Loading...
HomeMy WebLinkAboutProduct Approval; Metal Roofingv I 1 EVALUATION REPORT;UF' 1 METAL. SALES MANUFACTURING CORPORATION GA..I"GE II�ANEPI`:' I - I � i 6C�IWECJ"� � _1 .; I FLORIDA,BUILDING CODE 6TH EDITION (2Q17) JUN 2 9 20'10' FLORIDA,PRODUCT APPROVAL permitting �;FL '1T5605-R3 ; ST. Lucie County, ROOFING. METAL ROOFING I I I Prepared For l "I MetalcSales•ManufacturmgCb . oration i 545 South 3"dStreet, Sorter 00)II Louisville, KYAI Telephone::1502).;855-430 � ! Fax: (5122) 8554200: I „ I I I i i I "i Prepa' red.By:; f Bala Sockalingam, Ph.IY., P1E. I' 4 Florida.P.rofessio, al.Engineer',#02240 121,6N Lansing Ave.,;SditefC.1. ; Tulsa,jOK 74106 'Telephone:, k(9I8) 492 5991; i Py Liln „.q I ,0 � This report consists of i 4 ., Evaluation Report (3 Pages inclu(�ng cover),; I�'�� InstallattonDetails (1.P,age) ��`,IIII�aOCI�ti,,��� Load Span, Table (f ,Pagel' I .` REVIEWED FOR CO®Ell COMPLIANCE' ' Report-f o. C2181-5, ST. LUCIE COUNTY Date.,9.8.2017' ;I BOCC II Ii j I I I I � I ZL iN0 62240 p r0 STATE OF � � I 1 I .I I i! it Manufacturer: li Product Name: ;I Panel Description: Materials-, Deck Description: Deck Attachment: (Minimum , Underlayment: Slope: Design Uplift Pressure: (Factor oflSafety = 2) Fastener Pattern: , At panel seam it li Sidelap Adhesive: :I Test Standards: I I Code Compliance: Product'Limitations: Metal Sales Manufacturing Image II I, Max. 16" wide coverage with 1" hig it Min. 26 ga., 50 ksi'steel. Galyanis Galvalume coated steel (ASTM A7S II Min. 19/32" plywood or min. '/a; tt for new and existing constructions. 2017. I 8d x 2.5" long ring shank nails ,or #7 in the field and edges, Designed as I Minimum underlayment as per FBC 1/2:12 or greater in,Iaccordance v Requires applied lap isealant for, roof 84.25 psf @ fastener (spacing of 24'1 102.7 psf @ fastener'spacing of 6" c 139.1 psf @ fastener spacing of 6 panel sidelap I� 11 #10-12 pancake head! screws along sufficient length to pepetrate throng] Schnee -Morehead S*7108 Perinath Roof assembly tested in accordai Requirementsfor Metal Roofing Sy: I The product described herein has di 2017 Section 1507.41 Design wind loads shall be deternu: with FBC 2017 Section 1609 or f design. The maximum fastener sl exceeded: The design pressure for computed- using rational analysis p Engineer or biased on Metal Sales report is not applicable in High N current NOA for useIof Us product ,' FL 1'1560.5-R3 i C2181-5 1 9.8.2017 Page 2 of 3 .on I I I I i r ribs A coated, steel (ASTM A653) or >-) or painted steel (ASTM A755). I I 1 [ck wood plank (min SG of 0.42) designed a an di,installed as per FBC I x 2" long wood screws @ 6" o.c. ;r FBC 2017.1 2017 Sectiowl507.4.5.1 ; i ith ,FBC, 2017 Section ;1507.4.2. slopes less jth'an 3:12. i C. o.c. with13/8" bead adhesive in panel seam. :Fastener shall be of the deck a,minimum of /4". me adhesive ce ;witW TAS 125-03 �Standazd monstrated' compliance with FBC ,ed for each project in accordance SCE 7-10 Iusmg allowable stress acing listed ('herein shall not be reduced' fastener spacing may be epared by:a;Florida Professional load span table. This evaluation -locity Hurricane Zone. Refer to in High, Velocity Hurricane Zone. FL 1,1560.5-R3 r I C2181-5 ! 9.8.2017 Page 3 of 3 Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Sectionn 1505 and, current approved roofing materials directory or ASTM �108/UL790; re I ort from an accredited' laboratory for fire ratings of Usl'product. t I� 3 Supporting Documents: TAS 125 Test'Reports "I Farabaugh Engineering and Testing C. Project No. T241-07, Reporting Date 7/23/07 I Hurricane Test Laboiatory, LLC ' ! HTL Report #t 0103-10714-09, Repo ing Date 9/1/09 + I II I I • ' ' I I I I i•' I • I I I� i I� • it � I j I � I 1 I I II I i i l a ROOF AN SEE DETAIL 1 - - PEL -- - -- MAX. 16', PANEL FASTENER SPACING PER ALLOWABLE PRESSURE TABLE. \ / UNOERLAYMENT SHALL BE INSTALLED `PLYWOOD AS PER MANUFACTURER'S INSTALLATION Bd x 2.5E LONG RING SHANK NAIL 19/32- THICK (MIN.) GUIDELINES OR #8 x 2' LONG WOOD SCREWS WOOD RARER/JOIST/ SPACED ® 6' O.C. IN THE MELD & MAX. 24° O.C. AT PLYWOOD EDGES FASTENING PATTERN 1 d. SEE DETAIL 2 -ADHESIVE IN THE MAX, 16• PANEL FASTENER u N ROOF PANEL �� PANEL SIDELAP SPACING PER ALLOWABLE PRESSURE TABLE. z Co - K ypC) _ IL InY I ' sMTm - UNDERLAYMENT SHALL BE INSTALLED - PLYVlOOD33 Bd x 2.5E LONG RING SWWK NAIL 19/32' THICK (MIN.) AS PER MANUFACTURER'S INSTALLATION $ n� Gr ORE x 2' LONG WOOD SCREWS 0 zq`—=D MST GUIDELINES MIN. 2X_ WOOD RAFTER/JOIST/ SPACED 06° O.C. IN THE FIELD & oo_ - - — - - = TRUSS.AT-MAX.-24'-O.C. _ - AT-PIYWOOD-EDGES— N FASTENING PATTERN 2 t TYPICAL PANEL INSTALLATION X—SECTION 2 _ u - MIN 26 GA PANEL- - - - = - - - _ _ - - _ _ -- - - - - - _ #10-12 X 1° LONG - _ _ - - - _ _ -- - -- - _ -- - - - - - _ a C a - —PANCAKE-SCREWS - DETAIL 1 ar MAx. 6 o.c. Z - - - - - - - - -- _ o oFa 6DERLA7MENT PLYWOOD __19/32' THICK (MIN.). SIDELAP ADHESIVE NOM. 3/8' BEAD MIN 26 GA. PANEL P10-12 X 1' LONG - - GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDMCE WGH THE PANCAKE SCREWS SIDEIAP ADHESIVE FLORIDA BUILDING CODE (MC), DETAIL 2 -- _ — A_T MAX. 6' O.C. _ _ _ _- _ LOCATION - - - ?. ROOF PANELS SHNL BE MIN. 26 CA (L 0.016)�. MA%.,,EFFECirvE.COVFAING_ WIDTH OF PANEL - 16'. - - - - -- -- ---- - - 3, THE ROOF PANELS SN BE NSTAILED OVER SHEATHING & SIHUCNRE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE OETERMINED FOR EACH PROJECT. THIS W PMEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ME GREATER THM THE &LOWMI-E WIND LOADS SPECIFIED ON MI5 DRAWING. MUST IN WITH MIS DRAWING & E FLORIDA UNDERLAYMEM PLYWOOD S DIFFERENCERDANCE BUILDINGENERS C OE F ABE OCCUR BETWEEN THE MINIMUM 19/32' THICK (MIN.) REQUIREMENTS OF THIS DRAWING & THE CODE THE CODE SHAH CONTROL 2181-5 PAGf NQ. 6. RAFTFAS/JOISTS/RRU556 MUST BE DESIGNED TO WRHSTAND WIND LOADS AS REQUIRED FOR EACH MPMCKRON AND ME ME RESPONSISILRY OF OTHERS. 1 OF 1 I u , MEfAjl SALES MANUFACTURING C ORYORATTON I Image U, Uplift Loads' (Min. 26 ga.) Description Fastener Spacing along Panel Length (in) Allowable Uplift 1 Load (psfl Coverage width: 16" Panel Fastener: #10-112 pancake head screws I „ 6 1.102.7 1 8 100.7 1 110 98.6 12 I. 96.6 i 14 94.5 116 92.5 18 90.4 1 20 88.4 22 86.3 1' 24 84.3 With Sidelap Sealant !� 6 1139.1, Notes:'! 1. The bold numbers indicate design loads calculated from test data w: 2. Pane)s must be installed as per Evaluation Report{F , 115603. and l I� 3. 'Threi or more spans condition. I I II I I I it E/yS�.G9;y. Nol'62240 TAT p � 1 : O� STATE O 1216 N Linsin Ave., Suite C N, 4 L E �� Tulsa, Ok 7410LI 918 492 5992 I Ili � I ifety factor of 2. ISalescu1 installationprocedure. I f a , r , 1 I ! lq I I I II 1 I I I I I I I I� ' I g 1 Bala Sockalingam, Ph.D., P.E. P Fl,62240 I I