Loading...
HomeMy WebLinkAboutREG SPECS - 7-14-20Bulletin LP -T R122H Type R122H First -Stage Regulator Introduction The Type R122H is an Underwriters Laboratories listed regulator designed for T.vo-Stage LP -Gas systems. The unit is designed to reduce the tank pressure to an outlet pressure of 10 psig. The compact size makes it ideal for small domestic applications and underground tanks. The outlet pressure setting is nonadjustable and is factory set at a nominal 10 psig. Screened drip - lip vents are oriented over the outlet as standard. Features • 20 Year Recommended Replacement Life - The R122H is designed using rugged time proven design concepts and constructed of corrosion resistant materials, both intemally and externally. With proper installation and periodic inspection and maintenance the R122H regulator will meet a 20 Year Recommended Replacement Life. • Dual Gauge Taps - Built-in 118 inch NPT gauge taps orificed to a number 54 drill size on both the inlet and outlet side of the regulator allow for easy testing. • Durability - A fluorocarbon valve disc is utilized to improve lockup performance in systems with contaminated gas. • Improved Regulation - A large fabric -reinforced diaphragm and stabilizer clip deliver accurate and stable regulation. • Easy Installation - The units compact size and easily accessible inlet and outlet wrench flats make installation easy even in the tightest installations. March 2010 Figure t. Type R122H Frsr-Stage Regulator Superior Overpressure Protection - The combination of a high rapacity relief valve and large vent provide overpressure protection that exceeds IJL standards. When used in conjunction with a R622 or R652, the two-stage system will limit the downstream pressure from the second -stage to 2 psig even in a double failure situation. • Corrosion -Resistant - Added corrosion resistance from an internal and external coating process for all castings prior to painting, stainless steel relief valve spring and retainer and a corrosion resistant relief valve seat. Positive Draining Spring Case - When installed properly with the spring case vent pointed down, the design allows moisture formed in the spring case to drain out limiting the problems with corrosion and freezing water in the spring case. www.FISHERregulators.com/lp 4r EMERSON. Process Management Bulletin LP -7: R122H Table 1. Ordering Informalron TYPE NUMBER CAPACITY BTUMR CONNECTIONS PROPANEM INLET x OUTLET NOMINAL OUTLET SETTING R122H-AA,! 1,100,000 t1 -mm x 1 4nM NPT 10 pscg (0.69 Bar) 1 Catty to OZf00 an 30 PS* R07 ban rife! amsmm =w 20% arota 1/14.1810 FW.A Figure 2. Type R 122 Dimensions atmos IMM) LP -Gas Equipamt Emerton Process Management Regulator Technologies. In& USA - Headquarters MdCf:nteq, Texas 75069.1872 USA Tctephw e: l (800) 558,%% Telephone:1(972) 5483574 For further information visit www. fisherreplators.corMp The Fstt 4 A C bpm is a Lr4srs=tk aro weft marls at Em&-mn t:WW Co An Dater tusks aro tae txWM ad taen Wa%ncbvp awrters Flatter MSM a mask owrte0 Qy Frslttr Co ttrara tM.. a bustsm ar Eators % Plot= Ktardoerrertt The IrsI M , at tab pttboCIbon are presented qtr bs0 Mwanw OarPosos oily, arc waft every eRbrt stat bamt meas tb mum mw ss Awy. u" are row b be ean*ue0 sss wmw as or duress artsttpom n ft amemb or =VMS eDasotbed txreat or afar use or wombaaywt nsSerna tat no co foully or mmm" tnt dtstpsts 0r qwCMCw1*M atsuch pwWM at asty cane Mcm n n400t. Peoasss kCfrtapnsetmzl predudp [adsrd n q sole r wm► tae for tde setec!>on. wa or MW4VW= or arty Pro"& P4SPWMaK4ty qtr PMPW aeteaoan. u3e aitd MRMft M of" r-r+orSon EMERSON.. °E'ttom IN ' or Te&J*b9ft ft- M. 2010: Ao RVO Received Process Management Bulletin 71.1:R622 Type R622 Pressure Reducing Regulator • Compart Desinn • Prote Scree . uinh rrnnn;ity • Inlet and Outlet Pressure Gauge Taps Figure i. iypr 8622 Prex:ma Raducmg Raqulnrw Introduction Type R622 direct -operated. spring-loaded regulators provide economical pressure reducing control in a variety of residential. commercial. and industrial FISHER - Relief Veight applications. These regulators can be used :ith natural. manufactured. or propane gases and have the same inlet and outlet pressure capabilities. C. EMERSON. Bulletin 71.1:R622 Specifications Body Size and End Connection Stylet) Pressure Registration 112 NPT inlet and outlet Internal Maximum Allowable Inlet Pressurett) Operating: 125 psig (8,6 bar) Emergency: 125 psig (8,6 bar) Except 1.8 to 2.2 -inches w.c. (4 to 5 mbar) spring range which has operating and emergency pressures of 60 psig (4,1 bar) Maximum Allowable Outlet (Casing) Pressure0) Operating to Avoid Internal Part Damage: 3 psid (0,21 bar d) above outlet pressure setting Emergency: 20 psi (1,4 bar) Outlet Pressure Ranges See Table 1 Orifice Size 118 -inch (3,2 mm) orifice Flow Coefficients Wide -Open Cs for Relief Sizing: 12.5 Weide-Open C. for Relief Sizing: 0.36 Cl: 35 IEC Sizing Coefficients XT 0.78 Fp: 0.82 FL: 0.89 Flow Capacities See Table 2 Relief Performance See Figure 4 Internal Relief Performance Start -to -Discharge is 8 to 22 -inches w.c. (20 to 55 mbar) for setpoints from 1.8 to 20 -inches w.c. (4 to 50 mbar) Start -to -Discharge is 140 to 200°% over setpoint from 20 -inches w.c. to 2.2 psig (50 to 152 mbar) Spring Case Vent Connections 314 NPT with removable screen Temperature Capabilities(') -20° to 160`F (-29' to 71 °C) Approximate Weight 2.35 pounds (1 kg) Construction Materials Body, Spring Case, Diaphragm Plate. and Orifice: Aluminum Diaphragm, Disk, and O-ring: Nitrite (NBR) Adjusting Screw and Pushpost: Delrin® Closing Cap: ASA Thermoplastic (UV -Ray Resistant) Control Spring: Zinc- plated steel Machine Screw, Spring Seat, and Lever. Zinc -plated steel Valve Stem: Zinc Relief Valve Spring, Relief Spring Retainer, Lever Pin, and Vent Screen: Stainless steel 1 7be Wma in Oft Suft fn or wW qWkcaW slaw" Mr4ow stmW not no wmeeaed. 0=6 a a MXk Owned by E I. dy Pw de marokas and Co. In addition, Type R622 regulators have internal relief across the diaphragm to help minimize overpressure. Any outlet pressure above the start -to -discharge point of the non-adjustable relief valve spring moves the diaphragm off of the relief valve seat, allowing excess pressure to bleed out through the screened spring case vent. Table 1. Outlet Pressure Ranges Specifications The Spedfcations section lists specifications forType R622 Pressure Reducing Regulators. As it originally comes from the factory, specifications for a given regulator are stamped on the spring case nameplate. OUTLET PRESSURE RANGE CONTROL SPRING PART NUMBER CONTROL SPRING COLOR CODE SPRING WIRE DIAMETER INCHES (nun) SPRING FREE LENGTH. INCHES (MM) 18 to 2.2-Mchm w.c. (4 to 5 mbar) T 14453TUO 12 Pulpae 0051(1.30) 3.40 (86.4) 5 to 7 -Indus w.c. (12 to 17 mbar) T 14398TOO 12 Orange 0.062 (1,58) 3.40 (86.4) 6.5 to 94ncnes w.c. (16 to 22 Inbar) T 1439970012 Yellow 0.067 (1.70) 3.61 (91,7) 9 to 134nC n w.c. (22 to 32 mbar) T 1440070012 Saver 0.072 (1.83) 4.10 (104) 13 to 204 ndies w.c. (32 to 50 Inbar) T 14401 T0012 Gray 0.080 (2.03) 3.60 (91.4) 16 to 35 -tram w.c. (40 to 87 mbar) T 14402T0012 Pack 0093(2.36) 3.52 (89.4) 1 to 2.2 psig (69 to 152 mbar) T14403T0012 LUPI Blue 0 105 (2.67) 3.66 (93.0)