HomeMy WebLinkAboutRevised DrawingsCOPYRIGHTCNOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF FLORIDA ALUMINUM ENGINEERING, INC.
PROJECT ADDRESS:
D
R
A
W
N
B
Y
D
A
T
E
D
R
A
W
N
R
E
V
I
S
I
O
N
1
2
S
H
E
E
T
N
O
:
3
4 PROFESSIONAL ENGINEER
THOMAS P. ARNETT, P.E.
LICENSE No. #46043
5601 MARINER STREET SUITE 240
TAMPA FL. 33609
TEL: (813) 374-2403
FAX: (813) 374-4516
FLORIDA LICENSE: CA LIC. NO. 32807
FLORIDA ALUMINUM
ENGINEERING, INC.
L
I
C
E
N
S
E
T
H
O
M
A
S
P
.
A
R
N
E
T
T
P
R
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
ER
F
L
O
R
I
D
A
T
h
i
s
i
t
e
m
h
a
s
b
e
e
n
e
l
e
c
t
r
o
n
i
c
a
l
l
y
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
b
y
T
.
P
.
A
r
n
e
t
t
,
P
E
.
u
s
i
n
g
a
D
i
g
i
t
a
l
S
i
g
n
a
t
u
r
e
w
i
t
h
d
a
t
e
a
n
d
t
i
m
e
.
P
r
i
n
t
e
d
c
o
p
i
e
s
o
f
t
h
i
s
d
o
c
u
m
e
n
t
a
r
e
n
o
t
c
o
n
s
i
d
e
r
e
d
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
a
n
d
t
h
e
s
i
g
n
a
t
u
r
e
m
u
s
t
b
e
v
e
r
i
f
i
e
d
o
n
a
n
y
e
l
e
c
t
r
o
n
i
c
c
o
p
i
e
s
.
CONTRACTOR: Master Craft AluminumDESIGN CRITERIA:Applicable Codes, Regulations, and Standards1.The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design,Chapter 20 Aluminum, and Chapter 23 Wood.2.AA ASM 35 and AA ADM1 Specifications for Aluminum Structures, Part 1-A of theAluminum Design Manual prepared by The Aluminum Association. and the AAF Guideto Aluminum Construction in High Wind Areas.3.ASCE 7-10.Loading Criteria1.Live Load: 10 PSF per 6th Edition (2017) Florida Building Code, Appendix I Section105.12.Dead Load: 2 PSF3.Wind Load:3.1.Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1.3.2.Ultimate Design Wind Speed: VULT = 150 MPH, Nominal Design Wind Speed: VASD= 116 MPH3.3.Exposure Category, Section 1609.4.3: Exposure C3.4.Screen Enclosure Section 2002.44.Building Category for Aluminum Structures, Section 2002.6: Category Type 1 - ScreenRoom / Wood Shed: Non-Habitable, UnconditionedScope of Work:Does not include analysis of existing structure.Roof Type1.Roof Type: MONOSLOPE2.Roof Material: 3” x 48” x 0.024” composite panel Elite 2000, 1.0# density foam,Florida Product Approval Number FL 7561-R4.Foundation DesignNew 4" conc. slab w/ fibermesh filled w/ 2,500 PSI concrete. The foundations are basedon a minimum soil bearing pressure of 1,500 psf.SpecificationsThe following specifications are applicable to this project:1.All work shall be in accordance with the 6th Edition (2017) Florida Building Code, andany other applicable local codes and regulations.2.Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, nomanufacturer substitution is acceptable without the specific written, signed and sealedauthorization of Florida Aluminum Engineering, Inc.3.Screen material shall be 18/14 screen unless approved by Florida Aluminum Engineering,Inc.4.Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zincplated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steelseries "400".5.Approved concrete screw anchors to be Simpson Titen-HD or equivalent.6.All Self Mating Beam Sections are to be stitched with either #14 screws 6” from ends and24” center to center or #12 screws 6" from ends and 12" center to center.7.Door location shall be determined by contractor in the field.8.Where concrete specifications are required, whether in the screen enclosure scope or not,by one or more regulatory agency, the following specifications are applicable:a.Concrete shall conform to ASTM C94 for the following components:i.Portland Cement Type 1,- ASTM C 150ii.Aggregates - Large Aggregate 3/4” max - ASTM C 33iii.Air entraining +/- 1% - ASTM C 260iv.Water reducing agent - ASTM C 494v.Clean Potable watervi.Other admixtures not permittedb.Metal accessories shall conform to:i.Reinforcing Bars - ASTM A615, grade 60ii.Welded wire fabric - ASTM A185c.Concrete slump at discharge chute not less than 3” or more than 5”. Water addedafter batching is not permitted.d.Prepare and place concrete per American Concrete Institute Manual of StandardPractice, Parts 1, 2, and 3 including hot weather recommendations.e.Moist cure or polyethylene curing permitted.f.Prior to placing concrete, treat the entire subsurface area for termites in compliancewith the FBC.g.Concrete shall be placed over a polyethylene vapor barrier.h.All aluminum components embedded within concrete shall be coated with abituminous paint or epoxy.9.All lumber and plywood shall have grade marks and treatment identification and Shallconform to the following:a.Framing lumber shall be minimum no. 2 southern yellow pine and have amaximum moisture content of 15%.b.Pressure treatments shall be osmosalts, osmose k-33, womansalts or celcure, asrecommended for the use condition. Pressure treated lumber shall be impregnatedwith a cca salt treatment in accordance with f.s. tt-w-571 and bear the AmericanWood Preservatives Institute quality mark lp-2.c.Wall Sheathing: APA rated Sheathing, thickness as indicated, Exposure 1.d.Aluminum members that are uncoated shall be separated from PT lumber by 30#felt paper, 10 mil polyethylene sheet or equivalent material.10.Contractor shall provide Florida Product Approval information as to the exact windowbeing utilized for this project, including manufacturers specifications, and installationmethods for anchoring the submitted windows to aluminum members and specific sizes asindicated on A-1. Aluminum member thickness to be increased as required by the FloridaProduct Approvals for anchorage of products.11.Contractor shall provide any additional backing (aluminum, wood etc..) and anchorsas required by the window manufacturers recommended procedures.12.All glass panels within 24" of a door opening shall be of tempered glass perFBC-R308.413.All flashing and weatherproofing shall be provided by the contractor.14.Use of these plans acknowledges and accepts a limit of liability not to exceed designand engineering fee.
A
-
1
BOWERS
6563 DULCE REAL AVENUE
FORT PIERCE
FL 34951
T
P
0
7
/
0
1
/
2
0
-
-
-
0
3
/
2
6
/
2
0
WIND SPEED AND EXPOSUR
E
H
A
V
E
BEEN DETERMINED USING
T
H
E
A
D
V
A
N
C
E
D
TECHNOLOGY COUNCIL'S
W
E
B
S
I
T
E
AND GOOGLE EARTH.
2
X
3
T
O
P
R
A
I
L
C
O
N
N
E
C
T
I
O
N
T
O
3
X
3
U
P
R
I
G
H
T
S
C
A
L
E
:
N
T
S
2" x 3"
F
L
A
T
T
O
P
R
A
I
L
-
N
O
ANGLE
R
E
Q
U
I
R
E
D
U
N
L
E
S
S
SP
L
I
C
E
D
O
R
C
O
R
N
E
R
-
ATTA
C
H
w
/
(
4
)
#
1
0
x
4
"
L
G
3
"
x
3
"
x
0
.
0
9
3
"
U
P
R
I
G
H
T
(
5
)
1
/
4
"
x
4
"
L
A
G
S
W
/
1
1
/
4
"
D
I
A
.
N
E
O
P
R
E
N
E
F
A
C
E
D
W
A
S
H
E
R
P
E
R
P
A
N
E
L
(
4
)
#
1
0
x
3
/
4
"
S
M
S
I
N
T
O
S
C
R
E
W
B
O
S
S
E
S
(
2
)
I
N
T
O
T
O
P
R
A
I
L
(
2
)
I
N
T
O
P
O
S
T
2
"
x
2
"
x
3
"
L
G
x
1
/
8
"
A
N
G
L
E
2" x 3
"
F
L
A
T
TOP
R
A
I
L
w
/
(4) #10 x
4
"
S
M
S
INTO
P
O
S
T
(4) #1
0
x
3
/
4
"
SM
S
I
N
T
O
SCREW B
O
S
S
E
S
(2) INTO TO
P
R
A
I
L
(2) INTO
P
O
S
T
2" x 2"
x
3
"
L
G
x 1/8"
A
N
G
L
E
C
O
N
N
E
C
T
I
O
N
A
T
C
O
R
N
E
R
C
O
N
N
E
C
T
I
O
N
A
T
S
P
L
I
C
E
S
A
-
2
3
"
C
O
M
P
O
S
I
T
E
P
A
N
E
L
3" x 0.06
2
"
A
L
U
M
RECEIVING C
H
A
N
N
E
L
W/ #10 x 3/4" T
O
P
A
N
D
BOTTOM AS E
N
D
C
A
P
#
1
4
S
M
S
x
1
"
M
I
N
.
L
O
N
G
E
R
T
H
A
N
P
A
N
E
L
W
/
1
1
/
2
"
D
I
A
.
N
E
O
P
R
E
N
E
F
A
C
E
D
W
A
S
H
E
R
@
1
2
"
O
.
C
.
A
L
O
N
G
L
E
N
G
T
H
O
F
A
L
L
E
N
D
B
E
A
M
S
3
"
C
O
M
P
P
A
N
E
L
END WALL
2
"
x
3
"
F
L
A
T
E
N
D
B
E
A
M
2
"
x
3
"
F
L
A
T
T
O
P
R
A
I
L
W
/
(
4
)
#
1
0
x
4
"
S
M
S
I
N
T
O
P
O
S
T
FRONT WALL
2
"
x
2
"
x
3
"
x
1
/
8
"
A
L
U
M
A
N
G
L
E
E
A
C
H
S
I
D
E
O
F
U
P
R
I
G
H
T
W
/
3
/
8
"
D
I
A
.
x
3
"
C
O
N
C
R
E
T
E
A
N
C
H
O
R
S
O
N
E
A
C
H
S
I
D
E
(
M
I
N
2
3
/
4
"
E
M
B
E
D
.
)
&
(
3
)
#
1
2
x
3
/
4
"
S
M
S
S
C
R
E
W
S
I
N
T
O
T
H
E
P
O
S
T
3
"
x
3
"
P
O
S
T
T
O
D
E
C
K
C
O
N
N
E
C
T
I
O
N
D
E
T
A
I
L
S
S
C
A
L
E
:
N
T
S
B
A
-
2
U
P
R
I
G
H
T
1" x 3"
O
B
A
T
T
A
C
H
E
D
T
O
CON
C
R
E
T
E
W
/
1
/
4
"
D
I
A
.
CONCRET
E
S
C
R
E
W
A
N
C
H
O
R
6
"
F
R
O
M
U
P
R
I
G
H
T
&
A
T
2
4
"
O
.
C
.
(
M
I
N
.
2
3
/
4
"
E
M
B
E
D
.
)
3
x
U
P
R
I
G
H
T
C
H
A
I
R
R
A
I
L
M
E
M
B
E
R
2
"
x
2
"
x
1
/
8
"
A
N
G
L
E
W
/
(
4
)
#
1
0
x
5
/
8
"
E
A
C
H
S
I
D
E
C
H
A
I
R
R
A
I
L
T
O
U
P
R
I
G
H
T
D
E
T
A
I
L
S
C
A
L
E
:
N
T
S
C
A
-
2
1/8" x 2" x 2" EXTRUDEDANGLE 5052 H-32 ALLOYW/ (4) #14 x 3/4" SMSINTO DJUPRIGHT(1) 3/8" DIA. CONCRETESCREW ANCHORS(2 1/4" CONC. EMBED)6"FRONT VIEW SIDE VIEW 2 1/4" MIN CONCANCHOR EMBEDMENTUPRIGHT TO CONCRETE @ PRE-HUNGDOOR LOCATION DETAILSCALE: NTS 1" x 3" BASE PLATEANCHORED TO CONC W/ 1/4"CONCRETE SCREW ANCHOR(MIN. 1 1/4" EMBED)6" MAX EACH SIDE OF POSTAND 24" O.C. MAX SLAB / FOOTINGSEE PLANDJ-1A-2 PRE-HUNGDOOR JAMB
N
O
T
E
:
H
E
A
D
E
R
A
T
T
A
C
H
M
E
N
T
T
O
F
A
S
C
I
A
W
/
1
/
4
"
L
A
G
S
@
2
4
"
O
.
C
.
W
/
1
3
/
4
"
E
M
B
E
D
M
E
N
T
S
-
1
A
-
2
C
O
M
P
.
R
O
O
F
T
O
C
O
R
N
E
R
P
O
S
T
@
4
T
H
W
A
L
L
D
E
T
A
I
L
S
C
A
L
E
:
N
T
S
3
"
x
3
"
x
0
.
0
9
3
"
P
O
S
T
2
"
x
5
"
S
M
B
(
5
)
1
/
4
"
x
4
"
L
A
G
S
W
/
1
1
/
4
"
D
I
A
.
N
E
O
P
R
E
N
E
F
A
C
E
D
W
A
S
H
E
R
P
E
R
P
A
N
E
L
3
"
C
O
M
P
O
S
I
T
E
R
O
O
F
P
A
N
E
L
1
1
/
8
"
x
2
1
/
2
"
x
1
1
/
8
"
x
0
.
1
2
5
"
A
L
U
M
R
E
C
E
I
V
I
N
G
C
H
A
N
N
E
L
W
/
(
3
)
#
1
2
x
3
/
4
"
S
M
S
E
A
C
H
S
I
D
E
O
F
B
E
A
M
&
(
2
)
3
/
8
"
D
I
A
.
T
H
R
U
B
O
L
T
S
I
N
T
O
T
H
E
P
O
S
T
2
"
x
3
"
x
0
.
0
5
0
"
E
N
D
B
E
A
M
3
/
8
"
D
I
A
.
T
H
R
U
B
O
L
T
(
3
T
O
T
A
L
)
#
1
4
S
M
S
x
1
"
M
I
N
.
L
O
N
G
E
R
T
H
A
N
P
A
N
E
L
W
/
1
1
/
2
"
D
I
A
.
N
E
O
P
R
E
N
E
F
A
C
E
D
W
A
S
H
E
R
@
1
2
"
O
.
C
.
A
L
O
N
G
L
E
N
G
T
H
O
F
A
L
L
E
N
D
B
E
A
M
S
E
X
I
S
T
I
N
G
H
O
S
T
F
L
A
S
H
I
N
G
COPYRIGHTCNOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF FLORIDA ALUMINUM ENGINEERING, INC.
PROJECT ADDRESS:
D
R
A
W
N
B
Y
D
A
T
E
D
R
A
W
N
R
E
V
I
S
I
O
N
1
2
S
H
E
E
T
N
O
:
3
4 PROFESSIONAL ENGINEER
THOMAS P. ARNETT, P.E.
LICENSE No. #46043
L I C ENS
ETHOMASP.AR
N
E
T
T
P
R
O
F
E
SSIONAL E N G I N E E R
FLO R I D A5601 MARINER STREET SUITE 240
TAMPA FL. 33609
TEL: (813) 374-2403
FAX: (813) 374-4516
FLORIDA LICENSE: CA LIC. NO. 32807
FLORIDA ALUMINUM
ENGINEERING, INC.
A
-
2
0
6
/
3
0
/
2
0
BOWERS
6563 DULCE REAL AVENUE
FORT PIERCE
FL 34951
T
P
0
3
/
2
6
/
2
0
-
-
-
ALUMINUM MEMBERS DIMENSIONSHOLLOW SECTIONS2 x 2: 2” x 2” x 0.046”2 x 3: 2” x 3” x 0.050”2 x 4: 2” x 4” x 0.050”2 x 5: 2” x 5” x 0.050”OPEN BACK SECTIONS1 x 2: 1” x 2” x 0.040”1 x 3: 1” x 3” x 0.045” SNAP SECTIONS2 x 2 Snap: 2” x 2” x 0.045”2 x 3 Snap: 2” x 3” x 0.050”2 x 4 Snap: 2” x 4” x 0.045”SELF MATING (SMB)2 x 4 SMB: 2” x 4” x 0.044” x 0.100”2 x 5 SMB: 2” x 5” x 0.050” x 0.100”2 x 6 SMB: 2” x 6” x 0.050” x 0.120”2 x 7 SMB: 2” x 7” x 0.057” x 0.120”2 x 8 SMB: 2” x 8” x 0.072” x 0.124”2 x 9 SMB: 2” x 9” x 0.072” x 0.124”2 x 10 SMB: 2” x 10” x 0.092” x 0.398”MINIMUM FASTENER EDGE DISTANCE: 1/2"MINIMUM FASTENER SPACING: 3/4"CONCRETE SCREW ANCHOR:SIMPSON TITEN HD OR EQUIVALENTSHEET METAL SCREWS (SMS):ITW / BUILDEX OR EQUIVALENT
T
Y
P
I
C
A
L
W
O
O
D
F
R
A
M
E
W
A
L
L
@
D
O
O
R
S
E
C
T
I
O
N
S
C
A
L
E
:
N
T
S
T
O
P
P
L
A
T
E
D
O
U
B
L
E
2
X
3
-
1
6
d
x
5
E
A
C
H
S
I
D
E
I
N
E
A
C
H
H
E
A
D
E
R
B
O
T
T
O
M
P
L
A
T
E
S
I
N
G
L
E
2
X
P
T
S
I
M
P
S
O
N
S
T
R
O
N
G
T
I
E
L
T
T
2
0
B
SIMPSON
S
T
R
O
N
G
T
I
E
L
T
T
2
0
B
H 2.5 A
T
A
L
L
S
T
U
D
S
H
2
.
5
A
T
A
L
L
S
T
U
D
S
H
2
.
5
A
T
A
L
L
S
T
U
D
S
1
'
-
9
3
/
4
"
H
E
A
D
E
R
P
E
R
S
C
H
E
D
U
L
E
(2) LS
T
A
2
4
E
A
E
N
D
1
5
/
8
"
(
2
)
-
2
X
4
P
T
S
T
U
D
S
M
I
N
.
E
A
C
H
S
I
D
E
O
F
O
P
E
N
I
N
G
2
X
4
P
T
S
T
U
D
S
@
1
6
"
O
.
C
.
(
2
)
-
2
X
4
P
T
S
T
U
D
S
M
I
N
.
E
A
C
H
S
I
D
E
O
F
O
P
E
N
I
N
G
1
6
d
@
2
4
"
O
.
C
.
S
T
A
G
G
E
R
E
D
H
E
A
D
E
R
S
C
H
E
D
U
L
E
O
P
E
N
I
N
G
H
E
A
D
E
R
S
I
Z
E
U
P
T
O
3
'
-
4
"
(
2
)
2
"
x
6
"
3
'
-
5
"
T
O
5
'
-
4
"
(
2
)
2
"
x
8
"
5
'
-
5
"
T
O
8
'
-
6
"
(
2
)
2
"
x
1
0
"
8
'
-
7
T
O
1
2
'
-
6
"
(
2
)
2
"
x
1
2
"
2X4
H
O
R
I
Z
O
N
T
A
L
B
L
O
C
K
I
N
G
A
T
SHEAT
H
I
N
G
S
P
L
I
C
E
(2) 1
6
d
T
O
E
N
A
I
L
S
E
A
C
H
E
N
D
A
-
A
A
-
3
16d NAI
L
S
@
6
"
O
.
C
.
AT COR
N
E
R
S
T
U
D
S
S
I
Z
E
H
2
.
5
A
T
A
L
L
S
T
U
D
S
H
2
.
5
A
T
A
L
L
S
T
U
D
S
T
O
P
P
L
A
T
E
D
O
U
B
L
E
2
X
3
-
1
6
d
x
5
E
A
C
H
S
I
D
E
I
N
E
A
C
H
H
E
A
D
E
R
H
E
A
D
E
R
P
E
R
S
C
H
E
D
U
L
E
B
O
T
T
O
M
P
L
A
T
E
S
I
N
G
L
E
2
X
P
T
S
I
M
P
S
O
N
S
T
R
O
N
G
T
I
E
L
T
T
2
0
B
2
X
4
P
T
S
T
U
D
S
@
1
6
"
O
.
C
.
8
d
@
2
4
"
O
C
S
T
A
G
G
E
R
E
D
2
-
2
X
4
P
T
S
T
U
D
S
M
I
N
.
E
A
C
H
S
I
D
E
O
F
O
P
E
N
I
N
G
2
-
2
X
4
P
T
S
T
U
D
S
M
I
N
.
E
A
C
H
S
I
D
E
O
F
O
P
E
N
I
N
G
S
I
M
P
S
O
N
S
T
R
O
N
G
T
I
E
L
T
T
2
0
B
T
Y
P
I
C
A
L
W
O
O
D
F
R
A
M
E
W
A
L
L
@
W
I
N
D
O
W
S
E
C
T
I
O
N
S
C
A
L
E
:
N
T
S
(
2
)
L
S
T
A
2
4
E
A
E
N
D
H
E
A
D
E
R
S
C
H
E
D
U
L
E
O
P
E
N
I
N
G
H
E
A
D
E
R
S
I
Z
E
U
P
T
O
3
'
-
4
"
(
2
)
2
"
x
6
"
3
'
-
5
"
T
O
5
'
-
4
"
(
2
)
2
"
x
8
"
5
'
-
5
"
T
O
8
'
-
6
"
(
2
)
2
"
x
1
0
"
8
'
-
7
T
O
1
2
'
-
6
"
(
2
)
2
"
x
1
2
"
2
X
4
H
O
R
I
Z
O
N
T
A
L
B
L
O
C
K
I
N
G
A
T
S
H
E
A
T
H
I
N
G
S
P
L
I
C
E
(
2
)
1
6
d
T
O
E
N
A
I
L
S
E
A
C
H
E
N
D
B
-
B
A
-
3
TYPICAL WOOD FRAME WALL SECTIONSCALE: NTS 4"CONCRETE SLAB NEWCOMPOSITEROOF1/4" DIA. x 5 7/8" LAGSCREWS W/ 1 1/2" DIA.NEOPRENE FACEDWASHER @ 8" O.C.HEADER SCHEDULEOPENINGHEADER SIZEUP TO 3'-4"(2) 2" x 6"3'-5" TO 5'-4"(2) 2" x 8"5'-5" TO 8'-6"(2) 2" x 10"8'-7 TO 12'-6"(2) 2" x 12"SEE HEADER SCHEDULENOTES FOR ALL FOUNDATION TYPES:1.THE FOUNDATIONS SHOWN AREBASED ON A MIN SOIL BEARINGPRESSURE OF 1,500 PSFBEARING CAPACITY OF SOILSHALL BE VERIFIED BY LICENSEDCONTRACTOR PRIOR TOPOURING CONCRETE.2.THE SLAB/FOUNDATION AREASHALL BE CLEARED OF DEBRISAND ROOTS AND SHALL BECOMPACTED PRIOR TOPLACEMENT OF CONCRETE.3.CONCRETE SHALL BE PERSPECIFICATIONS IN THE DESIGNSUMMARY.2X4PT STUD@ 16" O.C.(1) 2" x 4" PT BOTTOM PLATEW/ 3/8" x 4" DIA. SCREWANCHOR @ 2' O.C.GRADE (2) 2X4 TOP PLATENOTES FOR WALL SHEATHING:1.1/2" APA RATED SHEATHINGCONTINUOUS FROM BOTTOM OFBOTTOM PLATE TO TOP OF TOPPLATE. SHEATHING IS PART OFLOAD PATH TO GROUND.2.IF SHEATHING HAS HORIZONTALBREAK, IT CANNOT BE USED ASPART OF LOAD PATH - USEH2.5AT BOTTOM AND H.2 AT TOPOF EACH STUD.VINYL SIDING ON TY-VEXVAPOR BARRIER PAPER ORHOUSE WRAP ON 1/2" APARATED SHEATHING 2X4S.Y.P. @ 16" O.C.NAIL PATTERN:8d 4" O.C. @ EDGES8d 6" O.C. INFILL 12" OVERHANG MAX.S-5A-3
D
O
U
B
L
E
2
X
4
P
T
B
E
A
M
T
O
H
O
S
T
S
T
R
U
C
T
U
R
E
A
T
T
A
C
H
M
E
N
T
D
E
T
A
I
L
S
C
A
L
E
:
N
T
S
S
-
4
A
-
3
2
"
x
8
"
S
M
B
1
1
/
2
"
x
2
1
/
8
"
x
1
1
/
2
"
x
8
"
x
0
.
0
6
2
"
A
L
U
M
R
E
C
E
I
V
I
N
G
C
H
A
N
N
E
L
W
/
(
6
)
#
1
4
x
3
/
4
"
S
M
S
E
A
C
H
S
I
D
E
I
N
T
O
B
E
A
M
(
6
)
1
/
4
"
D
I
A
.
x
3
"
L
A
G
S
C
R
E
W
S
I
N
T
O
W
A
L
L
S
T
A
G
G
E
R
E
D
D
O
U
B
L
E
2
X
4
P
T
B
E
A
M
T
O
H
O
S
T
S
T
R
U
C
T
U
R
E
A
T
T
A
C
H
M
E
N
T
D
E
T
A
I
L
S
C
A
L
E
:
N
T
S
S
-
3
A
-
3
2
"
x
5
"
S
M
B
1 1/2" x 2 1
/
8
"
x
1
1
/
2
"
x
5
"
x
0
.
0
6
2
"
ALUM
R
E
C
E
I
V
I
N
G
C
H
A
N
N
E
L
W/ (4
)
#
1
4
x
3
/
4
"
S
M
S
E
A
C
H
S
I
D
E
I
N
T
O
B
E
A
M
(
3
)
1
/
4
"
D
I
A
.
x
3
"
L
A
G
S
C
R
E
W
S
I
N
T
O
W
A
L
L
S
T
A
G
G
E
R
E
D
TYPE I FOOTING (SLAB)SCALE: NTS 4" NOMINAL SLAB - TYP 1" PER FT. MAX FOR 2'-0"MIN BEFORE STEEPERSLOPETYPE IFLAT SLOPE NO FTG< 2:12NOTES FOR ALL FOUNDATION TYPES:1.THE FOUNDATIONS SHOWN ARE BASED ON A MIN SOIL BEARINGPRESSURE OF 1,500 PSF.2.THE SLAB/FOUNDATION SHALL BE CLEARED OF DEBRIS, ROOTS ANDCOMPACTED PRIOR TO PLACEMENT OF CONC.3.CONCRETE SHALL BE PER SPECIFICATIONS ON SHEET A-1.4.FIBERMESH MAY BE USED IN LIEU FOR WELDED WIRE MESH.5.VAPOR BARRIER NEED NOT BE INSTALLED FOR EXTERIORNON-HABITABLE CONCRETE FLAT WORK.AA-3
COPYRIGHTCNOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF FLORIDA ALUMINUM ENGINEERING, INC.
PROJECT ADDRESS:
D
R
A
W
N
B
Y
D
A
T
E
D
R
A
W
N
R
E
V
I
S
I
O
N
1
2
S
H
E
E
T
N
O
:
3
4 PROFESSIONAL ENGINEER
THOMAS P. ARNETT, P.E.
LICENSE No. #46043
L I C E NS
ETHOMASP.AR
N
E
T
T
P
R
O
F
E
SSIONAL E N G I N E E R
F
LO R I D A5601 MARINER STREET SUITE 240
TAMPA FL. 33609
TEL: (813) 374-2403
FAX: (813) 374-4516
FLORIDA LICENSE: CA LIC. NO. 32807
FLORIDA ALUMINUM
ENGINEERING, INC.
A
-
3
0
6
/
3
0
/
2
0
BOWERS
6563 DULCE REAL AVENUE
FORT PIERCE
FL 34951
T
P
0
3
/
2
6
/
2
0
-
-
-