HomeMy WebLinkAboutEngineering Submittal Revision-DigiCert, Gravel, 442 S Naranja Ave, 6.29.20 (1)p o Ferry �`a 442 S NARAN✓A AVE RIVER PARK - UNIT FOUR BLOCK32-LOT 11 PB 11, PG 9 3419-530-0011-000-3 Channel Calculations Boat channel width = 135 LF 259' of canal = 33 LF Dock width extends = 5 LF Catwalk width extends = 18 LF Total = 23 LF into Boat channel 12 PROPOSED 4' CA TWALK 0ZO 1 "==25' 135E WIDE BOA T CHANNEL DN: Bowdoin cgb6Nzq,c=US,st=3rida,11 cgb6hOzq, c=US, st=Florida, I=1 Pierce, o=Bowdoin G. Hutchins cn=Bowdoin Hutchinson Date: 2020.06.2Hutchinson AdobeA obatves19:54ion45-04'C 2020.009.20067 087 OF Zz O /yA Ll I04 This item has been electronically signed and sealed by Bowdoin G. Hutchinson, P.E. using a Digital Signature and Date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Benchmark Engineering Gravel of the Treasure Coast LLC 1 Owjoin G, Hutchinson K, . Aquatic Structures Division 44Z S Narnaj a Ave FL# 70515 �c 8o6 Delaware Ave. Fort Pierce, FL 34950 �+ Port Saint Lucie, FL Engineer's Certification for Wind Load Compliance Project Name: Gravel Street Address: 442 S Narnaja Ave. Port St. Lucie, FL Construction Type: Dock Bowdoin G. Hutchinson P.E. 806 Delaware Ave. Fort Pierce, FL 34950 certify that, to the best of my knowledge and belief, these plans and specifications have been designed to meet or exceed the applicable structural portion of the Building Codes currently adopted and enforced by City of Port Saint Lucie. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: 1 Florida Building Code 2017 Edition with N/A Supplements and ASCE 7-10 2. Building Design is: Enclosed: Partially Enclosed: Open Building: X 3. Mean Deck Height: 6'+ Roof Pitch: N/A Internal Pressure Coefficient: 0.0 4. Width of End Zone: 1' Wind Speed: 175 (3 sec. gust) 5. Building Classification Table 1-1. ASCE 7-10 FBC Table 1604.5 1 6. Wind Exposure Classification: D Adjustment Factor for Exposure & Height: 1.0 7. Components & Cladding Wind Pressure on Roof Zone 1 N/A 2 N/A 3 N/A _PSF 8. Components & Cladding Wind Pressure on Wall Zone 4 +60.6/-64.1 5 +70.1/-74.5 PSF 9. Components & Cladding wind Pressure on Overhead Garage Door N/A _PSF 10. Loads: Floor 40 PSF Roof/dead N/A PSF Roof/live N/A PSF 11. Shear Walls Considered for Structure? Yes X No (if No, attach explanation) 12. Continuous Load Path provided? Yes X No (if No, attach explanation) 13. Are Component and Cladding Details Provided? Yes X _ No (if No, attach explanation) 14. Minimum Soil Bearing Pressure: N/A _ Presumptive: N/A _ By Test: N/A _ PSF Engineer's Note: All Aqueous structures shall be designed for a minimum 170 MPH Min. wind load regardless of wind zone. As witnessed by my seal, I hereby certify that the information included with this certification is true and correct, to the best of my knowledge and belief. Name: Bowdoin G. Hutchinson Cert #: PE# 70878 Date: 6/22/20