- .1724ft2
N.
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
GREAT ROOM
30
Blown
546 ft'
0.1
Wood
_
2 Under Attic (Vented)
MASTER BEDRO
- 30
Blown
354 112
0.1
Wood
_
3 Under Attic (Vented)
WIC
30
Blown
77 ft'
0.1
Wood
4 Under Attic (Vented)
CLST.
30
Blown
35 ft2
0.1
Wood
_
5 Under Attic (Vented)
M BATH
30
Blown
54 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
180 ft2
0.1
Wood
_
7 Under Attic (Vented)
JUNIOR M.BED
30
Blown
198ft2
0.1
Wood
_
8 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood.
9 Under Attic (Vented)'
POWDER
30
Blown
,35112
0.1
Wood
_
10 Under Attic (Vented)
NOOK
30
Blown
42ft2
0.1
- Wood
_
11 Under Attic(Vented)
LAUNDRY
30
Blown
49 ft2
0.1
Wood
_
12 Under Attic (Vented)
ENTRY
30
Blown
104 ft
0.1
Wood
13 Knee Wall (Vented)
GREAT ROOM
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Space Cavity Width
`Height
Sheathing' Framing Solar Below
0
_ 1
SW=>SE Exterior Concrete Block
= Int Ins(HREAT ROO 4.1 26
0 9
10
255.7 ft2
0
0 0.3
0
_ 2
NW=>S Exterior Concrete Block-
Int InsOREAT ROO 4.1 21
0 9
10
206.5 ft2.
0
0 0.3
0
3,
NE=>NW Exterior Concrete Block-
Int InsfilASTER BE 4.1 25
,0 8
, 0
200.0 ft'
0
0 0.3
0
1/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software. Page 3 of 6
FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar Below
Space
-4 SW=>SE Exterior
Concrete Block- Int Ins0JASTER BE
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
_ 5 NW=>S Exterior
Concrete Block- Int Ins61ASTER BE
4.1 13
0
8 0
104.0 ft2
0
0
0.3
0
-6 NE=>NW Exterior
Concrete Block - Int Insul M BATH
4.1 9
0
8 0
72.0 ft2
0
0
0.3
0
-7 SW=>SE Exterior
Concrete Block - Int lnsulKITCHEN
4.1 11..
0
8 0
88.0 ft2
0
0
0.3
0
-8 NE=>NW Exterior
Concrete Block - Int InsdUNIOR M. B
4.1 14
0
8 0
112.0 ft?
0
0
6.3
0
-9 SW=>SE Exterior
Concrete Block - Int InsuIPOWDER
4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
_ 10 SW=>SE Extedor
Concrete Block- Int Insul NOOK
4.1 6
0
8 0
48.0 ft2
0
0 t
0.3
0
_ 11 NE=>NW Exterior
Concrete Block - Int InsuLAUNDRY
4.1 3
0
8 0
24.0 ft2
0
0
0.3
0
_ 12 SE=>NE Exterior
Concrete Block- Int InsuLAUNDRY
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
13 SW=>SE Exterior
Concrete Block- Int InsuLAUNDRY
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
_ 14 SE=>NE Exterior
Concrete Block - Int Insul ENTRY
4.1 6
0
8 0
48.0 ft'
0
0
0.3
0
15 N=>W Garage
Frame - Wood ENTRY
11 35
8
280.0 ft2
0.23
0.3
0
DOORS
# Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 SE=>NE Insulated ENTRY
None
.32
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation _> changed to Worst Case.
_ / Wall
Overhang
V # Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 SW=>SE 1
Metal Low-E Single Yes
1.04 0.29
N
46.4 ft2
1 ft 0 in
1 ft 5 in
None
None
_ 2 NW=>SW 2
Metal Low-E Single Yes
1.11 0.27
N
40.01N
8 It 0 in
1 ft 5 in
None
None
_ 3 NW=>SW 5
Metal Low-E Single Yes
1.04 0.29
N
32.4 112
1 It 0 in
1 ft 5 in
None
None
_ 4 NE=>NW 6
Metal Low-E Single Yes
1.04 0.29
N
6.9 it'
1 ft 0In
1 ft 5 in
None
None
5 NE=>NW 8
Metal Low-E Single Yes
1.04 0.29
N
16.2 tl2
1 ft 0 In
1 ft 5 in
None
None
_ 6 SW=>SE 9
Metal Low-E Single Yes
1.04 0.29
N
6.9 112
1 It 0 in
1 ft 51n
None
None
7 SE=>NE 12
Metal Low-E Single Yes
1.04 0.29
N
4.7 112'
7 ft -0 in
1 ft 51n
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 440 ft2 440 ft2
35 ft
8 it
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000272 1231.2 67.59
127.12
.097
5
1/8/2020 4:31 PM EnergyGauge®USA 6.0.02(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# _ System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
None
Singl HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unitt
Split
Singl SEER: 15 34.8 kBtu/hr 1044 cfm 0.85
1
sys#1
HOT WATER SYSTEM
# System Type SubTpe
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
-
Collector Storage
Cart # Company Name
System Model # Collector
Model
# Area Volume
FEF
None None
ft'
DUCTS
--- Supply --
--- Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic 6 150 ft'
Attic
45 ft' Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programabl(e Thermostat: Y
Ceiling Fans:
r[
Heating [X] Jan Feb Mar
Apr
MDec
[X]
rj JMay un [ ]Jul
[X1
[ ]Aug
]
Ex] Sep
[
rD0'
rOC,I
Venting [[ 1] Jan [[[[ ]]]] Feb IX Mar
L l lxl
[
ay Jun t) Jul
t 1 Aug
[ ] Sep
�]]J
lXJ
lXJ Oct [X]
Nov
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9 10
11
12.
Cooling (WD) AM 78
78 78
'78 78 78
78
78
80 80
80
80
PM 80
80 78
78 78 78
78
78
78 78
78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
78 78
78
78
PM 78
78 78
78 78 78
78
78
78 78
78
78
Heating (WD)
68
68 68
PM
68 68 1 68
68
68
68 68
66
66
Heating (WEH) AM 66
66 66
66 66 68
68
68
68 68
68
68
- PM 68
68 68
68 68 68
68
68
68 68
66
-66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft'
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft.
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
ft
0.3
BATH
Default(8 lbs/sq.ft,
ft'
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft..
ft
0.3
LAUNDRY
1/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6thEdition (2017) Compliant Software Page 5 of 6
1/8/2020 4:31 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC M Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE MANOR IMPACT _ Builder Name: WYNNE BUILDING CORP.
Street: THE MANOR 71 Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CORP. Jurisdiction:
_
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
'A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed..
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
/soffit
The Insulation in an dropped ceiling/soffit
y pp 9
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shallbesealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed,
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per Inch minimum.
Exterior thermal envelope. insulation for framed
waits shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall Include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be Installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity Insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous Insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, Insulation
a Class i vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures Installed in the building
shall be sealed to the drywall.
thermal envelope shallbe air tight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind niping and wring
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs,
be Insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between Le-sDrinkler-cover plates and Wils or ceilings.
a. in addillon, inspection of logwallsshall be In accomance with the provisions or Il;l;-40u.
1/8/2020 4:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL(EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy
Performance Index, -the
more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & Insulation level
1.a),
Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AMU location
Attic
3. No..of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
1724
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient(SHGC)
7b.
0.285
14. Heating system: . Capacity
34.8
c)Area
7c.
153.4
a) Split system heat pump HSPF
b)Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factoc(weighted average)
8a.
NA
d) Gas fumace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
8.50
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised
(R-value)
9b.
15. Water heating system
c) Concrete, raised
(R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c). Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat"pump with tank EF_
2. Masonry.(Insulation R-value)
10A2.
.4.1
fl Heat recovery unit. HeafRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation' level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d)Radiant barrier installed
11d.
No
e) Multione heating credit:.
f) Programmable;thermostat
Yes
"Label required by Section R303.1.3 of the Florida Building Code, Energy. Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL .
display card will be completed based on installed code compliant features.
Builder Signature: Date: -
Address of New Home: THE MANOR 71 ��S\\ City/FL Zip: FT. PIERCE. FL �i
b'Qcl�
1/8/2020 4:36:22 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC-6lh.Edition (2017) Compliant Software Page 1 of 1