Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 PLORIDA ENERGY EFFICIENCY CODE Florida Department of Business and Professional R rr. V 'F: i nG 0 od d 1LDING CONSTRUCTION [a ion - Residential Performance Method Project Name: Lot 14 Block 47-7 Port St Lucie 2010 BGL Builder Name: ADAMS HOMES Street: 5000 Sunset Boulevard Permit Office: City, State, Zip: Fort Pierce , FL , 34982 Permit Number: Owner: Jurisdiction: 631000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) i 1. New construction or existing New (From Plans) 9. all Types{1472.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. ConcretelBlock - Int Insul, Exterior R=4.1 1308.00 ft' 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 164.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Typles (2010.0 sqft.) Insulation Area a. Under Att c (Vented) R=30.0 2010.00 ft2 6. Conditioned floor area above grade (ft2) 2010 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 a N/A I R= ft2 7. Windows(198.3 sqft.) Description Area 11. Ducts R ft2 a. Sup: Atticl, Reb Main, AH: Main 6 402 a. U-Factor: Dbl, U=0.33 134.19 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 46.38 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Upit 35.0 SEER:15.50 c. U-Factor: Dbl, U=0.55 17.78 ft' SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.879 ft. Area Weighted Average SHGC: 0.267 14. Hot water Systems 8. Floor Types (2010.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2010.00 ft2 Conserve' EF: 0.940 b. Conseryfeatures b. N/A R= ft2 None c. A R= ft 15. Credits Pstat Glass/Floor Area: 0.099 Total Proposed Modified Loads: 57.02i PASS Total Baseline Loads: 59.89 I hereby certify that the plans and specifications covered by Review of the p lans and STq?a this calculation are in complian i he Florida E specifications covered Q4iIiE by this p *v = pA Code. calculation indicates compliance PREPARED BY: with the FloridaI Energy Code. t4 r+nu '• :• 'OO " Before construction is completed a o DATE: 11-6-19 Winn Kanmany this building wily be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statute. with the Florida E Gpb �rt3 WE OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: Compliance requires certification bIF y the air handler unit manufacturer that the l air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 AGH50 (R402.4.1.2). File Copy 11/6/2019 2:07 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Editiop (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT 141IMMARV rl4;=rWl lCT =OnoT _ PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 14 Block 47-7 Port St Luci Bedrooms: 3 User Conditioned Area: 2010 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 631000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot # 14 Block/Subdivision: IndianRiverEst PlatBook: Street: 5000 Sunset Boulevard County: St. Lucie City, State, Zip: Fort Pierce , FL , 34982 CLIMATE / v Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2010 17286 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2010 17286 Yes 5 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 163.4 ft 0 2010 ft2 ---- 0.35 0 0.65 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2248 ft2 504 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2010 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2010 ft2 0.11 Wood 11/6/2019 2:07 PM EnergyGaugeB USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT RI IMMARY rHt=r-Wl iICT Or-OnOT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 NW Exterior Concrete Block - Int Insul Main 4.1 36 0 8 0 288.0 ft2 0 0 0.6 0 2 SW Exterior Concrete Block- Int Insul Main 4.1 21 6 8 0 172.0 ft2 0 0 0.6 0 3 SE Exterior Concrete Block - Int Insul Main 4.1 36 0 8 0 288.0 W 0 0 0.6 0 4 NE Exterior Concrete Block - Int Insul Main 4.1 56 0 8 0 448.0 ft' 0 0 0.6 0 5 - Garage Frame - Wood Main 13 20 6 8 0 164.0 ft' 0 0.23 0.01 0 6 SW Exterior Concrete Block- Int Insul Main 4.1 14 0 8 0 112.0 ft2 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 It 4 in 0 ft 11 in None Exterior 5 2 SW 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 11 in None Exterior 5 3 SW 6 Vinyl Low-E Double Yes 0.33 0.21 N 23.2 ft' 6 ft 0 in 1 it 6 in None Exterior 5 4 SE 3 Vinyl Low-E Double Yes 0.33 0.23 N 4.7 ft2 1 ft 4 in 0 It 11 in None Exterior 5 5 NE 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 1 ft 4 in 0 ft 6 in None None 6 NE 4 Vinyl Low-E Double Yes 0.33 0.23 N 80.9 ft2 1 It 4 in oft 11 in None Exterior 5 7 SW 6 Vinyl Low-E Double Yes 0.33 0.21 N 23.2 ft2 1 ft 4 in 0 ft 11 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 425 ft2 425 ft2 64 ft 8.6 It 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000383 2016.7 110.71 208.21 .1364 7 HEATING SYSTEM If System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 11/6/2019 2:07 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT • COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None W DUCTS / ---- Supply--- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 402 ft' Main 100.5 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablre Crreiling Fans: ,Thermostat: 1jY Venting Jan [X] Feb Venting r' fXl Mar Apr (([ f[` J] Jun Jul Aug r[` ]j Sep [ ] Nov Dec € [ j Jan [[[[ 1] Feb L J [Xl Mar [ May lMayXl Jun [ Jul I Aug lX� lXl [ Sep lXJ Oct lxl Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 78 78 78 78 78 78 80 80 80 80 80 78 78 78 78 78 78 78 78 78 78 Cooling - (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8lbs/sq.ft. 0 ft' 0 ft 0.3 Main 11/6/2019 2:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANC INDEX* = 95 The lower the Energy Performance Index, the m re efficient the home. 1. New home or, addition 1. New (From Plans) 12. DL cts, location & insulation level a) 3upply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) eturn ducts R 6.0 3. No. of units (if multiple -family) 3. 1 c) AHU location Main i 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 35.0 a) Split system SEER 15.5 5. Is this a worst case? (yes/no) 5. No b) tgle package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2010 d) �oom unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.350 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.267 14. Helating system: Capacity 34.6 c) Area 7c. 198.3 a) plit system heal pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) bectric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) &as furnace, LPG AFUE f) tither 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. W ter heating system c) Concrete, raised (R-value) 9c. a) lectric resistance EF 0.94 b) gas fired, natural gas EF 10. Wall type and insulation: c) gas fired, LPG EF A. Exterior: d) 01ar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) adicated heat pump with tank EF 2. Masonry (Insulation R-value) 1 OA2. 4.1 f) eat recovery unit HeatRec% B. Adjacent: g) �ther 1. Wood frame (Insulation R-value) 1081. 13.0 2. Masonry (Insulation R-value) 1 OB2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. C) l�/hole house fan No c) Knee walls/skylight walls 11 C. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conslervation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Co nervation, through the above energy saving features which will be installed (or exceeded) in this home before final inlspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. i f 2 Builder Signature \ Date: �17 r Address of New Home: 5000 Sunset Boulevard City/FLIZip: Fort Pierce FL 34982 11/6/2019 2:07:19 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBI 6th Edition (2017) Compliant Software Page 1 of 1