Loading...
HomeMy WebLinkAboutAQVST Lot 7 E101 REV05 7/15/20LOCATION TO FP&L TIE-IN ELECTRICAL RISER DIAGRAM METER (1) #2 CU TO 5/8" GROUNDING ROD & TO FOOTER STEAL (1) #2 CU. GND. WIRE TO H2O 150AMP 150AMP 150A PANEL B 40 CKTS M.L.O. A B ELECTRICAL METER & MAIN DISCONNECT UNDERGROUND A.I.C. 10,000 A.I.C. 10,000 POOL PANEL 60 AMP M.L.O. 150A PANEL A 40 CKTS M.L.O. (2) #6, 1 #6 NEUTRAL, (1) #10 GND IN 1" PVC (3) #2/0 CU & (1) #6 IN 2" PVC SERVING 2 AHU #1650 1 3 SERVING 2 4 POLEWIRE AMPSCIR #POLEWIRE AMPSCIR # 120/240150A VOLTAGEAMPSPNL 42 CKTS 3 WIRE 1 PHASE 2 ACCU #1650 KW 5.0 KW - 5 7 2 OVENS650 5.4 1 COOKTOP HOOD20 9 1 GARAGE DR OPENER1220 11 1 GEN'L LIGHTING1415 13 1 GEN'L LIGHTING1415 15 17 19 21 23 25 27 31 33 29 35 37 39 41 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 1 BATH GFI'S #11220 38 1.5 SPACE 40 42 ** GEN. L'TING (2,516 SF @ 3W/SF) PANEL A TOTAL KW =39.6 7.5 PANEL 'A' LOAD CALCULATIONS 25,700 W. 240 V. = 107.1 Amps 1st 10.0 KW @ 100% LARGEST OF: HEATING @ 65% COOLING @ 100% REMAINING KW @ 40% TOTAL KW 10.0 9.8 5.9 25.7 SERVING 2 ELEVATOR1030 1 3 SERVING 2 4 POLEWIRE AMPSCIR #POLEWIRE AMPSCIR # 120/240150B VOLTAGEAMPSPNL 42 CKTS 3 WIRE 1 PHASE 2 AHU #2660 KW 3.0 KW 10.0 5 7 6 8 9 11 13 15 1 KIT REF122017 1.5 1 SMALL APPLIANCE #21220 19 1.5 21 23 25 1.5 1.5 ** ** 27 29 31 33 35 37 39 41 10 12 14 16 1 WASHER1220 18 1.2 20 22 24 26 28 30 32 34 36 38 40 42 ** GEN. L'TING (2,517 SF @ 3W/SF) PANEL B TOTAL KW =39.1 7.4 PANEL 'B' LOAD CALCULATIONS 24,200 W. 240 V. = 100.8 Amps 1st 10.0 KW @ 100% LARGEST OF: HEATING @ 65% COOLING @ 100% REMAINING KW @ 40% TOTAL KW 10.0 6.5 7.7 24.2 SERVING SERVINGPOLEWIREAMPSCIR #POLEWIRE AMPSCIR # 120/24060P (POOL) VOLTAGEAMPSPNL 12 CKTS 3 WIRE 1 PHASE KW KW 2 POOL PUMP840 1 1.5 3 5 7 1 POOL LIGHTS12202 0.8 4 6 8 10 12 1 POOL CONTROLLER 9 SPACE 11 SPACE 12 20 0.5 1 POOL HEATER IGNITER1220 0.5 PANEL P TOTAL KW =3.3 PANEL 'P' LOAD CALCULATIONS 1st 10.0 KW @ 100% LARGEST OF: HEATING @ 65% (6.5 KW) COOLING @ 100% (KW) REMAINING KW @ 40% TOTAL KW 3.3 0.0 3.3 3,300 W. 240 V. = 13.8 Amps 1 GEN'L LIGHTING1415 1 GEN'L LIGHTING1415 ** ** 1 SMALL APPLIANCE #120 1.5 1 GEN'L LIGHTING1415 1 GEN'L LIGHTING1415 ** ** 1 GEN'L LIGHTING1415 1 GEN'L LIGHTING1415 ** ** 1 GEN'L LIGHTING1415 **1 GEN'L LIGHTING1415 ** 1 GEN'L LIGHTING1415 1 GEN'L LIGHTING1415 ** ** 1 GEN'L LIGHTING1415 1 GEN'L LIGHTING1415 ** ** 1 GEN'L LIGHTING1415 1 GEN'L LIGHTING1415 ** ** 1 GEN'L LIGHTING1415 1 GEN'L LIGHTING1415 ** ** 1 GEN'L LIGHTING1415 1 GEN'L LIGHTING1415 ** ** 1 GEN'L LIGHTING1415 1 GEN'L LIGHTING1415 ** ** 1 GEN'L LIGHTING1415 **1 GEN'L LIGHTING1415 ** SPACESPACE 1 GEN'L LIGHTING1415 **1 GEN'L LIGHTING1415 **1 GEN'L LIGHTING1415 **1 GEN'L LIGHTING1415 ** 2 DW & DISP #11220 2.2 SPACE SPACE 12 1 CEN VAC1220 1.2 1 RECIRCULATING PUMP1220 1.2 1 BATH GFI'S #21220 1.5 SPACE 2 ACCU #2660 - 2 AHU #3660 10.02ACCU #3650 - 2 WATER HEATER1030 4.5 2 COOKTOP650 5.0 2 DRYER1030 4.5 UTILITY ROOM 5 5 ELEVATOR NOTES: 1. ELEVATOR SHALL MEET NEC 620 22-23; VERIFY LOCATION AND ELECTRICAL REQUIREMENTS OF ELEVATOR EQUIPMENT WITH MFG SPECS PRIOR TO CONSTRUCTION. 2. IF THERE IS AN ELEVATOR PIT LOCATED BELOW, PROVIDE WITH FLOAT SWITCH SENSOR; LIGHT FIXTURE SHALL NOT BE INSTALLED IN ELEVATOR PIT. 3. PROVIDE A LIGHTING FIXTURE WITH RECEPTACLE OUTLET, CONTROLLED BY A SWITCH LOCATED AT THE PASSAGEWAY OPENING PER FMC 306.3.1. ELECTRICAL NOTES GENERAL: 1) CONTRACTOR SHALL VERIFY THE LOCATION OF SERVICE AND SHALL LOCATE THE METER & PANELS AS REQUIRED. 2) ALL WIRE SHALL BE THHN COPPER, UNLESS NOTED OTHERWISE. 3) WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS SHALL BE COPPER OF EQUAL AMPACITY. 4) ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED CABLE. 5) COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO CONSTRUCTION. 6) ROMEX MAY BE USED WHERE CONDUIT IS NOT REQUIRED. 7) BX CABLE MAY BE USED IN LIEU OF RIGID CONDUIT. 8) VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER SPECIFICATIONS. 9) PROVIDE DISCONNECT SWITCHES OF SIZE AS REQUIRED BY LOADS. 10) PROVIDE NON-FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIP. AND AT PUMPS NOT VISIBLE FROM CIRCUIT BREAKER PANEL AND AS PER MANUFACTURER RECOMMENDATIONS. 11) PROVIDE DISCONNECTS FOR POOL PUMP PER N.E.C. 680. POOL CONTRACTOR SHALL PROVIDE ELECTRICAL CONTRACTOR WITH ALL LOADS PRIOR TO INSTALLATION. ELECTRICAL CONTRACTOR TO MAKE ALL CONNECTIONS PER POOL COMPANY DRAWINGS. VERIFY LOCATION OF ALL POOL/SPA EQIUPMENT. 12) ALL 120 VOLT 15 AND 20 AMP CIRCUITS THAT SERVE FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, REC ROOMS, CLOSETS, HALLWAYS, OR SIMILIAR ROOMS TO BE ARC FAULT CIRCUIT PROTECTED PER FBCR E3902.12. 13) WIRES SMALLER THAN #6 SHALL HAVE THHN INSULATION, #6 & LARGER SHALL HAVE THWN INSULATION. FIXTURES: 1) PROVIDE GREEN WIRE GROUND TO ALL EXTERIOR FIXTURES AND "J" BOXES. 2) ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED AND AS SELECTED BY OWNER. 3) ALL LIGHTING FIXTURES AND FANS TO BE SELECTED & LOCATED BY OWNER/ARCHITECT/INTERIOR DESIGNER, UNLESS OTHERWISE NOTED. 4) ARCHITECT TO SET MOUNTING HEIGHTS FOR ALL FIXTURES WHERE APPLICABLE, UNLESS OTHERWISE NOTED. 5) FLUORESCENT CLOSET LIGHT FIXTURES SHALL HAVE A MINIMUM CLEARANCE OF 6" AWAY FROM CLOTHING. 6) PREWIRE FOR GARAGE DOOR OPENER SENSOR. 7) HIHATS TO BE 4" ROUND OUTLETS: 1) ALL COUNTERTOP RECEPTACLES SHALL BE GFCI OUTLETS. 2) PROVIDE GFCI BREAKERS FOR ALL BATHROOMS, GARAGE AND EXTERIOR OUTLETS AS SHOWN ON PLANS. 3) ALL 125 VOLT 15 AND 20 AMP RECEPTACLES TO BE TAMPER RESISTANT PER FBCR E3902.12. 4) PROVIDE PRE-WIRED TELEPHONE & CABLE T.V. OUTLETS AS SHOWN ON PLAN. PROVIDE OPTIONAL PRE-WIRED HIGHSPEED DATA OUTLETS AS SHOWN ON PLANS. (IF APPLICABLE) 5) FOR FLOOR RECEPTACLES, PROVIDE A COVER PLATE AND FLUSH WITH FLOOR. VERIFY EXACT LOCATION WITH GC/OWNER. PROVIDE 1/2" CONDUIT UNDER SLAB FROM WALL. SMOKE DETECTORS: 1) ALL SMOKE DETECTORS TO HAVE BATTERY BACK UP AND SIGNAL SIMULTANEOUSLY W/ TEMPORAL SOUND. 2) SMOKE DETECTORS TO BE LOCATED MIN 3'-0" FROM: R/A & SUPPLY GRILLS, KITCHENS, BATH ROOMS. 3) SMOKE DETECTORS TO BE COMBINATION TYPE CARBON MONOXIDE ALARM & SMOKE DETECTOR. WPGF GF 4-WAY WALL SWITCH DIMMER WALL SWITCH PUSH BUTTON SWITCH WEATHER PROOF GFCI OUTLET G.F.C.I. PROTECTED OUTLET DUPLEX OUTLET - HALF SWITCHED DUPLEX FLOOR OUTLET 3-WAY WALL SWITCH WALL SWITCH D ELECTRIC METER ELECTRIC PANEL 220 VOLT RECEPTACLE DUPLEX OUTLET DISCONNECT CENTRAL VAC. HOSE OUTLET PULL CORD FIXTUREPC KEYPAD THERMOSTAT INTERCOM SPRINKLER TIMER MOTION DETECTOR kp ST i T ELECTRICAL LEGEND DOUBLE CAT 5e CABLE tv CV C5 RECESSED ADJUSTABLE FIXTURE VAPOR PROOF RECESSED FIXTUREVP UNDER CABINET FIXTURE FLOOD/SECURITY LIGHTS FLOURESCENT LIGHT FIXTURE CEILING MOUNTED J-BOX RECESSED LIGHT FIXTURE CJ CEILING FAN WALL MOUNTED J-BOX CEILING MOUNTED FIXTURE WALL MOUNTED FIXTUREWF WJ CF EXHAUST FAN SMOKE DETECTOR SINGLE OUTLET PHONE JACKPH VIDEO OUTLET ACQUAVISTA LOT #7VENETIAN ADMINISTRATION LLC7.10.2020ob No. 1802011 permit sets GS 10.5.2018 1 1st Building Comments GS 2.18.2019 2 2nd Building Comments GS 3.7.2019 3 As built roofing GS 6.24.2020 4 flood resistant materials GS 6.24.2020 5 elec meter/panel loc's GS 7.10.2020 E101