Loading...
HomeMy WebLinkAboutAQVST Lot 7 E201 REV05 7/15/20WPGF GF 4-WAY WALL SWITCH DIMMER WALL SWITCH PUSH BUTTON SWITCH WEATHER PROOF GFCI OUTLET G.F.C.I. PROTECTED OUTLET DUPLEX OUTLET - HALF SWITCHED DUPLEX FLOOR OUTLET 3-WAY WALL SWITCH WALL SWITCH D ELECTRIC METER ELECTRIC PANEL 220 VOLT RECEPTACLE DUPLEX OUTLET DISCONNECT CENTRAL VAC. HOSE OUTLET PULL CORD FIXTUREPC KEYPAD THERMOSTAT INTERCOM SPRINKLER TIMER MOTION DETECTOR kp ST i T ELECTRICAL LEGEND DOUBLE CAT 5e CABLE tv CV C5 RECESSED ADJUSTABLE FIXTURE VAPOR PROOF RECESSED FIXTUREVP UNDER CABINET FIXTURE FLOOD/SECURITY LIGHTS FLOURESCENT LIGHT FIXTURE CEILING MOUNTED J-BOX RECESSED LIGHT FIXTURE CJ CEILING FAN WALL MOUNTED J-BOX CEILING MOUNTED FIXTURE WALL MOUNTED FIXTUREWF WJ CF EXHAUST FAN SMOKE DETECTOR SINGLE OUTLET PHONE JACKPH VIDEO OUTLET AHU 1 WH ACCU #1 STORAGE 9' Clg GARAGE 12'-10" Clg BONUS STORAGE ROOM 9' Clg LOBBY Volume Clg ELEVATOR MECH 1 9' Clg UP ACCU #2 ELEV EQUIP RE-CIR PUMP POOL EQUIP cen vac STORAGE 9' Clg POOL STORAGE 9' Clg AHU 2 ACCU #3 10x8 WALL LOUVER NRD 8x6 12"x12" DIRECTIONAL SUPLY AIR GRILL 400 CFM FAN CONTROlLED BY GARAGE CO SENSOR 10x8 WALL LOUVER 8x6 WF L2 D D CF CF DGFGFGF GF GF GF CFCF CFWPGFTO UPPER FLOOR SWITCH WF L2 D CFGF L3 WF L3 WF WF L5 WF L5 HARDWIRE w/ SWITCH WPGF D L1 L1 L1 L1 GF CF L6 NOTE: ELECTRIC, MECHANICAL, & PLUMBING SYSTEM COMPONENTS AT THIS LEVEL ARE NOT TO BE MOUNTED ON OR PENETRATE THROUGH WALLS THAT ARE DESIGNED TO BREAK AWAY UNDER FLOOD LOADS NON-BREAKAWAY STRUCTURAL CONCRETE COLUMN TYP. 11 1 MOUNT FIXTURE TO COLUMN MOUNT FIXTURE TO BEAM/SLAB ABV NOT BREAK AWAY WALL MOUNT VAC & RECEPTACLES TO COL 2 2 2 5 LT BBQ DRWA REF.OVENSCOOKTOP w/ HOOD ABV MASTER BEDROOM Coffer Clg 11'/11'-4" ELEVATOR PWDR 10' Clg WIC 10' Clg LIBRARY 11' Clg WIC 10' Clg UTIL 10' Clg BATH 6 10' Clg KITCHEN Coffer Clg 11'/11'-4" DINING 11' Clg PANTRY 10' Clg OUTDOOR LIVING 11' Clg GREAT ROOM 11' Clg UP DN WINE WALL ELEVATED DECK POOL SUN SHELF WIC 10' Clg SPA ENTRY OVERHANG 10' Clg MASTER BATH Coffer Clg 10'-6"/11' a/c chase22"x36" A.A.WF WF WF WF L1 L1 L1 L1 L1L1 L1L1 L2 L2 L2 L2 WPGF WPGF WF GF tv @ +60" w/ BACKING FOR TV MOUNT GF TO UPPER FLOOR SWITCH tv @ +60" (VERIFY HT.) w/ BACKING FOR TV MOUNT TO LOWER FLOOR SWITCH CFGFGFVPGFCF CF GFGFGFGFGFGF CFCF CF tv @ +60" (VERIFY HT.) w/ BACKING FOR TV MOUNT VERIFY LOCATION TO POOL LIGHTS L8 L8 L8 GFWF L5 WF L5 WF CF CF CF WF WF WF GFGFCF CF 1 1 GF 1 GF1 1 5 MOUNTING EXTERIOR LIGHTING FIXTURE SCHEDULE SYMBOL FIXTURE NAME BULB WATT & TYPE QUANTITY HEIGHT0 FLR 2 FLR TOTAL MOUNTING WALL 6'-6"L2 SAGA STEP LIGHT (HORIZ LOUVER) SG-R-1LED-HDL-AML (4) 1w AMBER LED PER FIXTURE WALL 12"L3 L4 4 -6 --2 WALL 8'-6"L5 2 -4 2 2 2 1 FLR 8 5w AMBER LED MR16 CEILING IN CEILINGL1-124 L6 H36LVTAT-3011-TBZBB (BRONZE) CEILING H36LVTAT-3011-SNBB (NICKEL) L7 NOTE: PER 62B-33.0155(1)(n) ALL WINDOWS AND GLASS DOORS VISIBLE FROM ANY POINT ON THE BEACH MUST BE TINTED TO A TRANSMITTANCE VALUE (LIGHT TRANSMISSION FROM INSIDE TO OUTSIDE) OF 45% OR LESS THROUGH THE USE OF TINTED GLASS OR WINDOW FILM VERIFY FIXTURE FINISHES WITH OWNER/INTERIOR DESIGNER VERIFY FIXTURES WITH DEP SUBMITTAL INTELLIBRITE LED 26W -TURTLE EDITION BELOW WATER LINE L8 3 -3-PENTAIR INTELLIBRITE 5G SeaGull 8313901EN-10 WALL SCONCE 9w AMBER LED A19 (1) 10w LED HINKLEY 1665TT LED CLG FLUSH MOUNT (1) 8w LED CEILING @ CEILING--11 TEKA 20" ARCADE HALF SHIELD ACQUAVISTA LOT #7VENETIAN ADMINISTRATION LLC7.10.2020ob No. 1802011 permit sets GS 10.5.2018 1 1st Building Comments GS 2.18.2019 2 2nd Building Comments GS 3.7.2019 3 As built roofing GS 6.24.2020 4 flood resistant materials GS 6.24.2020 5 elec meter/panel loc's GS 7.10.2020 E201 GARAGE LEVEL ELECTRIC PLAN SCALE: 3/16" = 1'-0" 1ST FLOOR ELECTRIC PLAN SCALE: 3/16" = 1'-0"