HomeMy WebLinkAboutProduct approvals, FL 22378.6Florida Building Code Online BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval bp' r ��' us--- USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL22378-R6 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago, IL 60185 (800)663-3667 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A http://www.floridabui]ding.org/pr/pr_app_dtl.aspz?parmn=wGEVXQwtDgs3M6m9%2fK8XPIOX7v28WDo0MX5mi9306VsY1Xv4vXZY6A%3d%3d[2/12/2019 5:15:24 PM] Florida Building. Code Online Date Submitted 01/25/2019 Date Validated 01/28/2019 Date Pending FBC Approval Date Approved 02/04/2019 Summary of Products FL # Model, Number or Name Description 22378.1 Stormguard Fiberglass Side -Hinged 6'-8" Opaque I/S Single Door Door Unit Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-65 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 3'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FLO170 for anchor details and water performance where required. 22378.2 Stormguard Fiberglass Side -Hinged Door Unit Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 3'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FLO170 for anchor details and water performance where required. 22378.3 Stormguard Fiberglass Side -Hinged Door Unit Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50.5/-50.5 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FLO170 for anchor details and water performance where required. 22378.4 Stormguard Fiberglass Side -Hinged Door Unit Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55.0/-50.5 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FLO170 for anchor details and water performance where required. Certification Agency Certificate FL22378 R6 C CAC NI007077 07-R2 pd Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL22378 R6 II FL0170.12df Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378 R6 AE 514010A.odf Created by Independent Third Party: Yes 6'-8" Opaque O/S Single Door Certification Agency Certificate Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL22378 R6 II FL0170.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378 R6 AE 514014A.pdf Created by Independent Third Party: Yes 6'-8" Opaque I/S Single or Double Door w/ or w/o Sidelites Certification Agency Certificate FL22378 R6 C CAC NI007077.07-R2.Rdf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL22378 R6 II FL0170 odf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378 R6 AE 514008A.12df FL22378 R6 AE 514012A.odf Created by Independent Third Party: Yes 6-8" Opaque O/S Single or Double Door w/ or w/o Sidelites Certification Agency Certificate FL22378 R6 C CAC NI007077.07-R2.pdf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL22378 R6 II FL0170.odf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378 R6 AE 514008A.Ddf FL22378 R6 AE 514012A.odf Created by Independent Third Party: Yes 22378.5 Stormguard Fiberglass Side -Hinged 6'-8" Impact Glazed I/S or O/S Single Door w/ or w/o Sidelites Door Unit http://www.floridabuilding.org/pr/pr_app dti.aspx?paratn=wGEVXQwtDgs3M6yn9%2fK8XPIOX7v28WDoOMX5tni9306VsYIXv4vXZY6A%3d%.'d[2/12/20195:15:24PM1 Florida Building Code Online Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22378 R6 C CACNIO07077 nd-R3 Approved for use outside HVHZ: Yes 12d Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2020 Design Pressure: +55/-55 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL 0172 odf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 9'-0" x 6'-8" max nominal size. Hurricane Evaluation Reports protective system is NOT required. See DWG-MA-FLO172 for FL22378 R6 A 14008A odf anchor details and water performance where required. FL22378 R6 AE 514012A.pdf Created by Independent Third Party: Yes 22378.6 Stormguard Fiberglass Side -Hinged 6'-8" Impact Glazed I/S Double Door w/ or w/o Sidelites Door Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22378 R6 C CAC NI007077 nq-R3 Approved for use outside HVHZ: Yes QSf Quality Assurance Contract Expiration Date Impact Resistant: Yes Design Pressure: 12/31/2020 +50/-55 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL 0172 ILdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane Evaluation Reports protective system is NOT required. See DWG-MA-FLO172 for FL22378 R6 AE 514008A.pdf anchor details and water performance where required. FL22378 R6 AE 514012A pdf Created by Independent Third Party: Yes 22378.7 Stormguard Fiberglass Side -Hinged 6'-8" Impact Glazed O/S Double Door w/ or w/o Sidelites Door Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes EL22378 R6 C CACNI007077 0 -R3 Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date �pu,.ar Impact Resistant: Yes 12/31/2020 Design Pressure: +55/ 55 Installation Instructions . * ` Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL 0172.I2df Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane Evaluation Reports protective system is NOT required. See DWG-MA-FLO172 for FL22378 R6 AE 514008A.)Zdf anchor details and water performance where required. FL22378 R6 AE 514012A4df Created by Independent Third Party: Yes 22378.8 Stormguard Fiberglass Side -Hinged 8'-0" Opaque I/S Single Door Door Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22378 R6 C CAC NI007077.08 pd 1 Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2020 Design Pressure: +60/-65 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL0171.12df Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 3'-0" x 8'-0" max nominal size. Hurricane Evaluation Reports } protective system is NOT required. See DWG-MA-FLO171 for FL22378 R6 AE 514009A.pdf anchor details and water performance where required. FL22378 R6 AE 514013A.Ddf Created by Independent Third Party: Yes 22378.9 Stormguard Fiberglass Side -Hinged 8'-0" Opaque O/S Single Door Door Unit y1 Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22378 R6 C CAC NI007077.08 oddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2020 Design Pressure: +60/ 60 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL0171.pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 3' 0" x 8' 0" max nominal size. Hurricane Evaluation Reports protective system is NOT required. See DWG-MA-FLO171 for FL22378 R6 AE 514009A.12df anchor details and water performance where required. FL22378 R6 AE 514013A.Ddf Created by Independent Third Party: Yes f 4 E rz 0^" 22378.10 Stormguard Fiberglass Side -Hinged 8'-0" Opaque I/S Single or Double Door w/ or w/o Sidelites htip:,iwww.tloridabuilding.org/pr/pr_app_dtl.asps?paratn=wGEVXQwtDgs3M6m9%2tK8XPIOX7%28WDo0MX5mi9306VsYIXv4vXZY6A%3d%3dl2/12/20195:15:24 PMI 92L09 2 2gd aJ IS f Od d SWOa 996! Q 1 (AEI/&3NSVPV A§ k§ Oe Li R¥ F- c§ m= V) }} � §CC cc (Dul §� \R \ am 7vd-wz ■ ozmA« JXWW WN _2 SWLW -v 92109 �[ '09V0/H0 IS3M SNWVXI 9NWHOW OV08 simod 996t �Iswjssv —NOIN Im ww 3vfw WHOO 7VNOUVNdg.LM 3MOSYN am ZYWW.9-.9 15 —no 6 IT gc L uj 03ovds kiivnO3 380A Ir 6 _ SNO�Sin3a. sirv�a V � _ b 92109 T `09b01H3 IS3M SNOI1VJ07 9NiHONJNV SMS ... $31VOdn OSIW 'ON o 3 N Od06 SIMOd 996 l iew3ssv a0 1NVd sMs 31'd0dn aOHONV stez's ao0a 3�araa sMs _ S3bodn SnOlatn ( i sz 4 0 dl�00 ldNQllb'Nt131N1311NQ5bW .°i�naorea'aoaB xag sL� til a3aav M 1 _.�SZ �b its Ci e ..... O � .9 _" P -- -- 030VdS xiivn03 38OW 4—'------ _t N O N W i �i 0 W J q oN az S W Um H go O Z� J= W V Y Z 'o p p q of W m 0�Z W O J H O<Z �0U W O. �OpN 4. I You) X Y(wQ d- so �U U p _ Op W i—pox z mZ om ZO N�q �Ik� -1xJ 0 0 �r7 QS � UxJ oz ~_ ¢g6 oa C7W S 3x m o Z a o !z z \� m _J :2:D O � 'ndx� N = O�V I O z O� µ rr r ' UJ. J q { Y Z U � D p •° U Q Z �0 z O� Q q y.:. :2 Z U Q U � O Z 'Q N N� W q .(D O Lil wN� p J U F \ w U v) q 3 Y W N o W U U � ZZ2~ d o wq�ON�Y w •-• ZaN¢a����~ OViw _W�Oc=n¢ a "z �Qz(4 ZOI-wp}O pM O �wnp wwuj O 03. W-,p0U0Z zWoo N�gog Es cn 'Wj r< U-1 0_of1==-=Qd m�Q D'Mr--00��Ha N_ O p O L w 13 0,-p J _� 0 w M Z Op q >F/i Z W N�_ � W q co 04 q- cn U3z p ZgZ�.�zppJOZ� t- Q g O p O U J U W Z OOpZU=O��InU Li ��}O z S V ZO {_ 0 W 22 p q Z�tJigwm af o_ZOL q gv�....Wmi-�aa3p LJ U q O � �V) z� W a U O �w cn Z w m J W w �V) Z L'i 0 Fm U F O U Z_ W � U p H 0 M z E W O > = W Z Q �z N UI V �Z r ® aZ W X{ ® 0Q �pU __.0— W J v 0— o= dz OOU ® X v� W J z D H Z W W O W W_ w= � =v q maw O O :D ¢� w z tr J w O >MQ z J ~ � wi w z t- oa d C,Z" W W w cnZ) LLJ UJ 01 O O w O � wqLLJ �� p Z p U Z p a N w o 46 �:_ 2� W fn z H Q O O F N m d W J a u) O ,n cr a p � Ld O O = U Z q W W O m = r- V) :D w �U cr Cf) W V) W = J O� > m � z q Y OJ W ?� a in � mO OMi O q _Z K n S1fV130 V tie g8l 09 �I `OOH0lH0 1S�M SNUI*07 ON?10HONY_ sans GV08 SIMOd 996l iewassv ao laud sMs WHOO IVN011VNE131NI 311NOSVPV o3ma ssv�sauMn 80sMs .38U �aN .a-.s -I)fKmd dom yawla clue LO U 111 ti _ �\1 V Z 7 m o m i F Z i Q U I za 6'8 w �N ZG uS m �W Q m < 2 2W o � o 0 L. Roberto Lomas P. E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville. NC 27023 Report #: 514008A 434-688-0ii09 Date: 10/10/2017 rljoinas-¢�IrlOmaspe. com Test Report: N/A Product: Double Door with and without sidelites 12'x6'8" (wood frame) Scone: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code. Anchor capacity in shear condition: Solid members w/ 6 w/out gap: a. With threads present in shear plane Fastener type: #10 wood screw (NOS 2012, NOS 2015, TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: P. 1,140 in Screw bending yield strength: F,„ = 80,000 psi Side member. Douglas Fir -Larch (6=0.50) Main member: Spruce -Pine -Fir (G=0.42) Side member thickness: t, = 1.000 in Main member thickness: tm = 1.500 in Side member dowel bearing strength: Fes. = 4,650 psi Main member dowel bearing strength: Fir, = 3,350 psi Side member dowel bearing length: I, = 1.000 in Main member dowel bearing length: Im = 1.140 in Mode I, Mode I, Mode II Mode III,, Mode III, Mode IV qm= 636.5lbs/in qs= 884lbs/in A: 00007 A: 000096 A: 0,00107 A: 0.00135 P = 725.61 Ibs P = 884 Ibs R: 1.07 8: 0,57 8: 0.5 8: 0.000 Ko = 2,400 Ko = 2.400 C:-427,674 C: -253.623 C: -267.699 C: -93.6 Z„= 302 Ibs Z.= 368 lips P = 331 Ibs Ms = 46.8 in-Ibs Mm = 46.8 in-Ibs Ko = 2,400 P = 297 Ibs P = 319 Ibs P = 263 Ibs Min. Design value: Z= 110 Ibs Z= 138 lips Ko = 2.400 Ka = 2.400 Ko = 2 400 Duration Factor: Co = 1.6 Z= 124 Ibs Z= 133 Ibs Z= 110 Ibs Fastener type: 1/4 ITW Topton N.O.A. 16-1222.06 Substrate: Hollow block Minimum embedment: 1,25 in Actual edge distance: 2.50 in Actual C To C spacing: 3,00 in Allowable Design Value: Z..= 155 Ibs/anchor (per Tabulated values edge distance spocirg (in) 2.00 4.00 2.00 130 161 4.00 163 202 when needed) Substrate: 18 GA, Steel Tabulated design value: Z= 1266 Ibs Safety factor: Fs= 4 Allowable Design Value (ZFs): Z'= 316 Ibs/anchor Minimum anchor capacity: 155 Ibs/anchor Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. Anchor calculations, minimum required anchors 36.38 36.38 Design pressure: 60.0 psf it---� Al Al �Az 79.25 Al Al G � 72.75 37.50 36.38 36.38 37.50 Al A4 A4 Al A2Y Y Y YA2 Al A4 A4 Al 147.75 1 of 4 79.25 Zone Area 2 (ft) Load (Ibs) Ind (in) Max. O.C. (in) Anchor Result Cap. (Ibs) Qty Load (Ibs) A, 2.3 138 N/A N/A 155 1 138 OK AZ 7.7 463 6.00 21.00 155 5 93 OK A3 7.7 463 N/A N/A 155 1 3 154 OK Design pressure: 60.0 psf Zone Area z (ft) Load (Ibs) Ind. (in) Max. O.C. (in) Anchor Result Cap. (Ibs) Q Load (Ibs) A, 2.4 146 N/A N/A 155 1 146 OK A2 7.9 473 6,00 21.00 155 5 95 OK A, 7.8 468 N/A N/A 155 4 117 OK AQ 2.3 1 138 N/A N/A 155 1 138 OK A5 7.7 463 N/A N/A 155 3 1 154 1 OK \�� 5 RL 0 IV _*• 951 •,t_ �7D TATV07 • ONAL`ti����� Luis R. Lomas P.E. FL No.: 62514 10/10/2017 L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville. NC 27023 Manufacturer: Masonite Report # 514008A 434-688-0609 Date: 10/10/2017 rl;oinas,�lrlomasoe con^ Anchor Locations: Double door 79.25 6.00 TYP. 36.38 6.00 TYR 36.38 18.19 TYR -� ti 3.00 TYP.',---, 1 i I 6.00 18" MAX O.C. i 6.00 Luis R. Lomas P.E. FL No.: 62514 2 of 4 10/10/2017 L. Roberto Lomas P. E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville. NC 27023 Report #514008A 434-668-0609 012masna Irlarasoe cons Date: 10/10/2017 Double door with sidelites 37.50 - ------- 36.38 - -- 36,38 37.50 ------- 18.75 TYP. 6.00 TYP. - 6.00 TYP. 18.1 9 TYP. 3.00 TYP. w. I, 6.00 16" MAX O.C. I 79.25 6.00 1T \5� R •' jL 0 /��ii •: 0 F 0/0NAt`E?G`�` Luis R. Lomas P.E. FL No.: 62514 3 of 4 10/10/2017 L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville, NC 27023 434-688-0609 Manufacturer: Masonite Report* 514008A Date: 10/1012017 rliomas�Irlomaspe com Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 114" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM, D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI 052" THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. T WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 9 WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL, 10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. of 4 R L 0 �;• •\,fir' E N `q qCP 51 �y eO F :c� 0 R IOP • ��'�: ONA�tE?G`�\ Luis R. Lomas P.E. FL No.: 62514 10/10/2017 L. Roberto Lomas P. E. 1432 W00090fd Rd, Lewisville. NC 27023 Manufacturer: Masonite Report #: 514012A 434-688-0609 Date: 10/1012017 rl Iorna s(d)l ripmaspe. coo Test Report: N/A Product: Double Door with and without sidelites 12'x6'8" (composite frame) Scope: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code. Anchor capacity in shear condition: Solid members w/ d w/out gap: a. With threads present in shear plane Fastener type #10 wood screw (ND5 2012, N05 2015, TR12) Nominal diameter: D: 0.190 in faP: g: 00000 in Pact diameter Dr: 0.152 in Moment arm: 00000 Minimum required penetration. p: 1.140 in Screw bending yield strength: n Fyb = 80,000 psi Side member. PVC Main member: Spruce -Pine -Fir (6=0.42) Side member thickness: t, = 1.000 in Main member thickness tm = L500 in Side member dowel bearing strength: F., = 10,000 psi Main member dowel bearing strength: F- = 3,350 psi Side member dowel bearing length: I, = 1.000 in Main member dowel bearing length: Im = 1.140 in Mode I,r, Mode I: Mode II Mode III,r, Mode III, Mode IV qm = 636.5 Ibs/in qs = 1900 Ibs/in A: 0.0005 A: 000066 A: 0.00092 A: 0.00105 P = 725.61 Ibs P = 1900 Ibs B: 1.07 B: 0.57 B: 0.5 B: 0.000 Ko = 2.400 K❑ = 2,400 C:-681799 C:-253.623 C: -521.824 C: -93.6 Z.= 302 Ibs Z,= 792 Ibs P = 510 Ibs Ms = 46.8 in-Ibs Mm = 46.8 in-Ibs Ko = 2.400 P = 324 Ibs P = 529 Ibs P = 299 lips Min. Design value: Z= 125 Ibs Z= 212 Ibs K❑ = 2.400 Ko = 2.400 Ko = 2.400 Duration Factor: Co z 1.6 Z= 135 Ibs Z= 221 Ibs Z= 125 Ibs Allowable Design Value (ZCo): Z'= 199 Ibs/anchor Fastener type: 1/4 ITW Topton Tabulated values N.O.A. 16-1222.06 edge spacing (in) Substrate: Hollow block distance 2.00 1 4.00 Minimum embedment: 1.25 in 2.00 130 161 Actual edge distance: 2.50 in 4.00 163 202 Actual C To C spacing: 3.00 in Allowable Design Value: 2l.= 155 Ibs/anchor (per interpolation when needed) Fastener type: #10 Self tapping screw (Calculations per 2015 Aluminum Design Manual, section J.5.5) Nominal screw diameter: D: 0.190 in Screw root area: Ar 0.0151 in' Actual edge distance'. de: 1.085 in Screw shear ultimate strength: Fn 54.0 ksi Per table J3.2 of 2010 Steel Construction Manual 14th Edition Side member material: Vinyl PVC Main member material: 6063-T5 aluminum Thickness: t, 1.000 in Thickness: tz 0.052 in Ultimate tensile strength: F,, 14 ksi Ultimate tensile strength: F12 22 ksi Nominal strength per bearing (side member): On = 2Dt,F,,, Rnl = 5320 Ibs (Eq J.542) Nominal strength per bearing (main member): On = 2Dt,Fwz Rn2 = 435 Ibs (Eq 15.12) Nominal strength per tilting: On = 4.2(tz30)"'F,,z On = 478 Ibs (Eq J.5-13) Nominal screw shear strength: On = ArFnA 25 On = 654 Ibs (Eq J.5-14) Safety factor: 0= 3 Allowable shear and bearing capacity: P_ 145 Ibs/anchor Fastener type: #10 Self topping screw (Calculations per AISI-5100-12, sections A2.3.2 and E4.3.1) Nominal screw diameter: D: 0.190 in Screw shear ultimate strength: Fn 54.0 ksi Screw root area: Ar 0.0151 in' Per table J3.2 of 2010 Steel Construction Manual 14th Edition Side member material: Vinyl PVC Main member material: Metal framing Thickness: t, 1.000 in Thickness: t2 O("^ '- Ultimate tensile strength: F,,, 14 ksi Ultimate tensile strength: F„z Nominal strength per tilting: On = 4.2(tz30)1z2F„z On = 1001 Ibs (Eq E4.3.2-1) S R . Nominal strength per bearing (side member): On = 2.7Dt,F=1 Rnl = 7182 Ibs (Eq E4.3.1-2 and -4) ���_`� : • ' 0'�J�/�j Nominal strength per bearing main member); On = 2.7Dt F� Rn2 = 1280 Ibs V • 7 9 P 9( ) z z (Eq E4.3.1-3 and -5) y• �G E Nominal screw shear strength: On = A,F,,,/1.25 On = 654 Ibs • F •• ,_ Safety factor: 0 - 3 * • 0 f�51 Allowable shear and bearing capacity: Pe 218 Ibs/anchor • y Y�l -'� Minimum anchor capacity: 145 Ibs/anchor 0 F �. Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. • 0 R lOP GZ�: /SYONAL,E?���� 1 of 4 Luis R. Lomas P.E. FL No.: 62514 10/ 10/2017 L. Roberto Lomas P. E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville, NC 27023 Report #: 514012A 434-688-0609 Date: 10/10/2017 rl lomasnl rlorna spe. corn Anchor calculations, minimum required anchors 36.38 36.38 Design pressure: 60.0 psf Al Al Aa 79.25 Al Al _ 1 J 72.75 37.50 36.38 36.38 37.50 Al A4 A4 Al A2 Y_ Y Y,]2 - 79.25 Al A4 A4 Al I_ y 147.75 Zone Area 2 (ft) Load (Ibs) Ind. (in) Max. O.C. (in) Anchor Result Cap. (Ibs) QtY Load (Ibs) A. 2.3 138 N/A N/A 145 1 138 OK Az 7.7 463 6.00 21.00 145 5 93 OK A3 7.7 463 N/A N/A 145 4 116 OK Design pressure: 60.0 psf Zone Area 2 (ft) Load (Ibs) Ind. (in) Max. O.C. (in) Anchor Result Cap. (Ibs) Q� Load (Ibs) A. 2.4 146 N/A N/A 145 2 73 OK AZ 7.9 473 6.00 21.00 145 5 95 OK A 7.8 468 N/A N/A 145 4 117 OK A4 2.3 138 N/A N/A 145 1 138 OK A 7.7 463 N/A N/A 145 1 4 1 116 OK Anchor Locations: Double door 36.38 - - 36.38 5.00 TYP. 6.00 �-P P-18.19 TYP. 3.0. 6.00 18' MAX O.C. 79.25 - 6.00 2 of 4 ,R I f CIO, �.' •��c E N `sF'9`P -5i *• �51 • yt OF 0 RtOP • �'�'�� e/ONAt1E"G��\ Luis R. Lomas P.E. FL No.: 62514 10/10/2017 L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville, NC 27023 Manufacturer: Masonite Report* 514012A 434-688-0609 Date: 10/10/2017 rliomast�lrlomaspe. com Double door with sidelites 6.00 TYP. __ 37.50 18 75 TYP. 6.00 TYR j3.00 TYR ______ __ 36.38 ___-_ 18.19 7YP. ._ . 36.38 37.50 6.00 T- 18" MAX O.C. 3.25 6.00 3 of 4 5\1F,1 �t 1t 0 //�// -v .��0 E No qcP • r p , TAT 0 F , zz ' OR VO s/ONA'L:\ Luis R. Lomas P.E. FL No.: 62514 10/10/2017 L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville. NC 27023 434-688-0609 Manufacturer: Masonite Report #: 514012A Date: 10110/2017 rllomasrrJlflomaspe com Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/21, MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN BELOW. 2 FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW, 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW 4_ ALL FASTENERS TO BE CORROSION RESISTANT 5 INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0A2 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM D. METAL STRUCTURE: STEEL 18GA (048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI 052" THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN 7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL 9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12 BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 4 of 4 Luis R. Lomas P.E. FL No.: 62514 10/10/2017