HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
c: r
Project Name: MW-262
Builder Name: GHO HOMES
Street: 2986 BENT PINE DRIVE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2410.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2125.90 ft'
b. Frame - Wood, Adjacent
R=11.0 284.28 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2389.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=40.0 2389.00 ft2
6. Conditioned floor area above grade (ft') 2389
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11.Ducts
R ft2
7. Windows(438.7 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 668
a. U-Factor: Dbl, U=0.62 419.88 ft2
SHGC: SHGC=0.25
b. U-Factor: Gbl, default 18.80 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: Clear, default
a. Central Unit
56.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
29.5 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 8.984 ft.
Area Weighted Average SHGC: 0.264
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2389.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2389.00 ft2
b. Conservation features
b. N/A R= ft
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.184 Total Proposed Modified Loads: 77.14
PASS
Total Baseline Loads: 80.43
1 hereby certify that the plans and specifications covered by
Review of the plans and
FT1AE ST1?
this calculation are in compliance with the Florida Energy
specifications covered by this
4V " = ; ,FOB
Code. ( ��
#tV-
calculation indicates compliance
h
y i„ '1 - _ ''
with the Florida Energy Code.
O�
PREPARED BY: __ __
Before construction is completed
___ _____
DATE: _ _- --_- _-4/2$/2020
this building will be inspected for
CAfi' o
O
compliance with Section 553.908
I hereby certify that th' as designed, is in compliance
Florida Statutes.
COp
with the Florida Epergy Co e.
WE t¢�
OWNER/AGENT: _-_f_ -__ --_ __ ram.
BUILDING OFFICIAL:
DATE: ---- .. - --- - - ---y/� Z�Zo
DATE: ---
- ---- -- - -
Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/28/2020 4:21 PM EnergyGaugeOO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-262
User
1
GHO HOMES
ST. LUCIE COUNTY
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 2389
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 2986 BENT PINE DRIV
County: St. Lucie
City, Stale, Zip: FORT PIERCE,
FL , 34951
CLIMATE
_ /
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2389 23890
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
2389 23890 Yes 4
3
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
--
- -- - - -- --
1 Slab -On -Grade Edge Insulalio Main 215.7 ft
2389 fP
--- --- -
---- 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red
Barr
Solar SA Emitt Emitl Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip
Flat tile/slate 2672 fN 0 ft' Medium
N
0.4 N 0.9 No 0 26.6
ATTIC
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 2389 W
N N
CEILING
Ceiling Type
Space R-Value_ Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 40 Blown
2389 ft' 0.1 Wood
4/28/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
--#
Ornt
Tn
WaILType
space
P
__R-Value-FLJn
Ft In
_Area
R-Value-Fraction
Absor.-Grade°/,_
1
N
Exterior
Concrete Block - Ext Insul
Main
4.1 55
9
9 4
520.3 ft'
0
0 0.3
0
2
NE
Exterior
Concrete Block- Ext Insul
Main
4.1 8
9
11 4
99.2 ft'
0
0 0.3
0
_ 3
E
Exterior
Concrete Block - Ext Insul
Main
4.1 58
2
9 4
542.9 ft'
0
0 0.3
0
_ 4
S
Exterior
Concrete Block - Ext Insul
Main
4.1 60
10
9 4
567.8 ft'
0
0 0.3
0
5
W
Exterior
Concrete Block - Ext Insul
Main
4.1 31
10
11 4
360.8 ft'
0
0 0.3
0
6
NW
Exterior
Concrete
Block - Ext Insul
Main
4.1 3
1
11 4
34.9 ft'
0
0 0.3
0
7
-
Garage
Frame - Wood
Main
11 25
1
11 4
284.3 ft'
0
0.25 0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Wood Main
None
.39
3
8
_
24 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
n
1
Metal
Double (Clear)
Yes
0.62 0.25
N
11.7 ft'
2 It 0 in
1 ft 0 in
None
None
2
n
1
Metal
Double (Clear)
Yes
0.62 0.25
N
6.5 ft-
2 ft 0 in
1 ft 0 in
None
None
3
n
1
Metal
Double (Clear)
Yes
0.62 0.25
N
20.0 ft'
26 It 0 in
3 ft 0 in
None
None
4
ne
2
Metal
Double (Clear)
Yes
0.62 0.25
N
22.5 ft'
7 ft 0 in
1 ft 0 in
None
None
5
ne
2
Metal
Double (Clear)
Yes
0.62 0.25
N
20.0 ft'
12 ft 0 in
3 ft 0 in
None
None
6
e
3
Metal
Double (Clear)
Yes
0.62 0.25
N
7.0 ft'
2 ft 0 in
3 ft 0 in
None
None
7
e
3
Metal
Double (Clear)
Yes
0.62 0.25
N
43.3 ft'
2 ft 0 in
3 ft 0 in
None
None
8
e
3
Metal
Double (Clear)
Yes
0.62 0.25
N
31.6 ft'
6 ft 0 in
1 ft 0 in
None
None
9
e
3
Metal
Double (Clear)
Yes
0.62 0.25
N
111.6 ft'
14 ft 0 in
1 ft 0 in
None
None
10
s
4
Metal
Double (Clear)
Yes
0.62 0.25
N
9.0 ft'
2 ft 0 in
1 It 0 in
None
None
11-
s
4
Metal
Double (Clear)
Yes
0.62 0.25
N
21.3 ft'
2 It 0 in
1 ft 0 in
None
None
12
s
4
Metal
Double (Clear)
Yes
0.62 0.25
N
21.7 ft'
2 ft 0 in
1 It 0 in
None
None
13
s
4
Metal
Double (Clear)
Yes
0.62 0.25
N
20.0 ft'
26 ft 0 in
3 ft 0 in
None
None
14
w
5
Metal
Double (Clear)
Yes
0.62 0.25
N
8.0 ft'
10 ft 0 in
3 ft 6 in
None
None
15
w
5
Metal
Double (Clear)
Yes
0.62 0.25
N
8.0 ft'
10 ft 0 in
6 ft 6 in
None
None
16
w
5
Metal
Double (Clear)
Yes
0.62 0.25
N
45.5 fV
5 It 0 in
3 ft 6 in
None
None
17
w
5
None
Glazed Block
No
0.6 0.57
N
18.8 ft'
2 It 0 in
4 ft 4 in
None
None
18
NW 6
Metal
Double (Clear)
Yes
0.62 0.25
N
12.3 ft'
7 ft 0 in
4 ft 6 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
-- -
1
_
582 ft'
582 ft'
64 ft
9.3 ft
1 --
- -
4/28/2020 4:21 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000445
2787.2 153.01 287.76 .1685 7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity Block
Ducts
1 Electric Strip Heat/
None
_
COP:1 29.48 kBtu/hr 1
_
sys#1
COOLING SYSTEM
_ __ # System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
_
SEER: 16 56 kBtu/hr 1680 cfm 0.7 1
sys#1
HOT WATER SYSTEM
_ # System Type SubType
Location
EF Cap Use SetPnt Conservation
1 Electric None
_
Main
_
0.94 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Carl # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft.
J
DUCTS
---Supply---
V # Location R-Value Area
--Return--- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC#
Heat Cool
1 Attic 6 668 ft'
Attic
312 ft' Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programablre an
Y r[
HeatiNov
ng l J Jan [X] Feb [X� Mar
Venting I 1 Jan [I 1 Feb l[X Mar
Ceiling Fans: rr[` J] ]f [[]] rr[` ]J tOct[��]J
Apr May lXl Jun lXl Jul lXl Aug lXl Sep €Xep �.Oct lnJ Nov
Dec
Dec
4/28/2020 4:21 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
66
68
68
68
68
68
68
PM
68
68
68
68
68
fib
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture
Fraction
Space
Default 8 Ibs/s
.ft.
0 it,
0 ft
0.3
Main
4/28/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
14r) '2,�o:�,
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
56.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2389
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.619
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.264
14. Heating system: Capacity
29.5
c) Area
7c.
438.7
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
15. Water heating system
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
0 Heat recovery unit HeatRec%
g) Other
10131. 11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11 a. 40.0
b) Cross ventilation No
11 b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complie with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be install d (or exceeded) in this home before final Inspection. Otherwise, a new EPL
display card will be completed t on i4listallg09code compliant features.
Builder Signature: Date: Ze Z D
Address of New Home: 2986 BENT NE DRIVE City/FL Zip: FORT PIERCE, FL 34951
4/28/2020 4:21:32 PM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1