Loading...
HomeMy WebLinkAboutBuxton A-1 signed2811 1x .16 .03' 45,306 s.f. (1.04 Ac.) turn Building Coverage Allowed: (20%) 9,058 s.f, ig residence: 2,419 s.f. sed Guesthouse: 1,526 s.f. Building Coverage: 3,945 s.f. (11. %) SETBACKS BUILDING C AREA CALCULATIONS Front: 50' Rear: 30' Sides: 20' Ok A ..ILIc. Volume: 9,582 C f. lum Guesthouse Allowed: <2,41 9 s.f. s.f. Guest louse Provided. (5.9% of rnax. building coverage, the mix, building coverage allowed agars lg as it does not Main blouse sqare = )t ge. Safe Load Table dotes 1. All values based on minimum 4" nominal bearing. Exception: Safe loads for unfilled U lintels must be reduced by 20% if bearing length is less than 6 1 /2". 2. N.R. = Not Rated 3. Safe loads are superimposed allowable loads. 4. One #7 rebar may be substituted for two #5 rebar in 8 inch U lintels only. 5. All safe loads in units of pounds per linier foot. 6. All safe loads are based on simply supported span. 7. Safe load ratings based on rational design analysis per ACI 318 and ACI 530. Composite U Lintel rt 1r1�.tel aterials 1. Grout per ASTM C476 fg=3000 psi with maximum 3/8 inch aggregate and 8 to 11 inch slump. 2. Rebar per ASTM A615 Grade 60 3. Concrete masonry units (CMU) per ASTM C90 with minimum net area compressive strength = 1900 psi 4. Mortar per ASTM C270 Type M or S #5 rebar at top mdn.(I reg4 quanity of #5 rebar CV 1--- at bottom of lintel cavity r F= filed grout nominal '- -0� width � C.M. \ E �eut <> F 6---1 / 1 T reinforced CastCrete lintel 7 ebar at bottom nominal J quanrebar a of #5 I cavity heigth rebar at top O" Nominal Lintel Type Designation In ftaliaton Notes 1. Installation of U lintels must comply with architectural and/or structural drawings. 2. U lintels can be field cut to the required length. 3. Cast in place concrete may be provided in composite U lintel in lieu of concrete masonry units. 4. The exterior surface of U lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 5. Concrete masonry units used in composite U lintel shall be laid in a running bond. 6. Shore composite lintels as required. 7. U lintels are manufactured with a 5 1 /2r" long notch at both ends to accomodate vertical cell reinforcing and grout. in Cast Crete Lintel Schedule Floor Pla- All Rebar to be #5 Grade 60 min. MARK LENGTH OF LINTEL ALLOWABLE GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT LOAD BEAM SPECS. L-1 4'-6- 6113 864 2724 601 8F16-1B/1T L-2 3'-8- 6113 550 3079 215 8F16-1B/1T L-3 6'-8- 3120 509 1651 202 8RF14-1B/1T L-4 T-8"" 4360 120 2093 95 8F16-1 B/1 T L-5 4'-8- 4567 381 1960 115 8RF14-1B/1T L-6 14'-10- 1250 226 485 156 8F16-1B/1T L-7 12'-0" 1254 463 723 365 8F16-1 B/1 T L-8 T-8- 1845 637 1133 253 8F16-1B/1T L-9 5'-0" 5365 157 2290 143 8F16-1B/1T Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Insulation Flame Spread: Not to exceed 25 Insulation Smoke Developed Index: Not to exceed 450 Wall Finishes: Not greater than 200 Ceiling Finishes: Not greater than 200 R20 Spray Foam Insul. O 8'-1 „ OL T.O.B. 1 /2- d.w 1 x 4 p.t. Firest.op Two Course Perimeter Beam with (1) #5 Rebar in each course, Filled with Grout 1 x 2 p.t. furring strips 24"o.c.--, with R4.1 Foil insulation 1 /2„ d. #5 Vert. rebar in grout filled cell See Floor Plan For Locations 11! 1Conc. on i Compacted, F.F.E. 0 Project Data Project: Buxton residence Street Address: T.B.D. PierceCity: Ft. County: St. Lucie State: Florida -,..),cope, of kNork New one 'level CBS single family residence 5V Roof Panels over 30# Felt, on 19/32" C.d.x. plywood fastened as per nailing schedule Pre Engineered Wood Roof Trusses 24-o.c. Shop Drawings by Others 12 Q5 (2) #5 Rebar 1 '-6„ See Connector Schedule Galv. Drip Edge over 1 x 3 p.t. 2 x 6 Cedar Fascia Board Stucco Soffit Over 2'-0" High Ribbed Wire Lath Use 8 x 16 screen vents at non insulated areas Install one layer of 15# felt to framing prior to installing wire lath 8x16x8 CMU Tye. Light Textured Stucco Finish #5 Vert. Rebar with 10- Hook and 30" Lap. Tie to Vert. Rebar In Cells I Ty 'cal Wall S'eduon Roof Live [_..pad: 20.0 p.s.f. Floor Live Loa&. N.A. Wind Speed: 160 MPH Wind Importance Factor: 1.0 Building Category: II Wind Exposure: C Internal Pressure Coefficent: .18 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. PRODUCT APPROVAL Approval Glass Building Rated Product Rated Product Model Number Manufacturer Attachment Method Number Type Design Pressures Design Pressures Head: 12" max. from corners & 30`"o.c. max. Jambs: SH-5500 12` max. from corners & 17.7 max. 5" each side of FL: 239.7 Windows Singlehung PGT Industries Impact meeting rail. Use 3/16- Tapcon with 1 1/4", embedment +33.5 -44.8 i +/- 50.0 into concrete Glazed 6°" from corners and 3"& 7"`each side of center at head & FL#: 17184.2 Swing Doors Fiberglass I Plastpro Impact sill and 6""from corners & 14 1 /4"max. o.c. at jambs. +33.5 -36.3 +/- 50.0 Door 1 /4" tapcon screws with 1 1 /4- embed. into conc. 6- from corners & 14-o.c. at jambs, head, sill. 1 /4" tapcon FL#: 17184.5 Swing Doors Fiberglass Plastpro screws with 1 1/4" embed. into conc. Impact +33.5 -36.3 + 65.0 -70.0 (Inswing) Door +/- 65.0 (Outswing) Approval i Product Model Number Manufacturer Attachment Method Building Rated Product Rated Number Design Pressures Design Pressures FL: 17443.1 Roafing 5V Crimp JA Taylor Roofing #9-15 x 1 `" coorosion resistant screw with sealing washer at each rib 12"o.c. in field and 6"o.c. along perimeter. -45.0 -69.25 LFL: 9777.7 Roofing Underlayment _ Weatherlock Specialty Owens Cornin g Direct attachment to plywood deck -45.0 -142.5 CL iearo LLI " 2 L 01 r CID L..i CU �0 a b LIJ 00 00 0 U- U cn LL z LLJ C) _ 0 U) LLI 0 i) drawn s.l. checked s.l. date 7/5/2020 scale as noted job number 20025 sheet 1 4' Roof Wind Zones scale: 1 /8- = 1'-0" 3/8- continuous bead of caulk (back bedding) behind — buck to prevent liquid passage set flange in continuous bead of caulk across the entire face of buck bQ C o-0 CD 0 c 1 � 0' o.c J o (n B W C 0 0C o�aU) 00 i o C = aUmra Cl) G stucco finish J� perimeter caulk Attach p.t. bucks with 8d coil nails at 12-o.c. Typ. Alum. window . jamb or sliding glass door jamb Min. 1 1 /4" embedment at windows and min. 1 1 /2- embedment at sl. gl. doors 1 /2- drywall 1 /4" max. struct. shim caulk attach as per manufacturers product approvals NOTE: Method of attachment and Gunable sealants shall comply with waterproofing procedures are the ASTM C 920 Class 25 grade or same at poured concrete sill. greater for proper joint expansion and contraction Coat Bucks with Protecto LWM200 Waterproofing after they have been installed and Chaulked Window & Door Flashing Detail at CBS Wall Includes Buck Attachment Method Wind Zones - Walls Alum. window frame -, 3/8" continuous bead of caulk (back bedding) behind shim to prevent liquid passage 1 /4" struct. shi set flange in continuous bead of caulk across the entire face of buck 2 " ; 0.00, ,--F.F_E. perimeter caulk stucco finish Protecto LWM200 Coating on Outside face and Janbs of Openings all Sides min. 8 precast J conc. sill bN r Top of Be to Soffit ,m I !� ❑ �� ill Front Elevation scale: 1/4- = 1'-0" corrosive resistant Tapcon concrete srews installed as specified in window manufacturers product approval window sill Gunable sealants shall comply with ASTM C 920 Class 25 grade or greater for proper joint expansion and contraction Typical Precast Conc. Sill Detail Coat Bucks with Protecto LWM200 Waterproofing after they have been installed and Chaulked Bottom Cord of Truss 2 x 4 top plate 1 /2" gyp. d.w. 2 x 4 studs 2411o.c. No. 3 Stud Grade 2 x 4 p.t. sill plate wood base Cased Hard Coil Nails 12"o.c. max. Concrete Foundation Interior Wall Section corner bars at beam (outside only) (2) corner bars at footing (min.) — vert. dowel lapped with wall reinforcing, all laps 30" (min.) in grout filled cell Rear Elevation scale: 1 /4" = 1'-0" 0 O N all comer bars to be the same size, number, and spacing as horizontial bars in footing, beams, and walls Corner Reinforcing Detail Left Elevation scale: 1/4" = 1'-0" Right Elevation scale: 1 /4- = 1'-0" U a p Q� N 00 L. r3 W Z � CV)�..J U- In bLO — to W ai i �r cI u7 00 ® —I if N (/) Q � Z U U W > ° _J W X M qt A>, W �♦�^ VJ > LO uO 0 tV r T J o Z 1-11 U Q UJ W 04 o% CU 0o W T— t'L O LL a UJ 0 U m (.� Z W >; W O () (u U UJ J co 0 O . �. f) U drawn S.I. checked S.I. date 7/6/2020 scale as noted job number 20025 sheet A-2 11 0 I M C izI ON U 52'-0" 38'-8„ 7,_8„ 5'-8„ 5'-5" 3'-10"` _ 4'-0°" 4,-0`° 3,_0 T-3`" 3'-5" 1 `10'" 6'-0°" 1'-10`° 2'-4" X-C 2'-4`° 4'-4" 16„ 0 o f-1 o a F_1 011 4-2500# o cone. pad N -4- F-1 F T 0 o a F-1 I a a o F_1 a NEI I I F �----- _----__ ------- — �— IF-5 CIO I I in I -4°` I I ® I------� F-5 F-1 o 0 o u I F-4 I ❑ 3,-0„ 14,_0„ I 6'-4`° o ❑ I I la T o I I N I❑ o M it I F_1 4"" 3000# FIBERMIX CONC. I o I I OVER .006 VAPOR BARRIER I I -J ON CLEAN, COMPACTED, p I TERMITE TREATED FILL C1 I ASSUMED F.F.E. 0.00' I I IF-5 IF-1 I ❑ I I I T T I I ❑ i M I I I 4"` 2500# I I conc. pad— . . . . . .. .. ❑ ❑ ❑ ❑ F-1 ❑ ❑ ❑❑ ❑❑ . ❑ F-1 ❑ ❑o F-1 Ali,. I I F-1 o F-1 _ C o U> •. F-1 •• T 3'-10"` 3'-3" 3'-2"` 3'-10"" 1 4'-11 "` 12"1 4'-0" 112" 17`" T-0"" 1 2'-11 22'-8„ 6,-0„ 11,_4„ 10'-8„ 116-1 40'-0" 12'_0„ Foundation & Footing Plan scale: 1/4" = 1'-0" �lo�-I-rir+�l Clan scale. I/'t - t -V Meter F-1 F-4 F-5 Recess 4" at Shower 18" x 16" mono. footing 8"" with (2) #5 rebar cont. 18" x 16" mono. footing see plan with (2) #5 rebar coot. 16" L8_16" 4„ 4„ 18" 18" . 18" TYP. SHOWER MONO. EDGE FOOTING RECESS INTERIOR STEP FOOTING GENERAL FOUNDATION NOTES Concrete shall be a minimum of 4" thick over clean, compacted, termite treated fill and 6 mil polyethylene vapor barrier. If concrete slab contains 6" x 6" 10/10 WWM provide 1" coverage Concrete shall have at minimum compressive strength of not less than 3,000 p.s.i. All 90% hooks are to be extended 10" minimum beyond the turn. Field bends are to be done cold and the diameter of the bend, measured on the inside of the bar, is not to be less than six bar diameters. Minimum coverage for rebar shall be 3"° in footings and 1 1 /2" in bond beams. Hooks may be rotated horizonitally if required to achieve minimum coverages. Rebar overlap shall be 48 bar diameters. 30" for #5 rebar The foundation design assumes that the soil has a minimum load carrying capacity of 2000 p.s.f. In the event the soil bearing capacity falls below 2000 p.s.f. This foundation plan may be superceded by Foundation Design Engineer. Satisfactory compaction test of fill does not verify lower soils are adequate. All specifications and dimensions to be verified by contractor. All exterior slabs shall slope a minimum 1 /8" per foot for drainage PLUMBING NOTES: No structural concrete shall be stripped until it has reached at least 80% of the 28 day design strength. Design, Erection, & Removal of all formwork, shores, & reshores shall meet meet the ACI Standards 347 and 301 Contractor to verify all building setbacks prior to the start of construction. A formboard survey shall be submitted to the building department for approval prior to pouring concrete. SOIL STATEMENT: Foundation has been designed for a soil bearing capacity of 2000 p.s.i. Fill shall be laid in layers of 6". Each layer to be compacted to 95% compaction. If the contractor encounters, while digging the foundation, any discrepancy to suggest the soil may be inadecuate, he must immediately report it to the owner and the Architect or Engineer so as to order a soil boring test. Dowel Rod Repair Note In the event vertical steel has been omitted from the down pour locations, drill 5" into concrete (no closer than 3 3/4" from edges and 5" from ends of cap walls) Remove dust per manufacturers instructions and use Two part epoxy to anchor the #5 rebar in place. Use either °°Hilti C-100" or Simpson Epoxy -Tie. Plumber to consult with contractor and equipment ordered for rough in dimensions. Verify all dimensions with the floor plan. The floor plan dimensions dictates all other dimensions on other sheets. Do not scale drawings, if any conflicts arise, contact the Architect or Engineer for clarification prior to construction. All sanitary lines 2" or less shall have a slope of 1 /4- per foot minimum. All sanitary lines above 2" shall have a slope of 1 /8j" per foot minimum. Provide Anti -Scalding Valve in all showers. Lowest living area floor elevation (refered as 0.00') to be set by a professional land surveyor to the required building department elevation, but not less than 18- above the crown of the road. Electrical Load Calculations 1182 Living S.F. at 3 VA 3546 watts One 20 Amp Appliance Ckts. 1500 watts Two Laundry Cir. @ 1500 watts 3000 watts One Range 8000 watts One Dishwasher & One Disposal @ 1500 watts each 3000 watts One Microwave @ 2000 watts 2000 watts One Dryer @ 5 kw 5000 watts Two Ref. 1500 watts Two Baths @ 1500 watts each 3000 watts Total 30,546 watts (3) #4/0 (THW) copper First 10 KVA at 100% 10,000 watts and (1) #2 ground (THW) Wall Remainder at 40°10 8,218 watts copper in 2 galy. conduit Total 18,218 watts One AC Heat at 100% 10,000 watts Total 37,024 watts Panel: 200 A.M.C.B. 200 Amp �\ 1,6, 3W 40 Circuit Panel ( M ) 28,218 W / 240 V = 117.6 Amps 120/240 Volt Use 200A Service a.c. disc. (3) #4/0 (THW) copper and (1) #2 ground (THW) copper in 2 galy. conduit 5/8" dia. x 10'-0" F.P.L. service long ground rod 3/4" copper water pipe , a M1 tie ground wire to footing rebars Electrical Riser Diagram to sewer system Plumbing contractor to provide a water hammer & shut off valve at each fixture Insulate all hot water lines s • •SMIM , •. M ELECTRICAL LEDGEND 2" v.t.r. j0 RECESSED LIGHT WITH LENS 4 EXTERIOR & WET LOCATIONS -E} SURFACE MOUNTED LIGHT FIXTURE TT�-----�---� SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE CEILING FAN WITH LIGHT OPTION 0 CARBON MONOXIDE SMOKE DETECTOR COMBO. EXHAUST FAN OUTLET DOOR CHIMES DUPLEX OUTLET -}► TELEVISION 220 V OUTLET -Q SWITCH TELEPHONE -yj- THREE WAY SWITCH PUSH BUTTON 3W NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46- A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS OWNER TO CORRDINATE LOCATIONS OF TELEPHONES AND TELEVISIONS IN FIELD WITH CONTRACTOR Smoke detectors wired to 120V Bathroom lights Non Switchable, Non GFI Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified Electrical Notes 1. All loads to be checked by a Florida Licensed Electrician 2. All work to meet the National Electrical Code 3. Calculations and panels below are for sizing conduit and overall building load requirements only 4. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box for exterior lights on building; AC, MC, or EMT conduit elsewhere. 5. Ensure min. 36`° clear between equipment and disconnects, Typical. V U [1: N 00 �.. W z M LLLL LO w CO U.) 0000 --I LL N (� Q U � W > 0 J {n LO W cr_ M d' 4-) V ) s N� > LLJ CU LO LO • ,� O CU ,— r (D 00 O Z 04 3 � cWi� t� < 00 T 0 LL. O +J .p W U � L>` Z >: '-' o W C) W J 4) c E (/7 0 CAI drawn S.I. checked s.l. date 7/6/2020 scale as noted job number 20025 sheet A-3 Ceramic Tile Shall be installed in accordance with ANSI A108.1, A108.4, A108.5 A108.6, A108.11, A118.1, A118.3, A136.1, & A137.1. Fiber mat reinforced backer shall be used behind wall applied ceramic tiles in the tub and shower areas and conform to ASTM C1325. Per Durock, cement board exceeds ASTM C 1325. Gypsum Note Gypsum board shall conform to ASTM C22, C475, C514, C1002, C1047 C1177, C1178, C1278, C1396, or C1658 and installed per FBC residential code. Per USG, Wallboard conforms to C1396. Gypsum Board & Gypsum Panel Products Gypsum board and gypsum panel products shall be applied at right angles or parallel to framing members. All edges and ends of gypsum board and gypsum panel products shall occur on framing members, except those edges and ends that are perpendicular to the framing members. Interior gypsum board shall not be installed where it is directly exposed to weather or to water. Wall and ceiling gypsum board shall be fastened with screws spaced at 12""o,c. Screws for attaching gypsum board and gypsum panel products to wood framing shall be Type W or Type S in accordance with ASTM C1002 andshall penetrate thewood not less than 5/8"" inch (15.9mm) Gypsum board and Gypsum panel products shall be attached to cold formed steel framing less than 0.033" 0 mm) thick shall be Type S in accordance with ASTM C1002 or bugle head style in accordance with ASTM C1513 and shall penetrate the steel not less than 3/8" to 0.112- (1 mm to 3mm) thick shall be in accordance with ASTM C954 or bugle head style in accordance with ASTM 1513. Screws for attaching gypsum board or gypsum panel products to structural insulated panles shall penetrate the wood structural panle facing not less than 7/16"o.c. 0 1. 1 mm). Gypsum board used as the base orbacker for adhesive application of ceramic tile or other required nonabsorbent finish material shall conform to ASTM C1396, C1178, C1278. Use of water resistant gypsum backing board shall be permitted on ceilings. Water resistant gypsum board shall not be installed over a Class 1 or Class 2 vapor retarder in a shower or tub compartment. Cut or exposed edges, including those at wall intersections, shall be sealed as recommended by the manufactuer. Water resistant gypsum backing board shall not be used where there will be direct exposure to water, or areas subject to continuous high humidity. Cold Formed Steel Note Cold formed steel framing supporting gypsum board and gypsum panel products shall be not less than 1 1 /4" (32mm) wide in the least dimension. Non Load bearing cold formed steel framing shall comply with AISI S220 and ASTM C645, Section 10. Load bearing cold formed steel framing shall comply with AISI S200 and ASTM C955, Section 8. Wood Framing Note Wood framing supporting gypsum board and gypsum panel products shall be not less than 2" (51 mm) nominal thickness in th least dimension except that wood furring strips not less than 1" by 2" (25mm x 51 mm) nominal dimension shall be permitted to be used over solid backing or framing spaced not more than 24"o.c. (610mm) Over wood framing the paper backed wire lath shall be installed over one layer of approved plastic house wrap. Lath shall be attached horizontal framing members with 1.5" roofing nails and to vertical wood framing members with 6d common nails or 1 " roofing nails driven to penetration of not less then 3/4" of an inch, or 1 itwire staples driven flush with the plaster base. Staples shall have crowns not less than 3/4" and shall engage not less than three strands of lath and penetrate the wood framing members not less than 3/4". The fasteners must penetrate the wood framing members not less than 3/4". Fasteners shall be 7" O.C. max. EXTERIOR CEILING & SOFFIT NOTE 7/8" Stucco finish over 3/8" high ribbed galy. wire lath fastened to framing members with No. 11 guage nails with 1 3/4"" embed. with 3/8" dia. head 6"o.c. max. edges to be tied and nailed at 9""o.c. Install one layer of 15# felt to framing prior to installing ribbed lath INTERIOR WALL FRAMING NOTE Interior non bearing walls to be 2 x 4 studs 24""o.c. Spruce, Pine, Fir (SPF) #3 Grade lumber or better or metal studs (25 Ga.) Crimper may be used in lieu of screws. BUCK ATTACHMENT NOTES AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH TO BLOCK WITH 1 /4" DIA. TAPCONS INTO C.B.S. SET AT 6" FROM CORNERS AND AT 12"o.c. MAX. AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS OR "T"" NAILS" 4" FROM ENDS AND 12-o.c. USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION STRUCTURAL NOTES: All reinforcing steel shall be high strength billet steel and shall conform to ASTM A-615 grade 60 specifications. Lap continuous reinforcing 48 bar diameters or 30"" in beams and in slabs. Lap bottom steel over supports and top steel at midspan. Hook discontinuous ends of all top bars. Reinforcing steel shall have a minimum of 1 " concrete cover, or as follows: BOTTOM TOP SIDES Beams: 1 1/2- 1 1/2" 1 1/2- Slab on Grade: 1 1/2- 1" _ Structural Poured: 3/4"" 3/4" Poured Walls: _ — 3/4" Slabs exposed to the weather 3/4" 1 Reinforcing steel shall be detailed and fabricated in accordance with the ""Manual of Standard Practice of Detailing Reinforcing Concrete Structures" and the current "ACI Building Code 318- All structural steel shall conform to current ASTM Specification A-36 All wood in contact with masonry shall be pressure treated or approved seperating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. No slump over 5"" shall be permitted for any structural concrete without the Architect or Engineer approval. All Design and Construction shall be inaccordance with the current American Concrete Institute (ACI). and the American Institute of Steel Construction (AISC), The Florida Building Code and all applicable local codes. Structural Concrete shall attain a minimum ultimate compressive strength (Fc') in 28 days as follows: Column Footing and Wall Footing: 3000 p.s.i. Column and walls from foundation to roof. see column schedule. All other concrete: 3000 p.s.i. Footing sizes and reinforcing are based on allowable soil bearing capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this is not the case, the Architect or Engineer shall be notified before proceeding with the work. Timber (Heavy Timber Construction) (a) Truss manufacturer shall submit a signed and sealed shop drawings by a registered Engineer. (b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i. (c) Roof members should be secured to the beams or other structural components with hurricane anchors for wind uplift. All wood members shall have a minimum fiber stress in bending of 1200 p.s.i. with 1 /360 max. deflection. All bolted connections shall be 1/2- Cadmium plated or better. Lag bolts to be used only in shear connections with minimum 4" threaded penetration past steel plate. Lag bolted conditions shall be drill tapped no larger than the internal thread diameter and shall not be hammer driven. Under Girder Trusses provide equal number of studs as girder plys at frame bearing locations GENERAL REQUIREMENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project., unless explicitly identified here. Owner is responsible for all municipal related charges such as impact fees, and water connection, except building permit fees, which are to be included in the construction bid. General contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and ommissions are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors method or means of construction. General contractor is to keep the site in a clean and safe state through out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. All plans and drawings are not considered complete until they have been reviewed and approved by the St. Lucie County Building Department and the building permit has been issued. SHEATHING NAILING NOTES Nailing Pattern Zone 1: 8d at 6"o.c. field & 4"o.c. edges Zone 2: 8d at 4"o.c. edges & field Zone 3: 8d at 4"o.c. edges & field Pneumatic Nails Pneumatic or mechanicaly driven nails will be accepted under the following conditions: Min. nails size 8d or larger ring shank with Min. shank diameter:.113 Min. Length: 2" Min. Head Diameter:.280 Full Round Min. Ring Diameter .012 over shank dia. Min. 16 to 20 Rings per Inch Note Gun nails shall be permitted as an acceptable fastener from any manufacturer Nailing Schedule ROOF & FLOOR DIAGRAM Use sheathing with #8 gun nails at 6"o.c. at supported panel edges and #8 gun nails at 6"o.c. at intermediate supports. ROOF SHEATHING TO GABLE END FRAME Use #8 gun nails at 4"o.c. EXTERIOR SHEATHING Use #8 gun nails at 4"o.c. at panel edges and #8 gun nails at 4"o.c. at panel top and bottom and 6"o.c. in field w J1 J3 J5 J7 J7 J7 J7 J7 w w J7 J7 J7 J5 J3 J1 Missed Tie Down Strap Note In the event the Tie Down Strap has been omitted from the Layout location, install one HTSM20 strap at the proper location. Fasten with (4) 1 /4"" x 2 1 /4"" Hex Head Titen screw to C.B.S. and 00) 10d to truss. MAXIMUM UPLIFT 1175 lbs. GENERAL ROOFING NOTES Roofing to be composed of and attached to pre manufactured wood trusses as follows: Felt underlayment (min. ASTM 0 226 Type II) with 4" min. side and end laps, fasten with coorosion resistant annular ring shank nails at 6""o.c. in laps and in staggered rows spaced 12""o.c. in field. If roof pitch is < 4/12 install (2) layers 15# felt. If roof pitch is 4/12 or greater, install (1) layer 30# felt. 19/32" c.d.x, sheathing or equal installed with staggered joints nailed to trusses with 8d corrosion resistant annular ring shank nails spaced max. 6"o.c. throughout, except max. 4-o.c. at gable ends. All roof trusses are to be pre -manufactured assemblies provided by a licensed wood truss fabricator with seperate drawings and data prepared for actual project conditions by a Florida registered professional engineer certified for truss design. Any deviation from the proposed plans as shown regarding placement or bearing shall be brought to the attention of the truss engineer prior to fabrication of the trusses. The truss manufacturer's certified layout shall govern after fabrication. The handling, erection, and fixing of wood trusses shall be in accordance with the specifications contained on the certified mfgr's. drawings and data. All engineered headers and truss hangers to be provided by the truss manufacturer. Wood screws meeting the same size requirement may be used in lieu of nails without comment Splitting or cracking of structural components due to installation of THRESHOLD NOTE hardware is not permitted. At egress door (see floor plan) the max. hgth. Unless otherwise noted, the installation of specified hardware shall conform to the truss manufacturers installation instructions and of the threshold shall be 1/2" standard practice. 38'8" 52' u u 2218" 6' 11'4" 12' Connector Schedule Truss Bearing Truss Connector Qnty Connector Fasteners Point Uplift ID Uplift APh CBS 1804 HETA20 1 1810 (9) 10d x 1 1/2- Wall HHETAI6 1 2235 (10) 10d x 1 1/2" M 3269 (8) 8d x 1 1/2" and (2) A13 Htos 1 1065 3/8"x 4""Titen HD to 1 Ply CBS G 1715 HETA20 1 1810 (9) 10d x 1 1/2" All other trusses ALL <1000 MTS18 1 1000# 04) 10d x 1 1/2" to Frame All other trusses ALL <1810 HETA20 1 1810# (9) 10d x 1 1/2" to CBS Supporting (4) 10d Valley Framing <250# VTCR 1 370# valley (3) 10d x 1 1/2" Trusses Truss Connector Notes: Do not substitute connectors Do not sheath trusses before all straps are in place Attach valley trusses and piggy back trusses, if present, to main trusses per truss manufacturer drawing. Truss to truss connection by truss company, installed per manufacturers specs. Lateral forces perpendicular and parallel to wall has been considered (less than 300 p.l.f.) Contractor to approve temporary bracing to prevent toppling of trusses, see HI13-9. Other specs, if different from above, have priority. A.T.R. = All Treaded Rod Drill and Epoxy Set all A.T.R. Use either "Hilti" C-100 or Simpson Epoxy Tie Epoxy 2 x 4 bottom cord bracine Attic Vents Calculation CARPORT & ENTRY AREAS Attic Area: 344 s.f. / 150 = 2.3 s.f. required. soffit area = 80.7 l.f. x 2.0 = 161 s.f. Venting Provided: 8 x 16 soffit vent: 85 sq. in. each vent 6 Vents along overhang = 510 sq. in. 510sq.in. / 144=3.5s.f. Total Ventilation Provided: 3.5 sq. ft. 5'8" -- -� 10'-0`" CL 00 fY O W 01 Z IL in V) w LO 00 hl ..�. Q Gj to Z 0- o Z w 4) O 0 � u7 W � 4) 4J cu N Q N CCU v / W LO co LO C�V D 1! C T p� I.,, `V 00 _ U o z UJ OD T >o 1 O C U- O +J .� W X.p U � LL Z LU >; 0 N o UJ J � 0 co J E O D U drawn S.I. checked s.l. date 7/6/2020 scale as noted job number 20025 sheet A-4