Loading...
HomeMy WebLinkAboutTruss Eng• 0 ■ -j w LO U) F- w U) w 0 U) z w w 0 cl Z U) 0 < co z :E v C/) < 2 CY) U) z CO Lu 0 F- 0 U) -j 00 < U) _'j Z w W w 0 0 z 0 -j o n 0 0 CL 0 O f Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 A-1 ROOF These truss designs rely on lumber values established by others. �TRUSSES RE: Job 81173 A FLORIDA CORPORATION A-1 Roof Trusses 4451 St Lucie Blvd Site Information: Fort Pierce, FI �aa4F Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE Lot/Block: 28 Model: SEAMIST 2215 Address: 9725 STARBOARD DRIVE Subdivision: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC 2017 RES / TPI 2014 Design Program: Alpine Engineered Products Wind Code: ASCE 7-10 Wind Speed: 160 Roof Load: 40.0 psf Floor Load: 55.0 psf This package includes 32 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seq # Truss Name Date No. Seq # Truss Name Date No. Seq # Truss Name Date 1 2689 A01 GE 6/17/20 13 2722 A 6/17/20 25 2664 FL02GE 6/17/20 2 2743 A02 6/17/20 14 2737 J3 6117120 26 2512 FL03 6/17/20 3 2704 A02GE 6/17/20 15 2728 J5 6/17/20 27 2547 FL03GE 6/17/20 4 2692 B01 6/17/20 16 2608 J5C 6/17/20 28 2508 FL04 6/17/20 5 2695 B02GE 6/17/20 17 2619 J7 6/17/20 29 2661 FL05 6/17120 6 2734 C01 6/17120 18 2698 L01 6/17120 30 2676 FL06G 6/17/20 7 2710 CO2 6/17120 19 2740 L02 6/17/20 31 2486 FL07GE 6/17/20 8 2752 CO3 6/17/20 20 12616 Vol 6/17/20 32 12673 FL08 6/17/20 9 2613 C04G 6/17/20 21 2622 V02 6/17/20 33 1 STDL01 STD. DETAIL 6/17120 10 2749 D01 6/17/20 22 2544 FG01 6/17/20 34 STDL02 STD. DETAIL 6/17/20 11 2719 D02GE 6/17/20 23 2521 FL01 6/17120 35 STDL03 STD. DETAIL 6/17120 12 12731 HP 6/17/20 24 2682 FL02 6/17/20 36 STDL04 I STD. DETAIL 6/17/20 II a uuSS UIaWn.gk.)ICICIeilc IIdve UCGII prepdICU UylV�JII IG CnyluCClCU C'IVUUGLI,IIIU. UI IUCI i I iy Ulf CUlbUIJCIVIbIUI I UdbMUI I UICPdldI 1 lt=lbPIUVIUCUUyA-I RUUI n Ubbt:b,L.N. Truss Design Engineer's Name: Manuel Martinez My license renewal date for the state of Florida is February 28,2021. NOTE: The seal on these drawings indicate acceptance of professional engineering responsibility solely forthe truss components shown. The suitability and use of components for any particular building is the responsibility of the building designer, perANSUTPI-1 Sec. 2. The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction documents (also refered to at times as'Structural Engineering Documents') provided by the Building Desig ner indicating the nature and characterof the work. The design criteria therein have been transferred to Manuel Martinez PE by [Al Roof Trusses or specific location]. These TDDs (also referred to at times as'Structural Delegated' Engineering Documents') are specialty structural component designs and may be part of the project's deferred orphased submittals. As a Truss Design Engineer(i.e, specialty Engineer), the seal here and on the TDD represents an acceptance of professional engineering responsibility, forthe design of the single Truss depicted on the TDD only. The Building Designeris responsible forand shall coordinate and review the TDDs for compatibility with theirwritten engineering requirements. Please review all TDDs and all related notes. Manuel Digitally signed by Manit�sllAftinez Martine 71 Manuel Martinez, P.E. 4620 ParkV'lew Dr. St. Cloud, FL 34771 SMA5 r03 18120070105204 4EACES CA Page 1 of 2 Manuel Martinez, P.E. r1047182 4620 ParkView Dr St Cloud, FL 34771 Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 A®1 ROOF These truss designs rely on lumber values established by others. jig, TRUSSES A FLORIDA CORPORATION RE: Job ARMSSMB1 L No. Seq # Truss Name Date 37 STDL05 STD. DETAIL 6/17/20 38 STDL06 STD. DETAIL 6/17/20 39 STDL07 STD. DETAIL 6/17/20 40 STDL08 STD. DETAIL 6/17/20 41 STDL09 STD. DETAIL 6/17120 42 STDL10 STD. DETAIL 6/17120 43 STDL11 STD. DETAIL 6/17/20 44 STDL12 STD. DETAIL 6/17/20 45 STDL13 STD. DETAIL 6/17/20 46 STDL14 STD. DETAIL 6/17/20 47 STDL15 STD. DETAIL 6/17/20 48 1 STDL16 STD. DETAIL 6/17/20 Manuel Martinez, P.E. # 047182 Page 2 of 2 4620 ParkView Dr St Cloud, FL 34771 Job t• IARMSSMB1L Iruss A01GE truss type GABL 1ty ( ly I Ub/1112U2U 2689 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 16T1 1 91015 -) Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Fasten rated sheathing to one face of this frame. Plating Notes All plates are 1.5X3 except as noted. (**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Puriins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 16.25 25.28 BC 120 0,00 25.28 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes See STD DETAILS for gable wind bracing requirements. 05X6 -3X3 Ill Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): -0.010 AE 999 3E VERT(CL): -0.014 AE 999 24 HORZ(LL): -0.036 C - - HORZ(TL): 0.042 C Creep Factor: 2.0 Max TC CSI: 0.307 Max BC CSI: 0.178 Max Web CSI: 0.246 Wgt: 249.2 Ibs ♦ Maximum Reactions (Ibs), or *=PLF Gravity Non -Gravity Loc R+ / R- i Rh / Rw / U / RL AF 201 /- /- /165 /105 /455 R* 80 /- /- /48 /30 /- Wind reactions based on MWFRS AF Brg Width = 7.4 Min Req = 1.5 R Brg Width = 295 Min Req = - Bearings AF & AE are a rigid surface. Bearings AF & AE require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 I A - B 43 0 1-1 524 -108 B-C 149 -62 J-K 601 -122 C - D 173 - 48 K - L 541 -108 D - E 260 - 66 L - M 571 -109 E - F 320 - 75 M - N 571 -109 F-G 381 -86 N-O 571 -109 G - H 388 - 80 O - P 571 -109 H - 1 456 -97 P-Q 1 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. AF-AE 199 -599 Y-X 1 -2 AE-AD 1 -3 X-W 1 -2 AD -AC 1 -2 W - V 1 -2 AC -AB 1 -2 V - U 1 -2 AB -AA 1 -2 U-T 1 -2 AA-Z 1 -2 T-S 1 -2 Z-Y 1 -2 S-R 0 -1 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp AE-AG 126 -630 AR -AS 117 -610 AG-AH 131 - 645 AS- X 226 -125 AH-AD 253 -187 AT -AU 116 - 609 AI-AJ 122 - 619 AU- W 6 -133 AJ-AC 91 -105 AV-AW 116 - 608 AK -AL 123 - 626 AW- V 62 -129 AL -AB 147 -127 AX-AY 116 - 611 AM -AN 121 - 619 AY- U 111 -124 AN -AA 138 -124 AZ -BA 115 - 606 AO -AP 119 - 615 BA- T 106 -126 AP-AQ 119 -615 BB -BC 118 -617 AQ- Z 145 -124 BC- P 60 - 325 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. -WARNING`* Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' forth. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineed responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (:nnvriaht n 2n16 A-1 Roof To-- Ron—Mr.tion of this dom—ntin nnv form. ie nrohibited without the wdHen nemlesinn of AA Rmf Tnic Manuel Martinez, P.E. # 047182 4620 ParkView Or St Cloud, FL 34771 2689 A01 GE GABL 1 1 AF- B 365 - 204 J -AT 235 , '-123 C -AG 55 - 53 K -AV 8 -135 D -Al 189 -152 M -AX 66 -130 E -AK 119 -114 N -AZ 98 -122 F -AM 140 -124 O -BB 146 -136 H -AO 137 -123 BC- S 271 -107 1-AR 137 -123 Q - R 58 - 28 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Convn,ht cn 201a A-1 Rnnf Trrias-- Renrndnntinn of this dmimenl, in anv fnnn. is nrnhihitnd Wthnnt tha wnHnn rwrrnissinn of A-1 Rnnf Tn.-., Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 IJob I russ I russ I ype Qty Ply 06/17/2020 ARN4SSMB1L I A02 I COMN I g 11 I 2743 Loading Criteria(psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " i 12'11'2 1 14'6'4 1 1016, SEAT PLATE REQ. Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.79 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP 240017-2.0E :T3, T4 2x4 SP M-30: :T5 2x4 SP #2: Bot chord 2x4 SP #2 :B2 2x4 SP M-30: Webs 2x4 SP #3 25'5'2 Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes (**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 69 0.20 37.91 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Negative reaction(s) of -214# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. Shim all supports to solid bearing. 1w _ 12V12 � 12'8°-I—a�l Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.143 C 999 361 VERT(CL): 0.298 C 999 241 HORZ(LL): 0.063 C - - HORZ(TL): 0.130 C Creep Factor: 2.0 Max TC CSI: 0.700 Max BC CSI: 0.984 Max Web CSI: 0.846 Wgt: 201.6 Ibs VIEW Ver: 19.01.00A.0618.16 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL O 902 /- /- /526 /185 /450 N 2363 /- /- /1588 /853 /- K 311 /-214 /- /248 /186 /- Wind reactions based on MWFRS O Erg Width = 7.4 Min Req = 1.5 N Erg Width = 3.5 Min Req = 2.8 K Erg Width = 3.5 Min Req = 1.5 Bearings O, N, & K are a rigid surface. Bearing O requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- B 40 0 G- H 1824 -1048 B - C 1271 - 2227 H -1 1656 - 754 C - D 376 - 854 I - J 831 - 274 D - E 394 - 829 J - K 758 - 301 E-F 414 -729 K-L 35 0 F - G 1685 -1065 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. N - M 803 - 935 M - K 370 - 646 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - O 753 - 797 R - F 650 -188 B - P 2044 - 982 R - N 698 - 448 O - P 295 - 535 F - N 1528 - 2104 P - C 238 - 86 N - H 675 - 487 P - Q 2022 -1580 N -1 957 -1658 C - R 1087 -1270 I - M 577 - 400 Q - R 2070 -1572 M - J 466 - 362 *"WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineemi responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Manuel Martinez, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 047182 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss St Cloud, FL 34771 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. r:nnvdnht C12016 A.1 Roof Tn .-- Renrodnntinn of this dornment. in anv form. is nrnhihited withnui tha written nennissinn of A-1 Ronf Tnicses JoD I runs I Fuss I ype my rty unrl //LULU ARMSSMB1L I A02GE ( GABL 12 1 ( 2704 10'6" i10'6"14 Loading Criteria (psf) Wind Criteria Code / Misc Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) EXP: B Kzt: NA Plate Type(s): Des Ld: 40.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.15 21.69 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for gable wind bracing requirements. H=­ 21'8"5 Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.006 N 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.012 N 999 240 B* 86 /- /- /44 /32 /8 HORZ(LL): -0.003 E - - Wind reactions based on MWFRS HORZ(TL): 0.003 E - - B Brg Width = 260 Min Req = - Creep Factor: 2.0 Bearing B is a rigid surface. Max TC CSI: 0.256 Maximum Top Chord Forces Per Ply (Ibs) Max BC CSI: 0.124 Chords Tens.Comp. Chords Tens. Comp. Max Web CSI: 0.070 A B 39 0 G H 186 25 Wgt: 107.8 Ibs B - C 62 -165 H -1 185 -23 C-D 66 -118 I-J 130 -22 VIEW Ver: 19.01.00A.0618.16 D - E 53 -49 J - K 53 -37 E - F 109 - 32 K - L 53 - 59 F-G 188 -21 L-M 78 -142 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - W 232 - 89 R - Q 205 - 70 W - V 239 - 91 Q - P 204 - 69 V - U 243 - 94 P - O 201 - 68 U - T 246 - 95 O - N 198 - 66 T - S 250 - 96 N - M 187 - 62 S - R 251 - 97 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. C-W 102 -87 Q-1 179 -130 D-V 145 -128 P-J 175 -126 E-U 134 -123 O-K 118 -102 F - T 228 -121 N - L 266 -187 G-S 51 -136 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional enginesri responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the content of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I. Cnnvdnht C OIR A-Y Roof Trims- - R-mch.dinn of this do-mentin anv fnrrn. is nmhihtted without tha written m?nnissinn of A-1 R—f Tmcses. Manuel Martinez, P.E. # 047182 4620 ParkView Or St Cloud, FL 34771 Job ARK4SSMB1 L truss Truss Type Qty Ply B01 I SPEC 12 11 06/17/2020 r.•_ Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " �I SEAT PLATE REQ. 16'11"14 16'11"14 f- 1.6.3 -1 16s'6 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP 2400f-2.OE :T2 2x4 SP #2: Bot chord 2x4 SP #2 :B2 2x4 SP M-30: Webs 2x4 SP #3 :Rt Bearing Leg 2x6 SP #2: Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.20 16.53 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.087 C 999 360 Loc R+ / R- / Rh / Rw / U / RL 1 810 /- /- /518 /171 /473 VERT(CL): 0.178 C 999 240 HORZ(LL): 0.033 H - - F 688 /- /- /490 /398 /- HORZ(TL): 0.067 H Wind reactions based on MWFRS Creep Factor: 2.0 1 Brg Width = 7.4 Min Req = 1.5 Max TC CSI: 0,676 F Brg Width = 1.5 Min Req = 1.5 Max BC CSI: 0.623 Bearings I & F are a rigid surface. Max Web CSI: 0.726 Bearing I requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:95.9lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 A - B 40 0 C - D 5 - 317 B - C 970 -1860 D - E 41 - 289 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. I - H 133 - 653 H - G 1711 -1468 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - 1 658 - 713 C - G 1167 -1407 B - H 1665 - 755 F - G 515 - 350 H - C 235 - 25 E - F 1950 -1594 .*WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvdnht n 2016 AA Rnnf Tnicvos— Ronmdmntinn of thi., d—mnntin anv form, is nmhihited vnthnuf thn —iffnn nP.nnissinn of A-1 Rnnf Tmcaa,. Manuel Marfinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 JUU ARMSSMBI L I1uas Ilusb IyNe �ny B02GE I GABL 14.tty 11 Vol I //LULU 2695 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Lid: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0,18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 :M10 2x4 SP M-30: Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 104 0.00 16.95 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes See STD DETAILS for gable wind bracing requirements. Shim all supports to solid bearing. 161 V6 Defl/CSI Criteria ♦ Maximum Reactions (ibs), or'=PLF PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): -0.021 C 999 360 Loc R+ / R- / Rh / Rw / U / RL N* 88 /- /- /59 /34 /28 VERT(CL): -0.028 C 999 240 HORZ(LL): -0.031 C - - Wind reactions based on MWFRS HORZ(TL): 0.037 C N Brg Width = 203 Min Req = - Creep Factor: 2.0 Max TC CSI: 0.371 Bearing X is a rigid surface. Bearing X requires a seat plate. Max BC CSI: 0.975 Maximum Top Chord Forces Per Ply (Ibs) Max Web CSI: 0.186 Chords Tens.Comp. Chords Tens. Comp. A - B 47 0 G - H 55 - 331 B - C 72 - 543 H -1 44 - 265 C - D 99 -577 I - J 33 -199 D-E 72 -451 J -K 23 -108 Wgt: 165.2 Ibs VIEW Ver: 19.01.00A.0618.16 E-F 67 -404 K-L 9 -19 F - G 45 - 334 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. X-W 62 -3 S-R 2 0 W-V 667 -128 R-Q 2 0 V-U 668 -128 Q-P 2 0 U-T 668 -128 P-O 2 0 T-S 668 -128 O-N 2 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B - Y 626 -132 AF-AG 13 - 24 W - Y 139 - 616 AG- R 138 -124 Y-Z 35 -90 AH-AI 9 -21 Z - V 492 -183 AI- Q 140 -124 AA -AB 19 -14 AJ-AK 6 -17 AB- U 28 -106 AK- P 195 -131 AC -AD 18 -33 AL -AM 2 -11 AD- T 157 -127 AM- O 180 - 95 AE-AF 13 - 24 AN- M 2 -10 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. X-B 63 -224 1-AJ 138 -123 Y-C 33 -131 J-AL 191 -129 D -AA 289 -152 K -AN 186 - 98 E -AC 89 -114 M - L 40 - 21 F -AE 145 -124 M - N 48 - 24 H -AH 138 -123 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TOD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specially Engineer), the seal on any TDD represents an acceptance of the professional engineed responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvdoht () 2016 A-1 Roof To.--- Renmdnrtion of this dminnantin env fnnnis nrohihited wilhnlrt the written nermission of AA Roof Tmsses Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job I russ I russ I ype Uty Fly uei1 /fzuzu ARK4SSMB1 L C01 HIPS 1 1 2734 263# 194 194# 194f( 263# �- 776 -�j-- 2,0,6 1'5"4 rii s"4 2,0.6 - T TO"6 - �{ 7' T "" 7' 1'5"9 Loading Criteria (psf) Wind Criteria TCLL 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: B Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 it Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 :T2 2x6 SP 2400f-2.OE Bot chord 2x4 SP 2400f-2.OE Webs 2x4 SP #3 Special Loads -----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at -1.46 to 62 plf at 7.00 TC: From 31 pif at 7.00 to 31 plf at 14.00 TC: From 62 plf at 14.00 to 62 plf at 22.46 BC: From 20 plf at 0.00 to 20 plf at 7.00 BC: From 10 plf at 7.00 to 10 plf at 13.97 BC: From 20 plf at 13.97 to 20 plf at 21.00 TC: 263 lb Conc. Load at 7.03,13.97 TC: 194lb Conc. Load at 9.06,10.50,11.94 BC: 514 lb Conc. Load at 7.03,13.97 BC: 131 lb Conc. Load at 9.06,10.50,11.94 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 7.00 14.00 BC 78 0.04 20.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. 20'11" 21' + 131# + 131# + 514# 131# 514# Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.102 H 999 36 Vr:RT(CL): 0.203 H 999 24 HORZ(LL): 0.042 G - HORZ(TL): 0.083 G Creep Factor: 2.0 Max TC CSI: 0.448 Max BC CSI: 0.987 Max Web CSI: 0.324 Wgt: 94.5 Ibs VIEW Ver: 19.01.00A.0618.16 1'5"9 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 2073 /- /- /- 1909 /- E 2073 /- /- /- /909 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.7 E Brg Width = 3.5 Min Req = 1.7 Bearings B & E are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 39 - 26 D - E 1722 - 3984 B - C 1722 - 3988 E - F 39 - 26 C - D 1494 - 3494 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - H 3497 -1494 G - E 3494 -1494 H - G 3462 -1491 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. H-C 841 -61 D-G 850 -61 C-G 36 -3 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Tmss System Engineer of any building. All capitalized terns are as defined in TPI-1. Cnnvdnht t72n16 A-1 Ronf Tnisses - Renrodnntion of this dmiment. in - form. is nmhihited mthnut the written hemission of A-1 Ronf Tmxaes. Manuel Martinez, P.E. # 047182 4620 PafkView or St Cloud, FL 34771 ,Ion I russ I russ I ype city my 0671021.120 ARMSSMB1L CO2 HIPS 1 1 27�0 1'5"9 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP M-30 Webs 2x4 SP #3 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 12.00 BC 120 0.04 20.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 9'i 3' -i 9' :5X6 1112X4 -5X6 D E F 20'11" ffm 1.5"9 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.073 J 999 360 Loc R+ / R- / Rh / Rw / U / RL B 952 /- /- /572 /372 /161 Rep Factors Used: Yes VERT(CL): 0.146 J 999 240 FT/RT:10(0)/10(10) HORZ(LL): 0.023 C - - H 952 /- /- /572 /372 /- Plate Type(s): HORZ(TL): 0.045 C Wind reactions based on MWFRS WAVE Creep Factor: 2.0 B Brg Width = 3.5 Min Req = 1.5 Max TC CSI: 0.741 H Brg Width = 3.5 Min Req = 1.5 Max BC CSI: 0.682 Bearings B & H are a rigid surface. Max Web CSI: 0.233 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Wgt: 92.4 Ibs A- B 39 0 E- F 444 - 948 VIEW Ver: 19.01.00A.0618.16 B - C 554 -1371 F - G 473 -1092 C - D 473 -1092 G - H 554 -1371 D- E 444 - 948 H- 1 39 0 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - J 1157 - 356 J - H 1157 - 368 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C-J 251 -310 J-G 251 -310 E-J 613 -227 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-I. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvnaht n 2016 A-1 Rnnf Tntcaec — Renrnduntinn of thie dnnarn,ntin anv form. is nrnhihited without the written nnemNMs of A-1 Rnnf Tmecas Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job ® ARMSSMB1 L Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP M-30 Webs 2x4 SP #3 I russ I russ I ype CO3 COMN 1'5"9 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.04 20.81 Apply purlins to any chords above or below fillers at 24" CIC unless shown otherwise above. iNY-i Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. 1ty ( 1y 106/17/2020 10'5"8 D-4X4 20'11" 20'11"8 Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.040 G 999 36 VERT(CL): 0.081 G 999 24 HORZ(LL): 0.016 G - HORZ(TL): 0,033 G Creep Factor: 2.0 Max TC CSI: 0.426 Max BC CSI: 0.630 Max Web CSI: 0.250 Wgt: 93.8 Ibs VIEW Ver: 19.01.00A.0618.16 2752 =3X4(A1) I i_ 1 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 949 /- /- /565 /190 /164 F 864 /- /- /485 /163 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 F Brg Width = 3.5 Min Req = 1.5 Bearings B & F are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- B 39 0 D- E 438 -1072 B - C 549 -1434 E - F 568 -1426 C-D 419 -1073 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - G 1234 - 415 G - F 1224 - 411 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - G 278 - 389 G - E 280 - 378 D-G 631 -159 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Ce-dnht 0 201a AA R-f TnissP_v- Renrnrtnntinn of this d-nmant in an, form. is nroinhited with-1 the written nennissinn of A-1 Roof Tniasas. Manuel Martinez, P.E. 4047182 4620 ParkView Dr St Cloud, FL 34771 JOO ARMSSMB1 L l russ 1 russ type C04G ( COMN c tty rly I UO/ 111LULU 1 1 2613 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " =3X4(F i- ----- 5'5"8 i 5'5"13 -- if B=4X4 10,11" �-- 2'0"4 -�- 2, 294# 1,5"4 1-1,5n294# 2 �- 2 0 4 --{ 294# 294# 294# Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x6 SP 2400f-2.OE Webs 2x4 SP #3 Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at 0.00 to 62 pif at 10.92 BC: From 10 plf at 0.00 to 10 plf at 10.92 BC: 294 Ib Conc. Load at 2.02, 4.02, 5.46, 6.90 8.90 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.15 10.77 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.024 D 999 361 §FERT(CL): 0.046 D 999 24, HORZ(LL): 0.006 D - - HORZ(TL): 0.012 D Creep Factor: 2.0 Max TC CSI: 0.218 Max BC CSI: 0.304 Max Web CSI: 0.442 Wgt: 49.0 Ibs VIEW Ver: 19.01.00A.0618.16 3X4(A1) ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL A 1129 /- /- /- /352 /- C 1129 /- /- !- /352 /- Wind reactions based on MWFRS A Brg Width = 3.5 Min Req = 1.5 C Big Width = 3.5 Min Req = 1.5 Bearings A & C are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 538 -1740 B - C 538 -1740 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-D 1510 -447 D-C 1510 -447 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B - D 1161 - 229 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1. Convnnht r)e 20M A-1 Roof Tnicar_c- Ranmduotinn of lhhe d-i-ntin anv fnnn. it nmhihltad without tha wnftnn naemMmn of AA Roof To teas. Manuel Martinez, P.E. # 047182 4620 ParkView Or St Cloud, FL 34771 Job ARMSSMB1 L i russ I russ Type Qty Ply D01 I MONO 12 ( 1 06/17/2020 2749 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " SEAT PLATE REQ. f 1'5,9 --� Wind Criteria Wind Sid: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 93 0.15 7.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 7'10"8 n C0 M V Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): 0.015 F 999 360 Loc R+ / R- / Rh / Rw / U / RL B 424 !- /- /393 /136 /236 Rep Factors Used: Yes VERT(CL): 0.021 F 999 240 FT/RT:10(0)/10(10) HORZ(LL): 0.008 F - - E 219 /- /- /265 /94 /- Plate Type(s): HORZ(TL): 0.011 F D 93 /- /- /48 /90 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.184 B Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.573 E Brg Width = - Min Req = - Max Web CSI: 0.137 D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 35.0 Ibs Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp. A-B 39 0 C-D 42 -135 B - C 165 - 351 Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B- F 286 -406 F- E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 462 - 324 *`WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPF1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I. Cnnvrinht 0 2016 A-1 Rnnf Te,--- Ren—in Jinn of this domimentin env forte, is nmhihited without the written nemissinn of A-1 Rnnf Tnc .%. Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job ARMSSMB1 L I russ I russ I ype G2ty Pry D01 I MONO 1 2 11 06/11/2020 2749 Loading Criteria (pst) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " SEAT PLATE REQ. f -- 1'S"9 --- Wind Criteria Wind Sid: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 93 0.15 7.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 9 7'10"8 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): 0.015 F 999 360 Loc R+ / R- / Rh / Rw / U / RL B 424 /- /- /393 /136 /236 Rep Factors Used: Yes VERT(CL): 0.021 F 999 240 FT/RT:10(0)/10(10) HORZ(LL): 0.008 F - - E 219 /- /- /265 /94 /- Plate Type(s): HORZ(TL): 0.011 F D 93 /- /- /48 /90 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.184 B Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.573 E Brg Width = - Min Req = - Max Web CSI: 0.137 D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 35.0 Ibs Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp. A-B 39 0 C-D 42 -135 B - C 165 - 351 Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B- F 286 - 406 F- E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 462 - 324 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineed responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrinht 02MA A-1 Rnnf Tntscas— Rnnrndnnlinn of thi, dnnumenl. in anv torn. is nrnhihited without the written m micxinn of A-1 Rnnf Tmcsns Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job Truss Truss Type ARMSSMB1L I FG01 I FLAT Q PI 1ty 121 10611712020 2544 T 16'8"8 =3X12 =5X10 III1.5X3 A B C P� I O N M L I14j 4 =4X10 III1.5X3 =H0312 =5X6 SEAT PLATE REQ. 16'8"8 III1.5X3 =6X6 =5X10 =3X12 D E F G K J I H =5X6 1111.5X3 =5X8 11144 Loading Criteria (pso Wind Criteria Code / Misc Criteria Defi/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 40.00 Wind Std: NA Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: NA mph TPI Std: 2014 VERT(LL): 0.095 D 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: NA Rep Factors Used: No VERT(CL): 0.447 D 448 240 P 3333/- BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) HORZ(LL): 0.017 H - H 3333 EXP: NAKzt: NA Plate Type(s): HORZ(TL): 0.079 H P Brg Width = 4.0 Min Req = 1.5 Des Ld: 55.00 Mean Height: NA ft WAVE, HS Creep Factor: 2.0 H Brg Width = 3.5 Min Req = 1.5 NCBCLL: 0.00 TCDL: NA sf p Max TC CSI: 0453 Bearings P & H are a rigid surface. Load Duration: 1.00 BCDL: NA psf . Max BC CSI: 0.835 Bearing P requires a seat plate. Spacing: 24.0 " MWFRS Parallel Dist: NA Max Web CSI: 0.798 Maximum Top Chord Forces Per Ply (Ibs) C&C Dist a: NA ft Chords Tens.Comp. Chords Tens. Comp. Loc. from endwall: NA Wgt: 207.2 Ibs I: NA GCpi: NA A - B 0 -2601 D - E 0 -6669 Wind Duration: NA VIEW Ver: 19.01.00A.0618.16 B - C 0 -6669 E - F 0 -6669 Lumber C- D 0 -6758 F- G 0 -2614 Top chord 2x8 SP 2400f-1.8E Bot chord 2x4 SP 2400f-2.0E Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 :W1 2x6 SP #2: Chords Tens.Comp. Chords Tens. Comp. :W2, W5 2x4 SP #2: P - O 58 0 L - K 6758 0 Nailnote O- N 4734 0 K- J 4753 0 Nail Schedule:0.131 "x3", min. nails N - M 4734 0 J - 1 4753 0 Top Chord: 1 Row @ 6.50" o.c. M - L 4734 0 1- H 58 0 Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Maximum Web Forces Per Ply (Ibs) Use equal spacing between rows and stagger nails Webs Tens.Comp. Webs Tens. Comp. in each row to avoid splitting. (1) 1 /2" bolts may be used for A - P 0 -1631 D - K 0 - 550 (2) 0.131"x3", min. nails on A - O 2815 0 K - F 2051 0 The Top Chord Only. O- B 0 -2453 F- J 9 0 B-N 10 0 F-I 0 -2461 Special Loads B- L 2068 0 I- G 2828 0 ----(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) L - C 0 - 553 G - H 0 -1631 TC: From 389 plf at 0.00 to 389 plf at 16.71 BC: From 10 pif at 0.00 to 10 plf at 16.71 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.00 16.71 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Additional Notes Truss must be installed as shown with top chord up. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TOD) and the Specialty Engineer reference sheet before use. unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TOD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (:nnvdnht n 2Me A-1 Rnnf Tnieaes - Ranrnd"rtinn of thi.¢ dnnnment. in anv fnnn. is omhihitnd withmil thn wdHen nennission of A-1 Ronf Tmeces. Manuel Martinez, P.E. # 047162 4620 ParkView Dr St Cloud, FL 34771 Jon I russ I russ I ype uty wy Will nzozW ARMSSMB1 L I FL01 I SY42 12 11 I , 2521 �- 2'6" --{ (TYP) '---_ 5'3" 7'3" III 1.5X3 3"1 L 1.5X3(R) 3"1 K' 3X4 127'8 =3X6 III 1.5X3 III 1.5X3 =3X6 B C D E III 1.5X3 F . "G1.5X3(R) ■■ N ■: iM M \ :�:IM I / �t ■ 1■I 3X4 Sce SEAT PLATE REQ. 12'7"8 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 40.00 Wind Std: NA Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: NA mph TPI Std: 2014 VERT(LL): 0.118 C 999 360 Loc R+ / R- / Rh / Rw / U ! RL BCLL: 0.00 Enclosure: NA Rep Factors Used: Yes VERT(CL): 0.195 C 744 240 K 681 BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) HORZ(LL): 0.022 B - - H 681 /- /- /- /- /- EXP: NAKzt: NA Plate Type(s): Des Ld: 55.00 HORZ(TL): 0.036 B - - K Brg Width = 7.5 Min Req = 1.5 Mean Height: NA ft WAVE Creep Factor: 2.0 H Brg Width = 3.5 Min Req = 1.5 NCBCLL: 0.00 TCDL: NA psf Max TC CSI: 0.571 Bearings K & H are a rigid surface. Load Duration: 1.00 BCDL: NA sf p " Max BC CSI: 0.658 Bearing K requires a seat plate. Spacing: 24.0 MWFRS Parallel Dist: NA C&C Dist a: NA ft Max Web CSI: 0.346 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: NA Chords Tens.Comp. Chords Tens. Comp. Wgt: 70.0 Ibs I: NA GCpi: NA A- B 1 0 D- E 0 -1651 Wind Duration: NA VIEW Ver: 19.01.00A.0618.16 B - C 0 -1651 E - F 1 0 Lumber C - D 0 -1663 Top chord 4x2 SP #2 Bot chord 4x2 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Webs 4x2 SP #3 Chords Tens.Comp. Chords Tens. Comp. Puriins K- J 1125 0 1- H 1125 0 In lieu of structural panels or rigid ceiling use purlins J -1 1663 0 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) Maximum Web Forces Per Ply (Ibs) BC 120 0.25 12.38 Webs Tens.Comp. Webs Tens. Comp. Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. L - M 0 -4 D - I 0 - 217 A-K 0 -108 1 - E 656 0 Additional Notes K- B 0 -1250 E- H 0 -1250 + 2x6 continuous strongback. B - J 656 0 F - H 0 -108 Truss must be installed as shown with top chord up. J - C 0 -217 G - N 0 -4 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TOO, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Manuel Martinez, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field # 047182 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Or guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss St Cloud, FL 34771 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I. Cnnvnnht 0201a A-1 Rnnf Tniccr_s- Ranrndnntion of this drx —nt. in anv fnnnis nrnhihif,d wilhrnd the wdffen nsmi sin, of AA Ronf Tnissss. Job Truss Truss Type Qty Ply 06/17/2020 ARMSSMB1L FL02 I SY42 15 I 1 I 2682 --2'6n---� (TYP) r 5'3" - -j— 7'9"8 12'5" 1411"8 - -{— 17'9" 207"8 --� 1.5X3(R) =3X6 =3X6 W=3X6 =3X8 =3X4 1112X4 3"1 S A B C D E F G H I J 1.5X3(R) T 3"1 Q P O M N M L K 3X4 =3X4 =3X4 W=3X6 =3X8 1114X4 =3X6 2 Y' 2'5" SEAT PLATE REQ. 12'5"12 8' 1 "12 i- 20'7"8 Loading Criteria (psi) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 40.00 Wind Std: NA Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: NA mph TPI Std: 2014 VERT(LL): 0.169 C 867 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: NA Rep Factors Used: Yes VERT(CL): 0.266 C 551 240 R 692 /- /-/- BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) HORZ(LL): 0.033 B - - N 1144 EXP: NA Kzt: NA Plate Type(s): HORZ TL 0.053 B ( )' K 472 Des Ld: 55.00 Mean Height: NA ft WAVE Creep Factor: 2.0 R Brg Width = 7.5 Min Req = 1.5 NCBCLL: 0.00 TCDL: NA psf Max TC CSI: 0.978 N Brg Width = 3.5 Min Req = 1.5 Load Duration: 1,00 BCDL: NA psf K Brg Width = - Min Req = - Spacing: 24.0 " MWFRS Parallel Dist: NA Max BC CSI: 0.733 Bearings R & N are a rigid surface. C&C Dist a: NA ft Max Web CSI: 0.353 Bearing R requires a seat plate. Loc. from endwall: NA Wgt: 114.8 Ibs Maximum Top Chord Forces Per Ply (Ibs) I: NA GCpi: NA Chords Tens.Comp. Chords Tens. Comp. Wind Duration: NA VIEW Ver: 19.01.00A.0618.16 Lumber A- B 1 0 F- G 218 -120 Top chord 42 SP #2 B - C 0 -1683 G - H 218 -120 Bot chord 4x2 SP #2 C - D 0 -1695 H - 1 0 - 701 Webs 4x2 SP #3 D- E 0 -1681 I- J 3 0 E -F 218 -120 Plating Notes All plates are 1.5X3 except as noted. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Purlins R-Q 1145 0 N-M 700 0 In lieu of structural panels or rigid ceiling use purlins Q - P 1695 0 M - L 701 0 to laterally brace chords as follows: P - O 1191 0 L - K 699 0 Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 20.38 O - N 1191 0 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Additional Notes + 2x6 continuous strongback. S - T 0 -4 G - N 0 - 291 Truss must be installed as shown with top chord up. A-R 0 -108 N-H 0 -810 R - B 0 -1273 H - M 69 -7 B- Q 628 0 L- I 56 - 27 Q- C 0- 226 I- K 0 - 779 D-P 0 -302 K-J 0 -15 P-E 720 0 J-K 0 -127 E-N 0 -1239 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Manuel Martinez, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 047182 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss St Cloud, FL 34771 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPIA. C,nvnnht n 2016 A-1 Rnnf TmeeAR— Renrndnntinn of INN dnr re-1. io anv fnnn. iN nrnhihited vrith-1 the wnttnn nemil-ion of A-1 Ronf TmaceN. pop I russ I russ I ype ury I rly Ub/1 //ZUZU ARMSSMB1L I FL02GE I SY42 1 1 2664 H �— 1'4" (TYP) 1'3"4 1774 18'3A r 27"4 III2X4 =3X3 =3X3 1112X4 A B C D E F G H I J K L M N O HV Hl.. 1112X4(R) =3X3 HH L T A vv v SEAT PLATE REQ. 18'3"8 Loading Criteria (pstl Wind Criteria Code / Misc Criteria TCLL: 40.00 Wind Std: NA Code: FBC 2017 RES TCDL: 10.00 Speed: NA mph TPI Std: 2014 BCLL: 0.00 Enclosure: NA Rep Factors Used: Yes BCDL: 5.00 Category: NA FT/RT:10(0)/l0(10) EXP: NA Kzt: NA Plate Type(s): Des Ld: 55.00 Mean Height: NA fit WAVE NCBCLL: 0.00 TCDL: NA psf Load Duration: 1.00 BCDL: NA psf Spacing: 24.0 " MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwail: NA I: NA GCpi: NA Wind Duration: NA Lumber Top chord 4x2 SP #2 Bot chord 42 SP #2 Webs 4x2 SP #3 Bracing Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 18.04 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes .END + continuous strongback. Truss must be installed as shown with top chord up. U I a R Q 1112X4(R) =3X3 Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.000 D 999 360 Loc R+ / R- ! Rh / Rw / U / RL VERT(CL): 0.000 D 999 240 p* 110 /- /- A /- A HORZ(LL): 0.000 O - - P Brg Width = 219 Min Req = - HORZ(TL): 0.000 O Bearing AD is a rigid surface. Creep Factor: 2.0 Bearing AD requires a seat plate. Max TC CSI: 0.085 Maximum Top Chord Forces Per Ply (Ibs) Max BC CSI: 0.009 Chords Tens.Comp. Chords Tens. Comp. Max Web CSI: 0.032 A- B 3 0 H- 1 2 0 Wgt: 109.2 Ibs B- C 10 0 1-1 2 0 C-D 2 0 J-K 2 0 VIEW Ver: 19.01.00A.0618.16 D- E 2 0 K- L 2 0 E-F 2 0 L-M 2 0 F-G 2 0 M-N 8 0 G-H 2 O N-O 3 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. AD -AC 0 -3 W- V 0 -2 AC -AB 4 0 V- U 0 -2 AB -AA 0 -2 U-T 0 -2 AA-Z 0 -2 T-S 0 -2 Z-Y 0 -2 S-R 0 -2 Y-X 0 -2 R-Q 4 0 X-W 0 -2 Q-P 0 -3 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A -AD 0 -70 P-O 0 -15 AC-C 0 -19 O-P 0 -34 M-Q 0 -18 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. B-AC 0 -129 I-V 0 -133 C-AB 0 -121 J-U 0 -134 D-AA 0 -138 K-T 0 -132 E-Z 0 -132 L-S 0 -137 F-Y 0 -134 R-M 0 -126 G-X 0 -133 Q-N 0 -109 H-W 0 -133 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seat on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Manuel Martinez, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field # 047182 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Or guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss St Cloud, FL 34771 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (:nnvrinht a)2n16 A-1 in anv formRnnf TniceeA. IJob Truss Truss Type Qty Ply 0111712020 ARMSSMB1 L I FL03 I SY42 2 11 I 2512 2,6" --� (TYP) 911.18 11,8" =3X4 1.5X3(R) =4X8 =3X4 W=3X6 3"1 S A B C D E F G H 1.5X3(R) T 3t' 1 Q P O N =3X6 =3X12 W=H0312 =3X4 =3X4 2r5" SEAT PLATE REQ. AL 20'7"8 Loading Criteria (pst) Wind Criteria TCLL: 40.00 Wind Std: NA TCDL: 10.00 Speed: NA mph BCLL: 0.00 Enclosure: NA BCDL: 5.00 Category: NA EXP: NA Kzt: NA Des Ld: 55.00 Mean Height: NA ft NCBCLL: 0.00 TCDL: NA psf Load Duration: 1.00 BCDL: NA psf Spacing: 24.0 " MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Lumber Top chord 4x2 SP M-30 :T2 4x2 SP #2: Bot chord 4x2 SP M-30 Webs 4x2 SP #3 Plating Notes All plates are 1.5X3 except as noted. Puriins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 20.38 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Deflection Max JT VERT DEFL: LL: 0.50" DL: 0.25". Additional Notes .END + continuous strongback. Truss must be installed as shown with top chord up. - 20'7"8 if =4X8 1112X4 I J K M L =3X12 =3X8 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.501 E 482 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.631 E 382 240 R 1120/- FT/RT:10(0)/10(10) HORZ(LL): 0.063 L - - L 1135/- Plate Type(s): HORZ(TL): 0.087 L R Erg Width = 7.5 Min Req = 1.5 WAVE, HS Creep Factor: 2.0 L Erg Width = - Min Req = - Max TIC CSI: 0.934 Bearing R is a rigid surface. Max BC CSI: 0,839 Bearing R requires a seat plate. Max Web CSI: 0.781 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Wgt: 110.6 Ibs A -B 1 0 F-G 0 -4538 VIEW Ver: 19.01.00A.0618.16 B- C 0 -3514 G- H 0 -4538 C-D 0 -3514 H-1 0 -3510 D- E 0 -4540 I- J 0- 3510 E-F 0 -4549 J-K 3 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. R- Q 2030 0 O- N 4549 0 Q- P 4338 0 N- M 4346 0 P- O 4338 0 M- L 2028 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. S-T 0 -4 F-N 51 -437 A-R 0 -110 N-H 691 -121 R- B 0- 2255 H- M 0 - 925 B-Q 1641 0 1 - M 0 -258 C- Q 0- 258 M- J 1638 0 Q-D 0 -911 J -L 0 -2255 D-O 663 -124 L-K 0 -15 O-E 37 -366 K-L 0 -114 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Manuel Martinez, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field f1047182 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss St Cloud, FL 34771 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. r:nnvrinht 02n16 A-1 Roof Tmcsas— R—rnrinntinn of IhN do-mentin anv fnrnis nmhihitnd without tha wnften nannic inn of AA Roof Tnresec. ARMSSMB1L I FL03GE rtuaa iyp. SY42 5y 11y ( vuf i „zu" 2547 !-- 1'4" (T'P) E-- 1'3"4 " i - 2T'4 1111"4 127A 1112X4 =3X3 =3X3 1112X4 A B C D E F G H I J K Loading Criteria (psf) Wind Criteria TCLL: 40.00 Wind Sid: NA TCDL: 10.00 Speed: NA mph BCLL: 0.00 Enclosure: NA BCDL: 5.00 Category: NA EXP: NAKzt: NA Des Ld: 55.00 Mean Height: NA ft NCBCLL: 0.00 TCDL: NA psf Load Duration: 1.00 BCDL: NA psf Spacing: 24.0 " MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Lumber Top chord 4x2 SP #2 Bot chord 4x2 SP #2 Webs 4x2 SP #3 Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 12.38 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes .END + continuous strongback. Truss must be installed as shown with top chord up. L ;R) Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or `=PLF Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): 0.006 J 999 360 Loc R+ / R- / Rh / Rw / U / RL V* 216/- Rep Factors Used: No VERT(CL): 0.008 J 999 240 FT/RT:10(0)/10(10) HORZ(LL): 0.000 K - - L 212/- Plate Type(s): HORZ(TL): 0.000 K V Brg Width = 144 Min Req = - WAVE Creep Factor: 2.0 L Brg Width = 7.5 Min Req = 1.5 Max TC CSI: 0.337 Bearings V & M are a rigid surface. Max BC CSI: 0.196 Bearings V & M require a seat plate. Max Web CSI: 0.077 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Wgt: 81.2 Ibs A-B 6 O F-G 8 0 VIEW Ver: 19.01.00A.0618.16 B- C 20 0 G- H 8 0 C-D 8 0 H - 1 23 0 D-E 8 0 1-1 6 0 E-F 8 0 J -K 6 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp V-U 0 -6 Q-P 0 -8 U-T 5 0 P-O 0 -8 T-S 0 -8 O-N 4 0 S -R 0 -8 N-M 0 -6 R-Q 0 -8 M-L 0 -6 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-V 0 -147 L-K 0 -29 U-C 0 -36 K-L 0 -93 H-N 0 -39 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp B- U 0 -279 G- P 0 -302 C- T 0- 265 O- H 0 - 246 D- S 0- 299 N- I 0 - 335 E-R 0 -287 J -M 0 -119 F - Q 0 - 286 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TOD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I. (:nnvdnht n 2016 A-1 Rod Tni.,.-- Renmd-Am of this dnenme±nf. in anv form, N nrnhihited without fhe wdnen nenni-inn of A-1 Rnnf T.,-.., Manuel Martinez, P.E. # 047182 4620 ParkView Or St Cloud, FL 34771 luoU r Cuss I lubb I ype l.y rly uor 1 rr/uzu ARMSSMB1L I FL04 I SY42 1kt7 ( 1 2508 2,6„ (TYP) 91 "8 =3X4 1.5X3(R) =4X8 =3X4 W=3X6 3"1 A B C D E FG H T 1.5X3(R) 3"1 R Q P O =4X6 =3X12 W=H0312 =3X4 =3X4 SEAT PLATE REQ. 20'11" Loading Criteria (psf) Wind Criteria TCLL: 40.00 Wind Std: NA TCDL: 10.00 Speed: NA mph BCLL: 0.00 Enclosure: NA BCDL: 5.00 Category: NA EXP: NA Kzt: NA Des Ld: 55.00 Mean Height: NA ft NCBCLL: 0.00 TCDL: NA psf Load Duration: 1.00 BCDL: NA psf Spacing: 24.0 " MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Lumber Top chord 4x2 SP M-30 :T2 4x2 SP #2: Bot chord 42 SP M-30 Webs 4x2 SP #3 Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 20.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Deflection Max JT VERT DEFL: LL: 0.51" DL: 0.26". Additional Notes .END + continuous strongback. Truss must be installed as shown with top chord up. 20'11" m4X8 =1.5X3(R) I J K L 3"1 1.5X3(R) N .M 3"1 =3X12 =4X6 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L!# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.515 F 475 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.649 F 377 240 S 1137 /- /-!- FT/RT:10(0)/10(10) HORZ(LL): 0.066 M - - M 1137/- Plate Type(s): HORZ(TL): 0.090 M S Brg Width = 7.5 Min Req = 1.5 WAVE, HS Creep Factor: 2.0 M Brg Width = 3.5 Min Req = 1.5 Max TC CSI: 0.931 Bearings S & M are a rigid surface. Max BC CSI: 0.846 Bearing S requires a seat plate. Max Web CSI: 0.799 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp, Wgt: 109.2 Ibs A-B 1 0 F-G 0 -4675 VIEW Ver: 19.01.00A.0618.16 B- C 0 -3581 G- H 0 -4675 C- D 0- 3581 H -1 0- 3580 D- E 0 -4675 I- J 0 -3580 E-F 0 -4685 J -K 1 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. S- R 2063 0 P- O 4685 0 R- Q 4441 0 O- N 4444 0 Q- P 4441 0 N- M 2064 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. T-U 0 -4 F-O 26 -383 A-S 0 -110 O-H 699 -106 S- B 0- 2292 H- N 0 - 956 B-R 1678 0 1 - N 0 -257 C- R 0- 259 N- J 1676 0 R- D 0- 951 J- M 0- 2293 D-P 705 -106 K-M 0 -110 P-E 25 -388 L-V 0 -4 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineed responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I. Cnnvrinht �e 2n1n A-1 Rnnf Tnita"_c — Rnnrndnnlinn of this rlorahoent, in anv fnnn. is nrnhihitatl withmit the written ne, mission of A.1 Rnof Tnisses Manuel Martinez, P.E. # 047182 4620 ParkView Or St Cloud, FL 34771 Job Truss ARMSSMBI L 1 FL05 Truss Type I Qty I Ply 10611712020 2661 SY42 5 1 �— 2,6" (TYP) 1.5X3(R) =4X8 A B 3"1 T 1.5X3(R) 3"1 SEAT PLATE RED. Loading Criteria (psf) Wind Criteria TCLL: 40.00 Wind Std: NA TCDL: 10.00 Speed: NA mph BCLL: 0.00 Enclosure: NA BCDL: 5.00 Category: NA EXP: NA Kzt: NA Des Ld: 55.00 Mean Height: NA ft NCBCLL: 0.00 TCDL: NA psf Load Duration: 1.00 BCDL: NA psf Spacing: 24.0 " MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Lumber Top chord 4x2 SP M-30 :T2 4x2 SP #2: Bot chord 4x2 SP M-30 Webs 4x2 SP #3 Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 20.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Deflection Max JT VERT DEFL: LL: 0.51" DL: 0.26". Additional Notes .END + continuous strongback. Truss must be installed as shown with top chord up. 9'1 "8 1 11'8" 1 20'11" =3X4 =3X4 W=3X6 =4X8=1.5X3(R) C D E FG H I J K L 3„1 =1.5X3(R) R Q P O N M 3"1 =3X12 W=H0312 =3X4 =3X4 aa3X12 =4X6 SEAT PLATE REQ. 20'11" Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): 0.515 F 475 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.649 F 377 240 S 1137!- FT/RT:10(0)/10(10) HORZ(LL): 0.066 M - - M 1137 /- /- /- A !- Plate Type(s): HORZ(TL): 0.090 M S Brg Width = 7.5 Min Req = 1.5 WAVE, HS Creep Factor: 2.0 M Brg Width = 7.5 Min Req = 1.5 Max TC CSI: 0.931 Bearings S & M are a rigid surface. Max BC CSI: 0.845 Bearings S & M require a seat plate. Max Web CSI: 0.799 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Wgt: 109.2 lbs A-B 1 0 F-G 0 -4675 VIEW Ver: 19.01.00A.0618.16 B- C 0 -3581 G- H 0 -4675 C- D 0- 3581 H- I 0- 3580 D- E 0 -4675 I- J 0 -3580 E-F 0 -4685 J-K 1 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. S- R 2063 0 P- 0 4685 0 R- Q 4441 0 O- N 4444 0 Q- P 4441 0 N- M 2064 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp, Webs Tens. Comp. T-U 0 -4 F-O 26 -383 A-S 0 -110 0-H 699 -106 S- B 0- 2292 H- N 0 - 956 B- R 1678 0 I- N 0 - 257 C- R 0- 259 N- J 1676 0 R- D 0- 951 J- M 0- 2293 D-P 705 -106 K-M 0 -110 P- E 25 -388 L- V 0 -4 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Manuel Martinez, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 047182 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss St Cloud, FL 34771 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (:nnvrinht (.) 201fi A-1 Rmf Tnrcsr_s— RrnmrinrJinn of this Anrarment. in anv form. i� nrnhihiteA vrithnnl the written nnmriscinn of A-1 Rnnf Tni. anx. Job ARMSSMB1 L Truss Truss Type FL06G ISY42 1ty (y (06/17/2020 1 2676 MIC -490#-490# -490# -490# -490# -490# -490# �^- 5'1"12 T 1' 4 - 17"8 4- 2' --�- 2' �^- 2' - -- 2' --F 61"12 2'6" (TYP) =5X14 8 9'0"12 m5X8 D E =5X10 W=H0312 F G u 20'11" =5X12 i 9'0"12 10 7 4 20'8" 2q''41" 1'3"8 I SEAT PLATE REQ, SEAT PLATE REQ. tC- 20'11" 1 Loading Criteria (psf) Wind Criteria Code / Misc Criteria TCLL: 40.00 Wind Std: NA Code: FBC 2017 RES TCDL: 10.00 Speed: NA mph TPI Std: 2014 BCLL: 0.00 Enclosure: NA Rep Factors Used: No BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) EXP: NA Kzt: NA Plate Type(s): Des Ld: 55.00 Mean Height: NA ft WAVE, HS NCBCLL: 0.00 TCDL: NA psf Load Duration: 1.00 BCDL: NA psf Spacing: 24.0 " MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Lumber Top chord 4x2 SP 2400f-2.0E :T2 4x2 SP M-30: :T4 4x2 SP #2: Bot chord 4x2 SP 2400f-2.OE :134 4x2 SP #2: Webs 4x2 SP M-30 :W1, W2 4x2 SP #3: Special Loads ---(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 pif at 0.00 to 100 plf at 5.02 TC: From 50 pif at 5.02 to 50 pif at 15.65 TC: From 100 plf at 15.65 to 100 plf at 20.67 BC: From 10 plf at 0.00 to 10 pif at 5.02 BC: From 5 plf at 5.02 to 5 pif at 15.65 BC: From 10 plf at 15.65 to 10 plf at 20.67 TC: -490 lb Conc. Load at 5.02, 6.02, 7.65, 9.65 11.65,13.65,15.65 Plating Notes All plates are 3X6 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 65 0.25 20.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes + 2x6 continuous strongback. Negative reaction(s) of -945# MAX. from a non -wind load Case requires uplift connection. See Maximum Reactions. Truss must be installed as shown with top chord up. Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): -0.626 F 391 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): -0.688 F 999 240 T - /-945 /- /- !- !- HORZ(LL): -0.060 B - - W - /-798 /- /- A /- HORZ(TL): 0.066 B T Brg Width = 7.5 Creep Factor: 2.0 W Brg Width = 7.5 Max TC CSI: 0.950 Bearings T & N are a rigid surface. Max BC CSI: 0.982 Bearings T & N require a seat plate. Max Web CSI: 0,488 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Wgt: 161.0 Ibs A-B 18 0 G-H 7301 0 VIEW Ver: 19.01.00A.0618.16 B- C 5739 0 H- I 4980 0 C- D 5739 0 1-1 4980 0 D- E 7313 0 J- K 4980 0 E- F 7322 0 K- L 20 0 F - G 7301 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp T- S 0 -2431 Q- P 0 -7322 S- R 0- 7230 P- O 0- 6800 R- Q 0- 7230 O- N 0- 2220 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp U-V 0 -11 F-P 377 0 A-T 0 -97 P-H 0 -555 T- B 2654 0 H- O 1975 0 B- S 0- 3592 1-0 393 0 C- S 668 0 O- K 0- 2997 S-D 1618 0 K-N 2375 0 D-Q 0 -116 L-N 0 -124 Q-E 160 0 M-W 11 0 .*WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Manuel Marfinez, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 4047182 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss St Cloud, FL 34771 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (:nnvd.ht n 201a A-1 Roof T....-- RonrodnNinn of thin doonmentin anv fnnn, is nmhihited tvifhont tha vmtfen nAroll-ion of A-1 Ronf Tniaan.¢. Job Iuss ARMSSMB1 L FL07GE I russ I ype SY42 �-- 1'4" —� (TYP) 01y Ply 11611712020 1 I1 '-- 1'3"4 --1 3'11"4 — -1 5' --- A B C D E 3"1=1.5X3j— 7t 1.5X3(R) 3"1 ' 5' - -A 1.5X3(R) 3"1 1.5X3(R) I 3"1 REQ. 2486 Loading Criteria (psi) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF TCLL: 40.00 Wind Sid: NA Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: NA mph TPI Std: 2014 VERT(LL): 0.000 C 999 360 Loc R+ / R- / Rh / Rw / U ! RL BCLL: 0.00 Enclosure: NA Rep Factors Used: No VERT(CL): 0.001 C 999 '240 K' 223/- BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) HORZ(LL): 0.000 E - - G 79 EXP: NA Kzt: NA Des 00 Plate Type(s): HORZ(TL): 0.000 E - - K Big Width = 52.5 Min Req = - Mean Height: NA ft WAVE Creep Factor: 2.0 G Brg Width = 7.5 Min Req = 1.5 NCBCLL: 0.0.00 TCDL: NA psi Max TC CSI: 0.225 Bearings K & G are a rigid surface. Load Duration: 1.00 BCDL: NA psf " Max BC CSI: 0.010 Bearings K & G require a seat plate. Spacing: 24.0 MWFRS Parallel Dist: NA C&C Dist a: NA ft Max Web CSI: 0.058 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: NA Chords Tens.Comp. Chords Tens. Comp. Wgt: 30.8 Ibs I: NA GCpi: NA A- B 0 0 C- D 0 0 Wind Duration: NA VIEW Ver: 19.01.00A.0618.16 B- C 0 0 D- E 0 0 Lumber Top chord 4x2 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Bot chord 4x2 SP #2 Chords Tens.Comp. Chords Tens. Comp. Webs 4x2 SP #3 K-J 0 0 I -H 0 '0 Bracing J- 1 0 0 H- G 0 0 Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Maximum Web Forces Per Ply (Ibs) Fasten rated sheathing to one face of this frame. Webs Tens.Comp. Webs Tens. Comp. L-M 0 -10 E-G 0 -67 Plating Notes A- K 0 -106 F- N 0 -8 All plates are 1.5X3 except as noted. Purlins Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: B - J 0 -288 D - H 0 -252 Chord Spacing(in oc) Start(ft) End(ft) C -1 0 -298 BC 54 0.25 4.75 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes Truss must be installed as shown with top chord up -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C—H.ht nc 2016 A-1 Roof Tmssav — Renmdnntinn of thi<dnaimnnl. in env form. is nmhihHed withnnt the written nermicsinn of A-i Ronf Tncc Manuel Martinez, P.E. # 047162 4620 ParkView Dr St Cloud, FL 34771 Job Truss ARMSSMB1L FL08 Truss Type Qty Ply SY42 7 1 06/17/2020 2673 564#g �- 10.12 -1— 2'0"8 - -{ IIIA2X4 =4gX4 1112CX4 3"1 =1.5X3(R) "v 1.5X3(R) qF 3"1 D 1111.5X3 1113X3(R) E =3X6 T,� EAT PLATE REQ. 88�---�— f ---_ 2'0"8 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 40.00 Wind Std: NA Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: NA mph TPI Std: 2014 VERT(LL): 0.006 A 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: NA Rep Factors Used: No VERT(CL): 0.036 A 273 240 E 1275/- BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) HORZ(LL): -0.004 A - - D - /-576/- EXP: NA K& NA Plate Type(s): HORZ(TL): 0.024 A E Brg Width = 8.0 Min Req = 1.5 Des Ld: 55.00 Mean Height: NA ft WAVE Creep Factor: 2.0 D Br Width = - Min Re 9 q NCBCLL: 0.00 TCDL: NA sf p Max TC CSI: 0.167 Bearing E is a rigid surface. Load Duration: 1.00 BCDL: NA psf Bearing E requires a seat plate. Spacing: 24.0 " MWFRS Parallel Dist: NA Max BC CSI: 0.219 C&C Dist a: NA ft Max Web CSI: 0.295 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Loc. from endwall: NA Wgt: 23.8 Ibs I: NA GCpi: NA A- B 0 0 B- C 3 0 Wind Duration: NA VIEW Ver: 19.01.00A.0618.16 Lumber Maximum Bot Chord Forces Per Ply (Ibs) Top chord 4x2 SP 2400f-2.OE Chords Tens.Comp. Chords Tens. Comp. Bot chord 4x2 SP 2400f-2.0E F - E 0 -316 E - D 0 -316 Webs 4x2 SP #3 Special Loads Maximum Web Forces Per Ply (Ibs) -----(Lumber Dur.Fac.=0.90 / Plate Dur.Fac.=0.90) Webs Tens.Comp. Webs Tens. Comp. TC: From 80 pif at 0.00 to 80 plf at 1.92 G - H 0 -47 B - D 556 0 BC: From 10 plf at 0.00 to 10 plf at 1.92 A - F 0 -494 D - C 0 -15 TC: 564 Ib Conc. Load at 0.00 F - B 557 0 C - D 41 -1 Purlins B - E 0 -1090 In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 20 0.12 1.79 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Additional Notes Negative reaction(s) of -576# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. Truss must be installed as shown with top chord up. `"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. r:nnvdnht (t) 2016 A-1 Roof Tni. c — Ronrodnntian of this d—ronntin anv Mon. N nrohihitod without tho wriftnn nanni-ino of AA Roof Tnisces. Manuel Martinez, P.E. 4047182 4620 ParkView or St Cloud, FL 34771 Job ARMSSMB1 L I russ I russ I ype city wy HR HIP_ 2 1 1 Ub/1 //21.12U 2731 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP M-30 Webs 2x4 SP #3 Special Loads T 4, 3 -8# 2724 �- 1'5"8 --�--- 2715 14- 1 2715 - t- 2'8"11 --{ �- 1'11"13 -1 9110"1 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 ---(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 0 pif at -1.98 to 61 plf at -0.10 TC: From 2 pif at -0.10 to 2 plf at 9.84 BC: From 2 pif at 0.00 to 2 plf at 9.84 TC: -8 lb Conc. Load at 1.46 TC: 141 lb Conc. Load at 4.29 TC: 272 lb Conc. Load at 7.12 BC: 20 lb Conc. Load at 1.46 BC: 105 lb Conc. Load at 4.29 BC: 187 lb Conc. Load at 7.12 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 116 0.15 9.84 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. IC 4 d 105# 20# 187# Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.026 F 999 360 Loc R+ / R- / Rh / Rw / U / RL B 363 /- /- /- /228 /- Rep Factors Used: Varies by Ld C MERT(CL): 0.062 F 999 240 FT/RT:10(0)/10(10) HORZ(LL): 0.011 F - E 382 /- /- /- /129 /- Plate Type(s): HORZ(TL): 0.026 F D 69 /- /- /- /59 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0,595 B Brg Width = 4.9 Min Req = 1.5 Max BC CSI: 0.743 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.296 D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 39.2 Ibs Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 A-B 19 -13 C-D 51 -71 B - C 389 - 555 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B- F 545 - 348 F- E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 377 - 592 `*WARNING" Please thoroughly review the "A•1 ROOF TRUSSES ("SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional enginean responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building, All capitalized terms are as defined in TPI-1. Cnnvnoht 0 201 A A-1 Ronf Tmsse-s - Ren d-lion of fhi., d-i-f, in anv fnnn. is nrnWHIM without thn written nn.`micsinn of A-1 Roof Tot .e . Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Jon t russ I russ I ype Lary rry ub/I //zuZu ARMSSIM L J1 JACK 1 1 2722 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration:1.25 Spacing: 24.0" Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 12 C 6 � � 2X4(A1OB � ®LO 41-3 Lo A9 1 C Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 12 0.04 1.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 1 15119 �F 1' Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.000 D HORZ(TL): 0.000 D Creep Factor: 2.0 Max TC CSI: 0.346 Max BC CSI: 0.041 Max Web CSI: 0.000 Wgt: 5.6 Ibs VIEW Ver: 19.01.00A.0618.16 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 198 /- /- /177 /99 /56 D 10 /-7 /- /19 /14 /- C - /-21 /- /34 /35 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 39 0 B-C 44 -24 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 `*WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ('SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI-1. Cnnvnnht n 201a A-1 Rnnf Tnicsr-a — Renmri-Am of this d—imnntin —form. is nrnhihited withnnt thn wniten n nniscinn of A-1 Rnnf Tni— Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 JOD ARMSSMB1 L Iruss J3 I russ I ype ury my JACK 1 10 1 1 Ub/l //LULU 2737 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration:1.25 Spacing: 24.0" Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 C �- 1'5"9 -� 3' �{ Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 36 0.04 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.001 D HORZ(TL): 0.002 D Creep Factor: 2.0 Max TC CSI: 0.389 Max BC CSI: 0.082 Max Web CSI: 0.000 Wgt: 11.2 Ibs VIEW Ver: 19.01.00A.0618.16 0 r LO r L0 CV ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 234 /- /- 1181 /87 /109 D 53 /- /- /29 /- /- C 70 /- /- /39 /58 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 39 0 B-C 32 -89 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 *`WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design DmWng (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI.1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1, ronvnnht n 2016 A-1 Roof To— — Rennxludinn of this doon—ntin anv form, k nnobihitnd without rho written narmission of A-t Roof Tnicse". Manuel Martinez, P.E. f1047182 4620 ParkView Dr St Cloud, FL 34771 IJob ARK4SSMBIL Truss Truss Type J5 JACK I4Qty I 1Ply 06/17/2020 2728 Loading Criteria(psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 111 C �---- 1'5" 9 5' ml Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 60 0.04 5.00 Apply purlins to any chords above or below fillers at 24" CIC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Defi/CSI Criteria PP Deflection in loc L/defi L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0,006 D HORZ(TL): 0.011 D Creep Factor: 2.0 Max TC CSI: 0.344 Max BC CSI: 0,263 Max Web CSI: 0.000 Wgt: 18.2 Ibs VIEW Ver: 19.01.00A.0618.16 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 308 /- /- /224 /99 /161 D 92 !- /- 150 /- /- C 133 /- /- /79 /108 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 39 0 B-C 59 -108 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 `"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the Too, only Alpine connector plates shall be used for the TOD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TOD represents an acceptance of the professional engineer responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. Onnvdnht (a 2016 A-1 Rmf Tni4 -- RenrnAnrtinn of thin dncnmontin anv formis nmhihited Mth-t tha wdHen nonnixcinn of A-1 Rnnf Tn.— Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job ARMSSMB1 L I russ J5C I russ I ype city coy JACK 1 1 1 1 06/1 1/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NC13CLL: 10.00 Load Duration:1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 2X4(A1 T Wind Criteria Wind Sid: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Puriins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 60 0.04 5.00 Apply puriins to any chords above or below fillers at 24" OC unless shown otherwise above. "]I �- ---- 51 _I Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.007 C HORZ(TL): 0.014 C Creep Factor: 2.0 Max TC CSI: 0.371 Max BC CSI: 0.276 Max Web CSI: 0,000 Wgt: 15.4 Ibs, VIEW Ver: 19.01.00A.0618.16 M 0 N ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL A 208 /- /- /129 /41 /129 C 94 /- /- /56 /- A B 139 /- /- /86 /113 /- Wind reactions based on MWFRS A Brg Width = 3.5 Min Req = 1.5 C Brg Width = 1.5 Min Req = - B Brg Width = 1.5 Min Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-B 62 -110 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 0 0 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-I. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvn.ht 0) 2fNa AA Rnnf Tm.,,,-- Renrndnr]inn of this dnntmenfin anv fnnn. in nrnhihitnd withrn t the vmtten nermicvinn of A4 Rmf Tnicvee Manuel Martinez, P.E. # 047182 4620 PafkVlew Dr St Cloud, FL 34771 Job Truss Truss Type Qty Ply 06/17/2020 , I ARMSSMB1 L R I EJAC ( 1 I 1 2619 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP 42 T Wind Criteria Wind Sid: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: it EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 it Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.13 7.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(0)110(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. C 7r 0 Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh J Rw / U / RL A 294 /- /- /182 /60 /181 HORZ(LL): 0.017 C C 131 /- /- /78 /- /- HORZ(TL): 0.035 C B 194 /- /- /120 /158 /- Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.769 A Brg Width = - Min Req = - Max BC CSI: 0.535 C Brg Width = 1.5 Min Req = - Max Web CSI: 0.000 B Brg Width = 1.5 Min Req = - Maximum Top Chord Forces Per Ply (Ibs) Wgt:21.0lbs Chords Tens.Comp. VIEW Ver: 19.01.00A.0618.16 I A - B 87 -140 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 0 0 *'WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the Too, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineed responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I. (:n—iriht t72016 A-1 Roof T.-- Renrodnotinn of this dnonment in env form. N nrohihited with-t the written nermi-inn of A-1 Roof To—, Manuel Martinez, P.E. N 047182 4620 ParkView Dr St Cloud, FL 34771 JOD ARMSSMB1 L 1 russ I russ I ype t.ity r1 L01 I GABL ( 1 11y uo/ I //LULU Mi Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 E -- 8'3"6 -{- 8'3"6 --1 T T Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Bracing Fasten rated sheathing to one face of this frame. Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.00 16.56 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for gable wind bracing requirements. F G=3X4 Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.004 G 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): -0,006 B 999 240 X* 83 /- /- /43 /30 /10 HORZ(LL): -0.038 B - - N 221 /- /- 1121 /133 A HORZ(TL): 0.056 B Wind reactions based on MWFRS Creep Factor: 2.0 X Erg Width = 191 Min Req = - Max TC CSI: 0.313 N Brg Width = 7.4 Min Req = 1.5 Max BC CSI: 0.156 Bearings X & O are a rigid surface. Max Web CSI: 0.193 Bearings X & O require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:91.0lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 I A - B 43 0 G - H 382 -37 B - C 193 - 82 H - I 338 - 40 C - D 239 - 52 I - J 259 - 55 D-E 310 -41 J -K 201 -69 E-F 392 -37 K-L 187 -116 F-G 315 -34 L-M 43 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp X - W 89 -77 S - R 84 -76 W-V 86 -76 R-Q 83 -75 V - U 85 -76 Q - P 83 - 74 U - T 84 - 75 P - O 84 - 72 T - S 84 -76 O - N 77 -69 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp X-B 387 -195 R-H 177 -128 C-W 91 -79 Q-1 172 -123 D-V 144 -131 P-J 121 -119 E-U 251 -123 O-K 114 -69 F-T 0 -180 L-N 390 -216 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineed responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in wdfing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. r;nnvd.ht n 2016 A-1 Roof Tnlveaa- Renmduntion of thlc domimentin anv formis nmhihitad Wihnut tha wfiHan nermiacion of AA Roof To—, Manuel Martinez, P.E. # 047182 4620 ParkView Or St Cloud, FL 34771 IJob ARMSSMB1 L Truss I cuss Type Uty Hly L02 I SPEC 15 11 U6/"I //2U21.1 2740 Loading Criteria (psi) TCLL: 20.00 TCDL 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " T T f -- 8'3"6 g3"6 t SEAT PLATE RED. SEAT PLATE REQ. 16'6"12 �- 1'6"3 -{ Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x4 SP 42 Webs 2x4 SP #3 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 93 0.00 16.56 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.016 G 999 36 VERT(CL): 0.032 G 999 24 HORZ(LL): 0.005 D - HORZ(TL): 0.007 D Creep Factor: 2.0 Max TC CSI: 0.522 Max BC CSI: 0.907 Max Web CSI: 0.658 Wgt: 91.0 Ibs VIEW Ver: 19.01.00A.0618.16 f- 1'6"3 - ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL H 773 /- /- /644 /266 /151 1 773 /- /- /473 /240 /- Wind reactions based on MWFRS H Erg Width = 7.4 Min Req = 1.5 1 Erg Width = 7.4 Min Req = 1.5 Bearings H & I are a rigid surface. Bearings H & I require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- B 40 0 C- D 866 - 837 B-C 916 -837 D-E 40 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. H - G 247 -166 G - F 92 -122 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - H 848 - 705 G - D 571 - 501 B-G 571 -514 D-F 714 -705 G - C 472 - 322 —WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TOD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless othervnse defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrinht 0 2a1e A-1 Rnnf Tnicsa_s— RnnmdnNion of this d—anent. in anv fnnn. is nmhihitad mth-t tha wdttan nannissinn of A-1 Rnnf Tnissas Manuel Martinez, P.E. # 047182 4620 ParkView Or St Cloud, FL 34771 Job ARMSSMB1 L I russ Truss type G2ty PIy Vol I VAL 11 1 06/17/2020 2616 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Pt1M_ 1r3R9 _ 1r3r19 P Ia 15 -Y 12 6 B = 3X4 T 5A2X4(D8R) 2X4(D8CR) Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 45 0.00 3.75 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for valley details. 319111 Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.003 999 360 VERT(CL): 0.007 999 240 HORZ(LL): -0.001 - - HORZ(TL): 0.002 Creep Factor: 2.0 Max TC CSI: 0.065 Max BC CSI: 0,098 Max Web CSI: 0,000 Wgt: 11.2 Ibs VIEW Ver: 19.01.00A.0618.16 ♦ Maximum Reactions (Ibs), or *=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL D* 82 /- /- /33 /17 /4 Wind reactions based on MWFRS D Erg Width = 45.0 Min Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 140 -170 B-C 140 -170 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 166 -104 "WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI.1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building, All capitalized terms are as defined in TPI.1. Convnnht g�) 2a1a A-1 Rnnf Tni. sP_ — Rrtnrndn Jinn of thin domiment, 1n anv form. is nrohn,M.d WthnnI fhe tvr'i t.n rwnnicvinn of AA Ronf T.,cse,. Manuel Martinez, P.E. # 047182 4620 ParkView Or St Cloud, FL 34771 Job Truss ARMSSMB1 L V02 Truss Type VAL 2y I1y ( 0611712020 2622 T 1 6"15 P � 3'3"9 12 B=4X4 3'3°9 '1' 1-" I- 719n1 _I F 3'8"12 i}1 3,8"12 --� Loading Criteria (pst) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.006 D 999 360 Loc R+ / R- / Rh / Rw / U / RL E* 82 /- /- 139 /24 /6 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.013 D 999 240 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.003 D - - Wind reactions based on MWFRS EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.005 D E Brg Width = 93.0 Min Req = - Des Ld: 40.00 Mean Height: 25.00 ft WAVE Creep Factor: 2.0 Bearing A is a rigid surface. NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Max TC CSI: 0.221 Maximum Top Chord Forces Per Ply (Ibs) Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.183 Chords Tens.Comp. Chords Tens. Comp. A - B 215 -221 B - C 215 -221 C&C Dist a: 3.00 ft Max Web CSI: 0.145 Loc. from endwall: Any Wgt: 25.2 Ibs GCpi: 0.18 Maximum Bot Chord Forces Per Ply (Ibs) VIEW Ver: 19.01.00A.0618.16 Wind Duration: 1.60 Chords Tens.Comp. Chords Tens. Comp. Lumber A - D 304 -157 D - C 304 -157 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Purlins B - D 486 -335 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 7.75 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for valley details. **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI.1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C.—Mht cfl MIA A-1 Rnnf Tnta -- R"nrnduntinn of thia dom iment. in anv f— is nrohihitvd withnnt the written neenisMan of A-1 Rnnf Tni— Manuel Madinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 JUNE 20, 2019 ( TYPICAL HIP / KING JACK CONNECTION I STDTL01 CORNERSET GENERAL SPECIFICATIONS Aow MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 3494£ Attach King Jack w/ (3) 16d Toe 772-409-1010 Nails @ TC & BC Attach End Jack's Attach Corner Jack's w/ (4) 16d Toe Nails @ TICQ w/ (2) 16d Toe Nails @ TIC& & (3) 16d Toe Nails @ BC 2 BC (Typ) 0 ti ttach Corner Jack's i/ (2) 16d Toe Nails @ TIC & BC (Typ) Manuel Mart nez, RE, # 047182 462D ParkView Dr St Cloud, FL 34771 FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL 1 STDTL03 A-1 ROOF TRUSSES 4451 ST, LUCIE BLVD, FORT PIERCE, FL 34946 772409-1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD 1'-3'MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES 24' O.C. 2X6 DIAGONAL BRACE SPACED 4B' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). ' PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \ BRACE AND THE TWO TRUSSES ON \EITHER SIDE AS NOTED. TOENAIL \ BLOCKING TO TRUSSES WITH (2) - \ 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. END WALL CEILING SHEATHING STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131' X 3') NAILS SPACED 6' O.C. - FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-9B, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM). STRUCTURAL GABLE TRUSS MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED / STUDS. TRUSSES WITHOUT INLAYED STUDS ARE NOT ADDRESSED HERE. STANDARD GABLE / I- TRUSS UKAL TRUSS 3illml AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. Manuel Martinez, P.E. # 047182 4620 ParkUew Dr St Cloud, FL 34771 12/23/19 PIGGY -BACK TRUSS STDTL 4.1 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. PORT PIERCE, FL 34946 772.409-1010 PIGGY -BACK DETAIL (TYPICAL) 180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. 160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. IMPORTANT NOTE: TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS. MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C. DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA, STEEPLE, CHIMNEY OR DRAG STRUT LOADS. **REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE TRUSS SPECIFICATIONS.** PIGGY -BACK TRUSS. (REFER TO ACTUAL TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) 2-0" MAX OPTION NO. 1 - TEE-LOK 3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH 6d (1.5" X 0,099") NAILS IN EACH PLATE TO ACHEIVE MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8" TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2 PLATES). OPTION NO.2 - APA RATED GUSSET: 8" x 8" x 0-7/16' (MIN.) APA RATED SHEATHING GUSSETS EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d COMMON (0.1 13" x 2") NAILS PER GUSSET: 4 (EACH) AT CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION NO.3 - 2X4 VERTICAL WOOD SCAB: 2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE. ATTACH AT 8'-0" O.C. w/6 (EACH) 1 Old BOX NAILS (0.128" x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND 3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE STAGGERED 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION #1: TEE-LOK MULTI -USE CONNECTION PLATE. OPTION #2: APA RATED GUSSET. OPTION #3: 2X4 VERT. SCAB. ATTACH EACH PURLIN TO TOP CHORD OF BASE TRUSS. PURLIN & CONNECTIONS BY OTHERS. BASE TRUSS. (REFER TO TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) PURLINS SPACED ACCORDING TO MAX. SPACING OF TOP CHORD OF BASE TRUSS. SPACING IS NOT TO EXCEED 24" O.C. & PURLINS TO BE LOCATED AT JOINT OF EACH BASE TRUSS. ** IMPORTANT NOTE ** THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES SPACED AT 24" O.C. OR LESS. Manuel Martinez, P.E. # 047182 4620 ParkVew Dr J U LY 17, 2017 TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409.1010 VALLEY TRUSS (TYPICAL) SECURE VALLEY TRUSS WI ONE ROW OF 10d NAILS 6" O.C. GENERAL SPECIFICATIONS: 1. NAIL SIZE = 3" X 0.131" = 10d 2. WOOD SCREW = 4.5" SDS25412 SIMPSON OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL "A". 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NDS - 01. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. TRUSS, OR GIRDER TRUSS BASE TRUSSES -C CIVV, %'UIVIIVIUIV 3S, OR GIRDER TRUSS TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24" O.G. (BASE AND VALLEY) SYP TO THE ROOF W/ TWO MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. SIMPSON SDS25412 (1/4" X 4.5") OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. Manuel Martinez, P.E. d 047182 4620 ParkView Dr St Cloud, FL 34771 FEBRUARY 5, 2018 j TRUSSED VALLEY SET DETAIL I STDTL06 -' A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 SECURE W/( VALLEY TRUSS (TYPICAL) GABLE END, COMMON TRUSS, OR GIRDER TRUSS LJ I ! 1" ! (NO SHEATHING) N.T.S. GENERAL SPECIFICATIONS: 1. NAIL SIZE = 3" X 0.131" = 10d 2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL „A„ 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. 6. NAILING DONE PER NOS - 01. 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. P 12 SEE DETAIL "A" BELOW (TYP.) BASE TRUSSES GABLE END, COMMON TRUSS, OR GIRDER VALLEY TRUSS TRUSS (TYPICAL) WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS #2 MAX TOP CHORD TOTAL LOAD = 50 PSF SYP TO THE ROOF W/ TWO MAX SPACING = 24" O.C. (BASE AND VALLEY) SIMPSON SDS25300 (1/4" X 3") MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. Manuel Martinez, P.E. # 047182 4620 ParkView Or St Cloud, FL 34771 DULY 17, 2017 I F F` (HIGH WIND VELOCITY) n�L I STDTL07 A-1 ROOF TRUSSES 4451 ST, LUCIE BLVD, FORT PIERCE, FL 34946 772409-1010 ATTAC WIND DESIGN PER ASCE 7-98, ASCE 7-I WIND DESIGN PER ASCE 7-10: 170 MPt MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE:' MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24" O.C. (BASE AND VA SUPPORTING TRUSSES DIRECTLY UNDmm VHLLr-T I KUOOCO IVIUO I esc DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 10" ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MAY BE APPLIED TO THIS FACE UP TO A NON -BEVELED MAXIMUM 6/12 PITCH BOTTOM CHORD U I NON -BEVELED BOTTOM CHORD CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6/12 (MAXIMUM 12/12 PITCH) 000 # 047182 4620 ParkView Dr St Cloud, FL 34771 FEBRUARY 17, 2017 1 STANDARD GABLE END DETAIL 1 STDTL08 A-1 ROOF TRUSSES 4451 ST, LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS W/lOd NAILS, 6' O.C. V ER1 STUD SECTION B-B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. BRACE 4' - 0' O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 Q VARIES TO COMMON TRUSS 3X4 = v * DIAGONAL BRACING ** L - BRACING REFER REFER TO SECTION A -A TO SECTION B-B 24' MAX. NOTE: 1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6' D.C. 5. DIAGONAL BRACE TD BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM AT4'-0'D.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN WITH 16d NAILS SPACED 6. O.C. HORIZONTAL BRACE TO BE LOCATED AT THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A) 7 GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240 VERTICAL 2X6 SP OR SPF STUD #2 DIAGONAL BRACE (4) - 16d NAILS 16d NAILS SPACED 6' O.C. (2) lOd NAILS INTO 2X6 2X6 SP OR SPF #2 2X4 SP OR SPF #2 TYPICAL HORIZONTAL BRACE NAILED TO 2X4 VERTICALS SECTION A -A W/(4) - 10d NAILS PROVIDE 2X4 BLOCKING BETWEEN THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS (4) Bd NAILS MINIMUM, PLYWOOD SHEATHING TO 2X4 STD SPF BLOCK 12' MAX. r=3 i B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAL. BRACE S. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10. 10d AND 16d NAILS ARE 0.131'X3.0' AND 0.131'X3.5' COMMON WIRE NAILS RESPECTIVELY. 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSC. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4 SP 431 STUD 12" O.C. 3-8-10 5-6.11 6.6.11 11.1-13 2X4 SP #3 / STUD 16" O.C. 3.3-10 4.9.12 6-6-11 9-10-15 2X4SP#31STUD 24"D.C. 2-8.6 3.11-3 5.4-12 8.1-2 2X4 SP #2 12" O.C. 3-10-15 5.6.11 6.6.11 11.8-14 2X4 SP #2 16" O.C. 3.6.11 4-9-12 6-6-11 10-8-0 2X4SP#2 24"0.C. 3.1-4 1 3-11-3 6.2.9 L 9-3.13 DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH 10d NAILS 6' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER 90% OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. ROOF SHEATHING VII (2) - 10d NAILS ]TRUSSES @ 24' O.C. 2X6 DIAGONAL BRACE SPACED 46' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d NAILS. HORIZONTAL BRACE (SEE SECTION A -A) END WALL MAX MEAN ROOF HEIGHT = 30 FEET EXPOSURE B OR C ASCE 7.10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS. Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 4 FEBRUARY 17, 2097 I TsBRACE WITH 2XIBRACEEONL.Y DETAIL I ST0TL09 NOTES: T-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T-BRACE / I -BRACE MUST COVER 90% OF WEB LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2X8 10d 6" O.C. NOTE: NAIL ALONG ENTIRE LENGTH OF T-BRACE / I -BRACE (ON TWO-PLY TRUSSES NAIL TO BOTH PLIES) NAILS BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2X8 T-BRACE 2X8 I -BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2X8 T-BRACE 2X8 I -BRACE T-BRACE / I -BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS WEB NAILS NAILS WEB SECTION DETAILS ; ,uelMarina,RE. # 047182 4620 ParkView Dr St Cloud, FL 34771 FEBRUARY17,2017 1 LATERAL BRACING RECOMMENDATIONS I STDTL10 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR TRUSS. M NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW. 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE 7724408-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT USE METAL FRAMING ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) ANCHOR TO ATTACH WEB WITH (3) - 10d SCAB WITH (3) - 10d TO TOP CHORD NAILS (0.131' X 3') NAILS (0.131' X 3'). ATTACH TO VERTICAL NAILS (0.313WITH )X 3') BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK USE METAL FRAMING ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) - 10d TO BOTTOM CHORD NAILS (0.131' X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0.131' X 3') IN EACH CHORD ATTACH TO VERTICAL SCAB WITH (3) - 10d NAILS (0.131' X 3') TRUSS 2X6 4' - 0' WALL STRONGBACK (TYPICAL SPLICE) (BY OTHERS) ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (0.216' DIA.) INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT USE DRYWALL TYPE SCREWS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0,131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) Manuel Mart nez' P.E. # 047182 4620 ParkView Dr FEBRUARY17,2017 I LATERAL TOE -NAIL DETAIL I STDTL11 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD, FORT PIERCE, FL 34946 772-409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SIR OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 o0 .135 93.5 85.6 74.2 72.6 63.4 162 108.8 99.6 86.4 84.5 73.8 ri .128 74.2 67.9 58.9 57.6 50.3 0 p 0 .131 75.9 69.5 60.3 59.0 51.1 .148 81.4 74.5 64.6 63.2 52.5 N Ni VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0.162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 1.15: 3 (NAILS) X B4.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30° TO 60° 45.00' ANGLE MAY VARY FROM 30° TO 60° THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW.11 VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. SIDE VIEW (2X3) 2 NAILS 1 NEAR SIDE NEAR SIDE SIDE VIEW (2X4) 3 NAILS NEAR SIDE -i NEAR SIDE NEAR SIDE 45.00' SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE )0° Manuel M4rtinez, P.E. # 047182 4620 ParkUew Or St Claud, FL 34771 FEBRUARY 17, 2017 LATERAL TOE -NAIL DETAIL STDTL11 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL ................ BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. A•1ROOF TRUSSES 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO 4451 ST. LUCIE BLVD. SPECIES FOR MEMBERS OF DIFFERENT SPECIES. FORT PIERCE, FL 34946 772-409-1010 TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 o .135 93.5 85.6 74.2 72.6 63.4 J .162 108.8 99.6 86.4 84.5 73.8 ri .128 74.2 67.9 58.9 57.6 50.3 c� .131 75.9 69.5 60.3 59.0 51.1 Z 0 J .148 81.4 74.5 64.6 63.2 52.5 N ri VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0.162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 1.15: 3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30° TO 60° 45.00' ANGLE MAY VARY FROM 30' TO 60° THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE SIDE VIEW (2X4) 3 NAILS -I NEAR SIDE NEAR SIDE NEAR SIDE 45.00' SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE )0° Manuel MNnez, P.E. # 047182 4620 ParkViiew Or St Cloud, FL 34771 TYP W NAILER ATTACHMENT I STDTL13 F A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 -1.0 x 4 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS. MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. Manuel Marlinez, P.E. # 047182 4620 ParkView Dr April 11, 2016 TYPICAL ALTERNATE BRACING DETAIL FO EXTERIOR FLAT GIRDER TRUSS STDTLI4 V __ A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 349, 772-409-1010 (4) 12d TRUSS 2411 O.C. UPLIFT CONNECTION (SEE ROOF TRUSS) 0 12 VARIES [�� (4) 12d MAX 3011(2'-611) 2x6 #2 SP (Both Faces) 24" O.C. SIMPSON H5 Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 rm FEBRUARY 17, 2017 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDTL15 DAMAGED OR MISSING CHORD SPLICE PLATES 4 A•1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK X (INCHES) MAXIMUM FORCE (LBS) 15% LOAD DURATION SP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24" 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30" 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36' 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42" 3169 4754 2900 4350 2451 3677 2511 3767 44 66 0. 3657 5485 3346 5019 2829 4243 2898 4347 DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (.131' OIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' D.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT AND A MINIMUM OF G' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE). DO NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. Manuel Martinez, P.E. #047182 6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. 4620 ParkView Dr St Cloud, FL 34771 FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS ( STDTL16'p,. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 TRUSS CRITERIA: LOADING: 40-10-0-10 DURATION FACTOR: 1.15 SPACING: 24' O.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END BEARING CONDITION NOTES: 1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148' DIA. X 3') SPACED 6' D.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. jNjff1j7;j 0, >, 1 THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771