Loading...
HomeMy WebLinkAboutCertificate for Design Load ComplianceIVI)Wz4rz Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Project Address: 4'— l CJ W yr 0 f i 11 P 12Z - r - / Z nrr r- C— Permit#: Occupancy Type:S�_ConstructionType: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Sixth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: --I X II _III_IV Exposure Category:_B X C _D 4. Design Wind Velocity 160 mph X ASDLRFD End Zone Width: 6 ft 5. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +19.9,-31.7 Zone 2: +19.9, -55.1 Zone 3: +19.9, -81.5 Zone 4: +34.6, -37.5 Zone S: +34.6, 46.3 Garage: +29.1, -31.9 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? —Yes X Not Applicable Explain Why Not: Aspect Ratio <4:1 9. Is A Continuous Load Path Provided? X Yes_NotApplicable Explain Why Not 10. Design Soil Bearing Pressure: 2500 pSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, toa-tbe best of my knowledge and belief, the attached plans & specifications have been designed to cEiKessplecified:7 'tf he ap licable structural ions of the building codes currently adopted and enforced by St. Lucie Calso certi that structura ments depicted on these plans provide adequate resistance to the design f i1111 Donald Nuelle P.E. 52046 Print Name Cert # & Co. Cert Auth. Nuelle Engineering �zc 2D 2� Signature, Da e, an Seal 11634 SW Rowena Street, Port St. Lucie, FL 34987 Company Name & Address Revised 12/07/2018