HomeMy WebLinkAboutWind Load Calculation 500 SW 12th Ave
UR"ur-,,S IGHIDeerfield Beach,FL 33442
DO W S Ph.561-922-6747
Fax.561-292-3562
Property Information Building Information
Owner: GERALD TURGEON Wind Zone: 170 MPH.
Address: 5001 E SEMINOLE RD Exposure Category: C
FORT PIERCE,FL 34951 Minimum Building Dimension: 65 ft.
Mean Roof Height: 20 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive7 Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 End 36 74 7 38.5 -50.6
2 Int 36 74 7 38.5 -42.0
3 End 24 33 7 40.2 -53.8
4 Int 24 62 7 40.1 -43.5
5 Int 58 _ 62 7 37.8 -41.2_
6 Int 24 62 7 40.1 -43.5
REED VEE
JUL 13 2020
ST.-Lucie County,Permitting
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1