Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method c: r Project Name: MW-262 Builder Name: GHO HOMES Street: 2986 BENT PINE DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2410.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2125.90 ft' b. Frame - Wood, Adjacent R=11.0 284.28 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2389.0 sqft.) Insulation Area a. Under Attic (Vented) R=40.0 2389.00 ft2 6. Conditioned floor area above grade (ft') 2389 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11.Ducts R ft2 7. Windows(438.7 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 668 a. U-Factor: Dbl, U=0.62 419.88 ft2 SHGC: SHGC=0.25 b. U-Factor: Gbl, default 18.80 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: Clear, default a. Central Unit 56.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 29.5 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 8.984 ft. Area Weighted Average SHGC: 0.264 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2389.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2389.00 ft2 b. Conservation features b. N/A R= ft None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.184 Total Proposed Modified Loads: 77.14 PASS Total Baseline Loads: 80.43 1 hereby certify that the plans and specifications covered by Review of the plans and FT1AE ST1? this calculation are in compliance with the Florida Energy specifications covered by this 4V " = ; ,FOB Code. ( �� #tV- calculation indicates compliance h y i„ '1 - _ '' with the Florida Energy Code. O� PREPARED BY: __ __ Before construction is completed ___ _____ DATE: _ _- --_- _-4/2$/2020 this building will be inspected for CAfi' o O compliance with Section 553.908 I hereby certify that th' as designed, is in compliance Florida Statutes. COp with the Florida Epergy Co e. WE t¢� OWNER/AGENT: _-_f_ -__ --_ __ ram. BUILDING OFFICIAL: DATE: ---- .. - --- - - ---y/� Z�Zo DATE: --- - ---- -- - - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/28/2020 4:21 PM EnergyGaugeOO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-262 User 1 GHO HOMES ST. LUCIE COUNTY Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 2389 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 2986 BENT PINE DRIV County: St. Lucie City, Stale, Zip: FORT PIERCE, FL , 34951 CLIMATE _ / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2389 23890 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2389 23890 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet -- - -- - - -- -- 1 Slab -On -Grade Edge Insulalio Main 215.7 ft 2389 fP --- --- - ---- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Barr Solar SA Emitt Emitl Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 2672 fN 0 ft' Medium N 0.4 N 0.9 No 0 26.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2389 W N N CEILING Ceiling Type Space R-Value_ Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 2389 ft' 0.1 Wood 4/28/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below --# Ornt Tn WaILType space P __R-Value-FLJn Ft In _Area R-Value-Fraction Absor.-Grade°/,_ 1 N Exterior Concrete Block - Ext Insul Main 4.1 55 9 9 4 520.3 ft' 0 0 0.3 0 2 NE Exterior Concrete Block- Ext Insul Main 4.1 8 9 11 4 99.2 ft' 0 0 0.3 0 _ 3 E Exterior Concrete Block - Ext Insul Main 4.1 58 2 9 4 542.9 ft' 0 0 0.3 0 _ 4 S Exterior Concrete Block - Ext Insul Main 4.1 60 10 9 4 567.8 ft' 0 0 0.3 0 5 W Exterior Concrete Block - Ext Insul Main 4.1 31 10 11 4 360.8 ft' 0 0 0.3 0 6 NW Exterior Concrete Block - Ext Insul Main 4.1 3 1 11 4 34.9 ft' 0 0 0.3 0 7 - Garage Frame - Wood Main 11 25 1 11 4 284.3 ft' 0 0.25 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood Main None .39 3 8 _ 24 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.25 N 11.7 ft' 2 It 0 in 1 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.25 N 6.5 ft- 2 ft 0 in 1 ft 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.25 N 20.0 ft' 26 It 0 in 3 ft 0 in None None 4 ne 2 Metal Double (Clear) Yes 0.62 0.25 N 22.5 ft' 7 ft 0 in 1 ft 0 in None None 5 ne 2 Metal Double (Clear) Yes 0.62 0.25 N 20.0 ft' 12 ft 0 in 3 ft 0 in None None 6 e 3 Metal Double (Clear) Yes 0.62 0.25 N 7.0 ft' 2 ft 0 in 3 ft 0 in None None 7 e 3 Metal Double (Clear) Yes 0.62 0.25 N 43.3 ft' 2 ft 0 in 3 ft 0 in None None 8 e 3 Metal Double (Clear) Yes 0.62 0.25 N 31.6 ft' 6 ft 0 in 1 ft 0 in None None 9 e 3 Metal Double (Clear) Yes 0.62 0.25 N 111.6 ft' 14 ft 0 in 1 ft 0 in None None 10 s 4 Metal Double (Clear) Yes 0.62 0.25 N 9.0 ft' 2 ft 0 in 1 It 0 in None None 11- s 4 Metal Double (Clear) Yes 0.62 0.25 N 21.3 ft' 2 It 0 in 1 ft 0 in None None 12 s 4 Metal Double (Clear) Yes 0.62 0.25 N 21.7 ft' 2 ft 0 in 1 It 0 in None None 13 s 4 Metal Double (Clear) Yes 0.62 0.25 N 20.0 ft' 26 ft 0 in 3 ft 0 in None None 14 w 5 Metal Double (Clear) Yes 0.62 0.25 N 8.0 ft' 10 ft 0 in 3 ft 6 in None None 15 w 5 Metal Double (Clear) Yes 0.62 0.25 N 8.0 ft' 10 ft 0 in 6 ft 6 in None None 16 w 5 Metal Double (Clear) Yes 0.62 0.25 N 45.5 fV 5 It 0 in 3 ft 6 in None None 17 w 5 None Glazed Block No 0.6 0.57 N 18.8 ft' 2 It 0 in 4 ft 4 in None None 18 NW 6 Metal Double (Clear) Yes 0.62 0.25 N 12.3 ft' 7 ft 0 in 4 ft 6 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation -- - 1 _ 582 ft' 582 ft' 64 ft 9.3 ft 1 -- - - 4/28/2020 4:21 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 2787.2 153.01 287.76 .1685 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None _ COP:1 29.48 kBtu/hr 1 _ sys#1 COOLING SYSTEM _ __ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split _ SEER: 16 56 kBtu/hr 1680 cfm 0.7 1 sys#1 HOT WATER SYSTEM _ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None _ Main _ 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Carl # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft. J DUCTS ---Supply--- V # Location R-Value Area --Return--- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC# Heat Cool 1 Attic 6 668 ft' Attic 312 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablre an Y r[ HeatiNov ng l J Jan [X] Feb [X� Mar Venting I 1 Jan [I 1 Feb l[X Mar Ceiling Fans: rr[` J] ]f [[]] rr[` ]J tOct[��]J Apr May lXl Jun lXl Jul lXl Aug lXl Sep €Xep �.Oct lnJ Nov Dec Dec 4/28/2020 4:21 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 66 68 68 68 68 68 68 PM 68 68 68 68 68 fib 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 it, 0 ft 0.3 Main 4/28/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD 14r) '2,�o:�, ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 56.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2389 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.619 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.264 14. Heating system: Capacity 29.5 c) Area 7c. 438.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 15. Water heating system a) Electric resistance EF 0.94 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF 0 Heat recovery unit HeatRec% g) Other 10131. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11 a. 40.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complie with the Florida Building Code, Energy Conservation, through the above energy saving features which will be install d (or exceeded) in this home before final Inspection. Otherwise, a new EPL display card will be completed t on i4listallg09code compliant features. Builder Signature: Date: Ze Z D Address of New Home: 2986 BENT NE DRIVE City/FL Zip: FORT PIERCE, FL 34951 4/28/2020 4:21:32 PM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1