Loading...
HomeMy WebLinkAboutGRAVEL REVIEW COMMENTSZoo Naco Rd, Suite C, Ft. Fierce, FL 34946 sunnnerUnsmarineconstruction@Umall.com 772.464.6090 July 15, 2020 Re: Permit Number: 2006-0774 Permit Type: Boat Lift Job address: 442 S Naranja Ave To St. Lucie County Building Department Plans Examiner Joseph Fersch In response to your plan review comments for the above referenced permit application, please find attached the electronically sealed drawings with the detail clouded in red. Respectfully, Ginger P. Hester Assistant to Joy Yancy Planning $ Developm. ant Service Building S Code Regulation Division 2300 Vir9kn is Aanue Fort Pierce; FIL U982 PROPERTY INFORMATION Address: 442 S Naranja Ave City / State / Zip: Port St. Lucie, FI 34983 Parcel #: 3419-530-0011-000/3 Zoning: RS -4 APPLICATION INFORMATION Permit Number: 2006-0774 Permit Type: BOAT LIFT WITH ELECTRIC CONTRACTOR INFORMATION Contractor Name: Joy S Yancy Business Name: Summerlin's Marine Construction Llc Business Addr: 200 Naco Rd #C City / State / Zip: Fort Pierce, FI 34946 REVIEWS AND COMMENTS REVIEW COMMENTS Page 1 Owner(s): Keith R Miller / Sandra Miller Jurisdiction: SAINT LUCIE COUNTY Lot#: 11 Block: 32 Stories: Automatic Sprinkler System? No Fax Number: 772-464-7470 Email: Summerlinsmarineconstructi on@Gmail.Com Review Type Status Reviewed By Date Started Date Co plete4 Date Released FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 6/25/2020 6/25/2020 6/25/2020 Comment: NOTIFIED FOR PICK UP PENDING Comment: PLANS EXAMINER REVIEW INCOMPLETE Joseph Fersch 6/25/2020 6/25/2020 Comment: PURSUANT TO SECTION 107 FBC 6TH EDITION. PROVIDE DETAIL OF STRINGER CONNATIONS AT THE CORNERS. ZONING REVIEW PENDING Comment: cc O 0 rt co a p w `p f0 n A ►t a�� 2 xl o ro I�� I y ✓ 0 :3 ca 'T7rf r- 0 ^ �Q 1, �, t;ll�) ao0 II �Cr4� c t-,:) o a w o p a a j 40.1 (4 II c II � t;ll�) ao0 II �Cr4� Engineer's Certification for Wind Load Compliance Project Name: Gravel Street Address: 442 S Narnaja Ave. Port St. Lucie, FL Construction Type: Dock Bowdoin G. Hutchinson P.E. 806 Delaware Ave. Fort Pierce, FL 34950 I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to meet or exceed the applicable structural portion of the Building Codes currently adopted and enforced by City of Port Saint Lucie. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: 1 Florida Building Code _201.7 Edition with —N/A Supplements and ASCE 7-10 2. Building Design is: Enclosed: Partially Enclosed: — Open Building: X 3. Mean Deck Height: _ 6'+ Roof Pitch: N/A Internal Pressure Coefficient: 0.0 4. Width of End Zone: 1' Wind Speed: (3 sec. gust) 5. Building Classification Table 1-1. ASCE 7-10 FBC Table 1604.5 1 6. Wind Exposure Classification: D Adjustment Factor for Exposure & Height:,_1.0 7. Components & Cladding Wind Pressure on Roof Zone 1 N/A 2 N/A 3 N/A PSF 8. Components & Cladding Wind Pressure on Wall Zone 4 +60.6/-64.1 5 +70.1/-74.5 PSF 9. Components & Cladding wind Pressure on Overhead Garage Door N/A _PSF 10. Loads: Floor 40 PSF Roof/dead N/A PSF Roof/live N/A PSF 11. Shear Walls Considered for Structure? Yes X No (if No, attach explanation) 12. Continuous Load Path provided? Yes X No (if No, attach explanation) 13. Are Component and Cladding Details Provided? Yes X _ No (if No, attach explanation) 14. Minimum Soil Bearing Pressure: N/A _ Presumptive: N/A _ By Test: N/A _ PSF Engineer's Note: All Aqueous structures shall be designed for a minimum 170 MPH Min. wind load regardless of wind zone. As witnessed by my seal, I hereby certify that the information included with this certification is true and correct, to the best of my knowledge and belief. Name: Bowdoin G. Hutchinson Cert #: PE# 70878 Date: 6/22/20