Loading...
HomeMy WebLinkAboutCompaction testPort St. Lucie FBPE CA # 4930 607 NW Commodity Cove Port St. Ducie. FL 34986 Phone: 772-924-3575 1 Fax: 772-924-3580 Soil Nuclear Gauge Report Date: 6/29/2020 Test Method: ASTM D 6938 Client: Proctor Construction Company, Inc. 2050 US Hwy 1 Suite 200 Vero Beach, FL 32960 Project: 20-8137.00 Al Truss Maintenance Building - CMT 4451 St. Lucie Blvd. Fort Pierce, FL 34946 `\�ttllrrrl!`/� N KtiT 0 63 8 62Qir2020 `Jath Kent, E. (� JessionA{ L freer.# e a't f F.YSt[ eDP, ' N /1rr)rllt�� Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Test Results Test # Optimum Maximum In Place In Place Probe Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Of Date Proctor ID Method Classification M (pcf) M (pcf) (in) Min/Max Percent Comp. Compaction M Remark 1 6122120 1490 - D1557 N/A 11.3 104.2 10.7 100.8 12 97 951 105 Pass 2 6122120 1490 - D1557 N/A 11.3 104.2 11.5 101.5 12 97 951105 Pass 3 6122120 1490 - D1557 N/A 11.3 104.2 10.6 102.1 12 98 95/105 Pass 4 6122!20 1490 - D1557 NIA 11.3 104.2 11.6 102.2 12 98 95/105 Pass 5 6122120 1490 - D1557 N/A 11.3 104.2 10.0 103.0 12 99 95/105 Pass Test Information Test # Test Location Elevation Reference Gauge Make ! Model I SN 1 Calibrated Field Technician 1 Above Stripped Surface: Building pad, West Corner 1-2 Troxler 1 3430 124566 1 Hayes, Sean 2 Above Stripped Surface: Building pad, East Corner 1-2 Troxler /3430 1 24566 f Hayes, Sean 3 Above Stripped Surface: Building pad, South Corner 1-2 Troxler 13430! 245661 Hayes, Sean 4 Above Stripped Surface: Building pad, North Corner 1 1-2 Troxler 13430 ! 245661 Hayes, Sean 5 JAbove Stripped Surface: Building pad, Center of pad 1-2 Troxler! 3430 1 24566 IHayes,Sean Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 1, 2, 3, 4, 5: Below stripped surface 0-1', Above stripped surface 0-1, 1-2' HCP 40+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil. `\�ttllrrrl!`/� N KtiT 0 63 8 62Qir2020 `Jath Kent, E. (� JessionA{ L freer.# e a't f F.YSt[ eDP, ' N /1rr)rllt�� Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1