HomeMy WebLinkAboutFL16039_R15 Duro Last NOA[5]a CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6TH EDITION (2017) Manufacturer: Duro-Last Roofing, Inc. Issued February 20, 2019 525 Morley Drive Saginaw, MI 48601 989-737-3043 www.duro-last.com Manufacturing Plants: Saginaw, MI Jackson, MS Sigourney, IA Quality Assurance: UL LLC (QUA1743) SCOPE Category: Roofing Subcategory: Single Ply Roof System Code Sections: 1504.3.1, 1504.6, 1507.13.2, 1515.1.1, 1515.1.4, 1523.1.1, 1523.6.2 Properties: Wind Resistance, Physical Properties PRODUCT DESCRIPTION Products Specification Description Duro-Last Designer Series Membrane ASTM D 4434 Nominal 50-mil thick single-ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim. The membranes are available as Rock-Ply® and Shingle-Ply® prefabricated sections or roll goods. Duro-Last Membrane ASTM D 4434 Nominal 40-mil (DL40), 50-mil (DL50), or 60-mil (DL60) thick single-ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim. The membranes are available as prefabricated sections or roll goods. Duro-Fleece Membrane ASTM D 4434 Nominal 50-mil (DF50), 60-mil (DF60), or 80-mil (DF80) thick single-ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim and backed with fleece. Duro-Tuff membranes are available in the following colors: White for all thickness, and Blue, Copper, Charcoal, Green, Light Gray, Patina, and Light Tan for DF50 and DF60 only The membranes are available as roll goods. Duro-Fleece Plus Membrane ASTM D 4434 Nominal 50-mil (DFP50) or 60-mil (DFP60) thick single-ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim and backed with fleece. The membranes are available as roll goods. Duro-Tuff Membrane ASTM D 4434 Nominal 50-mil (DT50), 60-mil (DT60), or 80-mil (DT80) thick single-ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim. Duro-Tuff membranes are available in the following colors: White for all thickness, and Blue, Copper, Charcoal, Green, Light Gray, Patina, and Light Tan for DT50 and DT60 only. The membranes are available as roll goods. A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes REFERENCES Entity Report No. Standard Architectural Testing, Inc. (TST1558) B8983.01-106-18 TAS 117(A) (1995) Architectural Testing, Inc. (TST1558) C0713.01-19.18 TAS 114(J) (19951) Certified Testing Laboratories (TST1577) CTLA 107R TAS 114 (J)(1995) Certified Testing Laboratories (TST1577) CTLA 107R-A TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-013-02-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-014-02-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-018-02-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-021-02-01 Rev 13 ASTM D 1761 (2006); TAS 117(A) & (B) (1995); FM 4474 (2011); TAS 114(D) & (H) (1995) PRI Construction Materials Technologies (TST5878) DLRI-041-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-029-02-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-030-02-01 FM 4474(B) (2011); TAS 114(D) (1995) PRI Construction Materials Technologies (TST5878) DLRI-041-02-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-045-02-01 FM 4474(B) (2011); TAS 114(D) (1995) PRI Construction Materials Technologies (TST5878) DLRI-045-02-02 FM 4474(B) (2011); TAS 114(D) (1995) PRI Construction Materials Technologies (TST5878) DLRI-046-02-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-047-02-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-053-02-01 ASTM D 4434 (2012); ASTM G 155 (2005a) PRI Construction Materials Technologies (TST5878) DLRI-055-02-01 ASTM D 4434 (2012); ASTM G 155 (2005a) PRI Construction Materials Technologies (TST5878) DLRI-058-02-01 FM 4474(B) (2011); TAS 114(D) (1995) PRI Construction Materials Technologies (TST5878) DLRI-063-02-01 FM 4474(B) (2011); TAS 114(D) (1995) PRI Construction Materials Technologies (TST5878) DLRI-068-02-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-073-02-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-073-02-02 FM 4474(B) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-077-02-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-077-02-02 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-079-02-01.1 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-082-02-01 FM 4474(D) (2011); TAS 114(J) (1995) PRI Construction Materials Technologies (TST5878) DLRI-086-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-086-02-02 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-096-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-096-02-02 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-099-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-100-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-113-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-114-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-115-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-119-02-01 TAS 114(D) (1995) PRI Construction Materials Technologies (TST5878) DLRI-119-02-02 TAS 114(D) (1995) PRI Construction Materials Technologies (TST5878) DLRI-120-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-124-02-02 ASTM D 4434 (2012) PRI Construction Materials Technologies (TST5878) DLRI-126-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-126-02-02 TAS 114(D) (1995) PRI Construction Materials Technologies (TST5878) DLRI-126-02-03 TAS 114(D) (1995) PRI Construction Materials Technologies (TST5878) DLRI-128-02-01 TAS 117(B) (1995) PRI Construction Materials Technologies (TST5878) DLRI-130-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) DLRI-130-02-02 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) NGC-034-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) NGC-035-02-01 FM 4474(D) (2011); TAS 114(J) (1995); A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes Entity Report No. Standard UL 1897 (2012) PRI Construction Materials Technologies (TST5878) NGC-038-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) NGC-041-02-01 FM 4474(D) (2011); TAS 114(J) (1995); UL 1897 (2012) Trinity ERD (TST6049) 02733.01.05-1 FM 4470 (2012); TAS 114(J) (1995) Trinity ERD (TST6049) 02744.05.06 FM 4470 (2012); TAS 114(J) (1995) Trinity ERD (TST6049) D6760.08.07 FM 4470 (2012); TAS 114(J) (1995) Trinity ERD (TST6049) 02750.02.08 ASTM D 4434 (2012) Trinity ERD (TST6049) 02762.03.05 TAS 114(D, H & J) (1995) Trinity ERD (TST6049) D35210.08.11-R3 ASTM D 4434 (2012) Trinity ERD (TST6049) D40260.03.13-1 TAS 110 (2000) Trinity ERD (TST6049) D40280.03.13 TAS 110 (2000) Trinity ERD (TST6049) D42320.08.12 FM 4474(D) (2012); TAS 114(J) (2011) Trinity ERD (TST6049) D44450.05.13-2 ASTM D 4434 (2012) FM Approvals (TST1867) J.I. 2M4A8 .AM FM 4470 (2012) FM Approvals (TST1867) J.I. 3Y5A6 .AM FM 4470 (2012) FM Approvals (TST1867) J.I. 1X2A7 .AM FM 4470 (2012) FM Approvals (TST1867) 4D6A4.AM FM 4470 (2012) FM Approvals (TST1867) 3005604 FM 4470 (2012) FM Approvals (TST1867) 3006989 FM 4470 (2012) FM Approvals (TST1867) 3008342 FM 4470 (2012) FM Approvals (TST1867) 3010289 FM 4470 (2012) FM Approvals (TST1867) 3010987 FM 4470 (2012) FM Approvals (TST1867) 3014929 FM 4470 (2012) FM Approvals (TST1867) 3015816 FM 4470 (2012) FM Approvals (TST1867) 3023458 FM 4450 (1989) FM Approvals (TST1867) 3026128 FM 4470 (2012) FM Approvals (TST1867) 3026508 FM 4450 (2012) FM Approvals (TST1867) 3032172 FM 4470 (2012) FM Approvals (TST1867) 3033314 FM 4470 (2012) FM Approvals (TST1867) 3040346 FM 4470 (2012) FM Approvals (TST1867) 3044466 FM 4470 (2012) FM Approvals (TST1867) 3040741 FM 4470 (2012) FM Approvals (TST1867) 3050118 FM 4470 (2012) FM Approvals (TST1867) 3054028 FM 4470 (2012) FM Approvals (TST1867) 3063970 FM 4470 (2012) 1Standard test method has been found equivalent to FM 4474 (2004) referenced by the 2017 FBC. A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3. Foam plastic insulation shall be installed in accordance with the FBC Section 2603.4. 4. In the HVHZ, fastener spacing for insulation attachment is determined using a Minimum Characteristic Force (F’) of 275 lbf as demonstrated via testing to TAS 105. If the field tested fastener value is below 275 lbf, then insulation attachment shall not be acceptable. 5. In the HVHZ, fastener spacing for base sheets or membrane attachment shall meet the minimum fastener resistance value and the MDP for the specified roof system. It is permissible for a qualified professional to submit a revised fastener spacing utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137, when the fastener resistance is found less than required. 6. In the HVHZ, if mechanical attachment through the lightweight insulating concrete to the structural deck is proposed, a field fastener withdrawal test shall be conducted in compliance with TAS 105 to determine equivalent or increased attachment densities. Revised fastener densities shall b e submitted utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137. 7. For assemblies containing mechanical attachment, the allowable uplift pressure for the selected roof system shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16. For perimeter and corner roof zones 2 and 3, the attachment density may be increased by a qualified design professional, as necessary, to meet the d esign pressure requirements in these areas. In the HVHZ, calculations shall be conducted in compliance with RAS 117 and/or RAS 137. 8. Reroofing applications shall be examined in accordance with FBC Section 151 1 outside of the HVHZ and FBC Section 1521 within the HVHZ. For mechanically fastened roof systems, a field withdrawal resistance test (TAS 105 in the HVHZ; ANSI/SPRI FX-1 or TAS 105 in the non-HVHZ) shall be conducted by a qualified professional to ensure the fastener meets the minimum design load req uirements of the roof system. For adhered roof systems, a field uplift resistance test (TAS 124 in the HVHZ; ASTM E 907, FM LPDS 1 -52, ANSI/SPRI IA-1, or TAS 124 in the non-HVHZ) shall be conducted to confirm conformance of the existing to the minimum design loads. 9. For assemblies containing fully adhered or ribbon adhered attachment, or where extrapolation of the roof system is not permitted, the MDP for the selected roof system shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16 without augmentation. 10. Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 11. The minimum roof slope shall be 1/4:12 for new construction. 12. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. 13. Fasteners applied in rows may impart concentrated loads to structural components of the building. Designers should consider the fastener spacing of the roof system in relation to the spacing of structural supports when selecting a roof system. A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1)APPENDIX A – Installation (7 pages) 2)APPENDIX B – Nomenclature and Approved Assemblies (33 pages) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 1 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX A INSTALLATION Note - Refer to the APPROVED ASSEMBLIES section of this report for specific installation details of a selected roof system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail Fasteners & Plates Dow ENERFOAM™ Foam Sealant Dispensed using application gun for 2 full seconds into 7/16- inch pilot hole drilled to a depth of 2.5-inch; Fasteners installed within 20-40 seconds after dispensing Duro-Bond Plate 1302 3-inch induction welding plate for PVC membranes; welds not permitted at lap seams Duro-Bond PVC IW Plate Duro-Last 3-inch Metal Plates 3-inch x 3-inch square; 0.024-inch thick Galvalume steel Duro-Last #14 Concrete Screw Min. 1.25-inch penetration into concrete Duro-Last Cleat Plates Min. 2 3/8-inch diameter, 0.035-inch thick steel plate with cleats Duro-Last Duro-Coated Hex Head Screws Min. 1.25-inch penetration into concrete Duro-Last Fluted Concrete Nail Min. 1.25-inch penetration into concrete Duro-Last #14 HD Fastener #14 screw; Min. 1-inch penetration into No. 2 wood truss; Min. 3/4-inch penetration through the top rib of the steel deck or through wood deck Duro-Last #15 Extra Heavy Duty Drill Point Fastener #15 screw; Min. 3/4-inch penetration through the top rib of the steel deck or through wood deck Duro-Last Auger Fastener Min. 2-inch penetration into substrate Duro-Last Auger Plates Min. 2-inch diameter steel plate Duro-Last Poly-Plate Min. 2-inch diameter, 0.335-inch thick glass-filed polycarbonate plate with cleats OMG XHD Fastener #15 screw; Min. 3/4-inch penetration through the top rib of the steel deck or through wood deck TRUFAST FM-90 Base Sheet Fastener 2.7-inch steel plate with dual grip shanks; Min. 1.7-inch penetration into substrate; TRUFAST Twin Loc Coiled Batten Bar 100 ft. long, 1-inch wide, 0.040-inch thick Galvulume coil with pre-punched holes 3-inch o.c. TRUFAST DP #12 Fastener #12 screw; Min. 3/4-inch penetration through the top rib of the steel deck TRUFAST 3” Metal Insulation Plate Min. 3-inch diameter steel plate TRUFAST Twin Loc-Nail Assembled Fastener 2.7-inch steel disk with locking staple; Min. 1.8-inch penetration into substrate TRUFAST Twin Loc-Nail Batten Fastener Locking staple; Min. 1.8-inch penetration into substrate; for use with TRUFAST Twin Loc Coiled Batten Bar TRUFAST VERSA-FAST Fastener Min. 2-inch embedment into LWIC or Gypsum decks TRUFAST VERSA-FAST Metal Plate 3-inch diameter; 0.017-inch thick Galvalume steel plate with one (1) center hole and eight (8) equally spaced perimeter holes for multiple fastening Insulation Continuus ReWall Closed Loop Roof Cover Board with coated fiberglass facer Min 1/2-inch thick roof board with recycled plastic/cellulose core and coated fiberglass facer DEXcell FA Glass Mat Roof Board Min. 1/4-inch thick gypsum roof board with fiberglass facer DEXcell Cement Roof Board Min. 7/16-inch thick cement roof board with glass mesh A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 2 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX A Component Product Installation Detail Insulation (Cont’d) Duro-Fold Underlayment Board Min. 0.5-inch thick; Extruded polystyrene (XPS) with polypropylene facer; Adhered boards shall be a maximum 4-ft x 4-ft Duro-Guard EPS Min. 0.5-inch, min. 1.8 pcf EPS (HVHZ) or min. 1.5 pcf EPS (non-HVHZ); Adhered boards shall be a maximum 4-ft x 4-ft Duro-Guard EPS Fan Fold Min. 0.5-inch, min. 1.25 pcf EPS board with polymeric film facer (non-HVHZ only) Duro-Guard EPS Fiberglass Facer (FGF) Min. 0.5-inch, min. 1.8 pcf EPS (HVHZ) or min. 1.5 pcf EPS (non-HVHZ only) with fiberglass facer; Adhered boards shall be a maximum 4-ft x 4-ft Duro-Guard XPS Fan Fold Min. 0.5-inch thick; Extruded polystyrene (XPS) with polymeric facer; Adhered boards shall be a maximum 4-ft x 4-ft Duro-Last Duro-Guard ISO II-A Min. 0.5-inch thick; Min. 20 psi polyisocyanurate board with various facers; Adhered boards shall be a maximum 4-ft x 4-ft Duro-Last Duro-Guard ISO II-G Duro-Last Duro-Guard ISO II-H Duro-Last Duro-Guard ISO III-A Duro-Last Duro-Guard ISO III-G Duro-Last Duro-Guard ISO III-H Duro-Last Duro-Guard ISO IV-A Duro-Last Duro-Guard ISO Foil Duro-Last Duro-Guard ISO HD Composite Min. 2-inch thick composite polyisocyanurate board; Adhered boards shall be a maximum 4-ft x 4-ft Duro-Last Duro-Guard ISO HD-A Min. 0.5-inch thick; Min. 90 psi polyisocyanurate board with coated fiberglass facers; Adhered boards shall be a maximum 4-ft x 4-ft Duro-Last Duro-Guard ISO HD-G Duro-Last Duro-Guard ISO HD-H Georgia-Pacific DensDeck, Dens Deck Prime Min. 0.25-inch thick gypsum roof board with fiberglass facer; JM Invinsa Roof Board Min. 0.25-inch thick; Min. 150 psi polyisocyanurate with coated fiberglass facers; Adhered boards shall be a maximum 4-ft x 4- ft Insulfoam R-Tech Fan Fold Min. 0.5-inch ASTM C 578 Type IX (HVHZ) or Type II (non- HVHZ) Expanded Polystyrene with polymeric facers; Adhered boards shall be a maximum 4 ft x 4 ft USG SECUROCK Gypsum-Fiber Roof Board Min. 0.25-inch thick gypsum roof board with fiber reinforcement; Insulation Adhesive Olybond Classic Applied in 3/4 to 1-inch wide ribbons Duro-Grip Board-Max Apply in 3-inch wide ribbons Duro-Grip CR-20 Adhesive Apply in 3/4 to 1-inch wide ribbons Duro-Grip Insta Stik Apply in 3/4 to 1-inch wide ribbons Duro-Grip OlyBond 500 Apply in 3/4 to 1-inch wide ribbons Duro-Grip Trufast Apply in 3/4 to 1-inch wide ribbons Duro-Grip WeatherTite One Step Apply in 1/2 to 3/4-inch wide ribbons Membrane Adhesive Duro-Fleece CR-20 Membrane Adhesive Fleeceback products only; Apply in spatter pattern at a rate of 8 lbs/100-ft2 A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 3 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX A Component Product Installation Detail Membrane Adhesive (Cont’d) Duro-Fleece Membrane Adhesive Fleeceback products only; Apply in 3/4-inch wide ribbons Duro-Last SB IV Adhesive Barebacked products only; Fully adhere at a combined rate 60- ft2/gal (Apply 120-ft2/gal to both membrane and substrate). Coverage will vary depending on porosity of substrate. Duro-Last WB II Adhesive Fleece backed membranes: Fully adhere at a rate of 100-ft2/gal to substrate only. Coverage will vary depending on porosity of substrate. Barebacked membranes: Fully adhere at a rate of 140-ft2/gal to substrate only. Coverage will vary depending on porosity of substrate. Single-Ply Membrane Duro-Last Membrane Min. 3-inch tab with min. 1.5-inch welded lap seam for adhered and induction welded systems; Side-laps shall be installed parallel to the direction of the wood trusses for mechanically attached systems over wood decks; Side-laps shall be installed perpendicular to the direction of the steel deck ribs for mechanically attached systems over steel deck; For in-lap attachment, the center of the plate shall be 1 1/4-inch from the tab edge. Duro-Fleece Plus Membrane Duro-Tuff Membrane Min. 4-inch lap for mechanically fastened systems and min. 3- inch lap for adhered systems with min. 1.5-inch welded lap seam; Side-laps shall be installed parallel to the direction of the wood trusses for mechanically attached systems over wood decks; Side-laps shall be installed perpendicular to the direction of the steel deck ribs for mechanically attached systems over steel deck. Duro-Fleece Membrane Thermal Barrier GAF Versashield Solo For mechanically fastened systems; Min. 4-inch end lap; Min. 2-inch side lap; Shall be laid perpendicular to the direction of membrane Vapor Barrier Duro-Last Vapor Barrier Self-adhered to substrate with optional ELASTOCOL STICK primer Edge Systems Duro-Last Fascia Bar Designed by others and installed in accordance with Duro- Last’s current, published installation instructions. Duro-Last Fascia Bar Cover Duro-Last Fascia Duro-Last Snap Coping Duro-Last 2-Piece Metal “T-Edge” Duro-Last Drip Edge Duro-Last 2-Piece Compression Edge Duro-Last Vinyl Coated Metal Duro-Last Gravel Stop Duro-Last Versaterm Edge Cellular Lightweight Concrete Celcore S-1 Deck is treated by applying a continuous film with a broom prior to placement of the Celcore lightweight concrete Celcore MF with HS Rheology Admixture Installed over min. 22 ga., 0.5% vented, B-Deck; Slurry coat min. 1/8-inch thick; 1-inch thick EPS board (1 lbs/ft3); Min. 2- inch thick top coat; Celcore PVA curing compound applied at rate of 300 ft2/gal Elastizell with Zell-Crete Fibers Slurry coat min. 1/4-inch thick; Min. 1-inch thick EPS board (1 lbs/ft3); Min. 2-inch top coat Cellular Lightweight Concrete A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 4 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX A Insulation/Cover Board Fastening Patterns Description Fastening Pattern 5 per 4 ft x 8 ft board (Max. 6.4ft2 contributory area per fastener) 6 per 4 ft x 8 ft board (Max. 6ft2 contributory area per fastener) 12 per 4 ft x 8 ft board (Max. 2.67ft2 contributory area per fastener) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 5 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX A Insulation/Cover Board Fastening Patterns Description Fastening Pattern 16 per 4 ft x 8 ft board (Max. 2.0ft2 contributory area per fastener) 18 per 4 ft x 8 ft board (Max. 1.78ft2 contributory area per fastener) 20 per 4 ft x 8 ft board (Max. 1.6ft2 contributory area per fastener) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 6 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX A Insulation/Cover Board Fastening Patterns Description Fastening Pattern 24 per 4 ft x 8 ft board (Max. 1.33ft2 contributory area per fastener) 32 per 4 ft x 8 ft board (Max. 1.0ft2 contributory area per fastener) VERSA-FAST Metal plate Fastening Pattern A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 7 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX A Induction Weld Patterns Description Fastening Array Repeated Using the Geometric Grid Shown Below 1 per 3.00-ft2 1 per 4.00-ft2 1 per 6.00-ft2 A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 1 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B NOMENCLATURE The following naming conventions are utilized to specify products in the APPROVED ASSEMBLIES section of this report. Refer to the nomenclature below when deciphering the allowable products for use in the selected roof system. Installation requirements shall be as noted in the APPROVED ASSEMBLIES and INSTALLATION section of this report. Name Definition Approved Insulation One or more layers or combinations of roofing insulation listed in this report or approved under rule 61G20-3, such as gypsum, perlite, polyisocyanurate, polystyrene, or wood fiberboard. Insulation shall be preliminarily secured unless otherwise noted. As Tested Information provided to the report user based on the as tested condition of the roof system CR-20 Duro-Fleece CR-20 Membrane Adhesive; For use with DF or DFP Deck Detail All decks shall be designed by others in accordance with FBC requirements. As Tested deck construction details are described as follows: Concrete Deck Min. f’c = 2,500 psi at 28 days CWF Deck Min. 2.5-inch thick Tectum I cementitious wood fiber panels Steel Deck Min. 22 ga (Fy = min.33 ksi) Wide Rib Deck (Type WR) conforming to ANSI/SDI-RD1.0 & FBC; 0.5% Vented for LWIC applications only. The following nomenclature is used to further describe the As Tested condition: F<#> Number <#> #12-24 HWH self-drilling screws or equivalent fastener at each flute used to secure the deck to the structural supports; Min. 1/4-inch penetration G<#> Min. Grade <#> of Steel Deck L<#> Max. span of <#> ft P Min. 5/8-inch diameter puddle welds at each flute used to secure the deck to the structural supports S<#> 1/4 ”-14 HWH x7/8” self-drilling screws or equivalent fastener secured <#>-inch o.c. along the panel side laps W 3/4-inch O.D. flat washer used with indicated fastener Wood Deck HVHZ: Min. 19/32-inch thick APA Span-Rated plywood or wood plank for new construction The following nomenclature is used to further describe the As Tested condition: T<#> Min. <#>-inch thickness of the plywood or wood plank L<#> Max. span of <#> inches 0.113-<#1>/<#2> 0.113-inch x 2-3/8-inch ring shank nails spaced <#1>-inch o.c. at all intermediate supports and spaced <#2> at the perimeter of each board 8d-<#1>/<#2> 8d ring shank nails spaced <#1>-inch o.c. at all intermediate supports and spaced <#2> at the perimeter of each board Hex-<#1>/<#2> 1/4-inch x 2-inch hex wood screws spaced <#1>-inch o.c. at all intermediate supports and spaced <#2> at the perimeter of each board DD Min. 1/4-inch thickness Georgia-Pacific DensDeck DDP Min. 1/4-inch thickness Georgia-Pacific DensDeck Prime DF One ply of any one of the following products: DF50, DF60, or DF80 membranes A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 2 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Name Definition DFP One ply of any one of the following products: DFP50 or DFP60 membranes DG-BM Duro-Grip Board-Max DG-CR Duro-Grip CR-20 DG-IS Duro-Grip Insta Stik DG-OB Duro-Grip OlyBond 500 DG-TF Duro-Grip Trufast DG-OS Duro-Grip WeatherTite One Step DL One ply of any one of the following products: DL40, DL50, or DL60 membranes DL Plates & #15 Fasteners Duro-Last 3” Metal Plates and Duro-Last #15 Extra Heavy Duty Drill Point Fastener for Steel Decks or Wood Decks DL Plates & Fasteners Duro-Last 3” Metal Plates and Duro-Last #14 HD Fastener for Steel Decks or Wood Decks or Duro-Last #14 Concrete Screws for Concrete Decks DT One ply of any one of the following products: DT50, DT60, or DT80 membranes DXF DEXcell FA Glass Mat Roof Board DXC DEXcell Cement Roof Board Duro-Bond Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate with Duro-Last #14 HD Fastener for Wood Decks or Steel Decks or Duro-Last #14 Concrete Screw for Concrete Decks Duro-Bond #15 Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate and Duro-Last #15 Extra Heavy Duty Drill Point Fastener for Steel Decks or Wood Decks Duro-Grip Ribbon adhered with any one of the following products: Duro-Grip Board-Max, Duro-Grip CR-20, Duro-Grip Insta Stik, Duro-Grip OlyBond 500, or Duro-Grip WeatherTite One Step Duro-Guard One or more layers of the following products: Duro-Guard EPS, Duro-Guard EPS FGF, Duro-Guard ISO II-A, Duro-Guard ISO II-G, Duro-Guard ISO II-H, Duro-Guard ISO III-A, Duro-Guard ISO III-H, Duro-Guard ISO IV-A, or Duro-Guard HD Composite Duro-Guard II One or more layers of the following products: Duro-Guard EPS, Duro-Guard ISO II-A, Duro-Guard ISO II-G, or Duro-Last Duro-Guard ISO II-H EPS Duro-Guard EPS FGF Duro-Guard EPS Fiberglass Facer (FGF) HD-A Duro-Guard ISO HD-A HD-G Duro-Guard ISO HD-G HD-H Duro-Guard ISO HD-H II-A Duro-Guard ISO II-A II-G Duro-Guard ISO II-G A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 3 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Name Definition II-H Duro-Guard ISO II-H III-A Duro-Guard ISO III-A III-G Duro-Guard ISO III-G III-H Duro-Guard ISO III-H IV-A Duro-Guard ISO IV-A LWIC Poured-in-place; Cellular Lightweight Concrete with encapsulated insulation board MCRF Minimum Characteristic Resistance Force as determined by TAS 105 for the named fastener in the selected assembly MDP Maximum Design Pressure Recover Where assemblies are used to recover an existing roof, the existing roof shall consist of only one layer of roofing, i.e. rec overing a previously recovered roof is not permitted. Recover roofing shall be conducted in compliance with FBC Section 151 1 outside of the HVHZ and FBC Section 1521 within the HVHZ. For mechanically fastened assemblies, the existing roof insulation thickness may be contributory in me eting the minimum insulation thickness requirements for a given roof system. SB IV Duro-Last SB IV Adhesive; For use with DL, or DT SR USG SECUROCK gypsum-fiber roof board, Min. 1/4-inch thickness WB II Duro-Last WB II Adhesive; For use with DF, DFP, DL, or DT, A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 4 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B APPROVED ASSEMBLIES The following notes shall be observed when using the roof system tables below. 1. MDPs were calculated using a 2:1 margin of safety per FBC Section 1504.9 and 1523.4. MDP shall exceed -45 psf for use in the HVHZ. 2. Refer to LIMITATIONS and NOMENCLATURE sections of this evaluation when using the table(s) below. Items italicized refer to specific nomenclature used in this report. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected roof system. 4. The on-center (o.c.) spacing given is the maximum allowable attachment spacing for the rated roof system. 5. As Tested information for roof deck construction is provided for information only. The addition of the As Tested deck information does not obviate the requirement for rational design of the roof deck and roof deck attachment in accordance with FBC requirements. 6. Duro-Last Vapor Barrier may be installed direct to deck prior to installing the roof assembly components for following assembly types: C -M-#, C-W-#, G- M-#, LC-M-#, LS-M-#, S-M-#, S-W -#, W -M-#, and W -W-#. Roof System Numbers and Definitions C-A-# Assemblies with All Layers Adhered over Concrete Deck (New or Existing) C-AM-# Assemblies with Adhered Membranes over Insulated Concrete Deck (New, Existing, or Recover) C-M-# Mechanically Fastened Assemblies over Concrete Deck (New, Existing, or Recover) C-W-# Induction Welded Assemblies over Concrete Deck (New, Exiting, or Recover) CW-A-# Assemblies with All Layers Adhered over CWF Deck (New or Existing) CW-M-# Mechanically Fastened Assemblies over CWF Deck (New, Existing, or Recover) G-A-# Assemblies with All Layers Adhered over Gypsum Deck (New or Existing) G-M-# Mechanically Fastened Assemblies over Poured Gypsum Deck (New or Existing) LC-A-# Lightweight Concrete Assemblies with All Layers Adhered over Concrete Deck (New or Existing) LC-M-# Mechanically Attached Lightweight Insulating Concrete Assemblies over Concrete Deck (New or Existing) LS-A-# Lightweight Concrete Assemblies with All Layers Adhered over Steel Deck (New or Existing) LS-M-# Mechanically Attached Lightweight Insulating Concrete Assemblies over Steel Deck (New or Existing) R-A-# Recover Assemblies with All Layers Adhered R-M-# Mechanically Fastened Recover Assemblies R-W-# Induction Welded Recover Assemblies S-A-# Assemblies with All Layers Adhered over Steel Deck (New or Existing) S-AM-# Assemblies with Adhered Assemblies over Steel Deck (New, Existing or Recover) S-M-# Mechanically Fastened Assemblies over Steel Deck (New, Existing, or Recover) S-W-# Induction Welded Assemblies over Steel Deck (New, Existing, or Recover) W-A-# Assemblies with All Layers Adhered over Wood Deck (New or Existing) W-M-# Mechanically Fastened Assemblies over Wood Deck (New or Existing, or Recover) W-W-# Induction Welded Assemblies over Wood Deck (New, Existing, and Recover) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 5 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with All Layers Adhered over Concrete Deck (New or Existing) System No. Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) C-A-1 Min. 0.5-inch Duro-Guard II Duro-Grip or DG-TF ribbon adhered 12-inch o.c. EPS FGF, II-A, II-G, II-H, III-A, III-H, IV-A, HD-A, HD-G, HG-H, DDP, or SR Duro-Grip or DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -60 (Lim. 9) C-A-2 Min. 1-inch III-H DG-TF ribbon adhered 12-inch o.c. OPTIONAL DDP, DXC, DXF, HD-A, HD-G, or SR DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -90 (Lim. 9) C-A-3 OPTIONAL Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. DXF or SR DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -97.5 (Lim. 9) C-A-4 - - - - DL SB IV -102.5 (Lim. 9) C-A-5 OPTIONAL Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. HD-H DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -112.5 (Lim. 9) C-A-6 Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. OPTIONAL DDP, HD-G, or DXC DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -120 (Lim. 9) C-A-7 OPTIONAL Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. HD-G DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -120 (Lim. 9) C-A-8 Min. 1-inch II-H DG-TF ribbon adhered 12-inch o.c. OPTIONAL DDP or DXC DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -127.5 (Lim. 9) C-A-9 DL WB II -127.5 (Lim. 9) C-A-10 Min. 1-inch EPS, II-A, II-G, II-H Duro-Grip ribbon adhered 12-inch o.c. OPTIONAL (except EPS) DXC or DXF Duro-Grip ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -135 (Lim. 9) C-A-11 Min. 0.5-inch EPS FGF, II-A, or II-H DG-IS ribbon adhered 12-inch o.c. - - DL, DT, DF or DFP WB II, SB IV, or CR-20 -135 (Lim. 9 ) C-A-12 Min. 0.5-inch II-G DG-IS ribbon adhered 12-inch o.c. - - DL, DT, DF or DFP WB II, SB IV, or CR-20 -142.5 (Lim. 9) C-A-13 Min. 0.5-inch EPS FGF, II-A, or II-H DG-OS ribbon adhered 12-inch o.c. - - DL, DT, DF or DFP WB II, SB IV, or CR-20 -150 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 6 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with All Layers Adhered over Concrete Deck (New or Existing) System No. Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) C-A-14 OPTIONAL Min. 1-inch EPS DG-TF ribbon adhered 12-inch o.c. DDP DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -165 (Lim. 9) C-A-15 - - DXC DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -180 (Lim. 9) C-A-16 Min. 0.5-inch Duro-Guard II DG-CR or DG-BM ribbon adhered 12-inch o.c. HD-G DG-CR or DG-BM ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -172.5 (Lim. 9) C-A-17 Min. 0.5-inch EPS, II-A, II-H DG-OB ribbon adhered 12-inch o.c. HD-H, III-A, III-H, DDP, SR, EPS FGF DG-OB ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -172.5 (Lim. 9) C-A-18 Min. 0.5-inch EPS FGF, II-A, or II-H DG-CR or DG-BM ribbon adhered 12-inch o.c. - - DL, DT, DF or DFP WB II, SB IV, or CR-20 -180 (Lim. 9) C-A-19 Min. 0.5-inch II-G DG-OS ribbon adhered 12-inch o.c. SR or EPS FGF DG-OS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -195 (Lim. 9) C-A-20 Min. 0.5-inch EPS FGF, II-A, or II-H DG-OB ribbon adhered 12-inch o.c. - - DT, DF or DFP WB II (Fleece only), SB IV, or CR-20 -195 (Lim. 9) C-A-21 Min. 0.5-inch EPS, II-A, or II-H DG-OB ribbon adhered 12-inch o.c. DDP, EPS FGF, III-A,or SR DG-OB ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -195 (Lim. 9) C-A-22 Min. 1-inch Duro-Guard II DG-CR or DG-BM ribbon adhered 12-inch o.c. DDP DG-CR or DG-BM ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -202.5 (Lim. 9) C-A-23 Min. 0.5-inch II-G DG-OS ribbon adhered 12-inch o.c. - - DL, DT, DF or DFP WB II, SB IV, or CR-20 -202.5 (Lim. 9) C-A-24 Min. 1.5-inch Duro-Guard II DG-CR or DG-BM ribbon adhered 4-inch o.c. DDP DG-CR or DG-BM ribbon adhered 4-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -225 (Lim. 9) C-A-25 Min. 0.5-inch II-G DG-CR or DG-BM ribbon adhered 12-inch o.c. - - DL, DT, DF or DFP WB II, SB IV, or CR-20 -232.5 (Lim. 9) C-A-26 OPTIONAL II-A DG-CR or DG-BM ribbon adhered 12-inch o.c. DXF DG-CR or DG-BM ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -300 (Lim. 9) C-A-27 OPTIONAL II-A DG-CR or DG-BM ribbon adhered 12-inch o.c. DXF DG-CR or DG-BM ribbon adhered 12-inch o.c. DL SB IV -300 (Lim. 9) C-A-28 OPTIONAL II-A DG-CR or DG-BM ribbon adhered 12-inch o.c. DXF DG-CR or DG-BM ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -300 (Lim. 9) C-A-29 OPTIONAL II-A DG-CR or DG-BM ribbon adhered 12-inch o.c. DXF DG-CR or DG-BM ribbon adhered 12-inch o.c. DFP CR-20 -300 (Lim. 9) C-A-30 OPTIONAL II-A DG-OB or DG-OS ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -382.5 (Lim. 9) C-A-31 OPTIONAL II-A DG-OB or DG-OS ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DL SB IV -382.5 (Lim. 9) C-A-32 OPTIONAL II-A DG-OB or DG-OS ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -382.5 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 7 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with All Layers Adhered over Concrete Deck (New or Existing) System No. Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) C-A-33 OPTIONAL II-A DG-OB or DG-OS ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DFP CR-20 -382.5 (Lim. 9) C-A-34 OPTIONAL II-A DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -382.5 (Lim. 9) C-A-35 OPTIONAL II-A DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL SB IV -382.5 (Lim. 9) C-A-36 OPTIONAL II-A DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -382.5 (Lim. 9) C-A-37 OPTIONAL II-A DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DFP CR-20 -382.5 (Lim. 9) C-A-38 Min. 1.5-inch II-A or II-H Olybond Classic ribbon adhered 12-inch o.c. SR Olybond Classic ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -457.5 (Lim. 9) C-A-39 OPTIONAL II-A ASTM D 312, Type IV hot asphalt DXF ASTM D 312, Type IV hot asphalt DL, DT, DF or DFP WB II -495 (Lim. 9) C-A-40 OPTIONAL II-A ASTM D 312, Type IV hot asphalt DXF ASTM D 312, Type IV hot asphalt DL SB IV -495 (Lim. 9) C-A-41 OPTIONAL II-A ASTM D 312, Type IV hot asphalt DXF ASTM D 312, Type IV hot asphalt DF Duro-Fleece Membrane Adhesive -495 (Lim. 9) C-A-42 OPTIONAL II-A ASTM D 312, Type IV hot asphalt DXF ASTM D 312, Type IV hot asphalt DFP CR-20 -495 (Lim. 9) C-A-43 - - - - DF or DFP CR-20 -502.5 (Lim. 9) C-A-44 - - - - DF or DFP WB II -502.5 (Lim. 9) C-A-45 - - - - DFP WB II -672.5 (Lim. 9) C-A-46 - - - - DFP CR-20 -1,025 (Lim. 9) Assemblies with Adhered Membranes over Insulated Concrete Deck (New, Existing or Recover) System No. Base Insulation Base Insulation Attachment Top Insulation or Base Sheet Top Insulation or Base Sheet Attachment Membrane Membrane Attachment MDP (psf) C-AM-1 Min. 0.5-inch Approved Insulation Simultaneously secured with top layer Min. 1.5-inch II-A, II-G, III-A, III-H, IV-A, or Min. 0.5-inch SR DL Plates & Fasteners secured 16 per 4 ft x 8 ft board DL, DT, DF or DFP WB II, SB IV, or CR-20 -45 (Lim. 9) C-AM-2 Min. 0.5-inch Approved Insulation Simultaneously secured with top layer JM Invinsa Roof Board DL Plates & Fasteners secured 16 per 4 ft x 8 ft board DL SB IV -45 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 8 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with Adhered Membranes over Insulated Concrete Deck (New, Existing or Recover) System No. Base Insulation Base Insulation Attachment Top Insulation or Base Sheet Top Insulation or Base Sheet Attachment Membrane Membrane Attachment MDP (psf) C-AM-3 Min. 0.5-inch Approved Insulation Simultaneously secured with top layer SR DL Plates & Fasteners secured at a rate of one fastener per 1.33-ft2 DL, DT, DF or DFP WB II, SB IV, or CR-20 -45 (Lim. 9) C-AM-4 Min. 1.5-inch Approved Insulation DL Plates & #15 Fasteners secured at a rate of 16 per 4 ft x 8 ft board Min. 0.25-inch DD or II-A Duro-Fleece Membrane Adhesive ribbons spaced 6-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -45 (Lim. 9) C-AM-5 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch II-A, II-G, II-H, III-A; Min. 2-inch IV-A; or Min. 0.5-inch SR or DDP DL Plates & Fasteners secured at a rate of 16 per 4 ft x 8 ft board DL, DT, DF or DFP WB II, SB IV, or CR-20 -45 (Lim. 9) C-AM-6 OPTIONAL Approved Insulation Simultaneously secured with top layer SR or DDP DL Plates & Fasteners secured at a rate of 16 per 4 ft x 8 ft board DL, DT, DF or DFP WB II, SB IV, or CR-20 -45 (Lim. 9) C-AM-7 Min. 1.5-inch Approved Insulation Simultaneously secured with top layer DDP or SR DL Plates & Fasteners secured at a rate of 24 per 4 ft x 8 ft board DL, DT, DF or DFP WB II, SB IV, or CR-20 -67.5 (Lim. 7) C-AM-8 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch II-A, II-G or III-A; or Min. 2-inch IV-A DL Plates & Fasteners secured at a rate of 24 per 4 ft x 8 ft board DF or DFP WB II -67.5 (Lim. 7) C-AM-9 Min. 1.5-inch Approved Insulation Simultaneously secured with top layer DDP or SR DL Plates & Fasteners secured at a rate of 20 per 4 ft x 8 ft board DL, DT, DF or DFP WB II, SB IV, or CR-20 -67.5 (Lim. 7) C-AM-10 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 2-inch IV-A DL Plates & Fasteners secured at a rate of 16 per 4 ft x 8 ft board DL, DT, DF or DFP SB IV or WB II -90 (Lim. 7) Induction Welded Assemblies over Concrete Deck (New, Existing, or Recover) System No. Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) C-W-1 OPTIONAL Approved Insulation Simultaneously secured with top layer Approved Insulation Duro-Bond secured 6 per 4 ft x 8 ft board DL or DT Induction welded to each insulation plate -45 (Lim. 9) C-W-2 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch Approved Insulation Duro-Bond secured 6-inch o.c. in rows spaced 60-inches o.c. DL or DT Induction welded to each insulation plate -45 (Lim. 7) C-W-3 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch Approved Insulation Duro-Bond secured 12-inch o.c. in rows spaced 48-inches o.c. DL60 Induction welded to each insulation plate -45 (Lim. 7) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 9 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Induction Welded Assemblies over Concrete Deck (New, Existing, or Recover) System No. Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) C-W-4 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch Approved Insulation Duro-Bond secured 6-inch o.c. in rows spaced 120-inches o.c. DL60 Induction welded to each insulation plate -45 (Lim. 7) C-W-5 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch Approved Insulation Duro-Bond secured 6-inch o.c. in rows spaced 72-inches o.c. DL or DT Induction welded to each insulation plate -52.5 (Lim. 7) C-W-6 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch Approved Insulation Duro-Bond secured 6-inch o.c. in rows spaced 96-inches o.c. DL60 Induction welded to each insulation plate -52.5 (Lim. 7) C-W-7 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch Approved Insulation Duro-Bond secured 12 per 4 ft x 8 ft board DL or DT Induction welded to each insulation plate -52.5 (Lim. 7) C-W-8 OPTIONAL Approved Insulation Simultaneously secured with top layer Approved Insulation Duro-Bond secured 12 per 4 ft x 8 ft board DT Induction welded to each insulation plate -52.5 (Lim. 7) C-W-9 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch Approved Insulation Duro-Bond secured 6-inch o.c. in rows spaced 48-inches o.c. DL or DT Induction welded to each insulation plate -82.5 (Lim. 7) C-W-10 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch Approved Insulation Duro-Bond secured 6-inch o.c. in rows spaced 60-inches o.c. DL60 Induction welded to each insulation plate -82.5 (Lim. 7) C-W-11 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch Approved Insulation Duro-Bond secured 6-inch o.c. in rows spaced 48-inches o.c. DL60 Induction welded to each insulation plate -82.5 (Lim. 7) Mechanically Fastened Assemblies over Concrete Deck (New, Existing, or Recover) System No. Insulation Membrane Fasteners Attachment MDP (psf) C-M-1 Min 1-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Poly-Plates or Cleat Plates Fastened 12-inch o.c. along 6-wide tabs spaced 120-inch o.c. -30 (Lim. 7; Non- HVHZ) C-M-2 Min. 0.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Poly-Plates or Cleat Plates Fastened 12-inch o.c. along 3-inch wide tabs spaced 60-inches o.c. -45 (Lim. 7) C-M-3 Min. 0.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Poly-Plates or Cleat Plates Fastened 6-inch o.c. along 3-inch wide tabs spaced 84-inches o.c. -45 (Lim. 7) C-M-4 Min. 0.5-inch Approved Insulation DT Duro-Last #14 Concrete Screw with Duro-Last Cleat Plates Fastened 12-inch o.c. within laps spaced 116-inch o.c. -45 (Lim. 7) C-M-5 Min 1.5-inch Approved Insulation DT Duro-Last #14 Concrete Screw with Duro-Last Cleat Plates Fastened 12-inch o.c. within laps spaced 56-inch o.c. -45 (Lim. 7) C-M-6 Min. 0.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Poly-Plates or Cleat Plates Fastened 18-inch o.c. along 3-inch wide tabs spaced 28-inches o.c. -52.5 (Lim. 7) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 10 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Assemblies over Concrete Deck (New, Existing, or Recover) System No. Insulation Membrane Fasteners Attachment MDP (psf) C-M-7 Min. 0.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Poly-Plates or Cleat Plates Fastened 6-inch o.c. along 3-inch wide tabs spaced 60-inches o.c. -52.5 (Lim. 7) C-M-8 Min. 0.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Poly-Plates or Cleat Plates Fastened 6-inch o.c. along 6-inch wide tabs spaced 120-inches o.c. -52.5 (Lim. 7) C-M-9 Min. 1.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last 3-inch Metal Plates Fastened 12-inch o.c. along 6-inch wide tabs spaced 57-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -52.5 (Lim. 7) C-M-10 Min. 1.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last 3-inch Metal Plates Fastened 12-inch o.c. along 6-inch wide tabs spaced 84-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -52.5 (Lim. 7) C-M-11 Min. 0.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Cleat Plates Fastened 6-inch o.c. along 3-inch wide tabs spaced 84-inches o.c. -60 (Lim. 7) C-M-12 Min. 0.5-inch Approved Insulation DT Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Poly-Plates or Cleat Plates Fastened 6-inch o.c. along 6-inch wide laps spaced 54-inch o.c.; fastener centered 1.25-inches from edge of tab -67.5 (Lim. 7) C-M-13 Min. 0.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Batten Bar Fastened 6-inch o.c. along 3-inch wide tabs spaced 60-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -67.5 (Lim. 7) C-M-14 Min. 1.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw with Duro-Last Cleat Plates Fastened 12-inch o.c. along 6-inch wide tabs spaced 57-inches o.c. Tab Sealer 4725 applied at 30 ft2/gal. -67.5 (Lim. 7) C-M-15 Min. 0.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last 3-inch Metal Plates Fastened 6-inch o.c. along 6-inch wide tabs spaced 120-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -82.5 (Lim. 7) C-M-16 Min. 1.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Cleat Plates Fastened 6-inch o.c. along 6-inch wide tabs spaced 84-inches o.c. Tab Sealer 4725 applied at 30 ft2/gal. -97.5 (Lim. 7) C-M-17 Min. 1.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Poly-Plates or Cleat Plates Fastened 6-inch o.c. along 3-inch wide tabs spaced 28-inches o.c. -105 (Lim. 7) C-M-18 Min. 0.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last 3-inch Metal Plates Fastened 6-inch o.c. along 6-inch wide tabs spaced 57-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -105 (Lim. 7) C-M-19 Min. 0.5-inch Approved Insulation DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last Cleat Plates Fastened 6-inch o.c. along 6-inch wide tabs spaced 25-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -142.5 (Lim. 7) Assemblies with All Layers Adhered over CWF Deck (New or Existing) System No. Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) CW -A-1 Min. 1-inch EPS FGF DG-TF ribbon adhered 12-inch o.c. OPTIONAL DDP, DXC, DXF, HD-A, HD-G, or SR DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -60 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 11 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with All Layers Adhered over CWF Deck (New or Existing) System No. Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) CW -A-2 Min. 1-inch III-H DG-TF ribbon adhered 12-inch o.c. OPTIONAL DDP, DXC, DXF, HD-A, HD-G, or SR DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -90 (Lim. 9) CW -A-3 OPTIONAL Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. DXF or SR DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -97.5 (Lim. 9) CW -A-4 Min. 0.5-inch EPS FGF, II-A, II-G, II-H Duro-Grip ribbon adhered 12-inch o.c. - - DL, DT, DF or DFP WB II, SB IV, or CR-20 -97.5 (Lim. 9) CW-A-5 Min. 0.5-inch II-G Duro-Grip ribbon adhered 12-inch o.c. HD-G, DDP, EPS FGF, or SR DG-IS, DG-OB or DG-OS DL, DT, DF or DFP WB II, SB IV, or CR-20 -97.5 (Lim. 9) CW-A-6 Min. 0.5-inch EPS, II-A, II-G, II-H Duro-Grip ribbon adhered 12-inch o.c. HD-A, HD-G, DDP, EPS FGF, III-A, III-H, IV-A, or SR DG-OB or DG-IS DL, DT, DF or DFP WB II, SB IV, or CR-20 -97.5 (Lim. 9) CW-A-7 Min. 0.5-inch EPS, II-A, II-G, II-H Duro-Grip ribbon adhered 12-inch o.c. DXF or DXC Duro-Grip ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -97.5 (Lim. 9) CW -A-8 OPTIONAL Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. HD-H DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -112.5 (Lim. 9) CW -A-9 Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. OPTIONAL DDP, HD-G, or DXC DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -120 (Lim. 9) CW -A-10 OPTIONAL Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. HD-G DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -120 (Lim. 9) CW -A-11 Min. 1-inch II-H DG-TF ribbon adhered 12-inch o.c. OPTIONAL DDP or DXC DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -127.5 (Lim. 9) CW -A-12 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -150 (Lim. 9) CW-A-13 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DL SB IV -150 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 12 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with All Layers Adhered over CWF Deck (New or Existing) System No. Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) CW-A-14 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -150 (Lim. 9) CW-A-15 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DFP, DF CR-20 -150 (Lim. 9) CW-A-16 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -150 (Lim. 9) CW -A-17 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL SB IV -150 (Lim. 9) CW -A-18 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -150 (Lim. 9) CW -A-19 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DFP or DF CR-20 -150 (Lim. 9) CW -A-20 OPTIONAL Min. 1-inch EPS DG-TF ribbon adhered 12-inch o.c. DDP DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -165 (Lim. 9) CW -A-21 - - DXC DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -180 (Lim. 9) CW -A-22 OPTIONAL II-G DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -180 (Lim. 9) CW -A-23 OPTIONAL II-G DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DL SB IV -180 (Lim. 9) CW -A-24 OPTIONAL II-G DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -180 (Lim. 9) CW -A-25 OPTIONAL II-G DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DFP, DF CR-20 -180 (Lim. 9) CW -A-26 OPTIONAL II-G DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -205 (Lim. 9) CW -A-27 OPTIONAL II-G DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL SB IV -205 (Lim. 9) CW -A-28 OPTIONAL II-G DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -205 (Lim. 9) CW -A-29 OPTIONAL II-G DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DFP, DF CR-20 -205 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 13 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Assemblies over CWF Deck (New, Existing, or Recover) System No. Insulation Membrane Fasteners Attachment MDP (psf) CW -M-1 - DL Duro-Last Auger Fasteners and Auger Plates Attached 6-inch o.c. within 3-inch tabs spaced 60-inch o.c. -30 (Lim. 7; Non- HVHZ) CW -M-2 - DL Duro-Last Auger Fasteners and Auger Plates with Dow ENERFOAM™ Attached 6-inch o.c. along 3-inch tabs spaced 60-inch o.c. -37.5 (Lim. 7; Non- HVHZ) CW -M-3 Min. 0.5-inch Approved Insulation DL Duro-Last Auger Fasteners and Auger Plates Attached 6-inch o.c. along 6-inch tabs spaced 57-inch o.c. -45 (Lim. 7) CW -M-4 Min. 0.5-inch Approved Insulation DL Duro-Last Auger Fasteners and Auger Plates Attached 6-inch o.c. along 6-inch tabs spaced 57-inch o.c. Tab Sealer 4725 applied at 60 ft2/gal. -52.5 (Lim. 7) CW -M-5 - DT or DL Duro-Last Auger Fasteners and Auger Plates with Dow ENERFOAM™ Fastened through the membrane 6-inch o.c. in rows spaced 60-inch o.c.; 10-inch wide membrane welded over fastener rows with 1.5-inch wide heat weld. -67.5 (Lim. 7 CW -M-6 - DT or DL Duro-Last Auger Fasteners and Auger Plates with Dow ENERFOAM™ Fastened through the membrane 6-inch o.c. in rows spaced 96-inch o.c.; 10-inch wide membrane welded over fastener rows with 1.5-inch wide heat weld. -67.5 (Lim. 7 Assemblies with All Layers Adhered over Gypsum Deck (New or Existing) System No. Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) G-A-1 Min. 1-inch EPS FGF DG-TF ribbon adhered 12-inch o.c. OPTIONAL DDP, DXC, DXF, HD-A, HD-G, or SR DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -60 (Lim. 9) G-A-2 Min. 0.5-inch EPS FGF, II-A, II-G, II-H Duro-Grip ribbon adhered 12-inch o.c. - - DL, DT, DF or DFP WB II or SB IV -82.5 (Lim. 9) G-A-3 Min. 0.5-inch II-G Duro-Grip ribbon adhered 12-inch o.c. HD-G, DDP, EPS FGF, or SR Duro-Grip ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -82.5 (Lim. 9) G-A-4 Min. 0.5-inch EPS, II-A, II-G, II-H Duro-Grip ribbon adhered 12-inch o.c. HD-A, HD-G, DDP, EPS FGF, III-A, III-H, IV-A, or SR DG-OB or DG-IS ribbon adhered 12-inch o.c DL, DT, DF or DFP WB II, SB IV, or CR-20 -82.5 (Lim. 9) G-A-5 Min. 0.5-inch EPS, II-A, II-G, II-H Duro-Grip ribbon adhered 12-inch o.c. DXF or DXC Duro-Grip ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -82.5 (Lim. 9) G-A-6 Min. 1-inch III-H DG-TF ribbon adhered 12-inch o.c. OPTIONAL DDP, DXC, DXF, HD-A, HD-G, or SR DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -90 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 14 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with All Layers Adhered over Gypsum Deck (New or Existing) System No. Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) G-A-7 OPTIONAL Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. DXF or SR DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -97.5 (Lim. 9) G-A-8 - - - - DF or DFP CR-20 -105 (Lim. 9) G-A-9 OPTIONAL Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. HD-H DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -112.5 (Lim. 9) G-A-10 Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. OPTIONAL DDP, HD-G, or DXC DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -120 (Lim. 9) G-A-11 OPTIONAL Min. 1-inch EPS, II-A, II-G, II-H, III-A, or III-G DG-TF ribbon adhered 12-inch o.c. HD-G DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -120 (Lim. 9) G-A-12 Min. 1-inch II-H DG-TF ribbon adhered 12-inch o.c. OPTIONAL DDP or DXC DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -127.5 (Lim. 9) G-A-13 OPTIONAL Min. 1-inch EPS DG-TF ribbon adhered 12-inch o.c. DDP DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -165 (Lim. 9) G-A-14 - - DXC DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -180 (Lim. 9) G-A-15 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -180 (Lim. 9) G-A-16 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DL SB IV -180 (Lim. 9) G-A-17 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -180 (Lim. 9) G-A-18 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DF or DFP CR-20 -180 (Lim. 9) G-A-19 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -180 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 15 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with All Layers Adhered over Gypsum Deck (New or Existing) System No. Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) G-A-20 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL SB IV -180 (Lim. 9) G-A-21 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -180 (Lim. 9) G-A-22 OPTIONAL EPS, II-A, II-G, II-H DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DF or DFP CR-20 -180 (Lim. 9) G-A-23 OPTIONAL EPS, II-A, II-H DG-OS ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -195 (Lim. 9) G-A-24 OPTIONAL EPS, II-A, II-H DG-OS ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DL SB IV -195 (Lim. 9) G-A-25 OPTIONAL EPS, II-A, II-H DG-OS ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -195 (Lim. 9) G-A-26 OPTIONAL EPS, II-A, II-H DG-OS ribbon adhered 12-inch o.c. DXF DG-OB or DG-OS ribbon adhered 12-inch o.c. DF or DFP CR-20 -195 (Lim. 9) G-A-27 OPTIONAL EPS, II-A, II-H DG-OS ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -195 (Lim. 9) G-A-28 OPTIONAL EPS, II-A, II-H DG-OS ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL SB IV -195 (Lim. 9) G-A-29 OPTIONAL EPS, II-A, II-H DG-OS ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -195 (Lim. 9) G-A-30 OPTIONAL EPS, II-A, II-H DG-OS ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DF or DFP CR-20 -195 (Lim. 9) G-A-31 OPTIONAL II-A DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II -217.5 (Lim. 9) G-A-32 OPTIONAL II-A DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DL SB IV -217.5 (Lim. 9) G-A-33 OPTIONAL II-A DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DF Duro-Fleece Membrane Adhesive -217.5 (Lim. 9) G-A-34 OPTIONAL II-A DG-OB ribbon adhered 12-inch o.c. DXC DG-OB, DG-OS or DG-IS ribbon adhered 12-inch o.c. DF or DFP CR-20 -217.5 (Lim. 9) Mechanically Fastened Assemblies over Poured Gypsum Deck (New or Existing) System No. Insulation Membrane Fasteners Attachment MDP (psf) G-M-1 - DT Min. 1.8-inch TRUFAST Twin Loc-Nail Assembled Fastener Fastened through the membrane 6-inch o.c. in rows spaced 60-inch o.c.; 10-inch wide cover strip welded over fastener rows with 1.5-inch wide heat weld. -30 (Lim. 7; Non- HVHZ) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 16 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Assemblies over Poured Gypsum Deck (New or Existing) System No. Insulation Membrane Fasteners Attachment MDP (psf) G-M-2 - DL VERSA-FAST Metal Plates and TRUFAST VERSA-FAST Fasteners Fastened 12-inch o.c. within the 3-inch tabs with one (1) TRUFAST VERSA-FAST Fastener in the center and two (2) TRUFAST VERSA-FAST Fasteners in the perimeter such that one hole is left empty between them; Tabs spaced 60-inch o.c. -30 (Lim. 7; Non- HVHZ) G-M-3 Duro-Guard EPS Fan Fold DL Min. 3-inch Duro-Last Auger Fasteners and Auger Plates Fastened 6-inch o.c. along 3-wide tabs spaced 60-inch o.c. -37.5 (Lim. 7; Non- HVHZ) G-M-4 - DT or DL Min. 2.5-inch Duro-Last Auger Fasteners and Auger Plates or TRUFAST Twin Loc Coiled Batten Bar and min. 1.8-inch TRUFAST Twin Loc-Nail Batten Fastener Fastened through the membrane 6-inch o.c. in rows spaced 48-inch o.c.; 10-inch wide cover strip welded over fastener rows with 1.5-inch wide heat weld. -45 (Lim. 7) G-M-5 - DL VERSA-FAST Metal Plates and TRUFAST VERSA-FAST Fasteners Fastened 6-inch o.c. within the 3-inch tabs with one (1) TRUFAST VERSA-FAST Fastener in the center and two (2) TRUFAST VERSA-FAST Fasteners in the perimeter such that one hole is left empty between them; Tabs spaced 60-inch o.c. -52.5 (Lim. 7) G-M-6 - DT or DL Min. 1.8-inch TRUFAST Twin Loc-Nail Assembled Fastener Fastened through the membrane 6-inch o.c. in rows spaced 48-inch o.c.; 10-inch wide cover strip welded over fastener rows with 1.5-inch wide heat weld. -60 (Lim. 7) G-M-7 - DT or DL TRUFAST Twin Loc Coiled Batten Bar and min. 1.8-inch TRUFAST Twin Loc-Nail Batten Fastener Fastened through the membrane 3-inch o.c. in rows spaced 48-inch o.c.; 10-inch wide cover strip welded over fastener rows with 1.5-inch wide heat weld. -82.5 (Lim. 7) Adhered Lightweight Insulating Concrete Assemblies over Concrete Deck (New or Existing) System No. LWIC Membrane Membrane Attachment MDP (psf) LC-A-1 Min. 300 psi Celcore MF with HS Rheology Admixture DL, DT, DF or DFP WB II, SB IV, or CR-20 -45 (Lim. 9) LC-A-2 Min. 330 psi LWIC (MCRF ≥ 185 lbf using Duro-Last Auger Fasteners) DL, DT, DF or DFP WB II, SB IV, or CR-20 -45 (Lim. 9) LC-A-3 Min. 160 psi LWIC DF or DFP CR-20 -62.5 (Lim. 9 HVHZ only) LC-A-4 Min. 270 psi Elastizell with Zell-Crete Fibers DL or DT WB II -75 (Lim. 9) LC-A-5 Min. 340 psi Celcore MF with HS Rheology Admixture above Celcore S-1 DL, DT, DF or DFP WB II, SB IV, or CR-20 -82.5 (Lim. 9) LC-A-6 Min. 390 psi Celcore MF with HS Rheology Admixture above Celcore S-1. DL, DT, DF or DFP WB II, SB IV, or CR-20 -90 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 17 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Adhered Lightweight Insulating Concrete Assemblies over Concrete Deck (New or Existing) System No. LWIC Membrane Membrane Attachment MDP (psf) LC-A-7 Min. 270 psi Elastizell with Zell-Crete Fibers DL or DT SB IV -90 (Lim. 9) LC-A-8 Min. 250 psi Elastizell with Zell-Crete Fibers and topped with Zell-erator tor Sealer DF or DFP CR-20 -137.5 (Lim. 9 HVHZ only) LC-A-9 Min. 300 psi Celcore MF with HS Rheology Admixture topped with Celcore PVA curing compound DF or DFP CR-20 -162.5 (Lim. 9 HVHZ only) LC-A-10 Min. 300 psi Celcore MF with HS Rheology Admixture topped with Celcore PVA curing compound DL, DT, DF or DFP WB II -285 (Lim. 9) LC-A-11 Min. 200 psi LWIC (MCRF ≥ 60 lbf using TRUFAST FM-90 Base Sheet Fastener) DL, DT, DF or DFP WB II -457.5 (Lim. 9) LC-A-12 Min. 200 psi Elastizell with Zell-Crete Fibers DL, DT, DF or DFP WB II -485 (Lim. 9) Mechanically Attached Lightweight Insulating Concrete Assemblies over Concrete Deck (New or Existing) System No. LWIC Membrane Membrane Attachment MDP (psf) LC-M-1 Min. 330 LWIC (MCRF ≥ 185 lbf using Duro-Last Auger Fasteners) DT or DL Duro-Last Auger Fasteners and Auger Plates attached 6-inch o.c. in rows spaced 60 in. o.c. and encapsulated with 6-inch wide cover strip of DL -37.5 (Lim. 7; Non- HVHZ) LC-M-2 Min. 360 LWIC (MCRF ≥ 91 lbf using TRUFAST Twin Loc-Nail Batten Fastener) DT or DL TRUFAST Twin Loc Coiled Batten Bar and min. 1.8” TRUFAST Twin Loc-Nail Batten Fastener attached 3-inch o.c. in rows spaced 48-inch o.c. and encapsulated with 6-inch wide cover strip of DL -45 (Lim. 7) Adhered Lightweight Insulating Concrete Assemblies over Steel Deck (New or Existing) System No. Deck Detail LWIC Membrane Membrane Attachment MDP (psf) LS-A-1 G33, L5, P, S15 Min. 300 psi Celcore MF with HS Rheology Admixture DL, DT, DF or DFP WB II, SB IV, or CR-20 -45 (Lim. 9) LS-A-2 Min. 26 ga. HD-Dek, Vented, G80, L5, P, S15 Min. 360 psi LWIC (MCRF ≥ 91 lbf using TRUFAST Twin Loc-Nail Batten Fastener) DL, DT, DF or DFP WB II, SB IV, or CR-20 -45 (Lim. 9) LS-A-3 G33, L6, P, S18 Min. 340 psi Celcore MF with HS Rheology Admixture above Celcore S-1 DL, DT, DF or DFP WB II, SB IV, or CR-20 -82.5 (Lim. 9) LS-A-4 G33, L5, P, S18 Min. 390 psi Celcore MF with HS Rheology Admixture above Celcore S-1. DL, DT, DF or DFP WB II, SB IV, or CR-20 -90 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 18 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Adhered Lightweight Insulating Concrete Assemblies over Steel Deck (New or Existing) System No. Deck Detail LWIC Membrane Membrane Attachment MDP (psf) LS-A-5 G33, L5, F1, S15 Min. 330 psi Celcore MF with HS Rheology Admixture; Secure lightweight with OMG HD Batten Bars or OMG Polymer Batten Strips oriented with the length of the bar perpendicular to the deck flutes and spaced 18-inch o.c.; Secure battens with OMG XHD fastened 12-inch o.c. DL, DT, DF or DFP WB II, SB IV, or CR-20 -97.5 (Lim. 9) LC-A-6 G33, L5 Min. 160 psi LWIC DF or DFP CR-20 -175 (Lim. 9 HVHZ only) LC-A-7 G33, L5 Min. 250 psi Elastizell with Zell-Crete Fibers and topped with Zell-erator tor Sealer DF or DFP CR-20 -295 (Lim. 9 HVHZ only.) Mechanically Attached Lightweight Insulating Concrete Assemblies over Steel Deck (New or Existing) System No. Deck Detail LWIC Membrane Membrane Attachment MDP (psf) LS-M-1 Min. 26 ga. HD-Dek, Vented, G80, L5, P, S15 Min. 330 LWIC (MCRF ≥ 185 lbf using Duro-Last Auger Fasteners) DT or DL Duro-Last Auger Fasteners and Auger Plates attached 6-inch o.c. in rows spaced 60 in. o.c. and encapsulated with 6-inch wide cover strip of DL -37.5 (Lim. 7; Non- HVHZ) LS-M-2 Min. 26 ga. HD-Dek, Vented, G80, L5, P, S15 Min. 360 LWIC (MCRF ≥ 91 lbf using TRUFAST Twin Loc-Nail Batten Fastener) DT or DL TRUFAST Twin Loc Coiled Batten Bar and min. 1.8” TRUFAST Twin Loc-Nail Batten Fastener attached 3-inch o.c. in rows spaced 48-inch o.c. and encapsulated with 6-inch wide cover strip of DL -45 (Lim. 7; Non- HVHZ) Adhered Recover Assemblies System No. Existing Roof Insulation Insulation Attachment Membrane Membrane Attachment MDP (psf) R-A-1 Steel Deck (G33, L6, F1, S24) DDP or SR Duro-Last #14 HD Fastener and Duro-Last 3-inch Metal Plates fastened at a rate of 24 per 4 ft x 8 ft board DL, DT, DF or DFP WB II, SB IV, or CR-20 -67.5 (Lim. 7) R-A-2 Steel Deck (G33, L6, F1, S24) Min. 0.5-inch SR TRUFAST DP #12 Fasteners and TRUFAST 3” Metal Insulation Plates fastened at a rate of 32 per 4 ft x 8 ft board DL, DT, DF or DFP SB IV or WB II -82.5 (Lim. 7) R-A-3 Smooth or Granule Surfaced BUR , Granule Surfaced SBS or Granule Surfaced APP Cap Sheet. Subcomponents adhered - - DF CR-20 -120 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 19 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Adhered Recover Assemblies System No. Existing Roof Insulation Insulation Attachment Membrane Membrane Attachment MDP (psf) R-A-4 Granule Surfaced BUR, SBS or APP Cap Sheet. Subcomponents mechanically attached. - - DFP CR-20 -150 (Lim. 9) R-A-5 Smooth or Granule Surfaced BUR , Granule Surfaced SBS or Granule Surfaced APP Cap Sheet. Subcomponents adhered. - - DFP CR-20 -370 (Lim. 9) Mechanically Fastened Recover Assemblies System No. Existing Roof Insulation Insulation Attachment Membrane Membrane Attachment MDP (psf) R-M-1 CWF Deck or Gypsum Deck - - DL Duro-Last Auger Fasteners and Auger Plates fastened through the membrane 6-inch o.c. in rows spaced 48-inch o.c.; 10-inch wide membrane welded over fastener rows with 1.5-inch wide heat weld. -30 (Lim. 7; Non- HVHZ) R-M-2 Poured Gypsum - - DL VERSA-FAST Metal Plates fastened 12-inch o.c. within the 3- inch tabs with one (1) TRUFAST VERSA-FAST Fastener in the center and two (2) TRUFAST VERSA-FAST Fasteners in the perimeter such that one hole is left empty between them; Tabs spaced 60-inch o.c. -30 (Lim. 7; Non- HVHZ) R-M-3 Steel Deck (G33, L6, P, S24) OPTIONAL Approved Insulation Preliminarily secured DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Cleat Plates fastened 12-inch o.c. within 6-inch wide laps spaced 114-inch o.c. -37.5 (Lim. 7; Non- HVHZ) R-M-4 Poured Gypsum - - DT or DL Duro-Last Auger Fasteners (min. 2.5-inch penetration into substrate) and Auger Plates or TRUFAST Twin Loc Coiled Batten Bar and TRUFAST Twin Loc- Nail Batten Fastener fastened through the membrane 6-inch o.c. in rows spaced 48-inch o.c.; 10-inch wide cover strip welded over fastener rows with 1.5-inch wide heat weld. -45 (Lim. 7) R-M-5 Steel Deck (G33, L6, F1, S24) - - DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Cleat Plates fastened 12-inch o.c. within 6-inch wide laps spaced 114-inch o.c. -45 (Lim. 7) R-M-6 Min. 24 ga. R-Panel or PBR panel metal roofing at max. 5ft span and fastened 12-inch o.c. at each support with min. #12 HWH screws with min. 0.5-inch washers Approved Insulation filled between ribs. Min. 0.5-inch Approved Insulation above ribs Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. within 3-inch wide tabs spaced 60-inch o.c. -45 (Lim. 7) R-M-7 Steel Deck (G33, L6, F1, S0) OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Poly-Plates or Cleat Plates fastened 6-inch o.c. along 6-inch wide tabs spaced 120-inch o.c. -45 (Lim. 7) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 20 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Recover Assemblies System No. Existing Roof Insulation Insulation Attachment Membrane Membrane Attachment MDP (psf) R-M-8 Steel Deck (G33, L6, F1, S24) OPTIONAL Approved Insulation Preliminarily secured DT (120-inch wide) Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Cleat Plates fastened 12-inch o.c. within 4-inch wide laps spaced 116-inch o.c. -45 (Lim. 7) R-M-9 Wood Deck (T19/32, L24, 0.113-6/6) - - DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 6-inch wide laps spaced 114-inch o.c.; fastener centered 1.25-inches from edge of tab -45 (Lim. 7) R-M-10 Steel Deck (G33, L6, PW or F1, S24) - - DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 6-inch wide laps spaced 114-inch o.c.; fastener centered 1.25-inches from edge of tab -45 (Lim. 7) R-M-11 Min. 225 psi LWIC over Steel Deck (Min. 26 ga. HD-Dek, Vented, G80, L5, P, S15) - - DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 3-inch wide tabs spaced 60-inch o.c. -45 (Lim. 7) R-M-12 Min. 26 ga. R-Panel or PBR panel metal roofing at max. 5ft span and fastened 6-inch o.c. at each support with min. #12 HWH screws Approved Insulation filled between ribs. Min. 0.5-inch Approved Insulation above ribs Preliminarily secured DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates fastened 6-inch o.c. within 6-inch wide laps spaced 54-inch o.c -45 (Lim. 7) R-M-13 Steel Deck (G33, L6, PW, S24) - - DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 6-inch wide laps spaced 54-inch o.c.; fastener centered 1.25-inches from edge of tab -52.5 (Lim. 7) R-M-14 Steel Deck (G33, L6, PW, S0) OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Poly-Plates or Cleat Plates fastened 6-inch o.c. along the 3-inch wide tabs spaced 60-inch o.c. -52.5 (Lim. 7) R-M-15 Wood Deck (T19/32, L24, 0.113-6/6) OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. along 3-inch wide tabs spaced 60-inch o.c. -52.5 (Lim. 7) R-M-16 Wood Deck (T19/32, L24, 8d-6/6) OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Cleat Plates fastened 6-inch o.c. along 6-inch wide tabs spaced 57-inch o.c. (Screws located 2.7-inches from tab edge) -52.5 (Lim. 7) R-M-17 Wood Deck (T19/32, L24, 8d-6/6) OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #14 HD Fastener and Duro-Last 3-inch Metal Plates fastened 6-inch o.c. along 6-inch wide tabs spaced 57-inch o.c. Tab Sealer 4725 applied at a rate of 60 ft2/gal. -52.5 (Lim. 7) R-M-18 Min. 24 ga. R-Panel or PBR panel metal roofing at max. 5ft span and fastened 12-inch o.c. at each support with min. #12 HWH screws with min. 0.5-inch washers Approved Insulation filled between ribs. Min. 0.5-inch Approved Insulation above ribs Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Cleat Plates or Poly-Plates fastened 12-inch o.c. along 3-inch wide tabs spaced 28-inch o.c. -52.5 (Lim. 7) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 21 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Recover Assemblies System No. Existing Roof Insulation Insulation Attachment Membrane Membrane Attachment MDP (psf) R-M-19 Min. 26 ga. R-Panel or PBR panel metal roofing at max. 5ft span and fastened 6-inch o.c. at each support with min. #12 HWH screws Approved Insulation filled between ribs. Min. 0.5-inch Approved Insulation above ribs Preliminarily secured DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates fastened 12-inch o.c. within 6-inch wide laps spaced 24-inch o.c -52.5 (Lim. 7) R-M-20 Poured Gypsum - - DL VERSA-FAST Metal Plates fastened 6-inch o.c. within the 3- inch tabs with one (1) TRUFAST VERSA-FAST Fastener in the center and two (2) TRUFAST VERSA-FAST Fasteners in the perimeter such that one hole is left empty between them; Tabs spaced 60-inch o.c. -52.5 (Lim. 7) R-M-21 Wood Deck (T19/32, L24, 0.113-6/6) OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. along 6-inch wide tabs spaced 120-inch o.c. -60 (Lim. 7) R-M-22 Wood Deck (T15/32, L24, 0.113-6/6) - - DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 6-inch wide laps in rows spaced 24-inch o.c -60 (Lim. 7) R-M-23 Wood Deck (T15/32, L24, 0.113-6/6) - - DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. along 3-inch wide tabs spaced 28-inch o.c. -60 (Lim. 7) R-M-24 Steel Deck (G33, L6, F1, S24) - - DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 6-inch wide laps spaced 54-inch o.c.; fastener centered 1.25-inches from edge of tab -67.5 (Lim. 7) R-M-25 CWF Deck - - DT or DL Duro-Last Auger Fasteners and Auger Plates with Dow ENERFOAM™ fastened through the membrane 6-inch o.c. in rows spaced 60-inch o.c.; 10-inch wide membrane welded over fastener rows with 1.5-inch wide heat weld. -67.5 (Lim. 7 R-M-26 CWF Deck - - DT or DL Duro-Last Auger Fasteners and Auger Plates with Dow ENERFOAM™ fastened through the membrane 6-inch o.c. in rows spaced 96-inch o.c.; 10-inch wide membrane welded over fastener rows with 1.5-inch wide heat weld. -67.5 (Lim. 7 R-M-27 Gypsum Deck - - DT or DL TRUFAST Twin Loc Coiled Batten Bar and TRUFAST Twin Loc-Nail Batten Fastener fastened through the membrane 3-inch o.c. in rows spaced 48-inch o.c.; 10-inch wide cover strip welded over fastener rows with 1.5-inch wide heat weld. -82.5 (Lim. 7) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 22 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Recover Assemblies System No. Existing Roof Insulation Insulation Attachment Membrane Membrane Attachment MDP (psf) R-M-28 Min. 24 ga. R-Panel or PBR panel metal roofing at max. 5ft span and fastened 12-inch o.c. at each support with min. (2) #12 HWH screws with min. 0.5-inch OD washers per rib Approved Insulation filled between ribs. Min. 1-inch Approved Insulation above ribs Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. along 3-inch wide tabs spaced 28-inch o.c. -82.5 (Lim. 7) R-M-29 Concrete Deck OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #14 Concrete Screw or Fluted Concrete Nail with Duro-Last 3-inch Metal Plates fastened 6-inch o.c. along 6-inch wide tabs spaced 120-inch o.c. Tab Sealer 4725 applied at 60 ft2/gal. -82.5 (Lim. 7) Induction Welded Recover Assemblies System No. Existing Roof Weld Plate Weld Plate Attachment Membrane Membrane Attachment MDP (psf) R-W-1 Steel Deck (G33, L6, F1, S24) OMG XHD Fastener with Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate Secured at a rate of 1 per 4.00-ft2 (See Appendix A - Induction Weld Patterns) DL or DT Induction welded to each insulation plate -52.5 (Lim. 7) R-W-2 Steel Deck (G33, L6, P, S24) OMG XHD Fastener with Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate Secured at a rate of 1 per 4.00-ft2 (See Appendix A - Induction Weld Patterns) DL or DT Induction welded to each insulation plate -52.5 (Lim. 7) Assemblies with All Layers Adhered over Steel Deck (New or Existing) System No. Deck Detail Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) S-A-1 G33, L6, F1, S24 OPTIONAL Duro-Guard II Duro-Grip ribbon adhered 6-inch o.c Min. 1.5-inch EPS FGF, II-A, II-G, III-A, III-H, IV-A; or HD-G, HD-G, HD-A, DDP, SR, DXF or DXC Duro-Grip ribbon adhered 6-inch o.c. DL or DT WB II or SB IV -37.5 (Lim. 9; Non- HVHZ) S-A-2 G33, L6, F1, S24 OPTIONAL Duro-Guard II Duro-Grip or DG-TF ribbon adhered 6-inch o.c Min. 1.5-inch EPS FGF, II-A, II-G, III-A, III-H, IV-A; or HD-G, HD-G, HD-A, DDP, SR, DXF or DXC Duro-Grip or DG-TF ribbon adhered 6-inch o.c. DF or DFP WB II or CR-20 -37.5 (Lim. 9; Non- HVHZ) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 23 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with All Layers Adhered over Steel Deck (New or Existing) System No. Deck Detail Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) S-A-3 G33, L6, P, S24 OPTIONAL Duro-Guard II Duro-Grip or DG-TF ribbon adhered 6-inch o.c Min. 1.5-inch EPS FGF, II-A, II-G, III-A, III-H, IV-A; or HD-G, HD-G, HD-A, DDP, SR, DXF or DXC Duro-Grip or DG-TF ribbon adhered 6-inch o.c DL or DT WB II or SB IV -60 (Lim. 9) S-A-4 G33, L6, P, S24 OPTIONAL Duro-Guard II Duro-Grip or DG-TF ribbon adhered 6-inch o.c Min. 1.5-inch EPS FGF, II-A, II-G, III-A, III-H, IV-A; or HD-G, HD-G, HD-A, DDP, SR, DXF or DXC Duro-Grip or DG_TF ribbon adhered 6-inch o.c DF or DFP WB II or CR-20 -60 (Lim. 9) S-A-5 G33, L5 Min. 0.5-inch EPS FGF, II-A, II-G, II-H Duro-Grip ribbon adhered 12-inch o.c. - - DL, DT, DF or DFP WB II, SB IV or CR-20 -82.5 (Lim. 9) S-A-6 G33, L5 Min. 0.5-inch II-G Duro-Grip ribbon adhered 12-inch o.c. HD-G, DDP, DXC, DXF, EPS FGF, or SR Duro-Grip ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV or CR-20 -82.5 (Lim. 9) S-A-7 G33, L5 Min. 0.5-inch EPS, II-A, II-G, II-H Duro-Grip ribbon adhered 12-inch o.c. HD-A, HD-G, DDP, DXC, DXF, EPS FGF, III-A, III-H, IV- A, or SR DG-OB or DG-IS ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV or CR-20 -82.5 (Lim. 9) S-A-8 G33, L5 Min. 1-inch EPS, II-A, II-G, II-H, III-A, III-G, or III-H DG-TF ribbon adhered 12-inch o.c. OPTIONAL (except over EPS) HD-A, HD-G, HD-H, DDP, DXC, DXF, or SR DG-TF ribbon adhered 12-inch o.c. DL, DT, DF or DFP WB II, SB IV or CR-20 -90 (Lim. 9) S-A-9 G33, L6, P, S24 Min. 1.5-inch II-H, III-H, or II-G DG-OS ribbon adhered 6-inch o.c. to the top flange of each deck rib - - DL, DT, DF or DFP WB II, SB IV or CR-20 -90 (Lim. 9) S-A-10 G33, L6, F1, S24 Min. 1.5-inch EPS, EPS FGF, II-H, or III-H DG-OS ribbon adhered 6-inch o.c. to the top flange of each deck rib DXC, DXF, HD-H, EPS FGF, or SR DG-OS ribbon adhered 6-inch o.c. DL, DT, DF or DFP WB II, SB IV or CR-20 -97.5 (Lim. 9) S-A-11 G33, L6, F1, S24 Min. 1.5-inch II-G DG-OS ribbon adhered 6-inch o.c. to the top flange of each deck rib DDP, DXC, DXF, HD-G, or SR DG-OS ribbon adhered 6-inch o.c. DL, DT, DF or DFP WB II, SB IV or CR-20 -97.5 (Lim. 9) S-A-12 G33, L6, P, S24 Min. 1.5-inch EPS, EPS FGF, II-H or III-H DG-OS ribbon adhered 6-inch o.c. to the top flange of each deck rib DXC, DXF, HD-H, EPS FGF, or SR DG-OS ribbon adhered 6-inch o.c. DL, DT, DF or DFP WB II, SB IV or CR-20 -112.5 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 24 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with All Layers Adhered over Steel Deck (New or Existing) System No. Deck Detail Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) S-A-13 G33, L6, F1, S24 Min. 1.5-inch EPS FGF, II-H or III-H DG-OS ribbon adhered 6-inch o.c. to the top flange of each deck rib - - DL, DT, DF or DFP WB II, SB IV or CR-20 -135 (Lim. 9) Assemblies with Adhered Membranes over Steel Deck (New, Existing, or Recover) System No. Deck Detail Base Layer Insulation Base Layer Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) S-AM-1 G33, L5 Min. 1.5-inch Approved Insulation Simultaneously secured with top layer JM Invinsa Roof Board Duro-Last 3-inch Metal Plates with Duro-Last Duro-Coated Hex Head Screws secured at a rate of 16 per 4 ft x 8 ft board DL SB IV -45 (Lim. 9) S-AM-2 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch II-A, II-G, III-A, III-H, IV-A or Min. 0.5-inch SR Duro-Last 3-inch Metal Plates with Duro-Last Duro-Coated Hex Head Screws secured at a rate of 16 per 4 ft x 8 ft board DL, DT, DF or DFP WB II, SB IV or CR-20 -45 (Lim. 9) S-AM-3 G33, L5 Min. 1.5-inch Approved Insulation DL Plates & #15 Fasteners secured at a rate of 16 per 4 ft x 8 ft board Min. 0.25-inch DD or II-A Duro-Fleece Membrane Adhesive ribbons spaced 6-inch o.c. DL, DT, DF or DFP WB II, SB IV or CR-20 -45 (Lim. 9) S-AM-4 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch II-A, II-G, II-H, III-A; Min. 2-inch IV-A; or Min. 0.5-inch SR or DDP DL Plates & #15 Fasteners secured at a rate of 16 per 4 ft x 8 ft board DL, DT, DF or DFP WB II, SB IV or CR-20 -45 (Lim. 9) S-AM-5 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer SR or DDP DL Plates & #15 Fasteners secured at a rate of 16 per 4 ft x 8 ft board DL, DT, DF or DFP WB II, SB IV or CR-20 -45 (Lim. 9) S-AM-6 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 0.5-inch DXF TRUFAST DP #12 Fasteners and TRUFAST 3” Metal Insulation Plates secured at a rate of 1 fastener per 4 ft2 DL, DT, DF or DFP WB II -45 (Lim. 9) S-AM-7 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 0.5-inch DXF TRUFAST DP #12 Fasteners and TRUFAST 3” Metal Insulation Plates secured at a rate of 1 fastener per 4 ft2 DL SB IV -45 (Lim. 9) S-AM-8 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 0.5-inch DXF TRUFAST DP #12 Fasteners and TRUFAST 3” Metal Insulation Plates secured at a rate of 1 fastener per 4 ft2 DF Duro-Fleece Membrane Adhesive -45 (Lim. 9) S-AM-9 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 0.5-inch DXF TRUFAST DP #12 Fasteners and TRUFAST 3” Metal Insulation Plates secured at a rate of 1 fastener per 4 ft2 DF or DFP CR-20 -45 (Lim. 9) S-AM-10 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer DXF DL Plates & Fasteners secured at a rate of 1 fastener per 2.67 ft2 DL, DT, DF or DFP WB II -45 (Lim. 9) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 25 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with Adhered Membranes over Steel Deck (New, Existing, or Recover) System No. Deck Detail Base Layer Insulation Base Layer Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) S-AM-11 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer DXF DL Plates & Fasteners secured at a rate of 1 fastener per 2.67 ft2 DL SB IV -45 (Lim. 9) S-AM-12 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer DXF DL Plates & Fasteners secured at a rate of 1 fastener per 2.67 ft2 DF Duro-Fleece Membrane Adhesive -45 (Lim. 9) S-AM-13 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer DXF DL Plates & Fasteners secured at a rate of 1 fastener per 2.67 ft2 DF or DFP CR-20 -45 (Lim. 9) S-AM-14 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer DXC TRUFAST DP #12 Fasteners and TRUFAST 3” Metal Insulation Plates secured at a rate of 1 fastener per 2.67 ft2 DL, DT, DF or DFP WB II -45 (Lim. 9) S-AM-15 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer DXC TRUFAST DP #12 Fasteners and TRUFAST 3” Metal Insulation Plates secured at a rate of 1 fastener per 2.67 ft2 DL SB IV -45 (Lim. 9) S-AM-16 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer DXC TRUFAST DP #12 Fasteners and TRUFAST 3” Metal Insulation Plates secured at a rate of 1 fastener per 2.67 ft2 DF Duro-Fleece Membrane Adhesive -45 (Lim. 9) S-AM-17 G33, L5 OPTIONAL Approved Insulation Simultaneously secured with top layer DXC TRUFAST DP #12 Fasteners and TRUFAST 3” Metal Insulation Plates secured at a rate of 1 fastener per 2.67 ft2 DF or DFP CR-20 -45 (Lim. 9) S-AM-18 G33, L6 F1, S24 Min. 1.5-inch Approved Insulation Simultaneously secured with top layer DDP or SR DL Plates & Fasteners secured at a rate of 24 per 4 ft x 8 ft board DL, DT, DF or DFP WB II, SB IV or CR-20 -67.5 (Lim. 7) S-AM-19 G33, L6 F1, S24 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 1.5-inch II-A, II-G, III-A; or Min. 2-inch IV-A DL Plates & Fasteners secured at a rate of 24 per 4 ft x 8 ft board DF or DFP WB II -67.5 (Lim. 7) S-AM-20 G33, L6 F1, S24 Min. 1.5-inch Approved Insulation Simultaneously secured with top layer DDP or SR DL Plates & #15 Fasteners secured at a rate of 20 per 4 ft x 8 ft board DL, DT, DF or DFP WB II, SB IV or CR-20 -67.5 (Lim. 7) S-AM-21 G33, L6 F1, S24 Min. 1.5-inch Approved Insulation Simultaneously secured with top layer Min. 0.5-inch SR TRUFAST DP #12 Fasteners and TRUFAST 3” Metal Insulation Plates secured at a rate of 32 per 4 ft x 8 ft board DL, DT, DF or DFP SB IV or WB II -82.5 (Lim. 7) S-AM-22 G33, L6 F1, S24 OPTIONAL Approved Insulation Simultaneously secured with top layer Min. 2-inch IV-A DL Plates & #15 Fasteners secured at a rate of 16 per 4 ft x 8 ft board DL, DT, DF or DFP SB IV or WB II -90 (Lim. 7) Mechanically Fastened Assemblies over Steel Deck (New, Existing, or Recover) System No. Deck Detail Base Insulation Base Insulation Attachment Top Insulation Top Insulation Attacment Membrane Attachment MDP (psf) S-M-1 G33, L6, P or F1, S0 Min 1-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point fasteners and Duro-Last Poly-Plates or Cleat Plates fastened 12-inch o.c. along 6-wide tabs spaced 120-inch o.c. -30 (Lim. 7; Non- HVHZ) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 26 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Assemblies over Steel Deck (New, Existing, or Recover) System No. Deck Detail Base Insulation Base Insulation Attachment Top Insulation Top Insulation Attacment Membrane Attachment MDP (psf) S-M-2 G33, L6, P, S24 Min 0.5-inch Approved Insulation Preliminarily secured - - DT Duro-Last #15 EHD Drill Point fasteners and Duro-Last Cleat Plates fasetened 12- inch o.c. within laps spaced 114-inch o.c. -37.5 (Lim. 7; Non- HVHZ) S-M-3 G80, L5.5 (22 ga) or L6 (18 ga) F1, S24 Min 0.5-inch Approved Insulation Preliminarily secured - - DT Duro-Last #15 EHD Drill Point fasteners and Duro-Last Cleat Plates fasetened 12- inch o.c. within laps spaced 116-inch o.c. -45 (Lim. 7) S-M-4 G33, L6, F1, S24 Min 1.5-inch Approved Insulation Preliminarily secured - - DT Duro-Last #15 EHD Drill Point fasteners and Cleat Plates fastened 12-inch o.c. within laps spaced 56-inch o.c. -45 (Lim. 7) S-M-5 G80, L6, F1, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #14 HD Fastener with Duro-Last Poly-Plates or Cleat Plates fastened 12- inch o.c. along the 3-inch wide tabs spaced 60-inches o.c. -45 (Lim. 7) S-M-6 G80, L6, P, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #14 HD with Duro-Last Poly- Plates or Cleat Plates fastened 6-inch o.c. along the 3-inch wide tabs spaced 84- inches o.c. -45 (Lim. 7) S-M-7 G33, L6, P or F1, S0 Min 1-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point fasteners and Duro-Last Poly-Plates or Cleat Plates attached 6-inch o.c. along 6-wide tabs spaced 120-inch o.c. -45 (Lim. 7) S-M-8 G80, L6, F1W, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last Cleat Plates fastened 12- inch o.c. along the 6-inch wide tabs spaced 120-inches o.c. Tab Sealer 4725 applied at 30 ft2/gal. -45 (Lim. 7) S-M-9 G33, L6, PW or F1, S24 Min. 0.5-inch Approved Insulation Preliminarily secured - - DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 6- inch wide laps spaced 114-inch o.c.; fastener centered 1.25-inches from edge of tab -45 (Lim. 7) S-M-10 G80, L6, F1, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #14 HD Fastener with Duro-Last Poly-Plates or Cleat Plates fastened 18- inch o.c. along the 3-inch wide tabs spaced 28-inches o.c. -52.5 (Lim. 7) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 27 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Assemblies over Steel Deck (New, Existing, or Recover) System No. Deck Detail Base Insulation Base Insulation Attachment Top Insulation Top Insulation Attacment Membrane Attachment MDP (psf) S-M-11 G80, L6, F1, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #14 HD Fastener with Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. along the 3-inch wide tabs spaced 60- inches o.c. -52.5 (Lim. 7) S-M-12 G33, L6, P or F1, S0 Min 1-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point fasteners and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. along 3-wide tabs spaced 60-inch o.c. -52.5 (Lim. 7) S-M-13 G80, L6, F1, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #14 HD Fastener with Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. along the 6-inch wide tabs spaced 120-inches o.c. -52.5 (Lim. 7) S-M-14 G80, L6, PW, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last 3-inch Metal Plates fastened 12-inch o.c. along the 6-inch wide tabs spaced 57-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -52.5 (Lim. 7) S-M-15 G80, L6, PW, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last 3-inch Metal Plates fastened 6-inch o.c. along the 6-inch wide tabs spaced 84-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -52.5 (Lim. 7) S-M-16 G80, L6, F1W, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last Cleat Plates fastened 12- inch o.c. along the 6-inch wide tabs spaced 84-inches o.c. Tab Sealer 4725 applied at 30 ft2/gal. -52.5 (Lim. 7) S-M-17 G80, L6, PW, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last Cleat Plates Fastened 6- inch o.c. along the 3-inch wide tabs spaced 84-inches o.c. -60 (Lim. 7) S-M-18 G33, L6, PW, S24 Min. 0.5-inch Approved Insulation Preliminarily secured - - DT Duro-Last #15 EHD Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 6-inch wide laps spaced 54-inch o.c.; fastener centered 1.25-inches from edge of tab -60 (Lim. 7) S-M-19 G33, L6, F1, S24 Min. 0.5-inch Approved Insulation Preliminarily secured - - DT Duro-Last #15 EHD Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 6-inch wide laps spaced 54-inch o.c.; fastener centered 1.25-inches from edge of tab -67.5 (Lim. 7) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 28 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Assemblies over Steel Deck (New, Existing, or Recover) System No. Deck Detail Base Insulation Base Insulation Attachment Top Insulation Top Insulation Attacment Membrane Attachment MDP (psf) S-M-20 G80, L5, F1, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last Batten Bar fastened 6-inch o.c. within center of 3-inch wide tabs spaced 60-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -67.5 (Lim. 7) S-M-21 G80, L6, F1W, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last Cleat Plates fastened 12- inch o.c. along the 6-inch wide tabs spaced 57-inches o.c. Tab Sealer 4725 applied at 30 ft2/gal. -67.5 (Lim. 7) S-M-22 G80, L6, F1, S30 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL (Inverted) Duro-Last #14 HD Fastener with Duro-Last Poly-Plates or Cleat Plates fastened 12- inch o.c. along the 3-inch wide tabs spaced 27-inches o.c. -75 (Lim. 7) S-M-23 G80, L6, P, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last 3-inch Metal Plates fastened 6-inch o.c. within center of 6-inch wide tabs spaced 120-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -82.5 (Lim. 7) S-M-24 G80, L6, F1W, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last Cleat Plates fastened 6- inch o.c. along the 6-inch wide tabs spaced 120-inches o.c. Tab Sealer 4725 applied at 30 ft2/gal. -82.5 (Lim. 7) S-M-25 G80, L6, F1W, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last Cleat Plates fastened 6- inch o.c. along the 6-inch wide tabs spaced 84-inches o.c. Tab Sealer 4725 applied at 30 ft2/gal. -97.5 (Lim. 7) S-M-26 G80, L6, F1, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #14 HD Fastener with Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. along the 3-inch wide tabs spaced 28- inches o.c. -105 (Lim. 7) S-M-27 G80, L6, P, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last 3-inch Metal Plates fastened 6-inch o.c. along the 6-inch wide tabs spaced 57-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -105 (Lim. 7) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 29 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Assemblies over Steel Deck (New, Existing, or Recover) System No. Deck Detail Base Insulation Base Insulation Attachment Top Insulation Top Insulation Attacment Membrane Attachment MDP (psf) S-M-28 G80, L6, F1W, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last Cleat Plates fastened 6- inch o.c. along the 6-inch wide tabs spaced 57-inches o.c. Tab Sealer 4725 applied at 30 ft2/gal. -135 (Lim. 7) S-M-29 G80, L6, F1, S24 Min. 1.5-inch Approved Insulation Preliminarily secured - - DL Duro-Last #15 EHD Drill Point Fastener with Duro-Last Cleat Plates fastened 6- inch o.c. within center of 6-inch wide tabs spaced 25-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. -142.5 (Lim. 7) Induction Welded Assemblies over Steel Deck (New, Existing, or Recover) System No. Deck Detail Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) S-W-1 G33, L6, F1, S12 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation Duro-Bond #15secured 12-inch o.c. in rows spaced 48-inches o.c. DL60 Induction welded to each insulation plate -45 (Lim. 7) S-W-2 G33, L6, F1, S12 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation Duro-Bond #15secured 6-inch o.c. in rows spaced 120-inches o.c. DL60 Induction welded to each insulation plate -45 (Lim. 7) S-W-3 G33, L5 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation Duro-Bond #15secured 6 per 4 ft x 8 ft board DL or DT Induction welded to each insulation plate -45 (Lim. 9) S-W-4 G33, L6, P, S24 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation OMG XHD Fastener with Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate secured at a rate of 1 per 6.00-ft2 (See Appendix A- Induction Weld Patterns) DL or DT Induction welded to each insulation plate -45 (Lim. 7) S-W-5 G33, L6, F1, S24 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation OMG XHD Fastener with Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate secured at a rate of 1 per 6.00-ft2 (See Appendix A- Induction Weld Patterns) DL60 Induction welded to each insulation plate -45 (Lim. 7) S-W-6 G33, L6, F1, S24 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation OMG XHD Fastener with Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate secured at a rate of 1 per 4.00-ft2 (See Appendix A- Induction Weld Patterns) DL or DT Induction welded to each insulation plate -52.5 (Lim. 7) S-W-7 G33, L6, P, S24 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation OMG XHD Fastener with Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate secured at a rate of 1 per 4.00-ft2 (See Appendix A- Induction Weld Patterns) DL or DT Induction welded to each insulation plate -52.5 (Lim. 7) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 30 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Induction Welded Assemblies over Steel Deck (New, Existing, or Recover) System No. Deck Detail Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) S-W-8 G33, L6, F1, S12 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation Duro-Bond #15 secured 6-inch o.c. in rows spaced 72-inches o.c. DL or DT Induction welded to each insulation plate -52.5 (Lim. 7) S-W-9 G33, L6, F1, S12 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation Duro-Bond #15 secured 6-inch o.c. in rows spaced 96-inches o.c. DL60 Induction welded to each insulation plate -52.5 (Lim. 7) S-W-10 G33, L6, F1, S24 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation OMG XHD Fastener with Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate secured at a rate of 1 per 3.00-ft2 (See Appendix A- Induction Weld Patterns) DL or DT Induction welded to each insulation plate -75 (Lim. 7) S-W-11 G33, L6, P, S24 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation OMG XHD Fastener with Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate secured at a rate of 1 per 3.00-ft2 (See Appendix A- Induction Weld Patterns) DL or DT Induction welded to each insulation plate -75 (Lim. 7) S-W-12 G33, L6, F1, S12 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation Duro-Bond #15 secured 6-inch o.c. in rows spaced 48-inches o.c. DL or DT Induction welded to each insulation plate -82.5 (Lim. 7) S-W-13 G33, L6, F1, S12 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation Duro-Bond #15 secured 6-inch o.c. in rows spaced 60-inches o.c. DL60 Induction welded to each insulation plate -82.5 (Lim. 7) S-W-14 G33, L6, F1, S12 OPTIONAL Approved Insulation Secured with Top Layer Approved Insulation Duro-Bond #15 secured 6-inch o.c. in rows spaced 48-inches o.c. DL60 Induction welded to each insulation plate -90 (Lim. 7) Assemblies with All Layers Adhered over Wood Deck (New or Existing) System No. Deck Detail Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) W-A-1 T19/32, L32, 0.113-6/6 II-H DG-CR Applied in spatter at a rate of 4.6 lbs/100ft2 Min. 0.5-inch Continuus ReWall Closed Loop Roof Cover Board DG-CR Applied in spatter at a rate of 4.6 lbs/100ft2 DF or DFP WB II -30 (Lim. 9; Non- HVHZ) W-A-2 T15/32, L24, 0.113-6/6 - - DXC DG-CR Applied in spatter at a rate of 6.8 lbs/100ft2 DL or DT WB II or SB IV -75 (Lim. 9; Non- HVHZ) W-A-3 T15/32, L24, 0.113-6/6 - - DXC DG-CR Applied in spatter at a rate of 6.8 lbs/100ft2 DF or DFP WB II or CR-20 -75 (Lim. 9; Non- HVHZ) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 31 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Assemblies with All Layers Adhered over Wood Deck (New or Existing) System No. Deck Detail Base Layer Insulation Base Insulation Attachment Top Layer Insulation Top Insulation Attachment Membrane Attachment MDP (psf) W-A-4 T19/32, L32, 0.113-6/6 - - DXF DG-CR Applied in spatter at a rate of 6.6 lbs/100ft2 DL or DT WB II or SB IV -97.5 (Lim. 9; Non- HVHZ) W-A-5 T19/32, L32, 0.113-6/6 - - DXF DG-CR Applied in spatter at a rate of 6.6 lbs/100ft2 DF or DFP WB II or CR-20 -97.5 (Lim. 9; Non- HVHZ) Assemblies with Adhered Membranes over Wood Deck (New, Existing, or Recover) System No. Deck Detail Base Insulation Top Insulation Insulation Attachment Membrane Attachment MDP (psf) W-AM-1 T19/32, L24, 0.113-6/6 OPTIONAL Approved Insulation DXF DL Plates & #15 Fasteners secured at a rate of 16 per 4 ft x 8 ft board DL or DT WB II or SB IV -52.5 (Lim. 7) W-AM-2 T19/32, L24, 0.113-6/6 OPTIONAL Approved Insulation DXF DL Plates & #15 Fasteners secured at a rate of 16 per 4 ft x 8 ft board DF or DFP WB II -52.5 (Lim. 7) W-AM-3 T19/32, L24, 0.113-6/6 OPTIONAL Approved Insulation DXF DL Plates & #15 Fasteners secured at a rate of 16 per 4 ft x 8 ft board DF or DFP CR-20 -60 (Lim. 7) W-AM-4 T19/32, L24, 0.113-6/6 OPTIONAL Approved Insulation DXF DL Plates & #15 Fasteners secured at a rate of 18 per 4 ft x 8 ft board DL or DT WB II or SB IV -62.5 (Lim. 7) W-AM-5 T19/32, L24, 0.113-6/6 OPTIONAL Approved Insulation DXF DL Plates & #15 Fasteners secured at a rate of 18 per 4 ft x 8 ft board DF or DFP WB II -62.5 (Lim. 7) W-AM-6 T19/32, L24, 0.113-6/6 OPTIONAL Approved Insulation DXF DL Plates & #15 Fasteners secured at a rate of 18 per 4 ft x 8 ft board DF or DFP CR-20 -75 (Lim. 7) Mechanically Fastened Assemblies over Wood Deck (New, Existing, or Recover) System No. Deck Detail Thermal Barrier Insulation Insulation Attachment Membrane Membrane Attachment MDP (psf) W-M-1 T15/32, L24, 0.113-6/6 As required Min. 0.5-inch Approved Insulation Preliminarily secured DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 6-inch wide laps spaced 54-inch o.c -30 (Lim. 7; Non- HVHZ) W-M-2 T15/32, L24, 0.113-6/6 As required Min. 0.5-inch Approved Insulation Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 3-inch wide tabs spaced 60-inch o.c. -30 (Lim. 7; Non- HVHZ) W-M-3 T19/32, L24, 0.113-6/6 As required OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #14 HD Fastener and Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. within 6-inch wide tabs spaced 120-inch o.c. -37.5 (Lim. 7; Non- HVHZ) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 32 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Assemblies over Wood Deck (New, Existing, or Recover) System No. Deck Detail Thermal Barrier Insulation Insulation Attachment Membrane Membrane Attachment MDP (psf) W-M-4 T19/32, L32, 0.113-6/6 As required OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates fastened 6-inch o.c. within 6-inch wide tabs spaced 120-inch o.c. -45 (Lim. 7) W-M-5 T19/32, L32, 0.113-6/6 As required Approved Insulation Preliminarily secured DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates fastened 12-inch o.c. within 6-inch wide laps spaced 54-inch o.c -45 (Lim. 7) W-M-6 T19/32, L24, 0.113-6/6 As required Min. 0.5-inch Approved Insulation Preliminarily secured DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. within 6-inch wide laps spaced 114-inch o.c.; fastener centered 2-inches from edge of tab -45 (Lim. 7) W-M-7 T19/32, L32, 0.113-6/6 As required Approved Insulation Preliminarily secured DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates fastened 6-inch o.c. within 6-inch wide laps spaced 114-inch o.c -52.5 (Lim. 7) W-M-8 T19/32, L24, Hex-12/12 As required OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #14 HD Fastener and Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. into wood truss within 6-inch wide tabs spaced 120-inch o.c. (Min. 2.5-inch penetration into wood truss) -52.5 (Lim. 7) W-M-9 T19/32, L24, 0.113-6/6 As required Min. 0.5-inch Approved Insulation Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. within 3-inch wide tabs spaced 60-inch o.c. -52.5 (Lim. 7) W-M-10 T19/32, L32, 0.113-6/6 As required OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates fastened 6-inch o.c. within 3-inch wide tabs spaced 60-inch o.c. -52.5 (Lim. 7) W-M-11 T19/32, L24, 8d-6/6 As required Min. 1.5-inch Approved Insulation Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Cleat Plates fastened 6-inch o.c. within 6-inch wide tabs spaced 57-inch o.c. (Screws located 2.7-inches from tab edge) -52.5 (Lim. 7) W-M-12 T19/32, L24, 8d-6/6 As required Min. 1.5-inch Approved Insulation Preliminarily secured DL Duro-Last #14 HD Fastener and Duro-Last 3-inch Metal Plates fastened 6-inch o.c. within center of 6-inch wide tabs spaced 57-inch o.c. Tab Sealer 4725 applied at 60 ft2/gal. -52.5 (Lim. 7) W-M-13 T19/32, L24, 0.113-6/6 As required Min. 0.5-inch Approved Insulation Preliminarily secured DL Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. within 6-inch wide tabs spaced 120-inch o.c. -60 (Lim. 7) W-M-14 T19/32, L32, 0.113-6/6 As required OPTIONAL Approved Insulation Preliminarily secured DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Poly-Plates fastened 6-inch o.c. within 6-inch wide laps spaced 54-inch o.c -60 (Lim. 7) W-M-15 T19/32, L24, 0.113-6/6 As required Min. 0.5-inch Approved Insulation Preliminarily secured DT Duro-Last #15 Extra Heavy Duty Drill Point Fastener and Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. within 6-inch wide laps spaced 54-inch o.c.; fastener centered 1.25-inches from edge of tab -67.5 (Lim. 7) A CREEK Technical Services, LLC DLR12001.15 FL16039-R15 Page 33 of 33 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recom mended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Assemblies over Wood Deck (New, Existing, or Recover) System No. Deck Detail Thermal Barrier Insulation Insulation Attachment Membrane Membrane Attachment MDP (psf) W-M-16 T19/32, L24, Hex-12/12 As required OPTIONAL Approved Insulation Preliminarily secured DL Duro-Last #14 HD Fastener and Duro-Last Cleat Plates fastened 6-inch o.c. into wood truss within center of 6-inch wide tabs spaced 120-inch o.c. (Min. 2.5-inch penetration into truss). Tab Sealer 4725 applied at 60 ft2/gal. -82.5 (Lim. 7) Induction Welded Assemblies over Wood Deck (New, Existing, or Recover) System No. Deck Detail Thermal Barrier Insulation Insulation or Thermal Barrier Attachment Membrane Membrane Attachment MDP (psf) W-W-1 T19/32, L24, 0.113-12/6 As required Approved Insulation Duro-Bond through-fastened to wood truss 12-inch o.c. in 6-ft spaced rows DL60 Induction welded to each insulation plate -37.5 (Lim. 7; Non- HVHZ) W-W-2 T19/32, L24, 0.113-12/6 As required Approved Insulation Duro-Bond through-fastened to wood truss 18-inch o.c.in 4-ft spaced rows DL60 Induction welded to each insulation plate -37.5 (Lim. 7; Non- HVHZ) W-W-3 T19/32, L24, 0.113-6/6 As required OPTIONAL Approved Insulation Duro-Bond #15 fastened at a rate of 1 per 4.00-ft2 (See Appendix A - Induction Weld Patterns) DL or DT Induction welded to each insulation plate -45 (Lim. 7) W-W-4 T19/32, L24, 0.113-12/6 As required Approved Insulation Duro-Bond through-fastened to wood truss 12-inch o.c. in 4-ft spaced rows DL60 Induction welded to each insulation plate -52.5 (Lim. 7) W-W-5 T19/32, L24, 0.113-12/6 As required Approved Insulation Duro-Bond through-fastened to wood truss 6-inch o.c. in 8-ft spaced rows DL60 Induction welded to each insulation plate -60 (Lim. 7) W-W-6 T19/32, L24, 0.113-12/6 As required Approved Insulation Duro-Bond through-fastened to wood truss 6-inch o.c. in 6-ft spaced rows DL60 Induction welded to each insulation plate -60 (Lim. 7) W-W-7 T19/32, L24, 0.113-12/6 As required Approved Insulation Duro-Bond through-fastened to wood truss at a rate of 12 per 4 ft x 8 ft board DL or DT Induction welded to each insulation plate -60 (Lim. 7) W-W-8 T19/32, L24, 0.113-12/6 As required Approved Insulation Duro-Bond through-fastened to wood truss at a rate of 16 per 4 ft x 8 ft board DL or DT Induction welded to each insulation plate -90 (Lim. 7) END OF REPORT