HomeMy WebLinkAboutAP FL9777-R11Florida Building Code Online
12/26/19r 2:47 PM
r�
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Llnks Search
'f)ri�lc?
dopr 4 Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL9777-Rll
Revision
2017
Approved
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg-keeler@owenscorning.com
Greg Keeler
greg,keeler@owenscorn€ng.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Zachary R. Priest
PE-74021
UL LLC
12/31/2020
Locke Bowden P.E.
Validation Checklist - Hardcopy Received
FL9777_R11_COI_OCR14402.8a 2017 FBC Evaluation Report Weatherlock
Nan-HVHZ.pdf
Standard
Year
ASTM D 1970
2015
ASTM D 226
2009
ASTM G 155
2005
https://www.floridabuilding,orglprlpr_app_dti.aspx?param=vvGEVXQwtDgtgkcMGblcW71%2fZr7gdugvKEIMFg53ndVG01883S636Kw%3d%3d Page 1 of 3
Florida Building Code Online
12/26119, 2=47 PM
TAS 103
UL 1897
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/11/2017
Date Validated
10/11/2017
Date Pending FBC Approval
10/17/2017
Date Approved
12/12/2017
Summary of Products
1995
2012
FL #
Model, Number or Name
Description
9777.1
Weatherlock G
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777_R11_11_OCR14002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL977 _RII 6E_OCR14002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pdf
Created by Independent Third Party: Yes
9777.2 WeatherLock G (High Tear) _
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R11 II_OCR 4 02.8a 201Z FBC Evaluation Report
Approved for use outside HVHZ: Yes
Weatherlock Non-HVHZ,pddf
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777_R11 AE OCS14002.8a 2017 FBC Evaluation Report
Weathed-�k Non, HVHZRdf
Created by Independent Third Party: Yes
9777.3
Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL9777_ t�1_II_OCR14002.8b 2 0 IT FBC Evaluation Report
Weatherlock HVHZ.pdf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777_Rll AE_OCR14002.8b 2017 FBC Evaluation Report
Weatherlock HVHZ.odf
Created by Independent Third Party: Yes
19777.4 1 Weatherlock MAT f Waterproofing Underlayment
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use
Installation Instructions
FL9777_R11 II OCR14002.8a 2017 FBC EvaluatiorL-Report
Weatherlock Non-HVHZ. pdF
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777_R1.1 AE_OCR14002.8a 2017 FBC EvaluatiQn Report
Weatherlock Non-HVHZ,v
Created by Independent Third Party: Yes
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtgkcMGblcW71%2fZr7gdugvKElMFg53ndV601883S63BKw%3d%3d Page 2 of 3
Florida Building Code Online
12/26/19, 2:47 PM
9777.5
WeatherLock Metal
Weatherproofing Underlayment
—
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R11_II_OCR14002.8a 2017 FBC
Evaluation Re or
WeatherloCk_Non-HVHZ. dfdf
Approved for use outside HVHZ: Yes
Impact Resistant: NIA
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 1111 AE OCR14002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVH7.pdd
Created by Independent Third Party: Yes
9777.6
WeatherLock Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL9777_R11 IT QCR14QO2.8b 2017 FBC
Evaluats n_Report
Weatherlock HVHZ.pdf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R11_LL_OCR14Q02.8b 7017 FBC
valuation Repo
Weathe,rl0ck HVHZ.p.df
Created by Independent Third Party: Yes
9777.7 WeatherLock Specialty Tile & Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R11_ _QCR14 L4 8a 2Q-L7 FBC
Evaluation_ itep�r
Weatherlock Nc)n-HVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: +0/-142.5
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777_R11 AE_OCR14002.8a 2017 FBC Evaluatign_Re or
Weatherlock NQn-Independent T
Created by Independent Third Party: Yes
-�
Sack Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32329 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statemen
Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850,487,1395. '"Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the puhhc. To determine if you are a licensee under Chapter
455, F.S., please click here .
Produot Approval Accepts:
Credit Card
Safe
https://www.floridabuilding.org/pr/pr-app_dtl.aspx?pararn=wGEVXQwtDgtgkcMGblcW71%2fZr7gdugvKElMFg53ndV601883S636Kw%3d%3d Page 3 of 3
CREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE, 6T" EDITION (2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC
1 Owens Corning Parkway
Toledo, OH 43657
(800) 438--7465
www.owenscorning.com
Manufacturing Location: Brentwood, NH
Houston, TX
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1504.3.1, 1507.1.1
Properties:
Physical properties
REFERENCES
Entity
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
Report No.
NEI-039-02-01
NEI-042-02-01 REV2
NEI-045-02-01
NFI-045-02-01
NEI-053-02-01
NEI-053-02-01
NEI-093-02-02
OCF-213-02-01
OCF-237-02-01
OCF-252-02-01
OCF-252-02-01
OCF-253-02-02
OCF-272-02-01
OCF-296-02-02
PRI Construction
Materials
Technologies (TST5878)
OCF-297-02-01.1
PRI Construction
Materials
Technologies (TST5878)
OCF-318-02-01
PRI Construction
Materials
Technologies (TST5878)
OCF-320-02-01
PRI Construction
Materials
Technologies (TST5878)
OCF-320-02-01
PRI Construction
Materia#s
Technologies (TST5878)
OCF-321-02-01
PRI Construction
Materials
Technologies (TST5878)
OCF-322-02-01
PRI Construction
Materials
Technologies (TST5878)
OCF-355-02-01
'Determined to be equivalent to ASTM D 226-09, Type I
and II
OCR14002,8a
FL9777-R11
Issued October 11. 2017
Standard
ASTM D 1970
ASTM D 1970
TAS 103
ASTM G 155
TAS 103
ASTM G 155
ASTM D 1970
ASTM D 1623
UL 1897
ASTM D 4798
ASTM D 1970
ASTM D 1970
TAS 103
ICC-ES AC 188'
IGC-ES AG 48
ASTM D 1970
ASTM D 1970
TAS 103
ASTM G 155
ASTM D 1623
UL 1897
UL 1897
Year
2015
2015
1995
2005a
1995
2005a
2015
2009
2012
2001
2015
2015
1995
2012
2012
2015
2015
1995
2005a
2009
2D12
2012
1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
+r"J�
CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLockS Self -Sealing Ice & Water Barriers
WeatherLock® G
WeatherLockS G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
(Brentwood, NH)
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLockS G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock® Mat
WeatherLockS Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH or
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, T))
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLockS Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock® Metal
WeatherLock® Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft,
WeatherLock® Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock®
WeatherLock® Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, TX)
WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLockS Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BOND Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock® G (High
WeatherLockS G (High Tear) is a self -adhered, underlayment used as an alternative to
Tear)
ASTM D 226, Type I or Type I I roofing felt and ASTM D 1970 self -adhering polymer
(Houston, TX)
modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 654
WeatherLockS G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
OCR14002.8a FL9777-RI I Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERvicES, LLC
PRODUCT APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLockO Self -Sealing Ice & Water Barriers
Min, Roof Slope: 2:12 in accordance with the FBC
Application: All underlayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to undedayment
application. Prior to beginning installation, the underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3" side
laps and minimum 6" end laps staggered min. 6-ft.from preceding course. Additionally, if
applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap.
It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
VIAND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9
Underlavment Svstem No.1 — WeatherLock Soecialty Tile & Metal Only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCRt4002.8a FL9777-Rl t Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock@ Self -Sealing Ice & Water Barriers
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the fleck,
7) The underiayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 6'h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
2017.10.
No 74021
_ * * _ t 09:06:29
-04'00'
��• STATE OF • tU+`
:0,n•.•.c Zachary R. Priest, P.E.
��� �` '• O [� 1 ��� Florida Registration No. 74021
Organization No. ANE9641
SSiOlV
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
OCR14002.8a
ENO OF REPORT
FL9777-R11
Paae 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.