Loading...
HomeMy WebLinkAbout143853- Leeward Quail Run WC[2]PROJECT #: DATE: BUILDING SPECIFICATIONS2 PROJECT INFORMATION DIMENSIONS (ft):14 x 20 PROJECT: Quail Run HEIGHT (ft):24 ADDRESS:9440 Meadowood Dr MIN. PARAPET HEIGHT (in):36+CITY, STATE ZIP: Ft Pierce, FL AREA: Main DESIGN CONDITIONS BUILDING USE:commercial WIND SPEED (mph): ENCLOSURE CLASS.:Enclosed Building EXPOSURE CATEGORY:Exposure C RISK CATEGORY:Risk Category II ELEVATION (ft): VELOCITY PRESSURE (q h = 0.00256 * K h * K zt * K e * K d * V 2 ) VELOCITY PRESSURE COEFFICIENT (Kz): TOPOGRAPHIC FACTOR (Kzt): GROUND ELEVATION FACTOR (Ke): WIND DIRECTIONALITY FACTOR (Kd): WIND SPEED (V2): IMPORTANCE FACTOR (I): VELOCITY PRESSURE (qh): DESIGN WIND PRESSURE COEFFICIENTS INTERNAL PRESSURE COEFFICIENT (Gcpi): EXTERNAL PRESSURE COEFFICIENT (GCp): DESIGN WIND PRESSURE (p=q(GC p ) - q i (GC pi )(psf)) ULTIMATE DESIGN UPLIFT PRESSURES: NOMINAL (ASD) DESIGN UPLIFT PRESSURES (0.6 * p): SAFETY DESIGN PRESSURES (FACTOR OF 2): ASSEMBLY SUMMARY Duro‐Last 50 mil Membrane, Adhered, with SB Adhesive, over Securock® Glass‐Mat 1/4‐Inch, Adhered, with CR‐20 Adhesive, over ISO II, 4' x 8' boards, Adhered, with CR‐20 Adhesive, over Structural Concrete Deck Zone 1: NOTES:Adhered pull testing required. Peel Stop req. 24‐36" from exterior edges. INSULATION BEAD SPACING: Performed by Darrell Morris Leeward Roofing CONTRACTOR INFORMATION WIND PRESSURE CALCULATION FL ASCE 7-10 143853 4/9/2020 N/A 0.94 156 24336.00 N/A 49.63 1.00 1.00 0.85 0.18 Zone 1 Zone 2 Zone 3 ROOF ZONES -1.00 -1.80 -1.80 ROOF ZONES (psf) Zone 1 Zone 2 Zone 3 -58.56 -98.26 -98.26 70.27 117.92 117.92 -35.14 -58.96 -58.96 Assembly Re-Roof MDP Report ID Assembly # Limitation ‐60 FL16039‐R15 C‐A‐1 9 ROOF ZONES Zone 1 Zone 2 Zone 3 ADHERED PULL TEST: ¹ Not Reported 12" o.c. 6 per 4' x 8' 6 per 4' x 8' Based on Chapter 30 (Sections 1 & 3) of the American Society of Civil Engineers (ASCE) Standard ASCE 7-10, Minimum Design Loads for Buildings and other Structures. Page 1 of 3 2 These calculations have been done in accordance with ASCE 7 (05, 10 or 16) standards. However, these calculations do not take precedence over local building codes. All calculations on this report are based on information provided by the contractor. Calculations cannot be relied upon should any of the provided information prove to be inaccurate. 1 If estimated, verify and sign for these calcs to be permitted. PERIMETER WIDTH (ft): 5.00' PROJECT #: DATE: Performed by Darrell Morris ASCE 7-10 ROOF ZONE CONFIGURATION 143853 4/9/2020 L x W (ft) =14 x 20 Height (ft) =24 Drawing is not to scale. Used as an example to provide dimensions for reference. DIMENSIONS Page 2 of 35.00'5.00' a = 40% of the bldg height or 10% of the shortest building dimension, whichever is less. Minimum of 5' PROJECT #: ASCE 7-10 DATE: RAS 137 - MEMBRANE ATTACHMENT CALCULATIONS RAS 117 - INSULATION ATTACHMENT CALCULATIONS Performed by Darrell Morris MDP Report ID Assembly # Limitation ENHANCEMENT CALCULATIONS 143853 4/9/2020 TESTED ASSEMBLY INFORMATION ‐‐ ‐ ‐ ZONE 1 ‐60 FL16039‐R15 C‐A‐19 Required SF per  Fastener for Zone: 0.00 Sq. Ft. Fastener Value: ‐‐ ‐ ‐ Zones 2 and 3 are being prescriptively enhanced. #DIV/0! #DIV/0! 0 Zone 2 Max. Fastener  Spacing: #DIV/0! Zone 3 Max Fastener  Spacing: Page 3 of 4 Zone 2 Min. Fasteners  per 4' x 8' board: 5 Zone 3 Min. Fasteners  per 4' x 8' board: 15 Note: Tested assembly requires minimum of 12 fasteners per board. 𝑻𝒂𝒃 𝑺𝒑𝒂𝒄𝒊𝒏𝒈 𝒇𝒐𝒓 𝒁𝒐𝒏𝒆 ൈ 𝑭𝒂𝒔𝒕𝒆𝒏𝒆𝒓 𝑺𝒑𝒂𝒄𝒊𝒏𝒈 𝒇𝒐𝒓 𝒁𝒐𝒏𝒆 𝟏𝟒𝟒 #DIV/0!ൌ ൌ 𝑹𝒆𝒒𝒖𝒊𝒓𝒆𝒅 𝑺𝑭 𝒑𝒆𝒓 𝑭𝒂𝒔𝒕𝒆𝒏𝒆𝒓 𝒇𝒐𝒓 𝒁𝒐𝒏𝒆 ൈ 𝑴𝑫𝑷 𝒐𝒇 𝑻𝒆𝒔𝒕𝒆𝒅 𝑨𝒔𝒔𝒆𝒎𝒃𝒍𝒚 0 60 𝑭𝒂𝒔𝒕𝒆𝒏𝒆𝒓 𝑽𝒂𝒍𝒖𝒆 ൈ 𝟏𝟒𝟒 𝒁𝒐𝒏𝒆 𝟐 𝑫𝒆𝒔𝒊𝒈𝒏 𝑷𝒓𝒆𝒔𝒔𝒖𝒓𝒆 ൈ 𝑻𝒂𝒃 𝑺𝒑𝒂𝒄𝒊𝒏𝒈 0 -58.96 ൌ ൌ 𝑭𝒂𝒔𝒕𝒆𝒏𝒆𝒓 𝑽𝒂𝒍𝒖𝒆 ൈ 𝟏𝟒𝟒 𝒁𝒐𝒏𝒆 𝟑 𝑫𝒆𝒔𝒊𝒈𝒏 𝑷𝒓𝒆𝒔𝒔𝒖𝒓𝒆 ൈ 𝑻𝒂𝒃 𝑺𝒑𝒂𝒄𝒊𝒏𝒈 0 -58.96 𝑲𝒏𝒐𝒘𝒏 #𝒐𝒇 𝑭𝒂𝒔𝒕𝒆𝒏𝒆𝒓𝒔 𝒑𝒆𝒓 𝑩𝒐𝒂𝒓𝒅 𝒇𝒐𝒓 𝒁𝒐𝒏𝒆 𝑴𝑫𝑷 𝒐𝒇 𝑻𝒆𝒔𝒕𝒆𝒅 𝑨𝒔𝒔𝒆𝒎𝒃𝒍𝒚ൌ 𝑼𝒏𝒌𝒏𝒐𝒘𝒏 # 𝒐𝒇 𝑭𝒂𝒔𝒕𝒆𝒏𝒆𝒓𝒔 ሺ𝑿ሻ 𝒁𝒐𝒏𝒆 𝟐 𝑫𝒆𝒔𝒊𝒈𝒏 𝑷𝒓𝒆𝒔𝒔𝒖𝒓𝒆 ሺ𝑵𝒐𝒎𝒊𝒏𝒂𝒍ሻ 12 -60 -58.96 𝑲𝒏𝒐𝒘𝒏 #𝒐𝒇 𝑭𝒂𝒔𝒕𝒆𝒏𝒆𝒓𝒔 𝒑𝒆𝒓 𝑩𝒐𝒂𝒓𝒅 𝒇𝒐𝒓 𝒁𝒐𝒏𝒆 𝑴𝑫𝑷 𝒐𝒇 𝑻𝒆𝒔𝒕𝒆𝒅 𝑨𝒔𝒔𝒆𝒎𝒃𝒍𝒚ൌ 𝑼𝒏𝒌𝒏𝒐𝒘𝒏 # 𝒐𝒇 𝑭𝒂𝒔𝒕𝒆𝒏𝒆𝒓𝒔 ሺ𝑿ሻ 𝒁𝒐𝒏𝒆 𝟑 𝑫𝒆𝒔𝒊𝒈𝒏 𝑷𝒓𝒆𝒔𝒔𝒖𝒓𝒆 ሺ𝑵𝒐𝒎𝒊𝒏𝒂𝒍ሻ 12 -60 -58.96