Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method hxF. St IMM Project Name: Lot 7 Block 5 Port St Lucie 1512 AGL Builder Name: ADAMS HOME=CountV, , Street: 5325 San Bendetto Place Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florid 1. New construction or existing New (From Plans) 9. Wall Types (1641.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1347.00 ft2 b. Frame - Wood, Adjacent R=13.0 294.94 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst rase? No 10. Ceiling Types (1512.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1512.00 ft2 6. Conditioned Floor area above grade (ft2) 1512 b. N/A R= ft2 Conditioned Floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(174.2 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 302.4 a. U-Factor: Dbl, U=0.33 118.38 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 35.00 ft2 12. Cooling systems kStu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 3.00 ft2 a. Electric Heat Pump 28.2 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 3.801 ft. Area Weighted Average SHGC: 0.276 14. Hot water systems 8. Floor Types (1512.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor' Area: 0.115 Total Proposed Modified Loads: 52.92 PASS Total Baseline Loads: 53.57 1 hereby certify that the plans and specifications covered by Review of the plans and O4'CHB S79�. this calculation are in compliancify-the Florida En specifications covered by this =_ O Code. calculation indicates compliance with the Florida Energy Code. +ix+.�; ,`,• "s '�.�` „ O PREPARED BY: Before construction is completed u o DATE: n5-9R- this building will be inspected for compliance with Section 553.908 ty., * u I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida C-ae ode. COP W'k OWNER/AGENT--4= BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifiesas certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Ft� co?( 5/26/2020 11:30 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 7 Block 5 Port St Lucie 15 Bedrooms: 3 User Conditioned Area: 1512 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 7 Block/Subdivision: Waterslone PlatBook: Street: 5325 San Bendetto Pla County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1512 13608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 Main 1512 13608 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0 1512 ft' ---- 0.47 0 0.53 ROOF _ / V # Type Roof Gable Roof Materials Area Area Color Red Barr Solar SA Emitt Emilt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1691112 378 W Medium N 0.85 N 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1512 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) Main 30 Blown 1512 ft' 0.11 Wood 5/26/2020 11:30 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 NE Exterior Concrete Block - Int Insul Main 4.1 39 10 8 9 348.5 ft' 0 0 0.6 0 2 W Exterior Concrete Block - Int Insul Main 4.1 2 3 8 0 18.0 ft' 0 0 0.6 0 3 NW Exterior Concrete Block - Int Insul Main 4.1 18 1 8 3 149.2 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Int Insul Main 4.1 2 3 8 0 18.0 ft' 0 0 0.6 0 5 SW Exterior Concrete Block - Int Insul Main 4.1 53 7 8 7 459.9 ft2 0 0 0.6 0 6 SE Exterior Concrete Block - Int Insul Main 4.1 41 2 8 7 353.3 ft' 0 0 0.6 0 7 - Garage Frame - Wood Main 13 35 9 8 3 294.9 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 13 It 0 in 1 ft 4 in None None 2 NE 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft' 1 ft 0 in 0 It 10 in Drapes/blinds None 3 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 NW 3 Vinyl Low-E Double Yes 0.33 0.31 N 3.0 ft' 7 It 4 in 0 It 9 in Drapes/blinds None 5 NW 3 Vinyl Low-E Double Yes 0.33 0.21 N 15.0 ft2 1 It 4 in 1 It 0 in Drapes/blinds None 6 N 4 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 f1:2 1 ft 4 in 1 ft 0 in Drapes/blinds None 7 SW 5 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft' 1 ft 4 in 1 ft0 in Drapes/blinds None 8 SW 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft' 1 ft4 in 1 ft 0 in Drapes/blinds None 9 SE 6 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 W 8 ft 4 in 0 ft 10 in Drapes/blinds None 10 BE 6 Vinyl Low-E Double Yes 0.33 0.23 N 23.2 ft2 1 ft 4 in 0 ft10 in Drapes/blinds None 11 SE 6 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 W 1 ft 4 in Oft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 390 ft2 390 ft' 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1587.6 87.16 163.91 .1454 7 5/26/2020 11:30 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 28.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 28.4 kBtu/hr 947 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS _ / — Supply— V # Location R-Value Area — Return — Air Location Area Leakage Type Handler CFM 25 TOT CFM25 OUT ON RLF HVAC # Heat Cool 1 Attic 6 302.4 ft Main 75.6 ft- Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablee ]Thermosta[[t:]]Y r' Heat ng I Jan [X] Feb fX] Mar Venting (1 Jan (1 Feb IIIXIII Mar Ceiling Fans: [X] [X] Apr [ May l l JMy un E ] Ju [ ]Aug Jun 1 Jul I 1 Aug [X] [ ]Sep I 1 Sep [ ] l J lxl Oct [jX]] [X] Nov jrX'j [ ]Dee Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 Cooling (WEH) AM 78 PM 78 Heating (WD) AM 66 PM 68 Heating (WEH) AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 68 68 66 66 68 68 68 68 68 68 78 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 s0 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 5/26/2020 11:30 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.4 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1512 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.352 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.275 14. Heating system: Capacity 28.2 c) Area 7c. 174.2 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE I) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Sigaatur : Date: Address of New Home: 5325 San Bendetto Place City/FL Zip: Fort Pierce, FL 34951 5/26/2020 11:30:21 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1