Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
004 A100 DEMOLITION PLAN
O O� i0 00 O O O- O O 00 O O- O O F17 O N "X --------------------- \ ---------------- C0 X" Y/ / / Y,a c b.U1 0 0 \ 0 \ 0 \ U *0 U \ U 0 F0 \ 3JN3J ANI� NIbHJ L U -'1 I I I I I I I I i 1 I I 1 ` - O O 1 D. i C '' , 1 / / i i i Ln DEMOLITION CONTRACTOR SHALL COORDINATE ALL ACTIVITIES WITH THE GENERAL CONTRACTOR. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND DEMOLITION CONTRACTOR TO THOROUGHLY REVIEW THE SITE CONDITIONS AND EXISTING BUILDINGS AND COORDINATE PHASING OF THE WORK SO AS NOT TO INTERRUPT UTILITY SERVICES UNLESS APPROVED BY THE OWNER. NOT ALL SUBSURFACE CONDITIONS ARE KNOWN HOWEVER FOOTINGS AND FOUNDATIONS OF THE EXISTING BUILDINGS SHALL BE REMOVED IN THEIR ENTIRETY. COORDINATE THE REMOVAL OF THE TEMPORARY FACILITIES STRUCTURES AND TEMPORARY UTILITTIES WITH THE OWNER. COORDINATE DEMOLITION WITH THE OWNERS SCHEDULED ACTIVITIES AND THE CONTINUED USE OF THE ADJACENT DOG PARK 1 GENERAL 01.01 NOT USED 2 SITEWORK REFER TO CIVIL DRAWINGS FOR EXTENT OF SITE DEMOLITION 02.01 EXISTING SEPTIC TANK AND DRAIN FIELD TO REMAIN 3 CONCRETE 03.01 REMOVE EXISTING CONCRETE SLAB / EQUIPMENT PAD. 03.03 EXISTING CONCRETE EQUIPMENT PAD TO REMAIN 03.05 NOT USED 03.07 NOT USED 5 METALS 05.01 EXISTING FENCE AT DOG PARK ENTRY/SURROUND TO REMAIN. 05.09 EXISTING GATE TO REMAIN. 05.11 EXISTING ALUMINUM SLIDING GATE TO REMAIN. 6 WOODS + PLASTIC 06.01 REMOVE EXISTING WOOD POWER POLES 06.03 REMOVE EXISTING WOOD DECK, FOUNDATIONS, STAIRS, RAMPS AND RAILS IN THEIR ENTIRETY. ROUGH GRADE SITE AFTER DEMOLITION 06.05 REMOVE EXISTING WOOD DECK, FOUNDATIONS, RAMPS AND RAILS AS INDICATED ON DEMOLITION PLAN. REFER TO NEW DECK PLANS FOR EXTENT OF NEW CONSTRUCTION. CONTRACTOR TO COORDINATE REMOVAL WITH INTENT OF NEW CONSTRUCTION. 6.07 EXISTING WOOD DECK, FOUNDATIONS, STAIRS, RAMPS TO REMAIN 7 THERMAL + MOISTURE PROTECTION 07.01 NOT USED 8 DOORS + WINDOWS 08.01 NOT USED 9 FINISHES 09.01 NOT USED 10 SPECIALTIES 10.01 NOT USED 11 EQUIPMENT 11.01 NOT USED 13 SPECIAL CONSTRUCTION 13.01 NOT USED 14 CONVEYING SYSTEMS 15 14.01 NOT USED MECHANICAL, PLUMBING 15.01 NOT USED 16 ELECTRICAL 16.01 REMOVE EXISTING ELECTRICAL SERVICE LINES. CONDUIT AND POLES. BACK TO EXISTING TRANSFORMER. O 16.03 TERMINATE EXISTING DATA CONDUIT AND LINES IN UNDERGROUND ELECTRICAL BOX. REMOVE EXISTING LINE FROM BUILDING TO \ POINT OF TERMINATION. \�/ 16.05 NOT USED 16.07 REMOVE EXISTING ELECTRICAL PANEL. TURN OVER TO OWNER C 16.09 REMOVE EXISTING SITE LIGHTING. TURN OVER TO OWNER 16.11 EXISTING SPRINKLER CONTROL PANEL TO REMAIN. SPRINKLER ZONES TO REMAIN ACTIVE DURING CONSTRUCTION. CAP ABANDONED ZONES AFFECTED BY CONSTRUCTION. COORDINATE WORK WITH OWNER. / 16.13 EXISTING ELECTRICAL SERVICE TO BE CONNECTED TO TEMPORARY POWER DURING CONSTRUCTION. 16.15 REMOVE ELECTRICAL PANEL. RE -FEED DOG PARK CIRCUITS FOR POWER AND LIGHTING DURING DEMOLITION. REFER TO ELECTRICAL. DEMOLITION LEGEND EXISTING WORK TO REMAIN ASPHALT AND BASE REMOVAL 5 EXISTING WORK TO BE REMOVED SITE OF BUILDING DEMOLITION SITE OF FUTURE BUILDING CONCRETE PAVERS. REMOVE AND STORE FOR LATER INSTALLATION O® CONCRETE SLAB CUTS _ DEMOLITION TAGS NOTE: OWNER SHALL REMOVE ALL OWNER FURNISHINGS/APPLIANCES FOR STORAGE PRIOR TO DEMOLITION. * NOTE: CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND REVIEW ALL DOCUMENTS TO COORDINATE THE NEW WORK DOCUMENT QUALIFICATION THIS DRAWING WAS EXCERPTED FROM BOUNDARY SURVEY DOCUMENTS PREPARED BY MASTERLLER & MOLLER, INC. DATED May 8th, 2019 FOR THE SPECIFIC PURPOSES OF THIS PROJECT. USE WITHOUT VERIFICATION WILL BE AT THE USER'S SOLE RISK. THE USER SHALL INDEMNIFY THE ARCHITECT SUN PATRICK ARCHITECTS INC., FROM ALL CLAIMS AND LOSSES RESULTING FROM SUCH USE. THE DELIVERY OF THIS DRAWING TO THE USER SHOULD NOT BE CONSTRUED TO PROVIDE AN EXPRESS WARRANTY OR A GUARANTEE TO ANYONE THAT CERTAIN CONDITIONS EXIST OR THAT THE USE OF THIS DRAWING IMPLIES THE REVIEW AND THE APPROVAL BY THE ARCHITECT OF ANY SHOP DRAWING BASED ON THIS INFORMATION. USE OF THIS DRAWING IN NO WAY RELIEVES ANY OTHER PARTY FROM MEETING REQUIREMENTS IMPOSED BY CONTRACT OR OTHER MEANS. 5fsparcdesigrn architecture planning interiors sparcdesign Jupiter Commerce Park 3021 Jupiter Park Circle Suite 102 Jupiter, FL 33458 t 561.203.7539 www.sparcdesign.us OF F- h ��P� PN.•SU�J/� O V_ coo �, y ao U o AR97488 v N a /sTFRED ARG�� a W t/N Digitally signed by Sean Sukhu, Sean Sukhu, R.A. AR97488 R.A. AR97488 Date:2020.03.30 16:40:41-04'00' This item has been electronically signed and sealed by Sean Sukhu, R.A. on the date and/or time stamp shown using a digital signature Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. © 2020 Sun Patrick Architecture, INC. This Document is an instrument of service and the property of Sun Patrick Architecture, INC. AA26003806 and shall remain their property. This document is not suitable for use on other projects or in other locations. Publication is expressly limited to the original site for which it was prepared. W LU VFZ W a�V a �V o W>-� O°C> o ~- � Z W=)V wo< V =D U LU :* Ooo a =Zv; CL Q = Q J PROJECT ISSUE DATES: 2020.03.27 ISSUED FOR BID/PERMIT SHEET NAME DEMOLITION PLAN Project Number: 2019.137 DATE: 2020.03.27 SHEET NUMBER