Loading...
HomeMy WebLinkAboutBUXTON RES.-LAYOUT0 0 N a LOT 283.11 x 160.03 457306 s.f. (1.04 AC,) SETBACKS BUILDING AREA CALCULATIONS Project Data ZONING: AR-1 Front: 50' Living: 1182 Project: Buxton residence Street Address: T.B.D. Maximum Building Coverage Allowed: (20%) 9,058 s.f. Rear: 30' Carport: 314 City: Ft. Pierce Existing Residence: 2,419 s.f. Sides: 20' Entry: 30 County: St. Lucie Proposed Guesthouse: 1,526 s.f. Total: 1526 State: Florida Total Building Coverage: 3,945 s.f. (11,4%) Scope of Work Maximum Guesthouse Allowed: <27419 s.f. 1,526 s.f. Guesthouse Provided. (5.9% of max. building coverage) 35% of the max. building coverage allowed along as it does not exceed Main House square footage. U p � � 25 s.h. ; wh Egress i I �—, I I C7jCCCX II Ref w , _ -4"" '-4"�- 3 _" 13 " 51 I -8"13' 00 \ ic) x "" ( 1 logxO�i� 8'-1 Cing. d I —I dW I o Master Bdrm E Kitchen I N N 8'-1"" Ceiling 8'-1 Ceiling ( N Oin ,SprO o I I 6'-10"" 3'-00" 3'-2"" 0"" 3'-4" 6 3'-0"" 2'-6"" 1 9'-0"" 4' 6'-4"" I 25 s.h. I Q I Egress 10ktOX L--- -- P. N O I -8 I = � t — Carport Cing. from j from F.F.E. I I2Y Y7 1 22" 361 0 M IA` ass Living Room Bedroom 2 Bedroom 3 �_ 8'-1" o iling 8'-1" Ceiling 8'-1" Ceiling c o t ®t I 9'-10" 10'-0 " 2' "" 15'-8LL= I I I I 25 s.h. 25 s.h. i (2) 25 Egress Egress s.h. CD M E.; o 8'-1 "" Cing. from F.F.E. -- -- N 5'-7"" Floor Plan 10'-3"" 6'-10" 6'-5"" New one level CBS single family residence R30 Batt Insulation Wind Building Code U 6th Edition Florida Building Code: Residential 2014 National Electric Code NFPA 70 Q N Design Loads o w oo M Roof Live Load: 20.0 p.s.f. 0Z Floor Live Load: N.A. LL LO Wind Speed: 160 MPH b4A cn ai Importance Factor: 1.0 - N W Building Category: 11 0 it co Wind Exposure: C Internal Pressure Coefficent: '18 0 —I L Structure Designed: Enclosed — Q a) Soil bearing capacity: 2000 p.s_f. F- it o C Z tr. l'.l 0 MOON0 > J X O W M 5V Roof Panels Q) over 30# Felt on Mimi 19/32"c.d.x. plywood fastened () as per nailing schedule Pre Engineered Wood Roof Trusses 24""o.c. Shop Drawings by Others See Connector Schedule 12 Galy. Drip Edge Q 5 � over 1 x 3 p.t. 1/2" d.w. 1 x 4 Firestop 2 x 6 Cedar Fascia Board Vented Two Course Perimeter 2'-0"" Stucco Soffit Over Beam with (1) #5 Rebar High Ribbed Wire in each course, Filled Lath with Grout Install one layer of 15# felt to framing prior to installing wire lath 1 x 2 p.t. furring strips 24"o.c. with R4.1 Foil insulation 8 x 16 x 8 CMU Typ. 1 /2" d. . Light Textured #5 vert. rebar in Stucco Finish grout filled cell O C: See Floor Plan LL Q a for Locations +J w X SOW O U m li z >; 2500# Fibermix Conc. #5 Vert. Rebar with W 4CJ: on .006 Vapor Bearier on 10" Hook and 30" 0 :5 Clean, Compacted, Termite Lap. Tie to Vert. -- U O U Treated Fill Rebar In Cells fn CU uJ N J @ � U coCD J M E C4/j) O samms F.F.E. L�7 v� f— Grade = \\ U (2) #5 Rebar Typical Wall Section dravm checked sl. date 5/1/2020 scale as noted job number 20025 sheet A-1