HomeMy WebLinkAboutConstruction PlansDESIGN CRITERIA: APPLICABLE CODES. REGULATIONS & STANDARDS 1. THE 2017 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUEL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-10 & SEI7 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFRENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY I. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED. PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = C FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 43 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 34 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 12 PSF VERTICAL PRESSURES ON SOLID SURFACES = 36 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = .6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8'k8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: L PORTLAND CEMENT TYPE 1 -ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 III. AIR ENTRAINING +/- I %- ASTM C 260 iv. WATER REDUCING AGENT-ASTM C 494 v. CLEAN PORTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: i. REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM A185 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. I. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #5 X W REBAR INTO EX. FOUNDATION WITH I"MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH I" MIN. HOLE, EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. ALUMINUM SPECIFICATIONS I. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH # 12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 5. I"X2" & I"X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1 /2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE # 14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10 X 1-I/2"SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1"X2" INSTALLED THROUGHOUT AN "OPEN VIEW' SPACING SHALL BE REDUCED TO I W O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS I. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK W/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE 2 x 4 SMB: 2'x4k0.044'k0.100" UNLESS OTHERWISE INDICATED. RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE' WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2'x2"x0.044" 2 x 3: 2x3'k0.050" 2 x 4: 2'k4"x0.050" 2 x 5: 2"xS"x0.050" OPEN BACK SECTIONS I x 2: 1'k2'k0.044" 1 x 3: MA3"0.045" SNAP SECTIONS 2 x 2 SNAP: 2"XZ<0.045" 2 x 3 SNAP: 7k3'k0.050" 2 x 4 SNAP: 2'k4"x0.045" SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044"x0.100" 2 x 5 SMB: 2"x5'k0.059k0. 109' 2 x 6 SMB: 7Sc6'4.059'x). 12W 2 x 7 SMB: 2'k7'k0.057'k0. 120" 2 x 8 SMB: 2'k8"x0.072"x0.124" 2 x 9 SMB: 2"x9"x0.082"x0.124" 2 x 10 SMB: 2'k10'k0.092"x0.398" DETAIL A BUILDISNG!� DIVISI STLCCOUNT REVIEWED FOR COM ON ' REVIEWED BY BE K PT ON 305 DATE WILL BE MADE n�NS AND PERMIT ONES) SITE OR NO INSPECTI cowl : 2 Qom: tv N LL 6. LQ a o =C7:v W 0.. m Q Or N o q Nr-6'-9"-- j--6'-9"-{--{1'-6" 2X3X.050DIAG.BRACETYP. co 4c � CO u1X2 2X2 X X "//nn[II11000\ p N N m O � N x X N X C) U-) o N r � M 1X2 + 2X2 (� ~ M = Z Z C C U I I _ O U "'-------------- Lu —i O 0 W Q LLLo � Z � LLi � ~ aD fn M `J H C rn WQOJ�N cr— < ¢v C) Q U 0 � a' O O N W aco LJ o N O Z U w O of d i-10 0 r39'-6"�� 4'- U) w w LL ILL Z w W Z o �� �mw ° (0 a w�a U N H Li Y O W a w64 LE w i= 9 6 9 1'-6" G `� G DESIGN DATE: 06/23/2020 REVISION 1: DATE REVISION 2: DATE PAGE: DRAWN BY: TCP SCALE: NTS r 1X2 % �\ 2XSSM8 N X it i X N X + / I i I 2XSSM8 I I I + 2XSSM8 Ir / / Lll j ' L 1X2 \ ; HOST 18" O/H STRUC. GUTTER 71111 2X2 TYP. i m m m m m I I I � I V�^f N � N N N I X N X N X N X N X N N q 2X2 TYP. I � N I I 2X2 TYP. I i I I I i 0"max 1X2 + 2X2 Ifl tl1 Ill Vl N X X N N N N � m 2X2 TYP. � � N N X X 1X2 TYP. 5' OR Tx6" WIDTHx0.250" EXTRUDED GUTTER BRACKET @ EA. BEAM W/ (4) #12x3/4- S.M.S. INTO GUTTER LIP I"x2"XOD45" OPEN BACK W/ (2) #12x2- INTO GUTTER & (1) 912x 2" @ 24" O.C. o BEAM 1 O O O Z"x2'xl/W X ALUMINUM ANGLE W/ (2) #14x3/4' S.M.S. INTO BEAM ON EA SIDE (4) INTO GUTTER OPTIONAL: 2'#'x0.062" RECEMNG CHANNEL W/ (2) #10x3/4" EA SIDE TO COVER EXPOSED BEAM NOTE:. 2x4 SMS BEAM ONLY REQUIRES 4" WIDTH GUTTER BRACKET Wl (2) 3/8' LAGS (4) 3/8- LAG SCREWS @ 1-12- SPACING @ EA GUTTER BRACKET & (1) @ 12 O.C. MAX -MIN EMBEDMENT SHALL BE 2' THE HOST STRUCTURE SHALL HAVE AT LEAST A 2"x4" FASCIA AND ROOF TRUSS SYSTEM. CONTRACTOR SHALL (4)#14x3/4"S.M.S. VERIFY THIS AND IF INTO GUTTER EA SIDE SMALLER CONTRACTOR SHALL BRING STRUCTURE UP TO A 2"x4" FASCIAAND ENSURE LESS THAN A 2-W OVERHANG GUTTER BRACKET & BEAM ATTACHMENT DETAIL SCALE:NTS NOTES: 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (4) OIGXSW S.M.S. MINIMUM. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE W/ (2) HINGES MINIMUM. 3. HI NOS SHALL BE ATTACHED TO DOOR WITH (4) #10x51W S.M.S. FASTEN A 1"x2"x0.044"TO UPRIGHT W/#12XI- S.M.S. @ 12' O.C. AND WITHIN 3" FROM END OF THE UPRIGHT. TYPICAL SCREEN DOOR CONNECTION DETAIL SCALE:NTS BEAM SCREWS Tx4"SMB 6 2'x5'SMB 6 TX6"SMB 8 2'x7"SMB 8 2"xe' SMB 10 2"xTSMB 10 2"xlT SM13 12 2"x_PURUNS (SEE A.1 FOR SIZE) ATTACHED TO BEAM W/ MIN. (4) 910A 12- SMS N 0 0 o o O 0 0 o\ O g1 O \O O \ \ N\\\ ..die ♦ _..P\ATi ' "SI" "S2' "S3" "S4" 3/4- 112" IT 3.75- 3/4" 1 IlT 16" 4.75" 1" 1112" IT 5.7T F 6 1'1 1/2' 22" 6.75' 7 1" 1 3/8" 23' 7.75"7 1" 13(8" 23' 8.75- 8 IN 1 1/4" 24" 9.75" -3116- ALUMINUM GUSSET PLATE #14 SMS o �m O `, O O O O O NOTES: 1.'N" NUMBER OF SCREWS IN ANY DIRECTION. 2. TOTAL NUMBER OF SCREWS PER JOINT EQUALS 4 TIMES "B'. 3. PLATE WIDTH SHALL BE DETERMINED FROM ANGLE OF BEAM AND MIN SPACE REQUIRED. 4. GUSSET PLATES MAY BE INTERNAL OR EXTERNAL. 5. INTERNAL SCREWS FOR PURLIN CONNECTION MAY BE INCLUDED IN TOTAL NUMBER OF SCREWS. 6. GABLE SPUCE WILL HAVE THE SAME PATTERN. BEAM SPLICE GUSSET DETAIL TYPICAL SCALE:NTS MAINTAIN MIN, OF 51T SEPERATION FROM EDGE OF BEAM SMS O.C. SELF -MATING BEAM SHALL BE NOTCHED FOR SLOPED BEAMS FOR UPRIGHT MAINTAIN ALL SCREW SPACING FROM EDGE OF BEAM /'% tea. I I_ 2"x2" EAVE RAIL SECTION (UNLESS OTHERWISE SHOWN iI S-2) ATTACHED TO BEAM W/ O 0,ON (4)104" SMS INTO SCREW O O BOSS O OII l'x2" OPEN BACK EAVE Oil RAILATTACHEDTO 10II UPRIGHT W/ (2) #10xl 12" SMS INTO SCREW BOSS #10x1 12" SMS 24" C/C --4- (MIN) UPRIGHT (SEE TABLE ABOVE) UPRIGHT TO BEAM CONNECTION - ALL WIND ZONES SCALE:NTS 1 12"xl/lT PLATE (TOP OR BOTTOM) 1"x2" FASTENED TO COLUMN WITH (2) #10xl 12' SMS INTO SCREW BOSSES FOR SMS OR SNAP COLUMN ........... � •' �- 2 h o =Z:O LU O•. LU N 1ULI0 1D W Q O: =U` 0 ? y'•: z c ui O (12) #12xl' SCREWS @ 1- SPACING 2"x2" EDGE BEAM (UNLESS OTHERWISE SHOWN ON SHEET 5.2) INTO SCREW BOSSES CONNECTING EDGE BEAM TO PURLIN SNAP NOTE: A RECEIVING CHANNEL (111T THICKNESS) WITH (4) #10x3/4" SMS AT EACH CONNECTION MAY BE USED IN PLACE OF THE (2) 410x3" SCREW BOSS CONNECTION. SLOPED OR FLAT PURLIN CONNECTION DETAIL SCALE:NTS Gdol (4) #10x3/4" SMS FASTENING SECONDARY ANGLE TO COLUMN (TYP EACH SIDE) (B) 3/8' 0 CONCRETE SCREW ANCHOR INTO SECONDARY ANGLE (TYP EACH SIDE) (SEE TABLE) ANCHOR SPA (MIN) (TYP) (SEE TABLE) COLUMN SIZE a/&' 0 CONCRETE SCREW ANCHOR B MIN SPA 2X3 0 0 2X4 1 3 2X5 1 3 2X6 1 4 2X7 1 5 2X8 2 3 ZX9 2 4 2X10 2 4.5 NOTES: SECONDARY ANGLE MIN 0A25" THICK (NOT REQUIRED FOR 2x3 MEMBER) RIMARY 2'x2" W 0.125"ANGLE 2) #10x3/4" SMS FASTENING OLUMN TO PRIMARY ANGLE TYP EACH SIDE) "x2"BASE MEMBER TYP EACH SIDE) 1) 318" 0 CONCRETE SCREW NCHOR INTO PRIMARY NGLE AND @ 1W 0 CONCRETE CREWANCHOR@ 4" O.C. BETWEEN COLUMNS (TYP EACH SIDE) 1. NUMBER OF ANCHORS'B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2 3/4' AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTH AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN PAVER DECK IS PRESENT. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED ON Si, D. FASTENERS, OTHER BRAND &TYPE SHALL BE APPROVED BY ENGINEER. 4. 2X3 W/ 1X2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. S.IF FOR AN IN -FILL, TOP OF COLUMN CONNECTIONS SIMILAR IF CONCRETE LINTEL IF WOOD LINTEL SUBSTITUTE 1/4" OX3" LAG SCREW FOR 3W 0 LOT FOR BOTH PRIMARY & SECONDARY ANGLES. 6. 2X2X.045 DOOR JAMB MEMBER SHALL CONNECT SIMILAR TO ZX3 MEMBER. 2"x3" OR LARGER UPRIGHT TO CONCRETE W/WO PAVER DETAILS SCALE:NTS \ PTION 91 -A-36 STEEL CLIP MAY BY PUKED ON ° �\ TOP OR SIDE OF DECK W/ y� SLEEVE TOP OF A ANCHOR L CONCRETE DOUBLE COMPRESSION c SLEEVES a O O e d 4"NOMINAL SLAB < < 4� MINIMUM 3/8"0X3'MASONRY OPTION #1 ANCHOR (MIN 3 3/4° 2500 PSI CONCRETE WI EMBEDMENT 4" SLAB ONLY WELDED WIRE OR FIBERMESH .125"STAINLESS e� STEEL CABLE 2500 PSI CONCRETE WELDED WIRE OR TOP OF FIDI ESH CONCRETE 4" MINIMUM I 1/2'X5 10 ALUMINUM OPTION #2 STRAP W/ (2) 31W OX3" USE WITH FOOTING MASONRY ANCHOR (MIN 3 3/4- EMBEDMENT) CABLE TO FOUNDATION CONNECTION DETAIL SCALENTS OPTION #1 (4) #10x1 1/2-SMS INTO SCREW BOSSES OPTION #2 Z'xT OR 2'4'� MEMBER .062"ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL W/ (4) #106/4' INTO BEAM OR 1 i UPRIGHT (2) #14x3/4" EA LEG INTO GIRT OR PURUN(0.062"ANGLE CLIPS W/ (2) #14.3/4- SMS EA LEG) FRIGHT OR BEAM - SNAP OR SELF MATING OR HOLLOW PURLIN OR GIRT TO BEAM OR POST DETAIL SCALE:NTS ANGLE 4) 912x3/4" SMS TYP TOP AND SIDE) W318- NOTE: WHEN USING OPTION #2 ' DIASTAINLESS CONNECTION CABLE MUST BE EEL CABLE WITHIN 66" OF CORNER OR PRIMARY MEMBER. INLESS STEELEYE BOLT (8) #74x314 SMS SIDE VIEW • 0 (MIN WASHER ; HENEATHNUT O O O O O O I I TOP VIEW OI 3/8"OADJUSTABLEEYE 0 BOLT FOR CABLE TENSION O OPTION #2 j O I I 1/8' 0 STAINLESS i STEEL CABLE SIDEVIEW ON 45'ANGLE OPTION #1 CABLE CONNECTION AT CORNER SCALE:NTS ANGLE cl vAll EDGE MEMBER ORPURUN ROOF' BRACE BRACE (2) #10x3" SMS CROSS SCREWING BRACE TO BEAM OR EAVE MEMBER (.125' BACKING PLATE USED) 2"x2'x.125' FLAT BAR (NP.) --(1) 3B' DIA. THRU B W/ NYLON LOCKINC OR THREAD LOCKIT MATERIAL APPLIED -EDGE MEMBER OR PURLIN ROOF BRACING CONNECTION DETAIL SGALE:NTS .... / O p. - � LU =U'C) i1 FW- K : ¢ O z ......p.R�x I111 i m i I I \1U\``` r J O L[) r O'j (n F— co V z Zoo Q E 0 O U W 0 00 �1 W Q 05 LULL 0-) C_ rn zJ G � ^c G � LLI Q 1 Y < U . 66. r- 0 C° o LL d 0 M N 00 �O N m U H V1 m W W m OJ LL ZW p y mU ? w }tea. 0 o a.mw m a Woa Q °0 U � 04 F Y w W 7 LL Z O C) n DESIGN DATE: 06/23/2020 REVISION 1: DATE REVISION 2: DATE I PAGE: DRAWN BY: TCP SCALE: NTS