HomeMy WebLinkAboutProduct Approval r,
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications ( Contact Us i BCIS Site Map Links Search
H 'da
LA Product Approval
pA yUSER:Public User R
ECEIVED�
Product pnroval Menu>Application Detail
FL# FL1850-1111
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived ❑
Product Manufacturer American Shutter Systems Association,Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(_5U) 209-8263
bfeeley@easternmetal.com
Authorized Signature n Bill Feeley
Irodriguez@easternmetal.com
Technical Representative „
1
13
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Walter A.Tillit,Jr., P.E.
the Evaluation Report
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2020
Validated By John Henry Kampmann Jr.
Validation Checklist-Hardcopy Received
Certificate of IndependenceL1F 850 R11_COI_AMERICAN SHUTTER SYSTEMS, INC._DRAWING 17-
102_CERTIFICATE OF INDEPENDENCEYDF
Referenced Standard and Year(of Standard) Standard Year
ASTM E1886 2005
ASTM E1996 2005
ASTM E330 2002
TAS 201, 202, 203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/03/2017
Date Validated 10/13/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
'krs - S �;.ai"1 d��4s�1$9
Model,Number or Name Des+crrphon
.
1850.1 Bertha HV Accordion -Blade 3 Extruded aluminum blades folded together thru knuckles and
(HVHZ) Drawing# 17-103 retained by tracks to provide hurricane protection.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL1850 R11 II AMERICAN SHUTTER SYSTEMS ASSOC.,_
Approved for use outside HVHZ:Yes INCDRAWING 17-103 BERTHA HV ACCORDION SHUTTER
Impact Resistant:Yes SYST.PDF
Design Pressure: N/A Verified By: American Test Lab of South Florida, Inc.
Other: Large Missile Level "D". Max span is 12'-7"for 35 psf Created by Independent Third Party: Yes
positive ASD load and 13'-0"for 35 psf negative ASD load for Evaluation Reports
one specific condition shown in span tables. See additional FL1850 R11 AEAMERICAN SHUTTER SYSTEMS ASSOC.,
loads and spans on engineered drawings. INC. DRAWING 17-103 PRODUCT EVALUATION REPORTPDF
Created by Independent Third Party: Yes
1850 2 Bertha HV-Accordion Shutter Extruded aluminum interlocking blades retained by tracks(top
(Combo}»;,HVHZ :Drawing#'17=102 and:bottom or storm.protection
Limits"of tl'se Installatwn Instructions
Ap'praved"for use m"HVHZ Yes. „3 , " FL1850 R11'jj,AMERICAN SHUTTER-SYSTEMS,INC:
Approved-for useoeitsicJe HVHZ;Yes "pNG 17=-102 BERTHA HV ACCORDION SHUTTER
Im act Resilstantp.Yes
SYSTEM PDF'
Deaigrr"Pressure.``N/A Ver"�f�ed By'_American Test Lab of South Florida,Inc
Other:Large.Miss ;Level."D Max'span,is;13',2",for•.30 psf •"Created-.by Independent Third Part
iiey:Yes
nostwe ASD load vi/,p window blade 1"6-0"y{nr 30 psf Evaluation iteports s ,• r
egative ASD load,for HV1 blade w/o,window blade"for, FL1850 k 1= AMERICAN 5HUITER"SYSTEMS
condiiions'.irtlicatec!•:;on schedule#1sheet"12 And:1'2' 3';for DRA1hlING 17-102 R°8120[}l1CT'EVALUAI'ION-REPORTRDF
30 psf positive ASD load_w[o window blade and 15'4for 36 Created"by IndependentThird Party:"Yes
psf.negative ASD load for HV2 blade w/o window blade See
er snand
th2re`5,28 and 28A"of installation vu
dra (ngs for e
pans p sures_
1850.3 Bertha HV Accordion Shutter- Blade Extruded aluminum interlocking blades retained by tracks (top
1 Only(HVHZ)- Drwg# 17-122 and bottom)for storm protection
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL1850 R11 II AMERICAN SHUTTER SYSTEMS ASSOC. INC
Approved for use outside HVHZ:Yes DRAWING 17-122_BERTHA HV ACCORDION SYST..PDF
Impact Resistant: Yes Verified By: American Test Lab of South Florida, Inc.
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Large missile level"D". Max. span is 16'-0"and 14'-9" Evaluation Reports
for 30 psf ASD negative load depending on centermates and FL1850 Rli AEAMERICAN SHUTTER SYSTEMS ASSOC,
locking rod configuration for the HVI blade, 8'-0"for+64, -72 INC_DRAWING 17-12�PRODUCT EVALUATION REPORT.PDF
psf load for HV blade for Keystone mountings 7'-0"for+75, Created by Independent Third Party: Yes
-75 psf for metals stud mountings and 8'-0"for 110 psf. for
HV1 and HV1A working in unison. See sheets 7, 11, 20 and 19
respectively of installation drawings for other spans and
pressures.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.