HomeMy WebLinkAboutPRODAPP 18-0627.01 HR 7710 A HR LMIM IAM I�DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) ll 805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.Eov/economy PGT Industries, Inc. 1070 Technology Drive North Venice, FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. - DESCRIPTION: Series "HR7710A" Aluminum Horizontal Roller Window —L.M.I. APPROVAL DOCUMENT: Drawing No. 7710NOA-1, titled "Aluminum Horiz. Roller Install (LM)", sheets 1 through 19 of 19, dated 06/30/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, modeUseries, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 18-0627.01 Expiration Date: August 23, 2023 Approval Date: August 23, 2018 Page 1 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. 7710NOA4, titled "Aluminum Horiz. Roller Install (LM), sheets 1 through 19 of 19, dated 06/30/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 along with marked -up drawings and installation diagram of an aluminum horizontal sliding window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL484891, dated 06/06/18, signed and sealed by Idalmis Ortega, P.E. 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.241, and TAS 202-94 along with marked -up drawings and installation diagram of an aluminum horizontal sliding window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL484891.01, dated 07/03/18, signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6tn Edition (2017), dated 06/18/18 and updated on 07/25/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). Manuel B"er�z, P.E. Product Contr 1 E aminer NOA N-0627.01 Expiration Date Approval Date E-1 , August 232023 August 23, 2018 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 174114.14 issued to Kuraray America, Inc. "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated expiring on 07/08/19a 2. Notice of Acceptance "SentryGlas® (Clear 07/04/230 F. STATEMENTS for their O1/18/181 No. 17-0808.02 issued to Kuraray America, Inc. for their and White) Glass Interlayers" dated 12/28/17, expiring on 1. Statement letter of conformance to FBC 6t'' Edition (2017), dated July 25, 2018, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated July 25, 2018, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 18-0289 issued by the Product Control Section, dated 02/20/18, signed by Manuel Perez, RE G. OTHERS 1. None. E-2 Manuel PeX`ez P.E. Product Control �xa finer NOA No. 1 - 627.01 Expiration Date: August 23, 2023 Approval Date: August 23, 2018 SERIES HR7710A IMPACT RESISTANT HORIZONTAL ROLLER WINDOW 1) THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FOR ANCHOR FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ . QUANTITIES, 23 1 ) SEE TABLES 12-14 23" O.C..c 9 9" O.C. 2) SHUTTERS ARE NOT REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. FOR INSULATED GLASS i i i i i �7 i INSTALLATIONS ABOVE 30' IN THE HVHZ, THE OUTBOARD LITE (CAP) MUST BE TEMPERED. 3) FOR MASONRY APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLYMIAMI-DADE COUNTY APPROVED MASONRY ANCHORS. MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE, ASTM C90 CONCRETE MASONRY UNITS AND CONCRETE WITH MIN. KSI PER ANCHOR TYPE. 4) ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND SECURED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER, (EOR) OR ARCHITECT OF RECORD, (AOR). 5) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENT LENGTH TO ACHIEVE REQUIRED MIN. EMBEDMENT. SILL ANCHORS MUST BE SEALED. OVERALL SEALING & FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. 6) 1/4" MAX. SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. 7) DESIGN PRESSURES: A. NEGATIVE DESIGN LOADS BASED ON STRUCTURAL &CYCLE TESTING AND GLASS PER ASTM E1300. B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE, STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E1300. C. DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN, ASD. A 76" OVERALL HEIGHT i 75" BUCK HEIGHT .• SIBLE IGHT 34-3/8 6911 FIXEDASH LIGHT VISIBLELIGHT (I B SEE WEEPHOLE 75" BUCK WIDTH NOTES THIS SHEET -� 76" OVERALL WIDTH 8) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. ANCHORS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR CORROSION RESISTANCE, 9) METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. 10) REFERENCES: TEST REPORTS FTL 18-7891 & 18-7891.01; ELCO ULTRACON NOA; ELCO CRETEFLEX NOA; NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, ANSI/AF&PA NDS &ALUMINUM DESIGN MANUAL 11) APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL. TAR] F 1 Glass Type Description (Listed from Exterior to Interior) DP Table # Anchor Table # XO / OX XOX XO / OX XOX STD HD STD STD HD STD 1 1/8"AN, .090" PVB, 1/8" AN 2 7 12 15 2 1/8" HS, .090" PVB, 1/8" HS 3 8 12 - 16 3 3/16" AN, .090" PVB, 3/16" AN 3 - 8 12 - 16 4 13/16" LIG: 1/8" AN CAP, AIRSPACE, 1/8" AN, .090" PVB, 1/8" AN 4 7 12 15 5 13/16" LIG: 1/8" TP CAP, AIRSPACE, 1/8" AN, .090" PVB, 1/8" AN 3 7 12 15 6 13/16" LIG: 3116" AN CAP, AIRSPACE, 1/8" AN, .090" PVB, 1/8" AN 3 - 9 12 16 7 13/16" LIG: 3/16" TP CAP, AIRSPACE, 1/8" AN, '090" PVB, 1/8" AN 3 - 9 12 16 8 3/16" AN, .090" SG, 3/16" AN 5 6 10 13 14 17 9 3116" HS, .090" SG, 3/16" HS 5 6 11 13 14 18 10 13/16" LIG: 1/8" AN CAP, AIRSPACE, 3/16" AN, .090" SG, 3/16" AN 5 6 10 13 14 17 11 13/16" LIG: 1/8" TP CAP, AIRSPACE, 3/16" AN, .090" SG, 3/16" AN 5 6 10 13 14 17 12 13/16" LIG: 1/8" AN CAP, AIRSPACE, 1/8" HS, .090" SG, 1/8" HS 5 6 11 13 14 18 13 13/16" LIG: 1/8" TP CAP, AIRSPACE, 1/8" HS, .090" SG, 1/8" HS 5 6 11 13 14 18 14 13/16" LIG: 3/16" AN CAP, AIRSPACE, 1/8" HS, .090" SG, 1/8" HS 5 6 11 13 14 18 15 13/16" LIG: 3/16" TP CAP, AIRSPACE, 1/8" HS, '090" SG, 1/8" HS 5 6 11 13 14 18 SG= KURARAY SENTRYGLAS® INTERLAYER BY KURARAY AMERICA, INC. PVB = KURARAY TROSIFOL® PVB INTERLAYER BY KURARAY AMERICA, INC. AN =ANNEALED HS = HEAT -STRENGTHENED TP = TEMPERED A 22-1 /2 O.C. " TYP. FLANGE XO ELEVATION (OX SIM MAX. DIMENSIONS ALLOWED SHOWN FOR ANCHOR QUANTITIES, SEE TABLES 15-18 63" OVERALL HEIGHT 62" BUCK HEIGHT SEE SHEET 17 FOR INTEGRAL FIN ANCHORAGE TYPE & SPACING DESIGN PRESSURE RATING IMPACT RATING VARIES PER GLASS TYPE, SEE TABLES 2-11 LARGE & SMALL MISSILE IMPACT RESISTANT 9" MAX. (8-1/2" MAX. BUCK) USER INSTRUCTIONS: 1) DETERMINE THE SITE SPECIFIC, WINDOW OPENING'S DESIGN PRESSURE REQUIREMENT FROM ASCE 7. 2) KNOWING YOUR GLAZING OPTION (TABLE 1), WINDOW CONFIGURATION AND SIZE, DETERMINE YOUR WINDOW'S DESIGN PRESSURE FROM TABLES 2-11. IT MUST EQUAL OR EXCEED THE DESIGN PRESSURE REQUIREMENT FOR THE WINDOW OPENING OBTAINED IN STEP 1. 3) DETERMINE THE ANCHOR QUANTITY FROM TABLES 12-18. 4) INSTALL AS PER SHEET 15 FOR FLANGE INSTALLATION, SHEET 16 FOR EQUAL LEG INSTALLATION OR SHEET 17 FOR INTEGRAL FIN INSTALLATION. NOTE: DESIGN PRESSURE RATING DETERMINATION IS THE SAME PROCESS FOR ALL FRAME TYPES (FLANGE, INTEGRAL FIN OR EQUAL LEG/BOX). WEEPHOLE NOTES: 1) 1-5/8" X .300" WITH PLASTIC BAFFLE. 2) 1 WEEPHOLE LOCATED AT 4" FROM EACH END. 3) 1 WEEPHOLE LOCATED UNDER EACH MEETING RAIL, 12" 56" / 56" SASH FIXED / VISIBLE VISIBLE LIGHT / LIGHT / a 2O.C. O.C. 34" 55-3/8" FIXED SASH VISIBLE LIGHT VISIBLE LIGHT 9" 119" BUCK WIDTH 120" OVERALL WIDTH TYP. FLANGE XOX ELEVATION MAX. DIMENSIONS ALLOWED SHOWN CODES /STANDARDS USED: •2017 FLORIDA BUILDING CODE (FBC), 6TH EDITION •ASTM E1300-09 •ANSI/AF&PA NDS-2015 FOR WOOD CONSTRUCTION •ALUMINUM DESIGN MANUAL, ADM-2015 •AISI S100-12 •AISC 360-10 SEE WEEPHOLE NOTES, THIS SHEET GENERAL NOTES..................................1 ELEVATIONS..........................................1 GLASS TYPES TABLE ...........................1 DESIGN PRESSURES",,,,,. 2-9 ANCHOR QUANTITIES ..........................10-14 INSTALLATION / ANCHOR SPECS ....... 15-17 EXTRUSION PROFILES ........................ 18 CORNER ASSEMBLY ............................ 19 PARTS LIST ..................... 4...............0......19 Y W z z O M �j naZ w it (D O o O (n ti > O c' a}Do U' CV z � O O M � � cn Z J O Ia u> W O Z 0D= ti r N CD � WU � J ¢ J UMDJQ 2 � OW SM0 O a Z O Z o _ Q rn W � J J W LL J O W Cy)�06 ® N N i) Of H aa4S O Q Z O LL j J O Z w W ~ U JZ W 2 Q C9 al}il asaa sauas a 6 a i 0 ENS No.58705 "D STATE OF 44� ONAL 01111110 A. LYNN MILLER, P.E. P.E.# 58705 TABLE 2: 1/8"AN GLASS 090" PVB 1 /8" AN GLASS 24 30 1/2" NOM. GLASS BITE EXTERIOR 74 32 GLASS TYPE 1 3/16" AN GLASS 1/8" HS GLASS cc .090" PVB .090" PVB 1/8" HS GLASSis 3/16"AN GLASS 4 30 23 30 TABLE 3: 1/2" NOM, 1/2" NOM. GLASS BITE GLASS BITE EXTERIOR 1 EXTERIOR 74 74 32 GLASS TYPE 2 32 GLASS TYPE 3 13/16" NOM. 13/16" NOM. GLASS STACK I GLASS STACK AIRSPACE 090" PVB AIRSPACE .090" PVB 1/8" TEMPERED 3/16" AN OR 1/8" AN TP GLASS' -*' LASS 1/8" AN GLASS GLASS � GLASS 31 � 74 131 � 74 -80.0 FOR GLASS TYPES 2, 3, 6 & 7 21 OR 1 B 1/2" NOM. 1A OR 1 B 1/2" NOM. GLASS BITE GLASS BITE EXT�OR � EXTERIOR 70-73 70-73 33A OR 33B 33A OR 336 GLASS TYPE 5 GLASS TYPE 6 (ANNEALED) GLASS TYPE 7 (TEMPERED) NOTES: 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL -LEG WINDOWS, SUBTRACT 1" FROM THE TIP -TO -TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE, 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. Overall Width Design Pressure (Ibs/ft2) for XO & OX Windows Glass Type: Meeting Rail: 1 Standard 22-1/8" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt. 63" Overall Hgt. 20" +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 25" +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 37" +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 49" +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 61" +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 67" +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 74" +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +65.0 -65.0 +63.3 -63.3 Overall Width Design Pressure Ibs/ft2 for XO & OX Windows Glass Types: 2, 3, 5, 6, 7 ( ) Meeting Rail: Standard 22-1/8" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt. 63" Overall Hgt. 20" +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 25" +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 37" +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 49" +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 61" +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 67" +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -79.2* 74" +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -72.2* z Y L L1 ? (n > w co AaS, O O ? �ow O ' a}oQ U CV z W O �W cQ Z O J O a� .. W O Z = W wU� o f J u�naa� Z � 5M 0 > U) oCL z Z o U � � L� W J J ED LL JO O rn cV W ® rn N N O � aa4S = U) W Q T. Q LL O CL O Z_ Z w ' U J W = a< asQaQ sauaS 0GEN8 No.58705 STATE O60 It741 ; ONAL A. LYNN MILLER, P.E. P.E.# 58705 rr_lear�Am Overall Width Design Pressure (Ibs/ft2) for XO & OX Windows Glass Type: Meeting Rail: 4 Standard 2200,1/8" Overall Hgt, 37" Overall Hgt, 49" Overall Hgt, 55" Overall Hgt, 63" Overall Hgt. 20 +65.0 -80.0 +65.0 -80'0 +65.0 -80.0 +65.0 -80,0 +65.0 =80.0 25 +65.0 -80.0 +65.0 -80.0 +65.0 00,80,0 +65.0 -80.0 +65.0 -80.0 37 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80,0 49 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 61 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -76.8 67 +65.0 =80.0 +65.0 00-80,0 +65.0 -80.0 +65.0 -80.0 +65.0 -71.3 74 +65.0 -80.0 +65.0 ,,80, 0 +65.0 -80.0 +65.0 0`077,1 +64.9 -64.9 TART F & Overall Design Pressure (I13s/ft2) for XO & OX Windows Glass Types: 8 t Width Meeting Rail: Standard darr d 22-1/8" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt. 63" Overall Hgt. 20" +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 A 10,0 25" +80.0 -110.0 +80.0 -110.0 +80.0 A10.0 +80.0 -110'0 +80.0 t.110,0 37" +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 49" +80.0 -110.0 +80.0 A 10.0 +80.0 -110.0 +80.0 t.110,0 +80.0 -110,0 61" +80.0 A 10,0 +80.0 -110,0 +80.0 A 10,0 +80.0 -110.0 +80.0-101.9* 67" +80.0 -110,0 +80.0 -110.0 +80.0 -110.0 +80.0 A 10,0 +80.0 -95.7* 74" +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 t.90, 0* *-110.0 FOR GLASS TYPES 9, 12, 1:i, 14 & 15 GLASS TYPES 8 - 15 MAY NOT BE USED WITH INTEGRAL FIN • FRAMES N(�TES� 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL -LEG WINDOWS, SUBTRACT 1"FROM THE TIP -TO -TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. � 13/16" NOM. j GLASS STACK AIRSPACE 090" PVB GLASS---il I_I I /8" AN GLASS 1AOR 1B 1/2"NOM, GLASS BITE EXTERIOR 70-73 33A OR 33B GLASS TYPE 4 090" SG 30 23 EXTERIOR a 3/16" AN OR HS GLASS R 3/16" AN O HS GLASlS 1 NOW GLASS BITE m 32 GLASS TYPE 8 (ANNEALED) GLASS TYPE 9 (HEAT STRENGTHENE 13/16" NOM. � � GLASS STACK AIRSPACE TP GLASS 31 1AOR 1B EXTERIOR 33 OR 33B GLASS TYPE 12 GLASS TYPE 13 -090" SG 1/8" HS GLASS 74 1/2" M. GLASS BITE ANNEALED) EMPERED), AIRSPACE AN OR TP GLASS 31 1AOR 1B EXTERIOR 33A OR 33B 13/16" NOM. GLASS STACK i.090" SG �3/16" AN GLASS E 74 1/2" NOM. GLASS BIT 70-73 GLASS TYPE 10 (ANNEALED) GLASS TYPE 11 (TEMPERED) AIRSPACE 3/16" AN OR _ TP GLASS 31 1AOR 1B EXTERIOR a 33A OR 33B 13/16" NOM. GLASS STACK 090" SG HS GLASS 74 r M. ITE 70-73 GLASS TYPE 14 (ANNEALED) GLASS TYPE 15 (TEMPERED) *-110.0 FOR GLASS TYPES 9, 12, 1:i, 14 & 15 GLASS TYPES 8 - 15 MAY NOT BE USED WITH INTEGRAL FIN • FRAMES N(�TES� 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL -LEG WINDOWS, SUBTRACT 1"FROM THE TIP -TO -TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. � 13/16" NOM. j GLASS STACK AIRSPACE 090" PVB GLASS---il I_I I /8" AN GLASS 1AOR 1B 1/2"NOM, GLASS BITE EXTERIOR 70-73 33A OR 33B GLASS TYPE 4 090" SG 30 23 EXTERIOR a 3/16" AN OR HS GLASS R 3/16" AN O HS GLASlS 1 NOW GLASS BITE m 32 GLASS TYPE 8 (ANNEALED) GLASS TYPE 9 (HEAT STRENGTHENE 13/16" NOM. � � GLASS STACK AIRSPACE TP GLASS 31 1AOR 1B EXTERIOR 33 OR 33B GLASS TYPE 12 GLASS TYPE 13 -090" SG 1/8" HS GLASS 74 1/2" M. GLASS BITE ANNEALED) EMPERED), AIRSPACE AN OR TP GLASS 31 1AOR 1B EXTERIOR 33A OR 33B 13/16" NOM. GLASS STACK i.090" SG �3/16" AN GLASS E 74 1/2" NOM. GLASS BIT 70-73 GLASS TYPE 10 (ANNEALED) GLASS TYPE 11 (TEMPERED) AIRSPACE 3/16" AN OR _ TP GLASS 31 1AOR 1B EXTERIOR a 33A OR 33B 13/16" NOM. GLASS STACK 090" SG HS GLASS 74 r M. ITE 70-73 GLASS TYPE 14 (ANNEALED) GLASS TYPE 15 (TEMPERED) W ? (n > Lot) W co a� �o o u) D LOU > O a}oQ U' ti CV z O M � LOU U)Z O COD J O du) W O Z 00= "'0") = LLI N I� 49 U J W j J umoaj ON >� U) p o Z r- Z W rn W J r- -I 00 LL J O Q O rn CID W ® rn N N � LY O (n }aays = U) w LL n O 0 Z_ Z U J W = Q Q a�}!1 'asaQ 70175 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. A. LYNN MILLER, P.E. P.E.# 58705 TABLE 6: GLASS TYPES 8 15 MAY NOT BE USED WITH INTEGRAL FIN -110.0 FOR GLASS TYPES 8-13 & 1513/16" FRAMES I GLASS NOM. GLASS SO ACK GLASS SOM. ACK GLASS STACK AIRSPACE 090" SG AIRSPACE 090" SG AIRSPACE .090" SG 3/16" AN OR HS GLASS 1 /8" AN OR 1 /8" AN OR 3/16" AN OR .090" SG 3/16" AN OR TP GLASS 3/16" AN GLASS TP GLASS 1/8" HS GLASS TP GLASS 1/8" HS GLASS 23 30 LO HS GLASS 31 74 31 74 31*GLASS 74 1/2"NOM. 1AOR 1B 1/2"NOM. 1AOR 1B 1/2"NOM. 1AOR 1B1/2"NOM. GLASS BITE GLASS BITE GLASS BITE BITE EXT�ER�IOR EXTERIOR EXTERIOR EXTERIOR 74 a 70-73 70-73 70-73 32 33A OR 33B 33 OR 33B 33A OR 33B GLASS TYPE 8 GLASS TYPE 10 (ANNEALED) GLASS TYPE 12 (ANNEALED) GLASS TYPE 14 (ANNEALED) GLASS TYPE 9 GLASS TYPE 11 (TEMPERED) GLASS TYPE 13 (TEMPERED) GLASS TYPE 15 (TEMPERED) NOTES: 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR EQUAL -LEG WINDOWS, SUBTRACT 1" FROM THE TIP-TOJIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE, 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. Overall Width Design Pressure (Ibs/ft2) for XO & OX Windows Glass Types: Meeting Rail: 8 thru 15 Heavy -Duty 22-1/8" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt. 63" Overall Hgt. 76" Overall Hgt. 20" +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 25" +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 37" +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 49" +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 61" +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 67" +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -109.8* 76" +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -105.8* z Y W Z U o w M nab o O O > O ' a}oQ U CV z L O O cc w (q Z J O J O C7 d o ^ Z ED O Z B- Fn LLf r N 79 WU (DJ J J u�aa� 9 ¢ � OW OMO > o a Z _ Z o Of W J J J O Q O F- a W ® rn N C O U) aaUS = U) W Q a � O o Z_ Z w ' U W J = Q a�lll �asaQ sauaS \CEN . 0 No. 58705 /�/ NAL.I\\\\\` A. LYNN MILLER, P.E. P.E.# 58705 TARI F 7 Overall Width Sash Configuration Sash Width) Range in 9 ) Design Pressure (lbs/ft2for XOX Windows Glass Types: Meeting Rail: 1, 4,5 Standard 21-1/8" Overall Hgt. 29" Overall Hgt. 37" Overall Hgt, 49" Overall Hgt. 55" Overall Hgt. 63" Overall Hgt. 1/4-1/2-% 12,038 - 12,052 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 1 -60.0 44 1/3-1/3-1/3 12.053 - 15.008 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 1/4-1/2-1/q 12,038 - 13,302 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 49" 1/3-1/3-1/3 13.303 - 16.675 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 1/q-1/2-1/q 12,038 - 14.333 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 53-1 /8" %3-1/3-% 14.334 - 18,050 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 12.038 - 16,302 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 61" 1/3-1/3-1/3 16,303 - 20,675 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 1/q_1/2_1/q 12,038 - 20,052 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +51.9 -51.9 76 custom 20,053-22,185 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 1/3-1/3-1/3 22,186 - 25,675 +60.0 1 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 1 -60.0 ly f/4-1/2-1/q *" - 24,082 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +58.2 -58.2 +53.9 -53.9 +48.7 48.7 92A/8" custom 24,083 - 26,185 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +57.8 -57.8 1/3-1/3-1/3 26,186 - 31.038 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 �q-1/2-1/q ** - 25.302 +60.0 -60.0 -60.0 +60.0 -60.0 +58.2 -58.2 +53.9 -53.9 +48.7 -48.7 97 custom 25.303 - 27.185 +60.0 -60.0 F60, -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +55.5 -55.5 custom 27,186 - 31,038 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +58.6 -58.6 - 28,302 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +58.2 -58.2 +53.9 -53.9 +48.7 48.7 109 custom 28,303 - 29,185 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +59.8 -59.8 +51.3 -51.3 custom 29,186 - 31,038 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +52.5 120 1/4-1/2-% ** - 31,038 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +58.2 .58.2 +53.9 -53.9 +48.7 48.7 "MIN. SASH WIDTH (FLANGE WINDOWS) = OVERALL WIDTH - 57.924 2 *' MIN. SASH WIDTH (FIN & EQUAL -LEG WINDOWS) = OVERALL WIDTH - 56.924 2 NnTFS� 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL -LEG WINDOWS, SUBTRACT 1" FROM THE TIP -TO -TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. GLASS 090" PVB - 1/8"AN lGLASS 24 30 1 n1 /2" NOM. 11 GLASS BITE EXTERIOR 74 32 GLASS TYPE 1 13/16" NOM. GLASS STACK AIRSPACE 090" PVB 1�OR 1 B 1/2" NOM. GLASS BITE EXTERIOR a 70-73 33A OR 33B GLASS TYPE 4 I GLASS STACK AIRSPACE .090" PVB 1 /8" AN GLASS GLASS 31 74 21 0R 1B � 1/2" NOM. GLASS BITE EXTERIOR a 70-73 33A OR 33B GLASS TYPE 5 ao Y LLI z ? � (n > o w O Aaa o �o m O cn i > O aloa U N z� M O d� Z O J O w Ag Wci J < umoap ~O W Q CD 5Ma > � CL Z - o W � W J J M LL JO � O `° O LO rn w ® M N N = O U) aays 2 07 LU Q O� Q LL W O Z Z ULU , U J W = Q 0 aI}il 'asap saua5 No. 58705 F SATE O1��� 00F40RIOP�1• //(Illltl! A. LYNN MILLER, P.E. P.E.# 58705 TABLE 8: 1/8" HS GLASS .090" PVB 1/8" HS GLASS 30 24 1/2" NOM. GLASS BITE EXTERIOR a 74 32 GLASS TYPE 2 3/16" AN GLASS 090" PVB 23 30 3/16" ANG LASS 1/2" NOM. GLASS BITE LO EXTERIOR a 74 32 GLASS TYPE 3 * MIN. SASH WIDTH (FLANGE WINDOWS) = OVERALL WIDTH - 58.556 2 MIN. SASH WIDTH (FIN & EQUAL -LEG WINDOWS) = OVERALL WIDTH - 57.556 2 NOTES: 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL -LEG WINDOWS, SUBTRACT 1" FROM THE TIP-TOJIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. Overall Width Sash Configuration Sash Range In c) Design Pressure (Ibs/ft2) for XOX Windows Glass Types: Meeting Rail: 2, 3 Standard 21-1/8" Overall Hgt. 29" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt. 63" Overall Hgt. 44" 1/4-1/p-1/4 12.038 - 12.052 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3-1/3-1/3 12.053 - 15.008 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 49" 1/4_%2_1/4 12.038 - 13.302 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3-1/3-1/3 13.303 - 16.675 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 53-1 /8" %4_1/2_1/a 12.038 - 14.333 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3-1/3-1/3 14.334 - - 18.050 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 61" 1/4_1/2_1/4 12.038 - 16.302 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3-1/3-1/3 16.303 - - 20.675 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/4_1/2-1/4 12.038 - 20.052 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 76" custom 20.053 - 22.185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3-1/3-1/3 22.186 - 25.675 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 4- 2- 4 ** - 24.082 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 92-1/8" custom 24.083 - 26.185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 r3�%�% 26.186 - 31.048 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/4-1/2- 4 ** - 25.302 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 97" custom 25.303 - 27.185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3_1/3_1/3 27.186 - 32.675 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/4_1/2_ �a *" - 28.302 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 109" custom 28.303 - 30.185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3-1/3-1/3 30.186 - 36.675 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 �4_�2_1/a ** - 29.463 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 113-5/8" custom 29.464 - 33.185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3-1/3-1/3 33.186 - 38.222 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/4_1/2_1/4 ** - 31.052 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 120" custom 31.053 - 33.185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 custom 33.186 - 38.222 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 w ? \O (>n > M > nay of o co O 0 > O a}oQ U' N z Of Q O M L w (!) O J 0 Z Z O J O � N W O r N J �8 U W z O a Z o elf W rn J J M ILL J < O � cD w ® N N O (n aa4S = w D Q L� d O Z _Z w J WQ isaijas 7l,Dsao _ No. 58705 ' .� ®' . SATE OF \ IONAL /JIIII10 A. LYNN MILLER, P.E. P.E.# 58705 TABLE 9: Overall Width Sash Configuration Sash Width In Range 9 (in) Design Pressure (Ibs/ft2) for XOX Windows Glass Types: Meeting Rail: 6, 7 Standard 21-1/8" Overall Hgt. 29" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt, 55" Overall Hgt. 63" Overall Hgt. " % 12-1/4 12,038 - 12.052 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 44 1/3-1/3-1/3 12,053 - 15.008 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 49" 1/4_1/2_1/4 12,038 - 13.302 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3-%-% 13.303 - 16.675 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 53-1 /8" 12,038 - 14.333 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3-1/3-1/3 14,334 - 18.050 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 61" 1/4-1/2_1/4 12,038 - 16,302 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3-1/3_1/3 16.303 - 20.675 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 12.038 - 20.052 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -72.9B 76 custom 20,053 - 22.185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3_1/3_1/3 22,186 - 25.675 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 %4_Y2_1/4 ** - 24.082 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -74.1A +65.0 -67.5B 92-1/8" custom 24,083 - 26,185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/3-1/3_1/3 26,186 - 31.048 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/4_1/2_% ** - 25,302 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -74.1A +65.0 -67.5B 97" custom 25.303 - 27,185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.9 r1/3_1/3_1/3 27.186 - 32.675 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1Y4_12-1/4 ** - 28.302 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -74.1A +65.0 -67.5B 109 custom 28.303 - 30,185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -72.0 1/3-1/3-1/3 30,186 - 36.675 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.8 1/4-1/2-Y4 ** - 29,463 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -74.1A +65.0 -67.5B 113-5/8" custom 29,464 - 33,185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -70.6 1/3-1/3-1/3 33,186 - 38,222 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -76.9 4-1/- �4 2 ** - 31,052 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -74.1A +65.0 -67.5B 120" custom 31,053 - 33.185 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.7 +65.0 -68A custom 33.186 - 38.222 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -71.3 MIN. SASH WIDTH (FLANGE WINDOWS) = OVERALL WIDTH - 58.556 2 MIN. SASH WIDTH (FIN & EQUAL -LEG WINDOWS) = OVERALL WIDTH - 57.556 2 NOTES: 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL -LEG WINDOWS, SUBTRACT 1" FROM THE TIP -TO -TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. "-80.0 FOR GLASS TYPE 7 -75.0 FOR GLASS TYPE 7 s 13/16" NOM. GLASS STACK AIRSPACE 090" PVB 3/16" AN OR TP GLASS'* 1/8" AN GLASS 1A OR 113 1/2" NOM. GLASS BITE EXTERIOR a 70-73 33A OR 33B GLASS TYPE 6 (ANNEALED; GLASS TYPE 7 (TEMPERED W ? (>n O C'MLLJ m > O nab �o o cn r oLU � O Q a}oO U' N z � O O M w (q Z J O J OEL (D cn ^ Z W O = W N CD 78 WU� of _l J una� ¢ � OW DMO > U) p a Z o W rn J J J Q O co 121� W ® cy rn N O (n aayS = W Q Q O d O Z_ Z w ' U J W = Q al}il asaO sauaS \p\\\IIIIrr/r✓i No. 58705 %® S ATE O 44/ � I'ONAL Ia� //IIIIII\\ 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. A. LYNN MILLER, P.E. P.E.# 58705 TABLE 10- Overall Width Sash Configuration Sash Range (in) Design Pressure (Ibs/ft2) for XOX Windows Glass Types: Meeting Rail: 8, 10, 11 Standard 21-1/8" Overall Hgt. 29" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt. 63" Overall Hgt. 44" 1/4-1/2_Y4 12,038 - 12.052 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 1/3-1/3-Y3 12.053 - 15.008 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 49 1/4_/2_�4 12,038 - 13,302 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 1/3-%-% 13.303 - 16.675 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 53A /8 X4_Y2_Y4 12.038 - 14.333 +80.0 -110.0 +80.0 A 10,0 +80.0 -110.0 +80.0 A 10.0 +80.0 A 10.0 +80.0 -110.0 '/3-Y3-Y3 14.334 - 18,050 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 A 10.0 +80.0 -110.0 +80.0 A 10.0 1/4_�/2_�4 12.038 - 16,302 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 61" 1/3-1/3-1/3 16.303 - 20.675 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 lV4_Y _ Y4 12.038 - 20, 052 +80.0 -110.0 +80.0 -110. 0 +80.0 -110.0 +80. 0 -110.0 +80.0 -110.0 +80.0 -99.2 76 custom 20,053-22,185 +80.0 -110,0 +80.0 -110.0 +80.0 -110.0 +80.0 A10.0 +80.0 -110.0 +80.0 -110.0 1/3-1/3-1/3 22,186 - 25,675 +80.0 -110.0 +80.0 -110.0 +80.0 A 10.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 - 24,082 +80.0 A 10.0 +80.0 -110.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -101.0 +80.0 -90.5 92-1/8" custom 24,083 - 26,185 +80.0 AMID +80.0 -110.0 +80.0 A 10.0 +80.0 -110.0 +80.0 A 10.0 +80.0 -105.2 '/3-Y3-Y3 26,186 - 31,048 +80.0 A 10,0 +80.0 A 10.0 +80.0 A10,0 +80. 0 -110. 0 +80.0 A10,0 +80.0 -102.3 1/4-�/2-�/4 ** - 25,302 +80.0 A 10.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 -101.0 +80.0 -90.5 97 custom 25,303 - 27.185 +80.0 A 10.0 +80.0 A 10,0 +80.0 -110,0 +80.0 -110,0 +80.0 -110,0 +80.0 -102.7 '/3-Y3-1/3 27.186 - 32.675 +80.0 A 10.0 +80.0 A 10.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 -98.9 Y4_ Y2_Y4 ** - 28.302 +80.0 A 10.0 +80.0 A 10.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -101.0 +80.0 -90.5 109 custom 28.303 - 30.185 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -97.3 '/3-1/3-1/3 30.186 - 36,675 +80.0 -110.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110,0 +80.0 -92.9 'Y4_Y2_Y4 ** - 29.463 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110,0 +80.0 -101.0 +80.0 -90.5 113-5/8" custom 29,464 - 33,185 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -108.5 +80.0 -94.1 '/3-Y3-1/3 33,186 - 38.222 +80.0 -110,0 +80.0 A 10.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 -92.3 %4-Y2-Y4 ** - 31,052 +80.0 -110,0 +80.0 -110.0 +80.0 A 10.0 +80.0 AMID +80.0 -101.0 +80.0 7-90,5 120 custom 31.053 - 33,185 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 A 02.9 +80.0 -91.5 custom 33,186 - 38,222 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -90.6 MIN. SASH WIDTH (FLANGE WINDOWS) = OVERALL WIDTH - 58.556 2 `* MIN. SASH WIDTH (EQUAL -LEG WINDOWS) = OVERALL WIDTH - 57.556 2 NOTES: 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR EQUAL -LEG WINDOWS, SUBTRACT 1"FROM THE TIP -TO -TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 3/16" AN GLASS 090" SG 30 3/16" AN GLASS 23 i 1/2" NOM. GLASS BITE EXTERIO)32n, 74 ASS TYPE 8 13/16" NOM. GLASS STACK AIRSPACE 090" SG 1/8"AN OR TP GLASS 3/16" AN GLASS 1AOR 1B n � vr'NOM. U GLASS BITE EXTERIOR a 70-73 33A OR 33B GLASS TYPE 10 (ANNEALED GLASS TYPE 11 (TEMPERED 'GLASS TYPES 8 - 15 MAY NOT BE USED WITH INTEGRAL FIN • FRAMES LYN z Y W ? U) O w M > nay Fes- o p O LU � O Q aTO (� N Z w W' O M W U) Z J O aU W O Z CO= _ (JJ N 0 W U o f J J unaa� ON ¢ ~ W U 5MO > U) p EL Z Z o U W O W J -I M ILL JO < O cc °° LU ® rn N cif N O (n }Gays = U) W Q Q LL p O O Z_ Z w ' U J W = Q o a�}il 'asap sauas 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. A. LYNN MILLER, P.E. P.E.# 58705 TARI F 11 Overall Width Sash Configuration Width Range (in) Design Pressure (Ibs/ft2) for XOX Windows Glass Types: Meeting Rail: 9, 12, 13, 14, 15 Standard 21-1/8" Overall Hgt. 29" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt. 63" Overall Hgt. 44" 1/4-/2 1/4 12.038 - 12.052 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 1/3-1/3-1/3 12.053 - 15.008 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 49" 7/2_1/4 12.038 - 13.302 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 1/3-1/3-1/3 13.303 - 16.675 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 53-1 /8" 1/4-1/2-1/4 12.038 - 14.333 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 A 10.0 +80.0 -110.0 1/3-1/3-1/3 14.334 - 18.050 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 A 10.0 +80.0 -110.0 61" 1/4-1/2-1/4 12.038 - 16.302 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 ,,110.0 +80.0 -110.0 +80.0 -110.0 1/3-1/3-1/3 16.303 - 20.675 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 ,,110.0 +80.0 -110.0 +80.0 -110.0 1/4-1/2-�4 12.038 - 20.052 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 76 custom 20.053 - 22.185 +80.0 -110.0 +80.0 -110.0 +80.0 ,,110.0 +80.0 A 10.0 +80.0 -110.0 +80.0 A 10.0 1/3.... 1/3_1/3 22.186 - 25.675 +80.0 -110.0 +80.0 =110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 y4-1/2-�4 ** - 24.082 +80.0 ,,110.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 A 10.0 +80.0 A06.7* 92-1/8" custom 24.083 - 26.185 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 A 10.0 +80.0 A 10.0 +80.0 -110.0 1/3-1/3-1/3 26.186 - 31.048 +80.0 -110.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 1/4-%2-1/4 ** - 25.302 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 ,,110.0 +80.0 -110.0 +80.0 -106.7* 97 custom 25.303 - 27.185 +80.0 -110.0 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 1/3-1/3-1/3 27.186 - 32.675 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 1/4-1/2-�4 ** - 28.302 +80.0 A 10.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -106.7* 109" gggg custom 28.303 - 30.185 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 ,,110.0 1/3-1/3-1/3 30.186 - 36.675 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 1/4-1/2-1/4 ** - 29.463 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -106.7* 113-5/8" custom 29.464 - 33.185 +80.0 ..110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 1/3.... 1/3_1/3 33.186 - 38.222 +80.0 -110.0 +80.0 -110.0 +80.0 110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 1/4-1/2-1/4 ** at, 31.052 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -106.7* 120 custom 31.053 - 33.185 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 -110.0 +80.0 A07.8 custom 33.186 - 38.222 +80.0 .110.0 +80.0 .110.0 +80.0 -110.0 +80.0 -110.0 +80.0 ,,110.0 +80.0 A 10.0 MIN. SASH WIDTH (FLANGE WINDOWS) = OVERALL WIDTH - 58.556 2 * MIN. SASH WIDTH (EQUAL-2 LEG WINDOWS) = OVERALL WIDTH - 57.556 NOTES' 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR EQUAL -LEG WINDOWS, SUBTRACT 1" FROM THE TIP -TO -TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. '-110.0 FOR GLASS TYPES 9, 12,13 & 15 'GLASS TYPES 8 - 15 MAY NOT BE USED WITH INTEGRAL FIN • FRAMES 090" SG 30 23 EXTERIOR a 32 AIRSPACE OR TP GLASS 31 21AOR2C1 EXTERIOR a -3/16" HS GLASS HSlGLASS 1 1/2" NOM. GLASS BITE a 74 GLASS TYPE 9 a GLASS STACK TnT 33A OR 33B GLASS TYPE 12 i 090" SG HS GLASS 74 1/2" NOM. GLASS BITE 70-73 NNEALED) GLASS TYPE 13 (TEMPERED) 13/16" NOM. GLASS STACK AIRSPACE 090" SG 3/16" AN OR TP GLASS --I0i 1 /8" HS GLASS 31 )--, I l l i l l 74 1AOR 1B 1 1/2"NOM. i GLASS BITE EXTERIOR afgggg 70-73 33A OR 33B GLASS TYPE 14 (ANNEALED; GLASS TYPE 15 (TEMPERED' O LLl z W o W 00 O) nab �o o U) LLI O Q a}oQ CV Z w O M �� U) Z J O a. (n W O Z °D x J -) r N E �8 W U @� J J uno� 'ON W Q DMO U) p a Z Z o U W W J �- J m LL JO � O rn O W ® rn N C\j# O U) aayS D = Val W Q Q 0 Dag,O O Z Z U , U W J = Q a�]�1 ��sa� sauaS e °• la. � i _ No. 58705 At WATEI a �i0NAL�\ 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. A. LYNN MILLER, P.E. P.E.# 58705 TABLE 12: Anchor Quantities for XO & OX Windows Glass Types: 1 thru 7 Meeting Rail: Standard Overall Width 22-1/8" Overall Hgt, 37" Overall Hgt. 49" Overall Hgt, 55" Overall Hgt. 63" Overall Hgt. Head & Sill E Head & Sill Head & Sill E Head & Sill E Head & Sill E 20 1+C2+1 2 1+C2+1 2 1+C2+1 31 1+C2+1 3 1+C2+1 3 25 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 31 1+C2+1 3 37 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C2+1 3 49 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C2+1 3 61 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C2+1 3 67 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C3+1 * 3 74 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C3+1 * 3 "1+C2+1 FUR GLASS I YF'tS 114 tk 5 TABLE 13: Glass Types: 8 thru 15 Anchor Quantities for XO & OX Windows Meeting Rail: Standard Overall Width 22A/8" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt. 63" Overall Hgt. Head & Sill E Head & Sill E Head & Sill E Head & Sill E Head & Sill E 20 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C2+1 3 25 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C2+1 3 37" 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C2+1 3 49" 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C3+1 3 61 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C3+1 3 1+C3+1 3 67 1+C2+1 2 2+C2+2 2 2+C2+2 3 2+C3+2 3 2+C3+2 3 74 2+C2+2 2 2+C2+2 2 2+C2+2 3 2+C3+2 3 2+C3+2 4 TARI F 14� GUIDE TO USING ANCHOR QUANTITY TABLES FOR XO/OX WINDOWS: 2+C3+2� p41 CLUSTER OF 3 2ANCHORS ANCHORS AT THE CENTERED AT THE SASH MEETING RAIL 12" MAX. O.C. Glass Types: 8 thru 15 Anchor Quantities for XO & OX Windows Meeting Rail: Heavy -Duty Overall Width 22-1/8" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt, 55" Overall Hgt, 63" Overall Hgt. 76" Overall Hgt. Head & Sill Head & Sill Head & Sill E Head & Sill Head & Sill Head & Sill E cu 20 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C2+1 3 1+C2+1 4 25 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C2+1 3 1+C2+1 4 37 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C2+1 3 1+C3+1 4 49 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C2+1 3 1+C3+1 3 1+C3+1 4 61 1+C2+1 2 1+C2+1 2 1+C2+1 3 1+C3+1 3 1+C3+1 3 1+C4+1 4 67 1+C2+1 2 2+C2+2 2 2+C2+2 3 2+C3+2 3 2+C3+2 3 2+C4+2 4 76 2+C2+2 2 2+C2+2 2 2+C3+2 3 2+C3+2 3 2+C3+2 4 2+C4+2 5 2 ANCHORS AT 4 ANCHORS THE FIXED LITE IN THE JAMB �- 9" MAX. —►{ 1 ---- �- - ---- / X O L MAX. O.C. MEETING RAIL REPEAT ANCHOR PATTERN AT SILL 2-ANCHOR CLUSTER DETAIL 4-ANCHOR CLUSTER DETAIL NnTFS 9" MAX. 3-ANCHOR CLUSTER DETAIL 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR EQUAL -LEG WINDOWS, SUBTRACT 1" FROM THE TIP -TO -TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. � � Y W Z (n w tM (D O naa F o O U) i O a}oa U` CV z U O M Z QJ O av> LU O Z LL cOp °D = r N J �� WU o J umoa(] 9¢ � oW`r 5a > CO o o o z z U W O W J J m LL O O F- 0 ® rn N N = O Q aays Q Q O z p _ , LU U = Q Q al}ilasaa saua5 �ICEfVs z ff �� _ No. 53705 _ ATE 4` P4OF210P•. AL /JIIIII\0 A. LYNN MILLER, P.E. P.E.# 58705 TAR] F lc;- Overall Width Sash Configuration Sash Width Range (in) Glass Types: 1, 4, 5 Anchor Quantities for XOX Windows Meeting Rail: Standard 21-1/8" Overall Hgt. 29" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt. 63" Overall Hgt. Head & Sill s Head &Sill Head &Sill Head &Sill r Head &Sillco Head &Sill Q 1/4-1/2-1/4 12.038 - 12,052 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 44" 1/3-1/3-1/3 12,053 - 15,008 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/4_1/2_1/4 12,038 - 13.302 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 49" 1/3_1/3-1/3 13.303 - 16.675 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/4_1/2-1/4 12,038 - 14,333 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 53-1 /8" 1/31/3-1/3 14,334 - 18,050 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/2 1/4""1/4 12,038 - 16,302 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 61" 1/3 1/3 1/3 16,303 - 20,675 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/4_1/2_1/4 12,038 - 20.052 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C2+2+C2+1 3 76" custom 20.053-22,185 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/3-1/3 1/3 22,186 - 25.675 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/4-1/2-1/4 ** - 24.082 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C2+3+C2+1 3 1+C2+3+C2+1 3 92-1/8" custom 24.083 - 26,185 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1/3 1/3-1/3 26.186 - 31,038 1+C2+1+C2+1 21 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 Y4-1/2-1/4 ** - 25,302 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C2+3+C2+1 3 1+C2+3+C2+1 3 97' custom 25.303 - 27.185 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C2+2+C2+1 3 custom 27.186 - 31,038 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1/4-1/2-1/4 ** - 28.302 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C2+3+C2+1 3 1+C2+3+C2+1 3 109 custom 28,303 - 29,185 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C2+3+C2+1 3 1+C2+3+C2+1 3 custom 29,186 - 31,038 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C2+3+C2+1 3 1+C2+3+C2+1 3 120" 1/4-1/2-1/4 "" - 31.038 1+C2+3+C2+1 2 1+C2+3+C2+1 121 1+C2+3+C2+1 121 1+C2+3+C2+1 131 1+C2+3+C2+1 3 1+C2+3+C2+1 3 12" MAX. O.C. 2-ANCHOR CLUSTER DETAIL MIN. SASH WIDTH (FLANGE WINDOWS) = OVERALL WIDTH - 57.924 2 MIN. SASH WIDTH (EQUAL -LEG WINDOWS) =OVERALL WIDTH - 56.924 2 GUIDE TO USING ANCHOR QUANTITY 1+}C2'+3+C241 113 TABLES FOR XOX WINDOWS: CLUSTER OF 2 CLUSTER OF 2 3 ANCHORS ANCHORS ANCHORS IN THE 1 ANCHOR AT CENTERED AT THE CENTERED AT THE THE SASH 3 ANCHORS AT ! ' JAMB MEETING RAIL THE FIXED LITE ! MEETING RAIL 22-1/2" MAX. O.C. 1 ANCHOR AT 9It MAX. 12" MAX. O.C. THE SASH L - - - - 9" MAX. X O X NOTES: / 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR EQUAL -LEG REPEAT ANCHOR PATTERN AT SILL WINDOWS, SUBTRACT 1" FROM THE TIP -TO -TIP DIMENSION IN THE TABLE MEETING RAIL TO DETERMINE THE WINDOW SIZE. U LLI ? (n > w Aa& Yo p � O U cV Z U)i O O M � CO Z O o cam- ILu �. W o Z LL M _ r r' N E �8 wU o f J J unnoa� ¢ � ON SM a > of U) CL Z W J J 00 LL O O F- rn ® rn N {- Cr. H O ZQ aayS D 1: a Q o z O LU _ LU :D U J Z 2 Q Q a�;il asaQ sauaS No.58705 —_ S7 TES %A*ZORIDFI ONAL . e 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. A. LYNN MILLER, P.E. P.E.# 58705 TABLE 16 Overall Width Sash Configuration Sash Width Range (in) Glass Types: 2, 3, 6, 7 Anchor Quantities for XOX Windows Meeting Rail: Standard 21-1/8" Overall Hgt. 29" Overall Hgt, 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt. 63" Overall Hgt. Head & Sill =0 Head & Sill Head &Sill @ Head &Sill � Head &Sill .0 Head &SillCU -Q a-1/2-Y 12.038 - 12,052 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 44" 1/3-�3-1/3 12.053 - 15.008 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/4-1/2-1/4 12,038 - 13,302 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 49" 1/3 1/3-1/3 13,303 - 16,675 1+C2+1+C2+1 21 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/4-1/2-% 12,038 - 14,333 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 53-1 /8" 1/3-1/3 �/3 14,334 - 18.050 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 12,038 - 16.302 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 61" 16.303 - 20,675 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/4 1/2-% 12,038 - 20,052 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C2+2+C2+1 3 76 custom 20.053 - 22.185 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/3-1/3-1/3 22,186 - 25,675 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/4-%/ % ** - 24,082 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C2+3+C2+1 3 1+C3+3+C3+1 3 92-1/8" custom 24.083 - 26.185 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1/3 1/3-1/3 26,186 - 31,048 1+C2+1+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C3+2+C3+1 3 4— 1/ a - 25.302 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C2+3+C2+1 3 1+C3+3+C3+1 3 97" custom 25,303 - 27,185 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1/3-1/3 1/3 27,186 - 32.675 1+C2+1+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1/4 1/2-1/4 - 28,302 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C2+3+C2+1 3 1+C3+3+C3+1 3 109" custom 28,303 - 30.185 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C2+3+C2+1 3 1+C3+3+C3+1 3 1/3 1/3 1/3 30,186 - 36.675 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1/4-1/2-�4 - 29,463 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2L1+C2+3+C2+1 3 1+C2+3+C2+1 3 1+C3+3+C3+1 3 113-5/8" custom 29,464 - 33.185 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 22+3+C2+1 3 1+C2+3+C2+1 3 1+C3+3+C3+1 3 1/3-1/3 1/3 33,186 - 38.222 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 22+2+C2+1 3 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1/4-1/2-1/4- 31,052 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 22+3+C2+1 3 1+C2+3+C2+1 3 1+C3+3+C3+1 3 120" custom 31,053 - 33.185 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C2+3+C2+1 3 1+C3+3+C3+1 3 custom 33,186 - 38,222 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+3+C2+1 3 1+C3+3+C3+1 3 `* MIN. SASH WIDTH (FLANGE WINDOWS) = OVERALL WIDTH - 58.556 2 " MIN. SASH WIDTH (EQUAL -LEG WINDOWS) = OVERALL WIDTH - 57,556 2 1 ANCHOR AT � THE SASH 22 1/2" MAX. O.C. --�- 9" MAX. NnTFS� 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR EQUAL -LEG WINDOWS, SUBTRACT 1" FROM THE TIP -TO -TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 12" MAX. O.C. 2-ANCHOR CLUSTER DETAIL 3-ANCHOR CLUSTER DETAIL GUIDE TO USING ANCHOR QUANTITY TABLES FOR XOX WINDOWS: 1 CLUSTER OF 2 ANCHORS CENTERED AT THE MEETING RAIL L � CLUSTER OF 2 3 ANCHORS ANCHORS IN THE 3 ANCHORS AT CENTERED AT THE IAMB THE FIXED LITE MEETING RAIL 1 ANCHOR AT 1 12" MAX. O.C. THE SASH --J �- O X r� 1 9" MAX. MEETING RAID REPEAT ANCHOR PATTERN AT SILL 0 Ll1 ? (>>n O 0 LU M > nay N ow p 0 i D O Q' a}oQ w N � O O M � cn Z Do a.� Z o _ (jf N x W U o J W 2 ¢ � O �MD r > a Z c- Z � o U LLJ rn W � m LL J O O F. N rn i ® N � z aayS O Z Q Q CY Q O 0 Z O U J Z 2 Q Q a�}il ��sa� sauaS \,\CENS��1�� i 0 No, 58705 of STATE V755 i 'CCORIDP' �®ONAL I� 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. A. LYNN MILLER, P.E. P.E.# 58705 �/_\:i��i�i O�rall Width Sash Configuration Sash Width Range (in) Glass Types: 8, 10, 11 Anchor Quantities for XOX Windows Meeting Rail: Standard 21-1/8" Overall Hgt. 29" Overall Hgt. 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt. 63" O�rall Hgt. Head &Sill � � � Head &Sill s � � Head &Sill � � � Head &Sill -Q � -� Head &Sill � � � Head &Sill � @ � 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 44" ��4'��2-�a 12.038 - 12.052 1+C2+1+C2+1 2 1+C2+1+C2+1 �/3-��s-��s 12.053 - 15.008 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 49" ��a_��2_��a 12.038 - 13.302 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 ��s-�/3-�/3 13.303 - 16.675 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 ��a-��-��a 12.038 - 14.333 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 53-1 /8" �/3-��a-�/3 14.334 - 18.050 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 ��a_��2_��a 12.038 - 16.302 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C3+2+C3+1 3 61" �/3-��s-�/3 16.303 - 20.675 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C3+1+C3+1 3 ��a-��r-��a 12.038 - 20.052 1+C2+2+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C3+3+C3+1 3 1+C3+3+C3+1 3 76" custom 20.053 - 22.185 1+C2+1+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1+C3+2+C3+1 3 ��3-��3-��3 22.186 - 25.675 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C3+1+C3+1 3 1+C3+1+C3+1 3 ��4-��2-�� ** - 24.082 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+4+C2+1 3 1+C3+4+C3+1 3 1+C3+3+C3+1 3 92-1/8" custom 24.083 - 26.185 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1+C3+2+C3+1 3 �/3-�/3-�/3 26.186 - 31.048 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1+C3+2+C3+1 3 ��a_��z_��a �* - 25.302 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+4+C2+1 3 1+C3+4+C3+1 3 1+C3+3+C3+1 3 97" custom 25.303 - 27.185 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+3+C2+1 3 1+C3+3+C3+1 3 1+C3+2+C3+1 3 ��s-��s-1�s 27.186 - 32.675 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1+C3+2+C3+1 3 ��a-�2-��a ** - 28.302 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+4+C2+1 3 1+C3+4+C3+1 3 1+C3+3+C3+1 3 109" custom 28.303 - 30.185 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C3+3+C3+1 3 1+C3+3+C3+1 3 �/3-��3-�/3 30.186 - 36.675 1+C2+2+C2+1 2 2+C2+2+C2+2 2 2+C2+3+C2+2 2 2+C3+3+C3+2 3 2+C3+3+C3+2 3 1+C3+2+C3+1 3 ��a-��2-�� ** - 29.463 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+4+C2+1 3 1+C3+4+C3+1 3 1+C3+3+C3+1 3 113-5/8" custom 29.464 - 33.185 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C3+3+C3+1 3 1+C3+3+C3+1 3 1+C3+3+C3+1 3 ��s-��s-��s 33.186 - 38.222 2+C2+2+C2+2 2 2+C2+2+C2+2 2 2+C2+3+C2+2 2 2+C3+3+C3+2 3 2+C3+3+C3+2 3 2+C3+2+C3+2 3 ��a-��2-�a *'` - 31.052 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+4+C2+1 3 1+C3+4+C3+1 3 1+C3+3+C3+1 3 120" custom 31.053 - 33.185 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C3+4+C3+1 3 1+C3+4+C3+1 3 1+C3+3+C3+1 3 custom 33.186 - 38.222 2+C2+2+C2+2 2 2+C2+3+C2+2 2 2+C2+3+C2+2 2 2+C3+3+C3+2 3 2+C3+3+C3+2 3 2+C3+3+C3+2 3 "' MIN. SASH WIDTH (FLANGE WINDOWS) = OVERALL WIDTH - 58.556 2 �' MIN. SASH WIDTH (EQUAL -LEG WINDOWS) =OVERALL WIDTH - 57.556 2 NnTFS 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR EQUAL -LEG WINDOWS, SUBTRACT 1" FROM THE TIP -TO -TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 1 ANCHOR AT THE SASH 22-1/2" MAX. O.C. 9" MAX. 12" MAX. O.C. 2-ANCHOR CLUSTER DETAIL 6" MAX. O.C. -� _- 3-ANCHOR CLUSTER DETAIL GUIDE TO USING ANCHOR QUANTITY TABLES FOR XOX WINDOWS: 1 CLUSTER OF 2 ANCHORS CENTERED AT THE MEETING RAIL 1 CLUSTER OF 2 3 ANCHORS ANCHORS IN THE 3 ANCHORS AT CENTERED AT THE JAMB THE FIXED LITE MEETING RAIL 1 ANCHOR AT� j-�- 12" MAX. O.C. THE SASH -� -h �„ � (-� � O MEETING RAIL - - 9" MAX. X REPEAT ANCHOR PATTERN AT SILL U W ? � Cn O � W M co O nab � F o o cn � � � =o � O Q a}oQ U' N z � � O O M � � L7 Z J O � � � W O Z LL � aD = v � � _ � N � !� ,fig w ♦/W�� V � � J � J UM D/(] O jV ~ Z � ¢ � C7 �M 0 � � Z rt rn a Z � � � W rn W J _! m LL � O Fa- M rn � i- � O N N �--' � � O QZ }aayS � _ � Q � C� Q o � � � z p ti � w � _ � � � U � J Z = Q Q al;il asaQ sauaS ``t���dlll'//�6/ � � .� �.'• °. _ :� Flo. 587r�5 �� � °•, • �' ®�'.,.• � ATE OF ,•'.j��: 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 0 A. LYNN MILLER, P.E. P.E.# 58705 TABLE 18 Overall Width Sash Configuration Sash Width Range (in) Glass Types: 9, 12, 13, 14, 15 Anchor Quantities for XOX Windows Meeting Rail: Standard 21-1/8" Overall Hgt, 29" Overall Hgt, 37" Overall Hgt. 49" Overall Hgt. 55" Overall Hgt, 63" Overall Hgt. Head & Sill E Head & Sill s Head &Sill Head &Sill s n Head &Sill � Head &Sill n 44" 1/4-1/-1/4 12,038 - 12.052 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/3-1/3-1/3 12.053 - 15,008 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/4-1/2-1/4 12.038 - 13,302 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 49" 1/3vow 1/3MEN 1/3 13.303 - 16,675 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 /8" 1/4-1/2-1/4 12,038 - 14.333 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 53-1 1/3-1/3-1/3 14,334 - 18.050 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1/4-1/2-1/4 12,038 - 16,302 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C2+2+C2+1 3 1+C3+2+C3+1 3 61" 1/3-1/3-1/3 16.303 - 20,675 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C3+1+C3+1 3 1/4-1/-1/4 12,038 - 20,052 1+C2+2+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C3+3+C3+1 3 1+C3+3+C3+1 3 soossoosoo 76" custom 20.053 - 22.185 1+C2+1+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1+C3+2+C3+1 3 1/3-1/3-1/3 22.186 - 25,675 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 2 1+C2+1+C2+1 3 1+C3+1+C3+1 3 1+C3+1+C3+1 3 1/4_1/2-1/4 ** - 24.082 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+4+C2+1 3 1+C3+4+C3+1 3 1+C3+4+C3+1 3 92-1/8" custom 24.083 - 26,185 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1+C3+2+C3+1 3 1/3-1/3-1/3 26.186 - 31,048 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1+C3+2+C3+1 3 NEENEEMENE %-12-1/4 ** - 25.302 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+4+C2+1 3 1+C3+4+C3+1 3 1+C3+4+C3+1 3 97" custom — 25.303 - 27,185 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+3+C2+1 3 1+C3+3+C3+1 3 1+C3+3+C3+1 3 1/3-1/3-1/3 27,186 - 32,675 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 2 1+C2+2+C2+1 3 1+C3+2+C3+1 3 1+C3+2+C3+1 3 1/4-1/2-1/4 ** - 28,302 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+4+C2+1 3 1+C3+4+C3+1 3 1+C3+4+C3+1 3 109" custom 28,303-30,185 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 3 1+C3+3+C3+1 3 1+C4+3+C4+1 3 1/3-1/3-1/3 30,186 - 36.675 1+C2+2+C2+1 2 2+C2+2+C2+2 2 2+C2+3+C2+2 2 2+C3+3+C3+2 3 2+C3+3+C3+2 3 2+C4+3+C4+2 4 y4'1/2-�4 - 29.463 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+4+C2+1 3 1+C3+4+C3+1 3 1+C4+4+C4+1 3 113-5/8" custom 29.464-33,185 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C3+3+C3+1 3 1+C3+3+C3+1 3 1+C4+3+C4+1 3 1/3-1/3-1/3 33,186 - 38,222 2+C2+2+C2+2 2 2+C2+2+C2+2 2 2+C2+3+C2+2 2 2+C3+3+C3+2 3 2+C3+3+C3+2 3 2+C4+3+C4+2 4 1/4-1� -1/4 -31.052 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+4+C2+1 3 1+C3+4+C3+1 3 1+C4+4+C4+1 3 120" custom 31.053 - 33,185 1+C2+3+C2+1 2 1+C2+3+C2+1 2 1+C2+3+C2+1 121 1+C3+4+C3+1 3 1+C3+4+C3+1 3 1+C4+4+C4+1 3 custom 33.186 - 38,222 2+C2+2+C2+2 2 2+C2+3+C2+2 2 2+C2+3+C2+2 2 2+C3+3+C3+2 3 2+C3+3+C3+2 3 2+C4+3+C4+2 4 `* MIN. SASH WIDTH (FLANGE WINDOWS) = OVERALL WIDTH - 58.556 2 * MIN. SASH WIDTH (EQUAL -LEG WINDOWS) = OVERALL WIDTH - 57.556 2 GUIDE TO USING ANCHOR QUANTITY TABLES FOR XOX WINDOWS: 1 ANCHOR AT THE SASH 22-1/2" MAX. 1 CLUSTER OF 2 ANCHORS CENTERED AT THE MEETING RAIL NOTES: - - - - - r 1) OVERALL (TIP TO TIP) DIMENSIONS SHOWN. FOR EQUAL -LEG F WINDOWS, SUBTRACT 1" FROM THE TIP -TO -TIP DIMENSION IN THE TABLE X TO DETERMINE THE WINDOW SIZE. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 12" MAX. O.C. 2-ANCHOR CLUSTER DETAIL 3-ANCHOR CLUSTER DETAIL 4-ANCHOR CLUSTER DETAIL CLUSTER OF2 3ANCHORS ANCHORS IN THE CENTERED AT THE JAMB 3 ANCHORS AT MEETING RAIL THE FIXED LITE 1 ANCHOR AT -{ 12" MAX. O.C. THE SASH -�---- -- �- O X r� 1 9" MAX. MEETING RAID REPEAT ANCHOR PATTERN AT SILL Y z z U7 OM w O nay o CD O } u) > w > O Q a}oO U' CV z W O O M LU U7 Z J O a. co W O CD W U J J UMOJQ ~ W ¢ � 'ON LD OM O O (n rn a Z Z W rn W J J m LL O rn ® N N H O ZQ aa45 � T. D Q O Q O Z O � � 2 v U � Z 2 Q Q a�}il asaO saiJas `p No, 58705 '. SATE OF TONAL 0 `\;�`� A. LYNN MILLER, P.E. P.E.# 58705 INSTALLATION OPTION 1 ANCHORED THROUGH FRAME INTO 2X WOOD FRAME OR BUCKSTRIP, SEE NOTE 2, THIS SHEET. EDGE DISTANCE SHIM INSTALLATION OPTION 2 ANCHORED THROUGH FRAME DIRECTLY INTO CONCRETE/CMU. 1/4" MAX. SHIM EMBEDMENTI r d ° EMBEDMENT EDGE d, DISTANCE � G INSTALLATION OPTION 3 ANCHORED THROUGH FRAME AND 1X BUCKSTRIP INTO CONCRETE/CMU. SEE NOTE 2, THIS SHEET. SEE TABLE 1/4" MAX. SHIM NOTE B, FOR HEAD TYPE f SASH VISIBLE LIGHT WIDTH 12 4 T r ° 1 I TYP, ANCHOR TYPE, ° EMBEDMENT AND EDGE e DISTANCE PER SUBSTRATE, SEE TABLE 19. ° 44 12" LENGTH, CENTERED 63 EXTERIOR 1 20 ABOVE SASH ° ° 16 I 14 15 OVERALL HEIGHT 3�7 VISIBLE LIGHT HEIGHT 52 TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 19 & NOTE B FOR HEAD TYPE. 0 11 13 10 40 50 19 �(l. .7 14 15 36 61LENGTH, CENTERED AT MEETING RAIL, ANCHORED WITH (4) 18 SCREWS, (P# 60). ONLY REQUIRED IF OVERALL HEIGHT IS OVER 63". 35 OVERALL WIDTH HORIZONTAL SECTION A -A (SHOWN WITH I.G. GLAZING) 51 ORIZONTAL HSECTION C-C (SHOWN WITH MONO. GLAZING) 1) USE ONLY SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLE 19. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW, EMBEDMENT 2) MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE " SHIM ° ° 19. ALL WOOD BUCKS LESS THAN 1-1/2THICK ARE TO BE d CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE EXTERIOR ° OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. ° WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X EDGE TYP. ANCHOR TYPE, AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY (� DISTANCE EMBEDMENT AND EDGE TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN DISTANCE PER SUBSTRATE, AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER INSTALLATION OPTION 2 SEE TABLE 19. OR ARCHITECT OF RECORD. ANCHORED THROUGH FRAME DIRECTLY INTO CONCRETE/CMU. 3) VISIBLE LIGHT WIDTH OR HEIGHT (ALSO REFERRED TO AS DAYLIGHT OPENING) IS MEASURED FROM BEADING TO BEADING. VERTICAL SECTION B-B TABLE 19: 17 FIXED VISIBLE LIGHT WIDTH EXTERIOR MIAMI-DADS APPROVED MULLION, FBC COMPLIANT ALUMINUM/STEEL FRAMING OR STEEL STUD. MAY BE VERTICAL OR HORIZONTAL. SEE SUBSTRATE PROPERTIES, TABLE 19. EMBEDMENT EDGE DISTANCE d \ TYP.°ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 19 & NOTE B FOR HEAD TYPE. -- 1/4" MAX. SHIM Anchor Substrate Min. Edge Distance Min. Embedment Southern Pine (SG=0.55) 9/16" 1-3/8" #12 Steel, 18-8 410 Aluminum, 6063-T5 min. 3/8" 0.063" or SS Screw A36 Steel 3/8" 0.063" Steel Stud, Gr. 33 min. 3/8" 0.045" (18 Ga) Concrete (min. 3.35 ksi) 1" 1-3/4" 1/4" 410 SS CreteFlex Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" Southern Pine (SG=0.55) 1" 1-3/8 It Concrete (min. 2.85 ksi) 1" 1-3/8" 1/4" Steel Ultracon Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" Southern Pine (SG=0.55) 1" 1-3/8" INSTALLATION OPTION 4 ANCHORED THROUGH FRAME INTO METAL TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 19. A) MIN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. B) USE ONLY FLATHEAD ANCHORS IN HEAD AND SILL. PAN/HEX/FLAT HEAD TYPE IS ALLOWABLE FOR ANCHORS IN THE JAMBS. C) "UNGROUTED CMU" VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. '.r 00 LLI z ? � (n > O �j w M nab �ow O U �- � O a}oG (� N z w 0' 0 O M �� cn z J O d u) _ W 0 _ = tjJ N CD �e W U J J UMaJG ¢ � ON GMG o > iz U) O D. z o rn J W LL JO O 0 u7 rn Q ® rn N J LL C = O z aays D = O Q O u_ O z J U J Q z a�}il asaG sauas _ No. 58705 SATE 4a� o ,®0�VALIll I 1�� ��• A. LYNN MILLER, P.E. P.E.# 58705 INSTALLATION OPTION 1 ANCHORED THROUGH FRAME INTO 2X WOOD FRAME OR BUCKSTRIP. SEE NOTE 2, THIS SHEET. INSTALLATION OPTION 2 ANCHORED THROUGH FRAME DIRECTLY INTO CONCRETE/CMU. 1/4" MAX. SHIM EMBEDMENT � I 1/4 MAX. SHIM EMBEDMENT EDGE DISTANCE d ° d TYP. ANCHOR TYPE, EMBEDMENT AND EDGE d DISTANCE PER SUBSTRATE, ° SEE TABLE 20. 3 12"LENGTH,CENTERED 20 ABOVE SASH d ° TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 20 & NOTE B FOR HEAD TYPE, VISIBLE LIGHT HEIGHT BUCK 6 HEIGHT 52 50 13 10 40 50 36 EDGE DISTANCE 19 0 6" LENGTH, CENTERED AT MEETING RAIL, ANCHORED WITH (4) 18 SCREWS, (P# 60). ONLY REQUIRED IF BUCK HEIGHT IS OVER 62. ° e a 16 11 SASH VISIBLE LIGHT WIDTH 63 EXTERIOR 7 14 15 51 INSTALLATION OPTION 3 ANCHORED THROUGH FRAME AND 1X BUCKSTRIP INTO CONCRETE/CMU. SEE NOTE 2, THIS SHEET. 1/4" MAX. SHIM EMBEDMENT 6 �T 12 ° 17 EDGE 7f35 DISTANCE BUCK WIDTH HORIZONTAL SECTION A -A (SHOWN WITH I.G. GLAZING) 50 FIXED VISIBLE LIGHT WIDTH 14 15 L: MIAMI-DADE APPROVED MULLION, FBC COMPLIANT ALUMINUM/STEEL FRAMING HORIZONTAL SECTION C-C OR STEEL STUD. MAY BE VERTICAL OR HORIZONTAL. SEE SUBSTRATE (SHOWN WITH MONO. GLAZING) PROPERTIES, TABLE 20. NOTES: 1) USE ONLY SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLE 20. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. EMBEDMENT 2) d ° ° e 20. ALL WOOD ° ° ° i CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE EXTERIOR ° d OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X EDGE TYP. ANCHOR TYPE, AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY a DISTANCE EMBEDMENT AND EDGE TRANSFER L ATOADS TO THE STRUCTURE. WOOD BUCK DESIGN DISTANCE PER SUBSTRE, AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER INSTALLATION OPTION 2 SEE TABLE 20. OR ARCHITECT OF RECORD. ANCHORED THROUGH FRAME DIRECTLY INTO CONCRETE/CMU. 3) VISIBLE LIGHT WIDTH OR HEIGHT (ALSO REFERRED TO AS DAYLIGHT OPENING) IS MEASURED FROM BEADING TO BEADING. VERTICAL SECTION B-B MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE BUCKS LESS THAN 1-1/2" THICK ARE TO BE TABLE20 P. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 20 & NOTE B FOR HEAD TYPE. Anchor Substrate Min. Edge Distance Min. Embedment Southern Pine (SG=0.55) 9/16" 1-3/8" #12 Steel, 18-8 410 Aluminum, 6063-T5 min. 3/8" 0.063" or SS Screw A36 Steel 3/8" 0,063" Steel Stud, Gr. 33 min. 3/8" 0,045" (18 Ga) Concrete (min. 3.35 ksi) 1" 1-3/4 if 1/4" 410 x Flex Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4 it Southern Pine (SG=0.55) 1" 1-3/8" Concrete (min. 2,85 ksi) 1" 1-3/8" Steel Ultracon Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" Southern Pine (SG=0.55) 1" 1-3/8" 1/4" MAX. SHIM INSTALLATION OPTION 4 ANCHORED THROUGH FRAME INTO METAL TYP. ANCHOR TYPE, EMBEDMENTAND SEDGE DISTANCE PER SUBSTRATE, SEE TABLE 20. A) MIN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. B) USE ONLY FLATHEAD ANCHORS IN HEAD AND SILL. PAN/HEX/FLAT HEAD TYPE IS ALLOWABLE FOR ANCHORS IN THE JAMBS. C) "UNGROUTED CMU" VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. a0 t11 ? 0>7 O C6 LU M > O nay O W } o O Q a}Oa U N Z LU Of O M � w (n Z J J O C7 n. c u) Z W O J = W N� �g U Q J W J ¢ J UMOJa ON ~ W c7 NMO O > U) O a Z Z o CD rn J J LL -1 � O O Q � ® o r\j a W = O Z aa4S = O � O Q O Z � Q U Z = Q OWI 'asaQ saiJas \\I11111111///! i LICENSE • 4( i _ No. 58705 �o TE ••���-: f /sjZONAt-1\� A. LYNN MILLER, P.E. P.E.# 58705 BUCK HEIGHT INSTALLATION OPTION 5 ANCHORED THROUGH FIN INTO 2X WOOD FRAME OR BUCKSTRIP. EDGE II®-- EDGE DISTANCE Ir DISTANCE TYP. ANCHOR TYPE, EMBEDMENT I� DISTANCEND EDGE SUBST ATE SEE TABL1/4" MAX SHIM E 21. I ( I INSTALLATION OPTION 5 ANCHORED THROUGH FIN INTO 2X WOOD FRAME OR BUCKSTRIP. EMBEDMENT 12"LENGTH, CENTERED ABOVE SASH _ TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTATE, SEE TABLE 21 EDGE DISTANCE 1 TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE. SEE TABLE 21. VERTICAL SECTION B-B INSTALLATION OPTION 5 ANCHORED THROUGH FIN INTO 2X WOOD FRAME OR BUCKSTRIP. SASH VISIBLE LIGHT WIDTH EXT,JE�R.,IO�R' �/ l 1 de BUCK WIDTH EDGE DISTANCE 1/4" MAX SHIM — TYP. ANCHOR TYPE, EMBEDMENT AND EDGE I DISTANCE PER SUBSTRATE, I SEE TABLE 21. HORIZONTAL SECTION A -A HORIZONTAL SECTION ray : r;•�►���. v,�� r r : � �•� �•� � �. 1) USE ONLY SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLE 21. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW, 2) VISIBLE LIGHT WIDTH OR HEIGHT (ALSO REFERRED TO AS DAYLIGHT OPENING) IS MEASURED FROM BEADING TO BEADING. 3) ANCHOR TO BE INSTALLED WITHIN 2-1/2" OF FIN CORNER, FIXED VISIBLE LIGHT WIDTH IVIIHIVII-UHUC Ht't'tCV V CU IVIU LLIVIV, rbl� COMPLIANT ALUMINUM/STEEL FRAMING OR STEEL STUD. MAY BE VERTICAL OR HORIZONTAL. SEE SUBSTRATE PROPERTIES, TABLE 21. EDGE DISTANCE I���il:3��ldil�►�� 1/4" MAX. SHIM INSTALLATION OPTION 6 ANCHORED THROUGH INTEGRAL FIN INTO MET/ C IVIDCUIVIC IV I HIVU CUUC DISTANCE PER SUBSTRATE, SEE TABLE 21. Anchor Substrate Min. Edge Max. Min. Distance O.C. Embedment 2 1/2" x .113" Box Nail Southern Pine (SG=0.55) 5/16" 5" 2-7/16" x .131" Common Nail Southern Pine (SG=0.55) 3/8" 5" 2-7/16" x .145" Roofing Nail Southern Pine (SG=0.55) 3/8" 5" 2-7/16" x .145" Roofing Nail Southern Pine (SG=0.55) 3/8" 5" 2-7/16" Southern Pine (SG=0.55) 1/2" 5" 1-3/8" #10 Steel Trusshead Screw or 0.125" Aluminum, 6063-T5 min. 5/16" 5" 0.09" #12 Steel, 18-8 or 410 SS Screw 0.050" A36 Steel 5/16" 5" 0.050" 0.045" (18 Ga) Steel Stud, Gr. 33 min. 5/16" 5" 0.045" 1) MIN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. 1) MIN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. M Iliillll//� ®�v * •LY0 IN�//� ���.`••�'�ICENSF •.�`�� i No.58705 �Q YSTTEJ%F ��\ •FZORIDP'.•' GX 'ONAL 11" `�\\ A. LYNN MILLER, P.E. P.E.# 58705 2.724" 2.560" O HEAD, FLANGE FRAME 2,724" - 3.651 " O SILL, FLANGE FRAME 2.105" 7 Oz HEAD, INTEGRAL FIN FRAME 2,724" a0SILL, INTEGRAL 3L FIN FRAME 170" -� 1.300" 2.273" T 100" �- 1.300" 062" l 1 tt SASH PULL RAIL f .0150" 1 F1 = .795" .492" z3 7/16" BEAD 045" i 1 .795" .612' 44 5/16" BEAD �-� - 2,149" 4,276" Ot2 SASH LOCK RAIL 13 SASH TOP & BOTTOM RAIL TABLE 22: MATERIAL PROPERTIES USED FOR ANCHORAGE CALCULATIONS: Material Min. FY Min. F, Steel Screw 92 ksi 120 ksi 18-8 Screw 60 ksi 95 ksi 410 Screw 90 ksi 110 ksi Elco UltraCon® 155 ksi 177 ksi 410 SS Elco CreteFlex® 127.4 ksi 189.7 ksi 6063-T5 Aluminum 16 ksi 22 ksi A36 Steel 36 ksi 58 ksi Gr. 33 Steel Stud 33 ksi 45 ksi 1 2.724" l I 2.060" 3 HEAD,EQUAL )LEG FRAME 2.724" - O SILL, EQUAL LEG FRAME STRUCTURAL POLYISO- BUTYLENE WITH DESICCANT EXT. GLASS 170" 14 HD MEETING RAIL KODISPACE 70 4SG TPS 1 /4" NOM. 3.151" 1.488" 2.786" 1 1 !I 4OJAMB, FLANGE FRAME to SILL ADAPTER 2.211" ►{ 1.1y38" 1 ' 120" t5 STD MEETING RAIL HOT -MELT BUTYL STRUCTURAL SILICONE FOAM WITH DESICCANT EXT. GLASS 3.908" S )JAMB INTEGRAL FIN FRAME 040" �- 1.513" 1 -► .808" INSTALLATION HOLE COVER 1.415" 710" 06211 is SILL TRACK 109 .360" 1.032" 045" �37 16 SCREEN ADAPTER ALUMINUM REINFORCEMENT 3/16" NOM. BUTYL & DESICCANT - FOAM EXT. GLASS INT. GLASS `-INT. GLASS 71 SUPER SPACER" NXT TM 8, .987" 2.786" )JAMB, EQUAL LEG FRAME 062"-- .723" -� .875" f �- 1s WINDLOAD ADAPTER 1.446"II �- i .518" .040" 20 ANTI -LIFT CLIP -►i .630" 797" 070" - ►-- ztA IG BEAD .464" -� 798" r 065" - j o - POLYISOBUTYLENE SEAL 5/16" NOM. ROLL -FORMED STAINLESS STEEL EXT. GLASS INT. GLASS DURASEAL° 72 SPACER eta IG SNAP BEAD DESICCANT FILL 5/16" NOM SILICONE SEAL XL EDGETM 73 SPACER INT. GLASS ao LU Z U) O w m > O nab ofo o � LO > uj > O a}op () N z w Q O M r N w U)J O Z Q J O 0 ILcn X � Z LLJ Z (O °2 =mmmmigool Tggo r%%g, Lu r N r%%g, j wU C) o J u oap ON ~ Z �_ �_ ¢ � HMO > 0O U) a Z Z o O J LL O O m O mTggo ® N N }aays Fogg U) Z < � O o O ZCO Igom momm 0� 2 ll� ui J X = Q W a!}�l asap sauas `�1111lf11// �0.......&q o go so LlCE1NSF �lP ORE. so% No• 58705 -_ You - & sj, r 42� z- 0 s ATE ROPERo � ; ®®PEAL e�\\`�� '`//111110 0 A. LYNN MILLER, P.E. P.E.# 58705 rAQI r. 01 Item # Part # Description Material 1 624038 Head, Flange Frame Alum. 6063-T6 2 624039 Head, Integral Fin Frame Alum. 6063-T6 3 624040 Head, Equal -leg Frame Alum. 6063-T6 4 624001 Jamb, Flange Frame Alum. 6063-T6 5 624017 Jamb, Integral Fin Frame Alum. 6063-T6 6 624028 Jamb, Equal -leg Frame Alum. 6063-T6 7 624035 Sill, Flange Frame Alum. 6063-T6 8 624036 Sill, Integral Fin Frame Alum. 6063-T6 9 624037 Sill, Equal -leg Frame Alum. 6063-T6 10 624034 Sill Adaptor Alum, 6063-T6 11 624043 Sash Pull Rail Alum. 6063-T6 12 624006 Sash Lock Rail Alum. 6005A-T61 13 624041 Sash Top & Bottom Rail Alum. 6063-T6 14 624027 HD Meeting Rail Alum. 6063-T6 15 624005 Std. Meeting Rail Alum. 6005A-T61 16 624047 Screen Adapter Alum. 6063-T6 17 624051 Installation Hole Cover Alum. 6063-T6 18 64125M Windload Adapter Alum. 6063-T6 19 624042 Sill Track Alum. 6063-T6 20 624015 Anti -Lift Clip Alum. 6063-T6 21A 624009 IG Bead Alum.6063-T5 21B 624011 IG Snap Bead Alum. 6063-T5 23 624026 7/16" Lami Glaz. Bead Alum. 6063-T6 24 624013 5/16" Lami Glaz. Bead Alum. 6063-T6 30 6TP247 Glazing Bead, Bulb Vinyl for #624013 & #624026 Vinyl 31 6TP248 Glazing Bead, Bulb Vinyl for #624009 & #624011 Vinyl 32 712653K Mono setting Block 3/32" X 1/4" X 1" Neoprene 33A 71715K Lami IG Setting Block 1/8" x 3/4" x 1-1/14" Neoprene 33B 624014 IG Snap Setting Block Vinyl 35 724045 Sweep Latch Cast Zinc 36 71298 Weep Hole Cover Vinyl 37 41722 Hole Plug Vinyl 38 724021 Lock Rail Cover, (LH & RH) Vinyl 39 724050 Pull Rail End Cap Vinyl 40 724048 Roller Housing & Sash Guide Vinyl 41 724052 Roller Wheels Brass 42 724054 Sash Top Rail Gasket, (LH & RH) Polyethylene 43 724055 Sash Bot Rail Gasket, (LH & RH) Polyethylene 44 724057 Frame Header Gasket, (LH & RH) Polyethylene 45 724058 Frame Sill Gasket, (LH & RH) Polyethylene 46 724063 Meeting Rail Gasket Polyethylene 50 Weatherstrip, .187" x .170", Fin Seal @ Sash 51 Weatherstrip, .187" x .270", Fin Seal @ MR 52 67070 Bulb Vinyl 60 71OX38PPAX #10 X3/8" Ph, PH SMS (Windload Adapter) Stainless Steel 61 781PQX #8 X 1" Qd. PH SMS (Frame & Sash Assembly) Stainless Steel 63 - Aluminum Screen with Fiberglass Mesh Vanes 70 - Kommerling Kodispace 4SG TIPS See Sheet 71 - Quanex Super Spacer nXT 18 for Materials 72 - Quanex Duraseal Spacer 73 - Cardinal XL Edge Spacer 74 - Dow 791, 899 or GE 7700 Backbedding Silicone ASSEMBLY DETAILS FOR X� � � INTERIOR 61 � NOTES: 1) ALL CORNERS TO USE GASKET AND/OR SEALANT. 2) SOME PARTS/OPTIONS NOT SHOWN ON DRAWING FOR CLARITY. OW11111// Of W z w co�j AGa Of m O o O Ln � o w O Q a}oQ (� N Z w U) R O O M � w (q Z 0 J O a Of U Z W = W o K9 wU J J J UMajo z � ON 9MO O Of (n p a Z Z o J J LL O Df ILL!® rn N 0 N 0� CifO W }aayS = Z I¢i O o U Z_ i.- w U O = Q 00 a}}il 177,30 sauaS No. 58705 TATE OF408,049*4 <U� j®NAL G``• r111111 A. LYNN MILLER, P.E. P.E.# 58705