HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
hxF. St IMM
Project Name: Lot 7 Block 5 Port St Lucie 1512 AGL
Builder Name: ADAMS HOME=CountV,
,
Street: 5325 San Bendetto Place
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florid
1. New construction or existing New (From Plans)
9. Wall Types (1641.9 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1347.00 ft2
b. Frame - Wood, Adjacent
R=13.0 294.94 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst rase? No
10. Ceiling Types (1512.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1512.00 ft2
6. Conditioned Floor area above grade (ft2) 1512
b. N/A
R= ft2
Conditioned Floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(174.2 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 302.4
a. U-Factor: Dbl, U=0.33 118.38 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 35.00 ft2
12. Cooling systems
kStu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 3.00 ft2
a. Electric Heat Pump
28.2 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 3.801 ft.
Area Weighted Average SHGC: 0.276
14. Hot water systems
8. Floor Types (1512.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ft2
b. Conservation features
EF: 0.940
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor' Area: 0.115 Total Proposed Modified Loads: 52.92
PASS
Total Baseline Loads: 53.57
1 hereby certify that the plans and specifications covered by
Review of the plans and
O4'CHB S79�.
this calculation are in compliancify-the Florida En
specifications covered by this
=_ O
Code.
calculation indicates compliance
with the Florida Energy Code.
+ix+.�; ,`,• "s '�.�` „ O
PREPARED BY:
Before construction is completed
u o
DATE: n5-9R-
this building will be inspected for
compliance with Section 553.908
ty.,
* u
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida C-ae ode.
COP W'k
OWNER/AGENT--4=
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifiesas
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
Ft� co?(
5/26/2020 11:30 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 7 Block 5 Port St Lucie 15 Bedrooms: 3
User Conditioned Area: 1512
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot # 7
Block/Subdivision: Waterslone
PlatBook:
Street: 5325 San Bendetto Pla
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1512 13608
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfI ID Finished Cooled Heated
1
Main
1512 13608 Yes 4
3
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0
1512 ft'
---- 0.47 0 0.53
ROOF
_ /
V #
Type
Roof Gable Roof
Materials Area Area Color
Red
Barr
Solar SA Emitt Emilt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1691112 378 W Medium
N
0.85 N 0.85 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1512 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Free Truss Type
1
Under Attic (Vented)
Main 30 Blown
1512 ft' 0.11 Wood
5/26/2020 11:30 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar Below
Space
_ 1
NE
Exterior
Concrete Block - Int Insul
Main
4.1 39
10
8 9
348.5 ft'
0
0 0.6
0
2
W
Exterior
Concrete Block - Int Insul
Main
4.1 2
3
8 0
18.0 ft'
0
0 0.6
0
3
NW
Exterior
Concrete Block - Int Insul
Main
4.1 18
1
8 3
149.2 ft2
0
0 0.6
0
4
N
Exterior
Concrete Block - Int Insul
Main
4.1 2
3
8 0
18.0 ft'
0
0 0.6
0
5
SW
Exterior
Concrete Block - Int Insul
Main
4.1 53
7
8 7
459.9 ft2
0
0 0.6
0
6
SE
Exterior
Concrete Block - Int Insul
Main
4.1 41
2
8 7
353.3 ft'
0
0 0.6
0
7
-
Garage
Frame - Wood
Main
13 35
9
8 3
294.9 ft2
0
0.23 0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NW
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NE 1
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
13 It 0 in
1 ft 4 in
None
None
2
NE 1
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft'
1 ft 0 in
0 It 10 in
Drapes/blinds
None
3
W 2
Vinyl Low-E Double
Yes
0.33 0.21
N
10.0 ft'
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
4
NW 3
Vinyl Low-E Double
Yes
0.33 0.31
N
3.0 ft'
7 It 4 in
0 It 9 in
Drapes/blinds
None
5
NW 3
Vinyl Low-E Double
Yes
0.33 0.21
N
15.0 ft2
1 It 4 in
1 It 0 in
Drapes/blinds
None
6
N 4
Vinyl Low-E Double
Yes
0.33 0.21
N
10.0 f1:2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
7
SW 5
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft'
1 ft 4 in
1 ft0 in
Drapes/blinds
None
8
SW 5
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft'
1 ft4 in
1 ft 0 in
Drapes/blinds
None
9
SE 6
Vinyl Low-E Double
Yes
0.33 0.23
N
30.0 W
8 ft 4 in
0 ft 10 in
Drapes/blinds
None
10
BE 6
Vinyl Low-E Double
Yes
0.33 0.23
N
23.2 ft2
1 ft 4 in
0 ft10 in
Drapes/blinds
None
11
SE 6
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 W
1 ft 4 in
Oft 10 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
390 ft2 390 ft'
64 ft
8 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .0004
1587.6 87.16
163.91
.1454
7
5/26/2020 11:30 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 28.2 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 15 28.4 kBtu/hr 947 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubTpe
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
_ / — Supply—
V # Location R-Value Area
— Return — Air
Location Area Leakage Type Handler
CFM 25
TOT
CFM25
OUT
ON
RLF
HVAC #
Heat Cool
1 Attic 6 302.4 ft Main
75.6 ft- Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programablee ]Thermosta[[t:]]Y r'
Heat ng I Jan [X] Feb fX] Mar
Venting (1 Jan (1 Feb IIIXIII Mar
Ceiling Fans: [X] [X]
Apr [ May l l JMy un E ] Ju [ ]Aug
Jun 1 Jul I 1 Aug
[X]
[ ]Sep
I 1 Sep
[ ]
l J
lxl
Oct
[jX]]
[X] Nov
jrX'j
[ ]Dee
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6 7
8
9
10
11
12
Cooling (WD) AM 78
PM 80
Cooling (WEH) AM 78
PM 78
Heating (WD) AM 66
PM 68
Heating (WEH) AM 66
PM 68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78 78
78 78 78 78
78 78 78 78
78 78 78 78
66 66 68 68
68 68 68 68
66 66 68 68
68 68 68 68
78
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
s0
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft 0.3
Main
5/26/2020 11:30 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy
Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
28.4
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1512
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.352
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.275
14. Heating system: Capacity
28.2
c) Area
7c. 174.2
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
I) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1. 13.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11a. 30.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11 c. d) Multizone cooling credit
d) Radiant barrier installed 11 d. No e) Multizone heating credit
f) Programmable thermostat Yes
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Sigaatur : Date:
Address of New Home: 5325 San Bendetto Place City/FL Zip: Fort Pierce, FL 34951
5/26/2020 11:30:21 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1