HomeMy WebLinkAboutBuilding PlansGulf Coast Supply and MFG Sv Cnmp Metal roof mg FL 111451.12
24 go. 5v crimp metal roofing attached to plywood "deck using tt9 x I.5"
wood screws with self sealing washer at 12" o.c, max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and L" end
aps fastened with corrosion resistant tin caps and with '1.2 " ring shank nails
spaced L" o.c. at all laps and two staggered rows 12" o,c. field. Attach
deck to trusses using attachment dotal on this sheet
5/8" thick fight textured ZZ
stucco on typical concrete 12
block construction SLOPE 4
3 L� COVERED
PORCH
_______-_ __-__ __ ___ _ _____
5/8" thick x 8"w cut Finish Columns with
coral finished stucco bands
5/8" thick cut coral
finished stucco bands
IG HT 1_EVAT10N
12
4 1 SLOPE
SCALE: 1/4" = I'-O"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
24 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin ceps and with 1,21' ring shank nails
spaced L" o.c. at all Is and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
SCALE: 1/4" = 1'-0"
Product Approval Submittal Affidavit
Opening schedule Swing Doors, Overhead Doors, Sliding Doors, Windows k Skylights
Opening
Type
NOA/FL
NUMBER
Product
Model
Manufacturer
Glass
Attachment method
ap iration
Date
Design Pressure
of Approved Tests
1,2.3
t4
FLU 11499.2
Single Hung
Series 185
Min Windows
and doors
i x con. ml tn et on et mex
rpm sag corner end 6�o.c. ttaee�trr tiro igh �� (Suck into solid
filled Cifu wall mamtarmng min 2.5" edge distance m strict adherence
to the product aipproval.
+ 60 pat
-
A
Il-Ii06.30
Overhead
Garage Door
9
Model 824/811
9'-4" max. width
IC-o" max height
¢
DAB
nea . &- 5TF 5"k to tonerete bWk with r e e wt
1) e5 b'r Vert, wng 3/8' x 1" Alp HLC 91ove arxho. at a' o.c.
th 1. 6 el auh a knh inn. �' sag detente Imgqa,f trxk to buck
no ?> SAt iYie Id throd leg a rase m sash 1 ackat eemtwmng
mm..dl fi adet Aetame -GC to RrrQnsr fdg adhere to product approval
ID-9-21
50:0/-LO.O sf
p
B
FLU 19614.1
Fiberglass
Design Pro/
Smooth Pro
Jeld-Wan
Eko 1/4" din. tapcon with min 1.25" embedment at 3" max
from corners and 11.5" o.c. max. thereafter in head and jambs.
50.0 PSF
C
FLU 15332.2
SlidingGlass
Door
Serlea 420
MI WindOWa
and doors
,e. x can�nrri� penst1.ration at maxi
roe each corner ando.c. sal eouble rou Lhereefter throug�
PT Buck into solid filled CMU well memtnrnng min 2.5" edge distance
in strict adherence to the roduct a rovill.
4B.2 PSF
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
T
Kfeiration
Dade
Design Pressure
f Approved Tests
Mullions
FLU 15353.8
CM-18531
vertical mullion
+ mr CMU use (2) 1/4" x 2 3/4" tapcons with min 1 1/4" embedment
Mi Windows a ;" etratdon into each Mull Clip. Attach mull to clip using (4) #10 x 1,25"
and doors 4 ., 1f tapping screws per clip as shown m product approval.
a;
-.
+ 118.9 PSF
-
Roof
FLU II451.12
5V Crimppa.
Metal RoofingGulf
5v crimp metal roofing attached to plgmood deck using 49 x 1.5"
Coast Supply s, oo screws with self sealing washer at 12' o.c. max spacing over ASTM D
and manufacturing J type 2) 30 lb felt underlayment installed with min. 4 side laps and L" and
(Mpe fastened with corrosion resistant tin ceps and with 1.25" ring shank nods
'. spaced 4 o.c. at all laps and two staggered rows 12" o.c. in field. Attach
ydeck to trusees using attachment detail on roof plan
- 108.5 PSF
Siding
stucco on Block
Soffit
FLU 12198.3
Model T4 12" vented
Vinyl Soffit
Kagcan
Install using 2" x 2" battens at L" o.c, screwed to soffit framing using
tt8 x 3" wood screws at each truss. Install soffit to battens using
OJ2" dia. x 1.5 Iona rina shank nails with 3/8" dia. head,
55.0/-35.0 PSF
Hurricane
Panels
Fitt 15014.2
24 Gauge
Storm Panels
Global Protection
Products LLC
Install using 1/2" din. solid set lead anchors with 1/4" die.-20 z 1.5"
long SS screw head combo. with Neoprene washer at 12 1/2" o.c.
along the bottom and 13" o.c. at the top
± 45.0 PSF
I have reviewed the above and
approved it by my seal below. ( Architect or Engineer of Record )
2" x 4" top plate'
i
� 1019
� pet st'4ad® O vV 7
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411451.12 R
24 ga. 5v crimp metal roofing attached to plywood (deck using 49 x 1.5" COMPL�p►NC
wood screws with self sealing washer at 12" o.c, ma> spacing over ASTM D CODE
(type 2) 30 lb felt underlayment installed with min. 4' side laps and L" end N
spa
laps fastened with corrosion resistant tin caps and 6th 1.25" ring shank nails
S'�, LUCIE COU
ced L" o.c. at all laps and two staggered rows 1,2" o.c. in Field. Attach BOCC
deck to trusees using attachment detail on this sheet
i
11
rO'�
- EARIN
...
r
FILE COD
-O" = Finished Floor
5/8" thick light textured
stucco on typical concrete 5/8" thick x 8"w cut
block construction coral finished stucco bands
REAR EL_EVAT10N
SCALE: 1/4" = 1'-0"
12"
.H.
5/8" thick x 8"w cut'
coral finished stucco bands
\ 1/2" drywall ceding on truss bottom cord
1/2" drywall on
2" x 4" studs at 14" o.c.
12
4 1 SLOPE
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411451.12
24 ga. 5v crimp metal roofing attached to plywood "deck using tt9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 la felt underlayment installed with min. 4' side laps and 6" end
laps fastened uath corrosion resistant tin caps and with 1.25" ring shank nails
spaced L" o.c. of all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
\ one layer of 15 lb felt using nails. Substrate
n
to be I9/32" CDX Plywood nailed at L" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
8'-I" BEARING
�.
® ® ® ® � 1 ® ® T
®T ®® l L 17,
®®®® O'-O" Finished Floor
FRONT ELEVATION
base -board -1-1 2" x 4" P.T. bottom plate
4' concrete slab with fibermesh
OR
VxV #10/10 WWM on L mill Visqueen
over
clean compacted termite treated
Fill
Interior Non -Bearing Partition
nts
Braden it Braden AIA, PA
Wynne
Building Corp.
Architects - Planners-
&" 417 S.E. Coconut Avenue
THE
I I I 11� I�l'ID S O f
7 1 (q Tel : (2) 281-8258
W I J
j Fax : -(712) 281-8283
Spanish
Likes
E-mail: bradenaiaacomcast.net
St.
Lucie
County Florida
Stuart FL 34996 #AAC000032
SCALE: 1/4" = 1'-0"
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Budding Code Residential: Lth Edition and ASCE 1-10 for Wind Loading
Budding Design is: Enclosed Risk Category: 11 Wind Velocity: 145 mph ultimate
Mean Roof Height: ll p' Roof Pitch: 1:12
Internal Pressure Coefficient:` ±O-I8
Subjectabditg to damage from: Weathering; Negligible Termites: Very Heavy
Width of Roof End Zone: 3'-4" Wind Speed: I45 mph ultimate
Wind Exposure Classification: C pia Roo? an
Adjustment factor for Exposure Height: 1.21 x 0.4 = 0.124 ASD design
t:d PITCH
Load Combination: ASCE 1-10 Section 2A DL+LL; DL+O.LWL; 0.6DL+O.4WL
Components t Cladding Wind Pressure (NET) Roof Zone: 1. +20,4/-32.4 pot
Roof Zone: 2. +20.L/-51.0 pat
Roof Zone: 3. +20.6/-84.0 psf
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4.+35.8/-38.1 psf E�:]= Roof Zone I
Wall Zone: 5. +35.8/-41.8 pat Walls Zone 4
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3pat
Shear Walls Considered for Structure? Yes i . = Roof Zone 2
Continuous Load Path Provided? es Wells Zone 5
Are Components an Cladding Detal s Provided? Yea END ZONE
Minimum Sal Bearing Pressure:2,500 psi, Presumptive: X By Test: psi
5EE PRODUCT APPROVAL FOR IMPACT PROTECTION FOR OPENINGS W= Corner Zones
Roof Zone 3
ROOF LIVE LOAD: 31 pat ROOF DEAD LOAD: iO pat
FLOOR LIVE LOAD: J5 pat FLOOR DEAD LOAD: 10 sf
JOB ADDRESS:
Model: Date Drawn Revisions Sheet Comm #
REAR I`�-22-19
Drawn by: j '
PdRCH C.C.U. I
RIGHT Checked by:
ID. R.B- OF 5
4 N
FLOOR sea dated top
this sheet IS►-0"
Cou
q" for steel support angle
- rf-
CRASH 'POST D E T A I Recess to late Ow x 3/8"d with ncontrector verify type - 3
TYPICAL NOTES: SCALE 1/4" - I O N.T.s. 7' lY2 7Y2
1. Contractor to verify ALL notes and dimensions prior to 34" high y 4 diameter 2
steel cras post. Floor Steel countertop support angle
proceeding with work. net -
Flange wit 4 3/8 Install 9" From each end end BaxeB'amood etude E� ° ° ° ° block filled with concrete and ° ry
2. Contractor to STRICTLY enforce ALL OSHA Requirements. expansion bolts into one in center of counter. 0 D
3. ALL Lumber to be used as Beam, Rafters, etc... to have slab (3/8"t 50 ksi steel plate) see angle detail
12' x 12' Concrete column
a minimum 1,400 P.S.I. fiber stress. �' at IL" o.c. 13'-Ir' O (2) #7 bars vert. tied Into
4. No dissimilar metals to touch. vr' drywan 0 lintels above
S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete. plate p Filled cell °rider O C
ALL Concrete used for vertical filled cells, tout. tie beams etc.. to 0 2r2 z, 2° x B° PT wood D O -girder above
r2' r2
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix Attach buck to block wail with
WIRE LATH CEILING
p
6. Drywall at ceilings shall be leveled and attached to bottom chord o 1/4" dial Elco cone =raw& with min.
y g 03/8" 2'r2" 1 1/4" penetration at 12" ox. Koll7CHEN ISLAND FRAMING DETAIL 19 -9 °
of trusses with screws per FBC R102.3.5. q„ and 4" max from each corner thru
1. ALL wood in contact with concrete shall be pressure treated. 2ir2" of wall race 2" x c' PT Back O- 3' 9
S. ALL wall dimensions are nominal and not finished wall or stud dimensions. o o aril. ry MASTER
9. ALL plumbing fixtures to be low flow. i2' D BEDROOM0 CJ
10. Contractor to Provide Drain at water heater in accordance we wood .craws thru jamb into buck °U°1 0D° O ° ° °
with the current edition of the Florida Plumbing Code. at each hinge and 15' o.c. max and u E 8'-O" A.F.F.
Detail at Door prior to door attachment w D
-11. Contractor to Provide a 2'-8" wide door at one bathroom for Ts Flat Ceding
��a
handicap accessibility requirements. NuN I D
12. Lowest finished floor to be set by Governing Building Department INSTALL VULKEM BLOCK SEALANT Q I m
surveyor to set in field. �2" 2r2 2j2 ON ALL JAMB, HEADER. AND ° °
13, Separation between residence and garage shall be per FBC R302.6 /' SILL BLOCK PRIOR To BUCK I °
P 9 9 p 6 INSTALLATION N
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door vaulty to be I O
O 34 Y " high w.H. Water Heater D 2 g
Install windows thru buck Into
block with 3/I6" tap -con with 12„ \ � s. yM 8'-O° to]9'-8" A.F.F.
15. Wall and Ceilingshall have a flame -spread classification of not greater than 200 per FBC R302.9.1 1 1/2' penetration at L" o.c. max. 1 \ MASTER j Rod t Shelf - Vaulted'Ceiling
p g pp from each corner end 20." o.c. max I BATH - - - - g
I6. Wall and ceiling finishes shall have asmoke-developed index of not greater than 450 per FBC R3029.2 thereafter at .lambs and 20" ox, max. I 2" I I -
Exterior face et head end w per product approval I T` \ 31, ° 6'-4" 4" �'-3"
11. All exposed attic insulation materials installed on attic floors shall have a critical radiant °r ,�ni1 -, Back to be l" x r Pr I uy-i 1 1 I ,-► KITCHEN U
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation 1, 1-1
vane I LAY-[ I 1" li- 1
materials exposed on the underside of the roof deck or on the attic walls shall comply 1 :-'13„ 1 2„ LAUNDRY � I
with F.B.C. R316 - see permit info box of code edition 1 1 1 1 2" O °u GREAT I R O O N
18. Gyyppsum board material shall conform to ASTM C36, C19, C415, C514, C630, C931 1 1 2"1 1 J I
C960, C1002, C1041,C1171, C1118, C1278, C1395, or C1396 and shall be installed r'xq" P.T. Back nailed co I I L v-i 1 �LOS -1-
according to the following: (FBC R102.3.5) Detail at Windows pxk with cane hardened nail. ` 2" y' o I
nor to window attachment wc" Q" J 2" 2" D
Drywall
Thickness
Location
Orientation
Framing
Member
Max. spacing
of fasteners
Ned sizing options for
of drgwall into
Spacing
Maximum
installation
wood framing members
Nails
Screws
2" x min. thickness
Ceiling
Perpendicular
24"
"I"
12"
139a 1 3/8" long with 19/44" head
0.098" diameter x 1 1/4" long
i2
annular -ringed or 5d cooler nail
OR
0.080" dial x 1 5/8" long with
walls
Either
IL"
ell1L"
Direction
15/64' head
OR
G pwm board nail O.OBL" dia.
x 5/8' with 4/32" head.
Ceding
Perpendicular
24"
12"
13ga 1 5/8" long with 19/64" head
0.098" diameter x 1 3/8" Ion g
annular -ringed or Ld cooler nml
0.092" dia. 1 1/8" ion with
9
walls
Either
IL"
g^
IL"
Direction
I/4" head
OR
Gypsum board nail 0.0915" die.
x 1 1/8" with 19/44" head.
19, ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108,6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall'
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21, Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanying smoke
developed index not to exceed 450 when tested in accordance with 4STM E 84.
Insulation shall comply with-F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
24 ga, 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin cape and with 1.25" ring shank nails
spaced 6' o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
3 aNwR-i
NTS I we-1 2„ 2 H.B. -1„ toNT a
ill o H -- -� I
Rod t ShelF '- on, av 00 Ln
lu
D =
,,
a 9' S„ o LAUN RY
u�l O Ln
H v 8'-O to 9'-B" A,F.F, I O
:r- v MrJ Vaulted Ceiling
° H' DINING
0 °
V anity t be ROOM
m IS„ 42° 34 Y2 .1 h1� I I °
- T counter tops to 3/8" thick steel O
E < I I v- overhang wall 1.5"
5'- q0„ counter top supp its
eq eq noun er to
to
O L over ang wall 1.5"
O -- --
aD PANT
° O c
m _4„ m
® - - - -- U O
+41" high wall ° i DW i
SECOND I
0 o BEDROOM I KITCHEN I o
8'-0" A.F'_F.
Flat Ceding rI Vaulted Ceiling to O
O Upper cabinets to I -
extend over Ref. I I
14- MICROt AV,
D I REP. NON-V NT
12'-8„ 4„ #}" = ry 38' CLEAR
'� OPENING L - 0 - - J H-B.
O R-11 Bette Ineuletion `r (`I
O O Provide auto G
THIRD �, closer 4"e Steel Ballard O
O BEDROOM O Sea detail on thle sheet
O" wI ---
1 O 1 22" x 54,
Q O r- I =\ g Attic Access
I Q = 1 with light
8'-0" A.F.F. E+i I - - L - - - - - O
IV Flat Ceding - 8'-O" A.F.F.
12" A/C r 4 Flat Ceiiling
Simpson HETA 20 or equal i/ all#I I I a GARAGE
.
hurricane anchor at each truss 12 Masonry Beam \ 2 _gl 41 4
with (10) 10d x 1 1/2' nails PRE-ENGINEERED TRUSSES I" x L" P.T. Buck nailed to
( 24" o.c.) aup�orting Max. -4 block with case hardened nails Verify attachment O
I8
Io1ba. u ift at 24"o.c. TYPICAL I m
P prior to door attachmen hole location with GC
(shop drawings by manufacturer) i+i Block wall in O
Install SGD thru buck into prior to fabrication - ° ° 0 MT ° 0 /garage to be J
block with 3/16" tap -con with 3/8" thick L„ ° ° ° Q// struck block N
I I/2" penetration at L" o.c. max. steel bracket O R-n Bete. Inwetion Provide auto D 2'-B" O
closer
from each corner and 20." o.c. max I50 Amp 4'_4,
Aluminum Drip ---"R-30 blown fiberglass thereafter at head per product approval
EMERGENCY ° O
Edge t Fasaa m bottom chord of trusses P PPanel
3° '
1/V2' drywall with smooth finish EGRESS
° r-----------------i r------------ --� "
2" x 6" Sub-Pascia Two rows of beam block filled with concrete
Use 3/I6" tap -con with COUNTER TOP BRACKET DETAIL 3^
and (U #5 bar cost. in each row. Substitute � O D „ rn I I B
recast lintel filled with concrete and (1) 45 I I/2 penetration at 6 o.c. max. I I F I I
Kaycen full o vent vm�l soffit Installed g from each corner and. 20" o.c, max
using 1/8" dia shank x 5" long galy. gar cont. for bottom row over openings
roofing nails with 3/8" dia. head per thereafter at sill per product approval I I ° = 0 1 I
product approval -see chart sheet #1 1/2" drggwail over I" x Furring 4 O _
atria ai 14" o.c. with R, -foil GOLF CART
p ___ I" x 6" P.T. Buck nailed to _ri I I I I
insulation on typical 8" Block walla block with case hardened nails o\ I R AGE 1 1 I 0
g
All dr wall to be installed per FBC R"102.3.1 prior to door attachment I
5/8" thick fight textured �T and shall meet all ertaininP A5TM codes. Head `n O I 1 no
I I
stucco on typical concrete _ P g
block construction M Mortar to be Type "M" only proportioned per FBC RbOTI °
and Mortar Jonts shall comply with FBC R601.2.1. a Q ° ° ° ° ° - - - - - DO O 00
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...) fixed door
5 bar w/ sliding 'door ®
32 _ 1
0" overlaperlap Fill cell with concrete and ' 2'_g" q _O-� 4"1 2'-8„
at each filled cell (U U5 bar vert. (typical), n Masonry Wall _
Max spaci
ng g shall not exceed
s i � 3 O"
48" unless otherwise noted v2" a Wood see foundation plan notes for - Ai
Base spacing at openings
4" concrete slab with fibermesh OR
Bottom Track Typical Flooring Square Footage Breakdown
Cx6" #10/10 WWM on 6 and Visqueen over Sill Install SGD thru buck into Total A/C Space = 1,153 sq. ftl
clean compacted termite treated fill block with 3/14 tap -con with Covered Porch Total = 212 s , ft.
• Sliding
} I l/2" penetration at C o.c. max.
Grade S l I d I n g D oo� D � 1. a I I from eah corner and 20." o.c. max .�{i Garage = 459 sq. f t.
IIII-I111=1�11-IIII y thereafter at samba per product approvalJamlJ li Ota� �UIJIC Ft = 1�,02'� q•
At Masonr Wall NTS Under Roof Total = 2,484 s ft.
=►1 11=1 111 m I_ -I -1 I I 1=1 I I 1=1 11
11j-III1=llil=III-III-I -IIII Braden It Braden AAA, PA Wgnne Building Corp. MODEL: Date Drawn : ReYlsions : Sheet Comm tt
Architects - Planners
-IIII-IIII III with x 14" Concrete footing411 S.E. Coconut Avenue � I � � III (j�l j'1 � / � � REAR Drawn by: q
with ve e bare cost, and #5 Tel : (112) 281-8258 W I �l J.J 0� PORCH
transverse bars et 48" O.C.
T Y F' 1 C/4L SECTION Fax : (112) 281-8283
Scale : 1/2" I'-O E-mail: bradenaiaacomcast.net Spanish rakes RI HT Checked by:
Stuart FL 34996 #AAC000032 St. Lucre County Florida D.fz.B- OF 5
j
Window Schedule
Mark
Size
Rough Open.
Window Description
PRESSURE ZONE
I.
4'-Sks"x 4'-6 Ve"
54%a"x Wall
Single Hung
ZONE 4
2.
V-2ks"x V-3 %s"
15' x 63 %;'
Single Hung
ZONE 4
3.
2'-2" x 3'-2%2"
21%'x 38%"
Single Hung
ZONE 4
4.
3'-1" x V-3%"
38" x 63'A"
Single Hung
ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit info box on sheet I
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified by contractor
with manufacturer a specs prior to construction
Door Schedule
Mark
Size
Rough Opening
Door Description
PRESSURE ZONE
A
9'-0" x 1'-0"
108" x 84"
Overhead Garage Door
ZONE 4
B
3'-0" X 4'-8"
41"%4" x 83%"
Fiberglass Panel - Inswing
ZONE 4
C
6'-0" X 4'-8"
T4" x 81 %2" P Wit"°
Sliding Glass Door
ZONE 4
D
2'-0" X C-8"
Solid Core - Wood - L-Panel -Bi-Fold Finished 24" x 81'/2"
E
2'-6" X C-8"
Solid Core - Wood - 6-Panel
F
5'-0" X 6'-8"
Solid Core - Wood - 4-Panel - Bi-Fold
G
2'-8" x V-8" x 13;'
Solid Core Mood, Steel, or Maaonite Door
H
2'-8" X C-8"
Solid Core
Wood - 4-Panel
J
2'-L" X V-8"
Solid Core
Wood - L-Panel - Bi-Fold
ALL Exterior doors to withstand
box on sheet #I
GARAGE DOOR SPECIFIED IN PRODUCT
WITHSTAND THE PRESSURES STATED
All rough opening dimensions to be verified
with manufacturers specs prior to construction
pressures stated in permit info
APPROVAL FORM AND SHALL
IN PERMIT INFO BOX ON SHEET #1
by contractor
aT-1. 2" _ ( I N
C.O. 3" BATH #2 mr is m
SANITARY RISER WU 3' 4„
rite 0 - 32"
s�
w-
s
STRUCTURAL
NOTES:
I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
8.
SLOPE ALL PORCH SLABS COVERED WALK, ETC. AWAY
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
9.
DESIGN LOADS ARE AS FOLLOWS:
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
ROOF (DL+LL) = 41 PSF
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
3• POISON SOIL AND COVER W/ L MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
Ip
ALL REINFORCING STEEL SHALL BE GRADE LO, MEETING ASTM A-Ib, t
4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ it 10/10
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 30-1 STEEL.
WELDED WIRE MESH REINFORCING ON L MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
II
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FBERMESH
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
_ 5. L07 TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
12.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
FOOTING: 3"
STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND
BEAMS: 1-1/2"
COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY
PROCTOR VALUE.
13.
LAP ALL REINFORCING ST EL A MINIMUM OF 48 BAR DIAMETERS.
`• GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
14,
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1400 PSI
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
15.
ALL STANDARD LUMBER'S ALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN FINE, UNLESS NOTED OTHERWISE.
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
14.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
FOIUND/4TION FLAN
I. Any changes to plans must be submitted to the architect
SCALE: 1/4" = I'-O"
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
4. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and 1 45 bar vert, at 48"
C.C. max. Provide (1) filled cell on each side of openings Upp to 5'-II" wide.
Provide (2) filled cells on each side of openings from 6'-O" to q'-II"
1 it
and Provide (3) Pllled cells on each side of openings from 10 -O and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" o.c. unless otherwise noted (see section)
�. Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
7. Contractor to provide for soil test prior to construction and provide
a copy Of soil test t0 architect for review prior to construction
8. ALL Reinforcing steel shall be grade 40, meeting ASTM A-I6 and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar Vert. w/ Thicken edge to 8"x8"
30" overlapSEE TYPICAL n
with c n concrete
ECTIONS h o Crete and 4 o Crete slab with fibermesh OR
at each filled cell one 45 bar continuous b"xC #10/10 WWM on 10 mil Vtsqueen over
clean compacted termite treated fill
4" concrete slab with fibermesh OR GRADE
L"xV #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill _
Grade _
_ _-al�ri�llll-1111=1 m
v c — —
FOOTING
SCHEDULE
Mark
size
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
12"W
X 14"D
MONOLITHIC FOOTING
- 6" STEP DETAIL ON THIS SHEET
F'
30i'
x 30" x IL"D
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
F
8"W
x 8"D
THICKEN SLAB EDGE
WITH I #5 BAR CONTINUOUS
F5
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB m 0'-0"
Fb
12"W
X 1811D
MONOLITHIC FOOTING
- 6" STEP DETAIL ON THIS SHEET
NQT GWJ `I f! I V/0L12 x 12" concrete column block filled
I with concrete and (2) #i bars Vert. tied 7 35'-O" F into lintels above \
c 8'-I0 i," 1 1"/1 8'-I0Y," I 7
D i ---- FI ----- i
I FI I
24'=
° Io
L T
Filled cell under
r girder above
I _J Rear Porcfi Slab to O F 1
r be poured separately 1 W I
O from House Slab. O O I
ry
t t
toThicken footing to
24% x 14"d x 24"L / I under filled cell —i I O 0 ZL
under girder bearing.1901„ ° ID
FI Rear Patio/Slab to FI — — — 1
be flush with bottom of
sliding door recess.
Slope I"
EJ
II
Iff
r
-
I`
h-
0 I I 1
°
I I I
Io
4" concrete slab with fibermesh OR
I 6"xC 410/10 WWM on 4 mil Visqueen over I � '-4
clean compacted termite treated fill I a%= m
5;0n
I❑
I
I`
I I `-
F_
1
o I FI I
i
oII .
I
OW I m
I I I U
FI 4" concrete slab with fibIrrmesh OR O
6"xb" #10/10 WWM on 6 mil Visqueen over
clean compacted termite �reated fill I
O° I MICROWAVE
REF. NON —VENT
,I OPENINGR �� I O H.B.
4"0 Steel Ballard
8„ I I I See detail on this sheet I
F � PORCH SLAB EDGE DETAIL I i��# >
I I I
I I I I( I I I I= 14"w x 14' d concrete monolithic O
footing with (2) tt5 bars Cont. SCALE 1/2" = 1'-0°
14" I
aN 1 I i o
#5 bar Vert. w/ A/C
TYPICAL FOOTING DETAIL 30" overlapUl
/� at each filled cell #1 I 1 Q. I
SCALE 1/2" = I'-O" ° I
SEE TYPICAL 0
,_.,SECTIONS "�
4" concrete slab with fibermesh OR M` I FI _ I I u-'i FS
Adjust curb height on either aide of u F6 } —
4"x4" 410/10 WWM on 10 mil Visqueen over based on ar. floor house field verif L — - o I 0
q g 4" concrete slab with fibermesh OR g N r clean coin acted termite treated f111 slope. L"xL" ttl0/10 WWM on 10 mil Vis ueen 1ver service location °
p clean compacted termite treated fill r — — — — — — — — - °
45 bar Cont. #5 bar in curb P O I W I in D
O'-o" e F.F.
Grade x 4" FIT wood secured with I W F51
Q o I _ I
` 3/8"die. x 6" anchor bolt at IB" o.c. 4 Step
— — overhead door track secured to wood I O I I I11
jamb per manufacturer's product approvallilt
-1=1 —�� 1—iIII Cara e Door Jamb Detail 18 I I I F-
(2) #5 bars Cont. bottom steel = i r GARAGE DOOR TO WITHSTAND PRESSURES STATED O -' 1 3,_O, O
10" 14'w x 14"d concrete monolithic NTS
footing with (2) #5 bars Cont. IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT o ( °
121, 14„ APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL. I I I
F 2 DETAIL AT 6" GARAGE STEPDOIUN Filled Cell Masonry Column With One I F5 — — — F b ° ---------
SCALE — — — Fs- — — — J
SCALE 1/2" = 1'-0" 45 From Footing To Beam Each. Filled Cell Masonr Column With One O L — — — — — — — — O O
�j GARAGE CURB DETAIL Conc. Fill To Be 3000 PSI y ° 1.5" Recess for ° O ° a ° O O 1.5" Recess for ° O
12' x 12' concrete column SCALE 1/2" = 1'-0" See Floor Plan For Location #5 From Footing To Tie Beam ° ° Garage Door Garage oor °
block Hoed With bar concrete Conc. Fill To Be 3000 PSI
and (2) 21 bars Vert. tied
into lintels above " Verify house slab 4" concrete slab with fibermesh OR I See Floor Plan For Location 2'-8" q'-O" 2'-SI 6'-4"
height in field 6"xL" #10/10 WWM on 10 mil Visqueen over
Top of clean rooter compacted termite treated fill
IL" below finished floor +• `r > ' ' . ' '>'
IL" tt5 bar Cont.
- — Double Felled Cell COlumn Sln le Filled Cell olumn
-IIII-- II-11II- g
III=II v III- NTS NTS
301,x30"x16" concrete ""
column footingwith (4) BradenBraden idle MODEL:
OD Date Drawn Revisions
45 bars eacwag ra PI'1 PA dons
.. III
(2) tt5 bars bottom steel ' ll�l}nne �uliding Corp.
Io° Architects - Planners 4-22-19
aa' 12 411 S.E. Coconut Avenue THE �U f N D S O EI `R Drawn by:
i,
<] Tel : (��2) 281-8258 PORCH C.C.U.
COLUMN FOOTING DETAIL DETAIL AT 9 GARAGE STEPDOWN Fax : (112) 281-8283
�-- SCALE 1/2 _ 1'-0" SCALE 1/2" = 1'-0" E-mail: br�adenaiascomcast.met St. Lucie S. Lu Lakes
County Florida {�I }-�-j' Checked .
Stuart FL 3499L #AAC000032 D.R.B.
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established by the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
�Ia
MM
rV
0
F
0
Sheet Comm #
a 1 IS-I59
OF 5
f200F SHEETING
ATTACHMENT DETAIL
I. Minimum Nail Size = 8d ring shank (min. 2.5 long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" COX Plgwood
4. Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
i
TA
5 bare bar
ROOF FD L /4 �, I
I�
20
Simpson anchor
hurricane anchor at each truss
with mbeamBTie p
dameProvtersttoverlap into Provide #5 bar set m re -cast
Scale I/2 = I -O
( 24" o.c.) supporting Max
filled cell steel into continuous lintel into beam where length of
beam block steel. the opening calls for it.
— Overhangs at 1'-0" unless otherwise
noted on this sheet
1810 lbs. uplift
p
HETA 20
— Roof pitch at 4.12 unless
otherwise
noted on this sheet
Provide Cast -Crete
SUS-OB/OT
Truss shop drawings to be
provided
by manufacturer
ib., " " B1
uoc
precastlintel eat m mortar
Any changes to this plan
shall be submitted to the
BI
Min. 8" Bearing
architect for approval in
writing prior to starting construction
Strap truss to wall using Simpson MGT with
6/8' dia. threaded rod with min 12" embedment
into beam either wet set or in epoxy with
(22) IOd nails into truss. Add blocking to
truss leg per detail on this sheet
ALL TRUSS TO TRUSS CONNECTIONS BY BI
TRUSS MANUFACTURER °
Architect to review Truss Shop Drawings Prior L,oB
Provide PT Buck r,.;, to construction for layout and uplift verification
I attached per jamb i';?j Pou ed Filled Cell
rl VAY details into filled cell - Contractor to provide for Form Board Survey and to provide
4 FT 4 FT , Form Board Survey to Truss Company prior to truss 'construction o
T IL 4" Pre -cast
g a
Provide #5 bars with min. 48 bar BI I I W
4 FT 2 2 4 FT O diameters overlap in filled cell. Tie
'i filled cell steel into continuousIE
f ter 'steel.
f jh'I 1 ( 12" i
71
Ke Area Ede Field Fastener Pressure 11,1 {.I Co rate Anchors Per }I BI "
l" ,1 ( Me ufacturers Specs
Zone I (,° 6" Sd ring shank oncr
45 psi concrretoured e blocktw.I[ 7i
N
Zone 2 6" 8d ringshank l6 W u,
Zone 3 8d ring shank 84 sf G: L =
Concrete Footing a
4 4 9 p _ _ (see Tooter schedule
** Zone 3a 6" 6" 48 wood screw 112.5 per L4 x
for exact sizes)
I ry Aluminum Panel
I Seca per manufacturer = L
** Use nails or screws based on pres ure for roof stated DETAIL AT WINDOW OPENING IN _";' 12 0 m
in permit nfo box on these plans or zone 3 sTi stud ol
CBS WALL Scale: 1/2" = 1'-0" ee paicaatmsLOP 4 N °'
N
' v l/e" s 3/32' Wing Nut w/ B1 I ~ d =
i a approprmte posher and spacing 19'
SINGLE PLY ''REAR GIRDER TRUSS ` o per manufacturer's Details S N N
rmn aeu 3 .OL3'
a
i s in -I"
m .OM" U
I c � ° � O
Nail 2" x 4" blockm� to vent. leg of 1 = w a O) ° ao
truss with IOd x 1.5 nails at 4" o.c. m 3 (n E r —
Verify with Plan ;'. i a m in 4` BI u N
v- Install Simpson MGT into wall using ' a " ' " C
Concrete 6FrTI/e" dia. thre dad rod set min. 12" i _ C r
Lintel 12 x 12 into wet beam and (22) IOd nails into trues U
Column Block ; I N c L22 BI
i I .lens• w
concrete black well ' . Stud Detail W ` b V'AU ED IA:REtm
Poured Concrete or INT6Stud w/ ie Ceet Zmc Nickel Plated .Wmg NutConcrete Reber Maufacturers cSpecser v X Z
48 Bar Dia. ° to `l UJ
Reber TRUSS BLOCKING DETAIL UJ
�— UJ
Mina Overlap e = 00 W —
AT GIRDER STRAPPING Flush Mounted Shutter Detall CT) to N 0 E B 45 •:'
AT CENTER BEARING POINT nos
Column to Lintel 4ttachmlent
s
NTS
I
1/8" thick light textured stucco installed per
ASTM C 92. over ASTM D -type 2 paper backed
l� I I SCHEDULE wire lath Waded to substrate through one layer of
ASTM D Tyype 2 felt paper using 8d Wade. Substrate
/� M
to be I9/32' CDX Plywood nailed at 6" o.c. in field
and edges with IOd ring shank nails into studs.
Martr-o
Size and Description
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #11451.12
rows of beam block filled with concrete and I #5 bar 26 ga. Sv crimp metal roofing attached to plywood deck using #q x L5"
BIinuous in each row. Hook vert. bar over top bar with wood screws with selF sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 Ib felt underlagment installed with min. 4' side laps and 6" end
90° bend bar with a 10" min. lap at top bar. tape fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. et all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Additional Precast Lintel
#5 bars
Lintel
Bar
Clear
"A"
"B"
Length
Length
Span
Bars
Bars
el CLEAR
2'-10"
2'-8'r
I'-6"
2,43
none
3'-6"
3'-4"
2'-2"
2,43
none
8F8-OBAT $11" /IT BF8-IB/2T
Additional
4'-0"
3'-10"
1 2'-8"
2A3
none
#5 bar$
CLEAR ; r
4'-b"
4 '-4"
3'-2"
2.43
none
ne Row of "H ,Y
Block Above . ','.-
5'-4"
5'-2"
4'-0"
2,43
none
.,.
Pretest Lintel
5'-10"
5'-8"
4'-6"
2,44
none
r t ,1,
Additional (
6'-6"
6'-4"
5'-4"
2,#4
none
`----" #5 ban �----'
T-6"
1'-0"
6'-2"
2,45
none
BFIL-IBAT 8FI6-IB/2T
NOTES:
1'-0"
2,45
none
1, inn, coverage of steel=1.5"
2. min. bearing required a ea. end=s"
ALL reinforcing steel is grade 40.
3. standard for reinf, steel-A5TM A615
TYPICAL LINTEL SECTION
PRECAST CONCRETE )
`(
LINTEL SCHEDULE
Mark
Window
or Door
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"H" Block
Above
Bottom
Steel
S1ie
Top
Steel
8'"
Max.
Gravity
Load
(PLF)
Max.
Uplift
Load
(PLF)
Max.
Lateral
Load
(PLF)
1.22
2'-2"
3'-V
8F8-OBAT
1
45
3069
1669
1024
L31
2' 2'-6"
-8"
4'-0'
BFS-OBAT
1
#5
2561
1363
163
L45
4'-6"
5'-10'
SF8-OBAT
1
#5
1 1105
909
339
L50
5'-0"
L'-V
BFB-OBAT
1
#5
1 1238
835
121
L40
6'-8"
T-6"
8F8-05/IT
1
#5
1011
121
534
L80
8'-O"
9'-4'
BPS-IB/2T
1
#5
2
#5
152
591
512
L90
T-O"
10'-6"
8F8-IB/2T
1
45
2
us
643
630
1 401
L908
T-O"
lci
8FI6-I5/2T
ONE
1
#5
2
#5
1533
1183
1 401
WOO
10'-O"
ii'-4°
8F8-IB/2T
1
45
2
#5
582
494
452
LIOOS
10'-0"
II'-4"
BFI6-I5/2T
ONE
1
#5
2
#5
1366
1028
452
LI20
12'-0'
13'-4'
8F8-IS/2T
1
#5
1 2
1 #6
1 411
428
324
1.12015
12'-0"
13'-4"
BFIL-I15/2T
ONE
1
#5
2
1 #5
1 1015
110
324
L140
14'-0"
15'-4"
BFI6-115/2T
ONE
1
#5
2
1 al
I 125o
609
259
LI60
IL'-O'
IT-4"
8138-I5/2T
1
#5
2
#5
300
1 192
194
LI608
I6'-0"
IT-4"
81"1
ONE
1
#5
2
1
1 also
600
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Aluminum Drip
Edge t Fascle
Flash and Counter
flash Brace Gable and
Ned ledger to with 2" x 4" SYP 42
9 8ft back nailed to bottom
gable end truss of top chords using (2) IOd
with (2) IOd is nails at each truss
at each web
104 WINE
wi': WA A
it
---wood screws-afl . i-self sealria wasIx
Il. 1111 WA AN AA
laps fastened with corrosion resistant tiin
an
___%aced 4" o.c, at all laps and two, stagger
�iaps
ed . row�
12
Simpson HETA 20 or equal 4
hurricane anchor each truss
PRE-ENGINEERED WOOD TRUSSES
1 1
with (10) IOd x I I/2" Weds i'
® 24"o.c. TYPICAL
L31 BI
-
ty
24" o.c.) suppporting Max. / ,i
( shop drawings by manufacturer )
18IOIba. uplift
/
�Z3 Attic Access I BI
Q
I wth tight
1F'-1
R-30
blown fiberglass
Aluminum Drip ----0 %�
Edge f Fascia
1/2" thick stucco on 3/8" hi-rrb lath
to horizontal
in bottom chord of trusses
2°
attached and vertical wood
framing with nails or staples to provide
11
I/2" drywall with smooth finish N
2" x 6" Sub -Faso
no lees than 1-3/4" penetration into
framing
I O
I
horizontal wood and 3/4" penetration
into vertical wood framing members
Two rows of beam block filled with concrete
and (U 45 bar cost. in each row. Substitute
ni 1 op
I L31
I 1 12
Kaycan full o vent vinyl sorrit installed
recast lintel filled concrete an led with td (1) #5
ar cont. for bottom row lLl
I
I
1 I
\
unngg 1/8" dia shank x LV long gaiv.
over openings
8'-0" M
I 1. SLOPE 4
roofln nails with 3/8 die. d er
product approval - sus charts sheet 41
S/8" thick light textured
1/2" drywall over I" x Furrin
Vfod
strips at 14" o.c, with R4.1
TDD
12" x 12" concrete column
stucco on typical concrete
block
Insulation on typical 8n Block walls
SPACE I
I
I I
block filled with concrete
construction
Varies
_
All drywall to be installed per FBC R102.3.1
and (2) #1 bars vert. tied
- see Ian
P
and shall meet all pertaining ASTM codes.
into lintels above
#5 bar vent. w/
Mortar to be Type "M" on Ty proportioned er FBC R601.1
�601.2.L
30" overla p
and Mortar joints shall comply with FBC
B)
thicken edge to 8"x8"
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
L22 BI
BI L22
with concrete and
at each filled cell
one 45 bar continuous
BEYOND
Fill cell with concrete and
Rear Patio/Slab to
(I) #5 bar vert. (t ical).
9P
N O
be flush with bottom of
Max. spacing shall not exceed
sliding door recess.
Wood
48" un esa otfierwlse noted
N HE A 0
Top of Tooter
Base
see foundation plan notes for
7
1
BI tf B1
BI
IL" below finished floor
spacing at openings
Ste p per foundation plan
4" concrete slab with fibermesh OR
L90 L40
q0
6"x6" #10/10 WWM on 6 and Visqueen over
=a
Slope per foundation plan r
clean compacted termite treated fill
ry
a
.
HETA 20
HETA 20
—I I I I=III 11 II II=-1111 I I � I i_II 1=
li Provde for gutterSimpson HETA '20
=EEE EH _ 1=! II ICI 11 Provide downspout hurricane htrussI—I11 2oc) suppor ing Max
—1810 lbs. uphfI
=1,—
TCal Section at Front florch
Scale : 1/2" = 1'-0i'
Braden t Braden AIA, PA lU nCorp.ne Building CorMODEL: Date Drawn Revisions
Architects — Planners —� 4-22-19
411 S.E. Coconut Avenue REAR Drawn by:
Tel : (112) 281-8258 T �1 W i `t +—/ S `/ RORCH C.C.U.
Fax : (112) 281-8283
E—mail: bradenaiascomcast.net Spanish Lakes RI HT Checked by:
Stuart FL 34996 UAAC000032 St. Lucie County Florida ®� g
I
O
I
r
Provide downspout
Sheet Comm U
w4_ 1S—iS9
OF 5