Loading...
HomeMy WebLinkAbout003 A003 ADA COMPLIANCESTROBE EQ EQ (WHERE OCCURS) SIGNAGE (WHERE OCCURS) T-STAT (WHERE OCCURS) - - - LIGHT SWITCH (TO ALIGN WITH - - - - - DOOR LEVER) Q - (WHERE OCCURS) -U 0 0 - o 00 \ N CD Q� � z \ cn �Oco0) w _Of N ELECTRIC/DATA 00 (WHERE OCCURS) o TYPICAL MOUNTING HEIGHTS NOTE: 1. ALL MOUNTING HEIGHTS ARE TYPICAL UNLESS NOTED ON INTERIOR ELEVATIONS 2. ALL MOUNTING HEIGHTS TO CONFORM WITH ALL LOCAL, STATE, AND FEDERAL CODES. 3. NOT ALL TOILET ACCESSORIES LISTED ARE INCLUDED IN THIS CONTRACT. SEE FLOOR PLANS AND INTERIOR DESIGN DOCUMENTS, FOR REQUIRED TOILET ACCESSORIES. 4. ALL DIMENSIONS ARE CLEAR TO FINISH MATERIALS. COORDINATE ALL MOUNTING HEIGHTS AND CLEAR DIMENSIONS. WITH I.D. DOCUMENTS AND DIMENSIONAL CONTROL PLANS. BRING ANY CONFLICTS TO THE ARCHITECTS ATTENTION IN A TIMELY MANNER. 7'-6" MIN. CLEAR 60" CLEAR lo 17" 12" 24" MIN. I MIN. J Z U :2t Z_ Z ME N O COORDINATE MINIMUM CLEAR DIMENSION WITH WIDTH OF SPECIFIED LAVATORY. 15" MIN. 30"X48" CLEAR FLOOR SPACE AT LAVATORY SHALL COMPLY WITH 11-4. 19.3 OF FBC 2017 \ Z ANY AMOUNT 4" MAX. w m O 0:�Cn o 00 i� N O Z / Q w = m m o w = NY AMOUN REQUIRED CLEARANCES OF PROTRUDING OBJECTS CANE DETECTION 56" MIN. CLEAR WALL MTD. TOILET 59" MIN. CLEAR FLOOR MTD. TOILET 4" MAX. � =Qw I H a (n I Q 42" MIN. 42" MIN. LATCH APPROACH ' 48" MIN. ALL 54" tv I � I OTHER APPROACHES II ' II PLUMBING FIXTURE CLEARANCES (STALL) STANDARD REQUIRED STALL TYPICAL REQUIRED ACCESSIBLE STALLS I 3F" fAIN ROLL -IN SHOWER WITH FOLDING SEAT J3" MAX 3F" (`1 FAR 36" MIN. 56" MIN. CLEAR WALL MTD. TOILET 101 59" MIN. CLEAR FLOOR MTD. TOILET 54" MIN. 42" MIN. I I I I O Z U I z I N \ Is \ \ I z \ I N \ i 12" 36" MIN. 12" STANDARD REQUIRED STALL OPTION (FOR END STALL OF STALL ROW) N GROUP BATHROOMS 6" MAX. 27" MAX. 6" MAX. M M z M w w� p p o I I I I F I I I I z I I I I I I - LAV. I 60" MIN. , WHERE A SEAT IS PROVIDED, GRAB BARS SHALL NOT BE PROVIDED ABOVE THE SEAT. SHOWER SIZE AND CLEARANCES NOTE: ALL DIMENSION SHOWN ARE TO WALL TY P . REQUIRED CLEARANCES AT SHOWERS FINISH. GC TO ALLOW TO 2" AROUND THE CRITICAL ROOMS FOR ALL L WALL FINISHES AS SHOWN ON ID FINISH SCHEDULE 22» SHOWER SEAT DESIGN 48" MIN. X Q 00 WALL OR POST MOUNTED PAY TELEPHONE (MOUNTED ACCORDING TO HIGHEST OPERABLE PART) WALL MOUNTED SOAP DISPENSER WALL MOUNTED D CHANGING STATIC ALLOWABLE REACH RANGE FROM SIDE APPROACH (ONLY IF POSSIBLE) * ALL MAXIMUM MOUNTING HEIGHTS TO BE TAKEN FROM FLOOR TO HIGHEST OPERABLE- PART (COIN SLOTS, HANDLES, ETC.) OF EACH ACCESSORY ACCESSORIES NOTE: ALL DIMENSION SHOWN ARE TO WALL FINISH. NOTE: DOOR MUST SWING 54" MIN. OUT AND BE SELF 42" MIN. , 12" CLOSING 1�7 w J 42" MIN. LATCH APPROACH OTHER APPROACHES 66" MIN. CLEAR WALL MTD. TOILET 69" MIN. CLEAR FLOOR MTD. TOILET REQUIRED AMBULATORY ACCESS STALL (IF 6 OR MORE STALLS ARE PROVIDED - INCLUDING ACCESSIBLE STALLS) FINISHED WALL SURFACE Z_ MIN. Z z 0-) 16" MIN / 18" MAX. 30"X48" CLEAR FLOOR SPACE PAPER TOWEL DISPENSER SANITARY NAPKIN DISPENSER TOILET SEAT COVER DISPENSER ALLOWABLE REACH RANGE FROM FRONT APPROACH Q 00 z COORDINATE MINIMUM CLEAR DIMENSION WITH WIDTH OF 7'-6" MIN. CLEAR SPECIFIED LAVATORY. 60" MIN. FIN. TO LAVATORY 15" MIN. FIN. TO C/L NOTES: PROVIDE 6-0" DIAMETER 401. DIMENSION FROM THE FACE -OF - WHEEL CHAIR TURNING FTNTSH AT ADJACENT SIDE WALL TO SPACE THE CENTERLINE OF THE WATER CLOSET APPLIES TO THE FULL LENGTH / OF THE WATER CLOSET. INSTALL � WATER CLOSETS PARALLEL TO WALL. • yy>< '>X> PROVIDE 30"X48" CLEAR FLOOR SPACE AT LAVATORY 402. IF A 30"X48" CLEAR FLOOR SPACE / TS-PROVIDED BEYOND THE ARC OF / I THE DOOR THEN DOOR SHALL BE / PERMITTED TO SWING INTO THE 1� CLEAR FLOOR SPACE REQUIRED CLEARANCE REQUIRED FOR ANY FOR MANEUVERING CLEARANCE FIXTURE. EACH SIDE OF DOOR 403. PER THE 2010 FGI GUIDELINES FORFDESIGN AND CONSTRUCTION OF HEALTH FACILITIES, PATIENT -USE TOILETS SHALL SWING OUTWARD, AS SHOWN IN OPTION "A", OR BE EQUIPPED WITH EMERGENCY RESCUE 4" MAX. DOOR HARDWARE. 603.2.3 EXCEPTION # 2 TOILET ROOM WITH IN -SWINGING DOOR TYPICAL REQUIRED TOILET ROOM FINISHED WALL 30" SURFACE MIN CLEARANCE EQ. EQ. URINAL SCREEN SHOWN SHADED I I I I I I I I I I I I I I I I I I z I I � I I I I � I I � I I li I I I I I I I 11 11" 6„ 6"MAX MIN MI . 17" t 1/2" MIN. MIN LAVATORY URINAL 30" MIN CLEARANCE EQ. EQ. 19" MIN WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES OR SINKS. — FINISHED WALL SURFACE 6" MAX. 36" MIN. 12" 24" MIN. 10 MIN. 17" It. Q C/ 7 U LL z d C m M CD CD 01 17' MIN. TOILET �1►1�y71��l�i�1:1�1 SURFACE 01 54" MIN. 12" 42" MIN. MAX IC1ll�a��19�:� 36" MAX. DISPENSER w U Cn O LZ Z Li Z ¢0_ r �CD 0 NOTE: CONTROL FOR FLUSH VALVES SHALL COMPLY (FBC 604.6) TY P . MOUNTING HEIGHTS - R E S T RO O M S 18° FROM WISH WALL SURFACE 0 36" CLEAR FROSH WALL SURFACE 18" CONTROL AREA MOUNTED ON WALL OPPOSITE SEAT w �w 0 w w N wLLJ 0 U ¢ ¢ w p O Q M Q C1 Q X (n Z X 00 NCD o� 00 LLJ o CD J = CD 0 CD 0 0 o SEAT TO EXTEND FULL DEPTH OF STALL. MOUNT ON WALL OPPOSITE OF CONTROLS SHOWER STALL (36" x 36") architecture planning interiors sparcdesign Jupiter Commerce Park 3021 Jupiter Park Circle Suite 102 Jupiter, FL 33458 t 561.203.7539 www.sparcdesign.us OF F� PN••SU *% O coo �, y co U '' o Q AR97488 v N a /sTFRED ARG�� Q W C4 Digitally signed by Sean Sean Sukhu i Sukhu, R.A. AR97488 R.A. AR97488 Date:0 0�04000 This item has been electronically signed and sealed by Sean Sukhu, R.A. on the date and/or time stamp shown using a digital signature Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. © 2020 Sun Patrick Architecture, INC. This Document is an instrument of service and the property of Sun Patrick Architecture, INC. AA26003806 and shall remain their property. This document is not suitable for use on other projects or in other locations. Publication is expressly limited to the original site for which it was prepared. � mZ V=W V Q�V a �o W�� (DW- O — " _Z� , W=)V wo< V =D U LU 002 a CL aa� Q J PROJECT ISSUE DATES: 2020.03.27 ISSUED FOR BID/PERMIT SHEET NAME ADA COMPLIANCE Project Number: 2019.137 DATE: 2020.03.27 SHEET NUMBER A003