HomeMy WebLinkAboutCurrent - Titanium PSU 30 - Cover Sheet„ MIt
Profe5Sional Regulation
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge Stats & Facts Publications I Contact Us I BCIS Site Map Links I Search
bProduct
r Approval
`r s USER: Public User
Product Approval Menu > Product or Application Search > Application Checklist > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL11602-R9
Revision
2017
Approved
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43645
(740)321-6345
Greg. Keeler@owenscorning.com
Keeler Greg
Greg.Keeler@owenscorning.com
Greg Keeler
2790 Columbus Road
Granville, OH 43023
(740)321-6345
greg.keeler@owenscorning.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
Intertek Testing Services NA, Inc. - QA Entity
12/31/2020
John W. Knezevich, PE
f Validation Checklist - Hardcopy Received
FL11602 R9 COI 2019 01 COI NIEMINEN.pdf
Standard
Year
ASTM D1970
2015
ASTM D226 (physicals)
2009
ASTM D4798
2011
FRSA/TRI April 2012
2012
TAS 117(B)
1995
UL1897
2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
08/15/2019
08/15/2019
08/21/2019
10/15/2019
�unuual Y v1 V1 UUUILD
FL # Model, Number or Name Description
11602.1 Titanium Roof Underlayments Synthetic sheet -type roof underlayments
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-45
Other: 1.) The design pressure noted herein pertains to use of a
specific underlayment system beneath foam -on tile sytsems. Refer
to ER Section 5.6.3 for details. 2.) Refer to ER Sections 5 and 6 for
other Limits of Use.
Installation Instructions
FL11602 R9 II 2019 08 FINAL ER FL11602-R9.pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL11602 R9 AE 2019 08 FINAL ER FL11602-119.12-df
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe