HomeMy WebLinkAboutEnergy CodeFORM R405-2017
PLORIDA ENERGY EFFICIENCY CODE
Florida Department of Business and Professional R
rr. V
'F: i nG
0 od d
1LDING CONSTRUCTION
[a ion - Residential Performance Method
Project Name: Lot 14 Block 47-7 Port St Lucie 2010 BGL Builder Name:
ADAMS HOMES
Street: 5000 Sunset Boulevard Permit Office:
City, State, Zip: Fort Pierce , FL , 34982 Permit Number:
Owner: Jurisdiction:
631000
Design Location: FL, ST_LUCIE_CO_INTL County:
St. Lucie (Florida Climate Zone 2 )
i
1. New construction or existing New (From Plans)
9. all Types{1472.0 sqft.) Insulation Area
2. Single family or multiple family Single-family
a. ConcretelBlock - Int Insul, Exterior R=4.1 1308.00 ft'
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent R=13.0 164.00 ft2
c. N/A R= ft2
4. Number of Bedrooms 3
d. N/A R= ft2
5. Is this a worst case? No
10. Ceiling Typles (2010.0 sqft.) Insulation Area
a. Under Att c (Vented) R=30.0 2010.00 ft2
6. Conditioned floor area above grade (ft2) 2010
b. N/A R= ft2
Conditioned floor area below grade (ft2) 0
a N/A I R= ft2
7. Windows(198.3 sqft.) Description Area
11. Ducts R ft2
a. Sup: Atticl, Reb Main, AH: Main 6 402
a. U-Factor: Dbl, U=0.33 134.19 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 46.38 ft2
12. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Upit 35.0 SEER:15.50
c. U-Factor: Dbl, U=0.55 17.78 ft'
SHGC: SHGC=0.70
13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.879 ft.
Area Weighted Average SHGC: 0.267
14. Hot water Systems
8. Floor Types (2010.0 sqft.) Insulation Area
a. Electric Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2010.00 ft2
Conserve' EF: 0.940
b. Conseryfeatures
b. N/A R= ft2
None
c. A R= ft
15. Credits Pstat
Glass/Floor Area: 0.099 Total Proposed Modified Loads: 57.02i
PASS
Total Baseline Loads: 59.89
I hereby certify that the plans and specifications covered by
Review of the p
lans and STq?a
this calculation are in complian i he Florida E
specifications covered
Q4iIiE
by this p *v = pA
Code.
calculation indicates
compliance
PREPARED BY:
with the FloridaI
Energy Code. t4 r+nu '• :• 'OO
"
Before construction
is completed
a o
DATE: 11-6-19 Winn Kanmany
this building wily
be inspected for
compliance with
Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statute.
with the Florida E
Gpb �rt3
WE
OWNER/AGENT
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certification bIF y the air handler unit manufacturer that the l air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 AGH50 (R402.4.1.2).
File Copy
11/6/2019 2:07 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Editiop (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT 141IMMARV rl4;=rWl lCT =OnoT
_
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 14 Block 47-7 Port St Luci Bedrooms: 3
User Conditioned Area: 2010
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
631000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Lot Information
Lot # 14
Block/Subdivision: IndianRiverEst
PlatBook:
Street: 5000 Sunset Boulevard
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34982
CLIMATE
/
v Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2010 17286
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
2010 17286 Yes 5
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 163.4 ft 0
2010 ft2 ---- 0.35 0 0.65
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2248 ft2 504 ft2 Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2010 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2010 ft2 0.11 Wood
11/6/2019 2:07 PM EnergyGaugeB USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT RI IMMARY rHt=r-Wl iICT Or-OnOT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
0
1
NW
Exterior Concrete Block - Int Insul Main
4.1 36 0 8
0
288.0 ft2
0
0 0.6
0
2
SW
Exterior Concrete Block- Int Insul Main
4.1 21 6 8
0
172.0 ft2
0
0 0.6
0
3
SE
Exterior Concrete Block - Int Insul Main
4.1 36 0 8
0
288.0 W
0
0 0.6
0
4
NE
Exterior Concrete Block - Int Insul Main
4.1 56 0 8
0
448.0 ft'
0
0 0.6
0
5
-
Garage Frame - Wood Main
13 20 6 8
0
164.0 ft'
0
0.23 0.01
0
6
SW
Exterior Concrete Block- Int Insul Main
4.1 14 0 8
0
112.0 ft2
0 0.6
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SW Insulated Main
None
.25
3
6 8
20 ft2
2
- Wood Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
NW 1 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft2
1 It 4 in
0 ft 11 in
None
Exterior 5
2
SW 2 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 11 in
None
Exterior 5
3
SW 6 Vinyl Low-E Double Yes
0.33 0.21 N
23.2 ft'
6 ft 0 in
1 it 6 in
None
Exterior 5
4
SE 3 Vinyl Low-E Double Yes
0.33 0.23 N
4.7 ft2
1 ft 4 in
0 It 11 in
None
Exterior 5
5
NE 4 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft2
1 ft 4 in
0 ft 6 in
None
None
6
NE 4 Vinyl Low-E Double Yes
0.33 0.23 N
80.9 ft2
1 It 4 in
oft 11 in
None
Exterior 5
7
SW 6 Vinyl Low-E Double Yes
0.33 0.21 N
23.2 ft2
1 ft 4 in
0 ft 11 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
425 ft2 425 ft2
64 ft
8.6
It
1
INFILTRATION
#
Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000383 2016.7 110.71 208.21
.1364
7
HEATING SYSTEM
If
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
HSPF:8.5
34.6 kBtu/hr
1
sys#1
11/6/2019 2:07 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
•
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 15.5 35 kBtu/hr
1167 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
W
DUCTS
/ ---- Supply---
---- Return ---- Air
CFM 25 CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type Handler
TOT OUT
ON
RLF
Heat Cool
1 Attic
6 402 ft'
Main
100.5 ft Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programablre
Crreiling Fans:
,Thermostat:
1jY
Venting Jan [X] Feb
Venting
r'
fXl Mar
Apr
(([ f[` J]
Jun Jul Aug
r[` ]j
Sep
[ ] Nov
Dec
€
[ j Jan [[[[ 1] Feb
L J
[Xl Mar
[
May lMayXl
Jun [ Jul I Aug
lX� lXl
[ Sep
lXJ
Oct
lxl Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6 7
8 9
10
11
12
Cooling (WD) AM
PM
78
80
78 78
78 78 78 78
78 80
80
80
80
80 78
78 78 78 78
78 78
78
78
78
Cooling - (WEH) AM
PM
78
78
78 78
78 78
78 78 78 78
78 78
78
78
78
78 78 78 78
78 78
78
78
78
Heating (WD) AM
PM
66
68
66 66
68 68
66 66 68 68
68
68 68
68
68
68
68 68 68
68 68
68
66
66
Heating (WEH) AM
PM
66
68
66 66
68
66 66 68 68
68 68
68
68
68
68
68 68 68 68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8lbs/sq.ft.
0 ft'
0 ft 0.3
Main
11/6/2019 2:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANC INDEX* = 95
The lower the Energy Performance Index, the m re efficient the home.
1. New home or, addition 1. New (From Plans) 12. DL cts, location & insulation level
a) 3upply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) eturn ducts R 6.0
3. No. of units (if multiple -family) 3. 1 c) AHU location Main
i
4. Number of bedrooms 4. 3 13. Cooling system: Capacity 35.0
a) Split system SEER 15.5
5. Is this a worst case? (yes/no) 5. No b) tgle package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 2010 d) �oom unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.350
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.267 14. Helating system: Capacity 34.6
c) Area 7c. 198.3 a) plit system heal pump HSPF 8.5
b) Single package heat pump HSPF
8. Skylights c) bectric resistance COP
a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) &as furnace, LPG AFUE
f) tither
9. Floor type, insulation level:
a) Slab -on -grade (R-value) 9a. 0.0
b) Wood, raised (R-value) 9b. 15. W ter heating system
c) Concrete, raised (R-value) 9c. a) lectric resistance EF 0.94
b) gas fired, natural gas EF
10. Wall type and insulation: c) gas fired, LPG EF
A. Exterior: d) 01ar system with tank EF
1. Wood frame (Insulation R-value) 10A1. e) adicated heat pump with tank EF
2. Masonry (Insulation R-value) 1 OA2. 4.1 f) eat recovery unit HeatRec%
B. Adjacent: g) �ther
1. Wood frame (Insulation R-value) 1081. 13.0
2. Masonry (Insulation R-value) 1 OB2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11 a. 30.0 b) Cross ventilation No
b) Single assembly 11 b. C) l�/hole house fan No
c) Knee walls/skylight walls 11 C. d) Multizone cooling credit
d) Radiant barrier installed 11 d. No e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conslervation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Co nervation, through the above energy
saving features which will be installed (or exceeded) in this home before final inlspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. i
f 2
Builder Signature \ Date: �17
r
Address of New Home: 5000 Sunset Boulevard City/FLIZip: Fort Pierce FL 34982
11/6/2019 2:07:19 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBI 6th Edition (2017) Compliant Software Page 1 of 1