Loading...
HomeMy WebLinkAboutWind Load Calculation 500 SW 12th Ave UR"ur-,,S IGHIDeerfield Beach,FL 33442 DO W S Ph.561-922-6747 Fax.561-292-3562 Property Information Building Information Owner: GERALD TURGEON Wind Zone: 170 MPH. Address: 5001 E SEMINOLE RD Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 65 ft. Mean Roof Height: 20 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive7 Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 36 74 7 38.5 -50.6 2 Int 36 74 7 38.5 -42.0 3 End 24 33 7 40.2 -53.8 4 Int 24 62 7 40.1 -43.5 5 Int 58 _ 62 7 37.8 -41.2_ 6 Int 24 62 7 40.1 -43.5 REED VEE JUL 13 2020 ST.-Lucie County,Permitting Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1